• Title/Summary/Keyword: wrap

Search Result 409, Processing Time 0.025 seconds

Current Status of Emitter Wrap-Through c-Si Solar Cell Development (에미터 랩쓰루 실리콘 태양전지 개발)

  • Cho, Jaeeock;Yang, Byungki;Lee, Honggu;Hyun, Deochwan;Jung, Woowon;Lee, Daejong;Hong, Keunkee;Lee, Seong-Eun;Hong, Jeongeui
    • Current Photovoltaic Research
    • /
    • v.1 no.1
    • /
    • pp.17-26
    • /
    • 2013
  • In contrast to conventional crystalline cells, back-contact solar cells feature high efficiencies, simpler module assembly, and better aesthetics. The highest commercialized cell and module efficiency was recorded by n-type back-contact solar cells. However, the mainstream PV industry uses a p-type substrate instead of n-type due to the high costs and complexity of the manufacturing processes in the case of the latter. P-type back-contact solar cells such as metal wrap-through and emitter wrap-through, which are inexpensive and compatible with the current PV industry, have consequently been developed. In this paper the characteristics of EWT (emitter wrap-through) solar cells and their status and prospects for development are discussed.

Comparison of the Effect of Applying Polyethylene Wrap and Aircap in Maintaining Body Temperature of Preterm Infants (폴리에틸렌 랩과 에어캡의 적용이 미숙아의 체온 유지에 미치는 효과)

  • Lee, Eun Sook;Lee, Han Na;Park, Ji Hyun
    • Journal of Korean Clinical Nursing Research
    • /
    • v.26 no.2
    • /
    • pp.232-239
    • /
    • 2020
  • Purpose: This study was an quasi-experimental study to compare the effect of applying polyethylene wrap and aircap in maintaining body temperature of preterm infants. Methods: The participants were 51 preterm infants. Aircap was applied to the experimental group (n=23) and polyethylene wrap was applied to the control group (n=28) when the preterm infants admitted to neonatal intensive care unit. The data was collected at W hospital in J-province from June 2016 to May 2017. A total of 9 body temperature measurements were taken at 3 hours interval from 5 min to 24 hours after admission. Repeated measure ANOVA, independent t-test and χ2 test were conducted used with SPSS/WIN 24.0 Results: There were no significant difference in the homogeneity tests for general characteristics and dependent variables prior to the experiments (t=0.57, p=.566). There was a significant difference on body temperature of preterm infants over time (F=3.24, p=.020). There was no significant difference on body temperature between polyethylene wrap and aircap application groups (F=1.29, p=.261). The interaction between the group and the time was insignificant (F=1.51, p=.214). Conclusion: The findings demonstrated that both methods of applying polyethylene wrap and aircap on the body in preterm infants had effect in maintaining body temperature.

Wrap-around Noise Removal by Seismic Wave Attenuation (Seismic Wave Attenuation에 의한 Wrap-around Noise의 제거)

  • 정성종
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.12 no.3
    • /
    • pp.285-291
    • /
    • 1987
  • Seismic waves are attenuated by losses of energy as they propagate through the earth. One way to model this numerically is to make the velocity a complex number, the real part giving the phase velocity and the imaginary part the attenuation. This models wave propagation in a medium for which the logarithmic decrement is independent of frequency(attenuation coefficient is proportional to frequncy). The aim is to modify forward and inverse numerical modeling so that attenuation can be specified as a function of position.

  • PDF

Wire-wrap Models for Subchannel Blockage Analysis

  • Ha K.S.;Jeong H.Y.;Chang W.P.;Kwon Y.M.;Lee Y.B.
    • Nuclear Engineering and Technology
    • /
    • v.36 no.2
    • /
    • pp.165-174
    • /
    • 2004
  • The distributed resistance model has been recently implemented into the MATRA-LMR code in order to improve its prediction capability over the wire-wrap model for a flow blockage analysis in the LMR. The code capability has been investigated using experimental data observed in the FFM (Fuel Failure Mock-up)-2A and 5B for two typical flow conditions in a blocked channel. The predicted results by the MATRA-LMR with a distributed resistance model agreed well with the experimental data for wire-wrapped subchannels. However, it is suggested that the parameter n in the distributed resistance model needs to be calibrated accurately for a reasonable prediction of the temperature field under a low flow condition. Finally, the analyses of a blockage for the assembly of the KALIMER design are performed. Satisfactory results by the MATRA-LMR code were obtained through and rerified a comparison with results of the SABRE code.

Feasibility study for wrap-buoy assisted wet-tow and stepwise installation of mono-bucket foundation for 15 MW offshore wind turbine

  • Ikjae, Lee;Moohyun, Kim
    • Ocean Systems Engineering
    • /
    • v.12 no.4
    • /
    • pp.413-437
    • /
    • 2022
  • An innovative concept for wet-transportation and stepwise installation of mono-bucket foundation for 15 MW offshore wind turbine is proposed. Case studies for two different mono-bucket and wrap-buoy dimensions are conducted and their hydrostatic and hydrodynamic performances are compared for both wet-towing and lowering operations. The intact stability and transient responses are analyzed in detail for various stages of lowering operation. Wave-induced motion statistics during wet tow in sea state 4 (highest operational window) are checked. The proposed concept is found to be feasible and can be an alternative cost-effective solution without using heavy-lift crane vessel in practice.

