• Title/Summary/Keyword: wrist pulse

Search Result 65, Processing Time 0.017 seconds

A Review on Tibetan Traditional Medicine (티벳 전통의학(傳統醫學)에 관(關)한 고찰(考察))

  • Lee, Bong-Hyo;Park, Ji-Ha;Lee, Sang-Nam;Han, Chang-Hyun
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.14 no.3
    • /
    • pp.77-92
    • /
    • 2010
  • Objectives : There has been little known about the Tibetan medicine in the society for Korean medicine. The aim of this study is to review the system of Tibetan medicine and compare with Korean medicine. Methods : The authors investigated several literatures that mentioned Tibetan medicine and organized in physiology, pathology, diagnostics, and treatment. And then, we interpreted the characteristics of Tibetan medicine as well as compared Tibetan medicine with Korean medicine. After that, we analyzed the commons and the differences, and also found out the meaning of Tibetan medicine. Results : The theory of Tibetan medicine is basically constituted of three elements of Lung, Tripa, and Peken in every parts of physiology, pathology, diagnostics, and treatment. Many organs of human body are compared to the fabrications of building. There is a detail explanation about the process of the development of fetus in Tibetan medicine. Tibetan medicine uses taking pulse in wrist, analysis of urine, watching of tongue, sperm, and menstruation, and etc. for diagnosis. In Tibetan medicine, regimen is prior to other treatments such as surgical treatment and medications. Conclusions : There is the oriental thought of '3' in Tibetan medicine, and esoteric buddhism is solved in Tibetan medicine. The anatomy and the diagnostics using urine, sperm, and menstruation have especially been developed in Tibetan medicine. Tibetan medicine emphasizes the feature of preventive medicine.

Reliable Measurement and Analysis System for Ubiquitous Healthcare (고신뢰 유비쿼터스 헬스케어 데이터 측정 및 분석 시스템)

  • Jung, Sang-Joong;Seo, Yong-Su;Kim, Jong-Jin;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.293-297
    • /
    • 2009
  • This paper describes a real-time reliable measurement and analysis system for ubiquitous healthcare based on IEEE802.15.4 standard. In order to obtain and monitor physiological body signals continuously, wearable pulse oximeter is designed in wrist that could used to measure oxygen saturation of a patient unobtrusively. The measured data was transferred to a central PC or server by using wireless sensor nodes via a wireless sensor network for storage and analysis purposes. LabVIEW server program was designed to monitor and process the measured photoplethysmogram(PPG) to accelerated plethysmogram(APG) by appling second order derivatives in server PC. These experimental results demonstrate that APG can precisely describe the features of an individual's PPG and be used as estimation of vascular elasticity for blood circulation.

  • PDF

Development of Birdcage Resonator for Various Absorption Regions at 3T (3T MRI에서 흡수영역의 변화에 따른 Birdcage Resonator의 개발)

  • 이정우;최보영;윤성익;이형구;서태석;허순녕
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.54-58
    • /
    • 2004
  • The aim of this study was to develop special birdcage resonators for small objects including the human wrist, hand and small animals, using 3T MRI/MRS. Before substantial development, different types of parameters were arranged, based on theoretical analysis, through lumped element transmission line theory. The primary analysis was peformed with a network analyzer (HP 4195A) and the final experimental analysis was carried out with 3T MRI (Medinus, Korea). The manufactured birdcage resonator is typically composed of 12-element structures to which a low-pass filter is fundamentally applied. The diameter and length of each element of the birdcage resonator were as follows: (1) diameter 12 cm, length of element 22 cm, (2) diameter 15 cm, length of element 22 cm, and (2) diameter 17 cm, length of element 25 cm. Copper tape with a width of 1 cm was used for the coils. MRI acquisition parameters were TR=500 ms, TE=17 ms, and Ave=2 for T1-WT images, and TR=4,000 ms, TE=96 ms, and Ave=2 for T2-WT images. The ratio of the samples diameter to the birdcage resonators diameter was approximately 55%, 63% and 70%, respectively, for the three elements. This study determined that the best image quality and S/N ratio were obtained when the ratio of the object's diameter was approximately 50∼80%. A general theoretical analysis of the birdcage coil differs in many respects from the experimental results which were influenced by many factors that were not considering when the general theoretical analysis of the birdcage coil was peformed. The induced resistance may be considered as part of the resistive loss if the quantitative value can be determined using a radiation resistance approach.

