• Title/Summary/Keyword: worst case analysis

Search Result 294, Processing Time 0.023 seconds

Human Engineering Approach to the Standardization of Shelving, Chairs, Tables and Card Cabinets for College and University Libraries In Korea (한국 대학도서관 가구의 표준화에 관한 인간공학적 연구 -서가${\cdot}$의자${\cdot}$책상${\cdot}$ 목록함을 중심으로-)

  • Sohn Jung Pyo
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.11
    • /
    • pp.3-42
    • /
    • 1984
  • This is to establish a model of the standardization of shelving, chairs, tables and card cabinets for college and university libraries in Korea. The size of furniture was measured on the base of the analysis of the human factors, such as the standard size of human bodies of the college students in Korea, the scope of work area, the moving degree of muscles, the limit of the visual field, etc. The results of this study are as follows: 1. It is desirable that the standard shelf length should be 800mm. and the maximum . shelving height should not exceed 1,803mm. And it is desirable that the bottom shelf has a ground clearance of about $210\~390mm$. 2. It is advisable that the sloped shelving has the slope from about 1,000mm, or 930mm, and the gradient should be $19^{\circ}$ from the above mentioned sloping position and the bottom of each shelf. And it is desirable that the slope height of each shelf should be 77mm. 3. It is advisable that the seat area for users should be $410\~420\times420mm$, and the seat height should be $390\~0400mm$. 4. It is desirable that the table size per user should exceed $490\times880\~890mm$, and the table height should be $680\~690mm$. 5. It is advisable that each tray of the card cabinet should hold about 740 cards, and the depth should exceed 430mm. And it is desirable that the maximum height of card cabinets should be as follows: 60du(drawer units)-$1,400\~1,460mm$, 30du-1, 300mm, 15du-1,100mm. In addition, it is advisable that the 30du cabinet should accomodate 5 trays vertically and 6 trays horizontally for avoiding the worst working position rather than 6 trays vertically and 5 trays horizontally. 6. It is desirable that the height of sliding reference shelves in card cabinets, or consultation tables should be 900mm. But in the case of the sliding shelves, it is desirable to be as follows: 15du-900mm when the card cabinet height is more than 1,100, mm, but unnecessary when less than 1,100mm high, 30du-1,000mm, or 1,100mm in the case of $5\times6du$, but 900mm in the case of $6\times5du$, $60du-900\~950mm$ when the card cabinet height is $1,400\~1,460mm$.

  • PDF

Risk based policy at big data era: Case study of privacy invasion (빅 데이터 시대 위험기반의 정책 - 개인정보침해 사례를 중심으로 -)

  • Moon, Hyejung;Cho, Hyun Suk
    • Informatization Policy
    • /
    • v.19 no.4
    • /
    • pp.63-82
    • /
    • 2012
  • The world's best level of ICT(Information, Communication and Technology) infrastructure has experienced the world's worst level of ICT accident in Korea. The number of major accidents of privacy invasion has been three times larger than the total number of Internet user of Korea. The cause of the severe accident was due to big data environment. As a result, big data environment has become an important policy agenda. This paper has conducted analyzing the accident case of data spill to study policy issues for ICT security from a social science perspective focusing on risk. The results from case analysis are as follows. First, ICT risk can be categorized 'severe, strong, intensive and individual'from the level of both probability and impact. Second, strategy of risk management can be designated 'avoid, transfer, mitigate, accept' by understanding their own culture type of relative group such as 'hierarchy, egalitarianism, fatalism and individualism'. Third, personal data has contained characteristics of big data such like 'volume, velocity, variety' for each risk situation. Therefore, government needs to establish a standing organization responsible for ICT risk policy and management in a new big data era. And the policy for ICT risk management needs to balance in considering 'technology, norms, laws, and market'in big data era.