Thumb Reconstruction with a Free Neurovascular Wrap-Around Flap from the Big Toe (족무지 유리 피부편을 이용한 수무지 재건)

  • Lee, Kwang-Suk;Chae, In-Jung;Hahn, Seung-Beom
    • Archives of Reconstructive Microsurgery
    • /
    • v.3 no.1
    • /
    • pp.72-80
    • /
    • 1994
  • There are several methods to reconstruct an amputated or lost thumb such as toe to thumb transfer, pollicization and other variety of free flaps. In 1980, Morrison and O'Brien advocated reconstruction of the thumb with a free wrap-around flap from the big toe to recreate a stable, sensate and functional digit, including the nail. From March, 1982 to December, 1992, thirty cases of thumb reconstructions were performed using the wrap-around procedure at Korea University Hospital. 1. 29 cases of total 30 cases were successful and can be obtained the excellent results in functional and cosmetic aspect. 2. In postoperative complications, one case is graft failure, six cases in partial skin necrosis, one case in malunion, 15 cases in resorption of grafted bone piece were come out. 3. Even if the 1st metacarpal neck amputation is occurred, thumb reconstruction with a free neurovascular wrap-around flap was also possible, however, the limitation of the mobility of the reconstructed thumb and resorption of grafted bone piece were come out. We concluded that cosmesis and fuctional results were quite satisfactory despite of some complications. The thumb reconstruction with a wrap around free flap from the big toe in thumb amputated patients is the excellent method in the cosmetic and functional aspect and can be considered as the most useful method because of less morbidity to the donor site and the operator should be trained to get the meticulous microsurgical technique and to detect the complications.

  • PDF

Staged Reconstruction of the Mangled Hand with the Combined Use of Pedicled Groin Flap and Free Wrap Around Flap (광범위 수부 손상에서 서혜부 유경피판과 유리 포장주위피판을 이용한 단계적 무지 재건술)

  • Roh, Young-Hak;Chung, Moon-Sang;Baek, Goo-Hyun;Lee, Young-Ho;Gong, Hyun-Sik;Rhee, Seung-Hwan;Lee, Ye-Hyun
    • Archives of Reconstructive Microsurgery
    • /
    • v.18 no.2
    • /
    • pp.62-66
    • /
    • 2009
  • Purpose: Despite the free tissue transfer using microsurgical technique being the current trend of soft tissue reconstruction of the hand, the pedicled groin flap has the advantage to provide coverage for the mangled hand without necessitating the use of a damaged arterial system and also providing the benefit of saving the arterial system for later free tissue transfer. This report presents the author's experience using pedicled groin flap in four cases of mangled hands with massive bone and soft tissue defects requiring later thumb reconstruction with the free wrap around flap. Materials and methods: The patients' age ranged from 30 to 51 years; three patients were male and one was female. The causes of mangled hand included two machinery crush injuries, one laboratory explosion and one motor vehicle accident. While evaluating the post-operative results, factors like flap survival, complications, stability in opposition, pinch power and 2 point discrimination were taken into account. Results: All massive soft tissue defects of the hands were completely covered with pedicled groin flap successfully. The reconstructed thumb using free wrap around flap did not have any limitation in opposition. There was no occurrence of post-operative infection and all the flaps survived completely. The average pinch power was 70% of the contralateral intact thumb and average 2 point discrimination was 10 mm. Conclusion: The pedicled groin flap for the reconstruction of the massive soft tissue defects of the hand with subsequent reconstruction of the thumb with a wrap around flap is a very useful procedure. The combined use of pedicled groin flap and wrap around flap allows adequate coverage of sizable soft tissue defects and functional thumb opposition in cases of reconstruction of the mangled hands.

  • PDF

A Study on Development of Eco-friendly Wrap using Biodegradable Resin (생분해성 수지를 이용한 환경친화성 랩 개발에 관한 연구)

  • Lim, Mi-Jin;Sim, Jae-Ho;Choi, Jong-Moon;Kim, Young-Sik
    • Applied Chemistry for Engineering
    • /
    • v.16 no.6
    • /
    • pp.800-808
    • /
    • 2005
  • The compounding resin for biodegradable wrap was developed, and its manufacturing process and physical properties were studied. For these purposes, following factors were optimized: the types and amounts of raw resin material, anti-oxidants, and lubricants used. In this work, the stable compounding resin used to make biodegradable wrap was based on poly(butylene adipate-co-butylenesuccinate) (PBAS) and poly(butyleneadipate-co-butylene succinate-co-butyleneterephthalate) (PBAST). The improved properties of resin with an additive were investigated by melting flow index (MFI). From these results, the physical properties of compounding resin, based on PBAST, were more than those of PBAS. For PBAS, the Irganox 1010, 1076 and Irgafos TNPP as the first and second anti-oxidants, respectively, were good. For PBAST, the good first and second anti-oxidants, respectively, were Irganox 1076 and Mark PEP 36. The good lubricants for feeding PBAS and PBAST were glycerol monostearate and palmityl alcohol, respectively. The stability and tensile strength experiment of wrap were also investigated by the elution of heavy metals and universal testing machine (UTM), respectively. The decomposition ratio of developed wrap was increased proportional to the reclaiming time. The degradation ratio of compounding resin sample was about 60% after 40 days.