  • PDF

Low Cost and High Sensitivity Flexible Pressure Sensor Based on Graphite Paste through Lamination after O2 Plasma Surface Treatment Process (O2 플라즈마 표면 처리 공정 후 라미네이션 공정으로 제작된 흑연 페이스트 기반의 저비용 및 고감도 유연 압력 센서)

  • Nam, Hyun Jin;Kang, Cheol;Lee, Seung-Woo;Kim, Sun Woo;Park, Se-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.4
    • /
    • pp.21-27
    • /
    • 2022
  • Flexible pressure sensor was developed using low-cost conductive graphite as printed electronics. Flexible pressure sensors are attracting attention as materials to be used in future industries such as medical, games, and AI. As a result of evaluating various electromechanical properties of the printed electrode for flexible pressure sensors, it showed a constant resistance change rate in a maximum tensile rate of 20%, 30° tension/bending, and a simple pulse test. A more appropriate matrix pattern was designed by simulating the electrodes for which this verification was completed. Utilizing the Serpentine pattern, we utilized a process that allows simultaneous fabrication and encapsulation of the matrix pattern. One side of the printed graphite electrode was O2 plasma surface treated to increase adhesive strength, rotated 90 times, and two electrodes were made into one through a lamination process. As a result of pasting the matrix pattern prepared in this way to the wrist pulse position of the human body and proceeding with the actual measurement, a constant rate of resistance change was shown regardless of gender.

Effects of Music on Dental Anxiety and Pain during Ultrasonic Teeth Scaling (치석제거술시 치통 및 불안에 대한 음악의 효과)

  • Kim, Hyo-Suk;Choi, Chung-Ho;Hwang, Kyu-Yoon;Lee, Sung-Soo
    • Journal of Korean society of Dental Hygiene
    • /
    • v.1 no.1
    • /
    • pp.63-76
    • /
    • 2001
  • This study was designed to evaluate the effects of music on dental pain and anxiety during ultrasonic scaling. One hundred and twenty five patients visited dental unit of Soonchunhyang University Chunan hospital for scaling were enrolled during August 1999 and February 2000. The patients were allocated randomly into two groups. music (n = 61) and control groups (n = 65). The music group patients listened to self-selected music using an earphone during scaling. Standardized questionnaire were used to assess the subjective denial pain and anxiety before and after scaling in both groups. In music group, more information on music effect was collected. To evaluate changes of physical signs by scaling, blood pressure and pulse were checked by a wrist check oscillometric. The results were as follows: 1. No significant difference in dental pain and anxiety between before and after scaling was observed in music group. However, the music group patients were satisfied with music because of reduction of pain(93.5%) and anxiety(93.4%), 96.7% of music subjects wanted to listen to music in next scaling. 2. While no significant difference in systolic blood pressure before scaling between music and control groups, systolic blood pressure of control group during scaling was significantly higher than that of music group(P<0.05). 3. In multiple logistic regression. the odds ratio(OR) of pain was decreased with age and female patients had higher OR (1.7, p>0.05). Patients with previous scaling experience complained of more dental pain during scaling than patients without experience. Music was not a significant predictor of denial pain during scaling, controlling for possible confounders. 4. While age. music. and scaling experience were not related to dental anxiety during scaling, sex and dental hygiene index were significant predictors of dental anxiety in multiple logistic regression. 5. Both during and after scaling. mean blood pressure of music patients were significantly lower than control patients after controlling for age, sex, and BMI. In conclusion, our data demonstrated that although listening to music did not disappear the dental pain and anxiety. but reduced the intensity of pain and anxiety during scaling. Furthermore, our data imply thai music has a effect of reduction of increasing blood pressure by scaling.

  • PDF