  • PDF

Evaluation of Damage Range Variation Based on Operation System of Chlorine Facility in Water Purification Plant using KORA (KORA를 활용한 정수장 염소 취급시설의 운영조건에 따른 피해범위 변화 평가)

  • Kwak, Sollim;Lim, Hyeongjun;Ryu, Taekwon;Choi, Woosoo;Jung, Jinhee;Lee, Jieun;Kim, Jungkon;Lee, Yeonhee;Ryu, Jisung;Yoon, Junheon;Yoon, Yi;Lee, Jinseon
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.84-90
    • /
    • 2018
  • We researched the way to minimize the damage when the chlorine-leak accident take place in a purification plant. Since the level of risk based on the Off-site Risk Assessment(ORA) is a combination of proportional to the number of residents in the damaged area and frequency of accidents, we suggested the adequate conditions to reduce the number of residents in the damaged area by means of the operating temperature of a handling facility, installation of a emergency shut-off valve, and the analysis of the variation of the damaging range in accordance with the type of enclosure. The coverage of damage was calculated by the 'KORA(Korea Off-site Risk Assessment Supporting Tool) program. The research shows that the lower operating temperature gets, the more emergency shut-off valve being installed and the higher enclosure level of facility becomes, the extent of damage gets decreased. The decreasing rate of worst case was 17.6%, 71%, 34.5% respectively, the decreasing rate of alternative case was 31.6%, 69.0%, 34.8% respectively.

Consequence Analysis of Hydrogen Filling Stations based on Cascade Compressing Systems (케스케이드 방식 압축시스템 기반의 수소충전소에 대한 정성적 위험성평가)

  • Ahn, Byeong-Jun;Rhim, Jong-Kuk
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.2
    • /
    • pp.13-21
    • /
    • 2021
  • Because of the recent expansion of hydrogen vehicle supply, the installation of hydrogen filling station is expected to gradually expand. This study attempts to predict the damage scale and propose a safer design form based on the scenario that assumes the worst case of a hydrogen station. A Flacs solver using computational fluid dynamics (CFD) was used to predict the damage scale, and the accuracy was verified by comparing it with the experimental results of previous researchers. The damage scale prediction was conducted for hydrogen leakage and explosion, and the prediction target was the KR model based on the measured values. And as a comparative review model, a roofless model was selected without a ceiling. As a result of analyzing the two models, it was possible to confirm the accumulation and retention of hydrogen gas up to 60 vol% or more in the KR model, whereas in the case of the Roofless model, the phenomenon of discharge and diffusion to the outside of the charging station by riding the wall after leakage. I was able to check. In conclusion, it was reviewed that the type of hydrogen charging station without ceiling is more advantageous for safety than the hydrogen filling station model.

An Analysis of the Composite Discharge Capacity Effect with GCP Method (GCP공법의 복합통수능 효과 분석)

  • Park, Minchul;Kwon, Hyukchan;Shin, Hyohee;Jang, Gisoo;Lee, Song
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.12
    • /
    • pp.37-46
    • /
    • 2011
  • An application frequency of vertical drainage method is increasing as an effective consolidation acceleration method. PBD method is most frequently used as a consolidation acceleration method in vertical drainage methods. PBD is economical and easy to operate but has some problems those are an environmental pollution and a decrease of a discharge capacity caused by bending of drainage materials when it is used in great depth. SCP method was frequently used because it's discharge capacity was good but now it is rarely used because of an increase of the material price because of an order imbalance. As the way to solve these problems, GCP method has been to the fore. For analyzing the effect of GCP method on the discharge capacity, three types of composite discharge capacity tests are done by using GCP, SCP and PBD respectively with the circle case, ${\phi}38{\times}h70cm$. On the contrary to this, GCP shows the worst discharge capacity for a decrease of the void ratio and the clogging phenomenon caused by increasing load. Also to figure out the clogging range of GCP, the clogging of GCP is checked in each load stage with a large case($1.0m{\times}0.5m{\times}1.1m$) which has clear acrylic front face. The diameter of GCP was 35cm and a clogging phenomenon occurred in 10% approximately. The result shows that the discharge capacity of GCP was given the lowest value for a decrease of the void ratio and the clogging phenomenon causing by increasing load. And the clogging phenomenon mostly occurred within 10% of GCP's diameter range.

A Study on Systematic Risk Assessment Method for LNG Storage Facilities (LNG 저장설비에 대한 체계적인 위험성평가 방법에 관한 연구)

  • Kang, Mee-Jin;Lee, Young-Soon;Lee, Seung-Rim
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.1
    • /
    • pp.14-20
    • /
    • 2009
  • As the consumption of LNG has increased, the capacity and number of LNG facilities are getting bigger and bigger. Such circumstances supports the need for a dedicated risk analysis model to help review and check major issues of the safer construction and operation of LNG storage facilities systematically. Therefore this study suggests an appropriate risk analysis model that enables us to evaluate hazards of LNG storage facilities more easily and systematically, and then to use its result in siting, design and construction stages of the facilities. ill order to develop the model, lots of existing studies and domestic and foreign codes and standards were fully reviewed and a series of case studies also were carried out. The suggested model consists of 4-stage evaluations: in selecting a site, in determining a layout, in designing and constructing the facilities, and in operating them. This model also suggests the weather condition necessary for estimating the consequence of accident-scenarios, and the easy, systematic approach to the analysis of their probability. We expect that the model may help secure LNG storage facilities' inherent safety in determining their site and layout.

  • PDF

A Game Theoretic Analysis of Social Commerce Ecosystem at the Crossroads (소셜커머스 생태계의 게임 분석)

  • Kim, Dohoon
    • Asia pacific journal of information systems
    • /
    • v.23 no.2
    • /
    • pp.67-86
    • /
    • 2013
  • This study first provides a stylized model that captures the essential features of the SC (Social Commerce) business and the competition process. The model focuses on the relationship between key decision issues such as marketing inputs and market value. As more SCs join the industry, they are inevitably faced with fierce competition, which may lead to sharp increase in the total marketing and advertising expenditure. This type of competition may lead the industry away from its optimal development path, and at worst, toward a disruption of the entire industry ecosystem. Such being the case, another goal of this study is to examine the possibility that the ToC (Tragedy of the Commons) may occur in the SC industry. We build game models, each of which assumes homogeneity and heterogeneity of SC providers, respectively, and derive explicit equilibrium solutions from both models. Our basic analysis presents Nash equilibria in both models and shows that SC providers are inevitably faced with fierce competition, which may lead to sharp increase in the total marketing expenses. We also compare the game outcomes with one with a hypothetical social planner who determines the total marketing level that optimizes the entire market value. Then, ToC can be defined to describe the situation where the total marketing efforts exceed the socially optimal level of marketing efforts. In both models, we examine the possibility of the ecosystem disruption and specify the conditions under which ToC may occur. However, the chance of avoiding ToC is higher with heterogeneous players than with homogeneous players. To supplement our analytical results, we develop a simulation model which incorporates a market dynamics based on the gap between actual marketing efforts and socially optimal marketing level. Simulation experiments present some lessons and insights which also confirm out findings from equilibrium analysis. For example, heterogeneity in SC providers alleviates the severity of ToC and makes it faster for survivors to escape from the ToC trap. As a result, the degree of industrial concentration tends to increase, which also explains the 'rich-get-richer' phenomenon observed in some empirical studies on the SC industry. Lastly, based on our analytical and experimental results, we come up with some measures to avoid ToC and overcome the shortcomings intrinsic to the current business model. And further discussions provide strategic implications and policy directions to overcome the possible trap of ToC in this ecosystem, and eventually help the industry to sustainably develop itself toward the next level. To name a few examples of policy measures, regulations on the marketing activities so that the overall marketing expenses cannot go beyond the socially optimal level; institutional guidelines and rules to straightening up the distortions in the way that SC providers view the marketing costs (the current marketing costs are underestimated, thereby encouraging SC providers to increase marketing expenditure); and so on.

  • PDF

A study on damage prediction analysis for styrene monomer fire explosion accidents (스티렌 모노머 화재폭발사고 피해예측 분석에 관한 연구)

  • Hyung-Su Choi;Min-Je Choi;Guy-Sun Cho
    • Industry Promotion Research
    • /
    • v.9 no.2
    • /
    • pp.37-44
    • /
    • 2024
  • This study selected the worst-case scenario for fireball and vapor cloud explosion (VCE) of a styrene monomer storage tank installed in a petrochemical production plant and performed damage prediction and accident impact analysis. The range of influence of radiant heat and overpressure due to fireball and vapor VCE during the abnormal polymerization reaction of styrene monomer, the main component of the mixed residue oil storage tank, was quantitatively analyzed by applying the e-CA accident damage prediction program. The damage impact areas of radiant heat and explosion overpressure are analyzed to have a maximum radius of 1,150m and 626m, respectively. People within 1,150m of radiant heat of 4kW/m2 may have their skin swell when exposed to it for 20 seconds. In buildings within 626m, where an explosion overpressure of 21kPa is applied, steel structures may be damaged and separated from the foundation, and people may suffer physical injuries. In the event of a fire, explosion or leak, determine the risk standards such as the degree of risk and acceptability to workers in the work place, nearby residents, or surrounding facilities due to radiant heat or overpressure, identify the hazards and risks of the materials handled, and establish an emergency response system. It is expected that it will be helpful in establishing measures to minimize damage to workplaces through improvement and investment activities.

Analysis on Suitability Light Intensity and Introduction Plan under the Indoor Lighting for the Native Evergreen Daphniphyllum macropodum (자생 상록 굴거리나무의 실내조명 하에서 적정광도 분석 및 도입방안)

  • Shin, Hyeon-Cheol;Yun, Jae-Gill;Choi, Kyoung-Ok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.1
    • /
    • pp.110-117
    • /
    • 2012
  • This study was performed to determine light-adaptability under indoor lighting for Korean wild Daphniphyllum macropodum, and to provide an introduction plan for indoor spaces of landscape architecture. The experimental plants, Daphniphyllum macropodum were purchased from a farmhouse in Jejudo as anannualplant, and it was acclimatized in the glass-green house of the general farm of Gyeongnam National University of Science and Technology for40 days. The experiment was performed from February 15, 2010 to November 15, 2010. First, in the case of the fluorescent lamp, the growth and development condition was poor because the plants withered, or the leaves fell off under the 100lux to 500lux, but the condition under 1,000lux was good In the aspects of the number of leaves, form of the tree, photosynthesis rate in its body, and the value of sight, the best light intensity for the growth condition was under the 1,000lux. Second, in the case of the LED light, the growth and development condition was poor because the plants withered, or the leaves fell off under 100lux to 1,000lux, but the smooth growth and development was done under a more light intensity. The best intensity for the growth condition was under 2,000lux. Third, in the case of the three-wave light, the withering was serious by 1,000lux, and the growth and development was the worst amongst the four introduced lighting systems, therefore, growth under the three-wave light was incongruous. The best intensity for the growth condition was under 2,000lux. Fourth, in the case of the optical fiver, the withering did not existed under 100lux and growth was possible. The growth and development was the amongst in the four introduced lighting systems. Generally, in the more light intensity, more growth was observed, but the value of sight was higher under 1,000lux than under 2,000lux because the falling rate of leaves and the form of the tree was stable. The most effective light was under 1,000lux due to the high photosynthesis in its body. When Daphniphyllum macropodum is introduced into the indoor landscaping space considering the light, the optical fiber, fluorescent lamp, and LED light are suitable to introduce. The three-wave light is unfit. The most proper light intensity by the light source, in the case of the optical fiber, and fluorescent lamp, is 1,000lux, and, in the case of LED light, is 2,000lux. The wild Daphniphyllum macropodum is the species of tree to substitute the Schefflera actinophylla which is the introduced species, and it is expected to be use as the central tree in indoor spaces.

Rock Slope Stability Investigations Conducted on the Road Cut in Samrangjin-Miryang Area (삼량진-밀양 지역에 위치한 도로 절취사면에 대한 사면안정 연구)

  • Um Jeong-Gi;Kang Taeseung;Hwang Jin Yeon
    • Economic and Environmental Geology
    • /
    • v.38 no.3 s.172
    • /
    • pp.305-317
    • /
    • 2005
  • This study addresses the preliminary results of rock slope stability analyses including hazard assessments for slope failure conducted on the selected sections of rural road cut slope which are about 4 km long. The study area is located in the Mt. Chuntae northeast of Busan and mainly composed of Cretaceous rhyolitic ash-flow tuff', fallout tuff, rhyolitc and andesite. The volcanic rock mass in the area has a number of discontinuities that produce a potentially unstable slope, as the present cut slope is more than 70 degrees in most of the slope sections. Discontinuity geometry data were collected at selected 8 scanline sections and analyzed to estimate important discontinuity geometry parameters to perform rock slope kinematic and block theory analyses. Kinematic analysis for plane sliding has resulted in maximum safe slope angles greater than $65^{\circ}$ for most of the discontinuities. For most of the wedges, maximum safe cut slope angles greater than $45^{\circ}$ were obtained. Maximum safe slope angles greater than 80" were obtained fur most of the discontinuities in the toppling case. The block theory analysis resulted in the identification of potential key blocks (type II) in the SL4, SL5, SL6 and SL8 sections. The chance of sliding taking place through a type ll block under a combined gravitational and external loading is quite high in the investigated area. The results support in-field observations of a potentially unstable slope that could become hazardous under external forces. The results obtained through limit equilibrium slope stability analyses show how a stable slope can become an unstable slope as the water pressure acting on joints increases and how a stable slope under Barton's shear strength criterion can fail as the worst case scenario of using Mohr-Coulomb criterion.