• Title/Summary/Keyword: workload measurement

Search Result 76, Processing Time 0.03 seconds

Performance simulation of an electric multi-purpose cultivator according to rotary tillage

  • Seung-Yun, Baek;Wan-Soo, Kim;Seung-Min, Baek;Hyeon-Ho, Jeon;Jun-Ho, Lee;Dae-Hyun, Lee;Kyu-Hong, Choi;Yong-Joo, Kim;Seung-Muk, Choi
    • Korean Journal of Agricultural Science
    • /
    • v.48 no.4
    • /
    • pp.1027-1037
    • /
    • 2021
  • This study aims to evaluate the performance of an electric multi-purpose cultivator through a simulation analysis. The simulation model was developed using commercial software, Simulation X, by applying the specifications of certain parts, such as an electric motor, a battery, and so on. The input parameter of the simulation was the engine load data according to the rotary tillage level using a conventional multi-purpose cultivator. The data were collected by configuring a load measurement system, and the load cycle was developed by repeating the data collection process under the most severe conditions. The average output engine torque values of conventional multi-purpose cultivator were 10.7, 13.0, 9.4, and 11.2 Nm in the D1P1, D1P2, D2P1, and D2P2 conditions, respectively. As a result of the simulation, the maximum values of the motor torque, rotational speed, and power of the electric multi-purpose cultivator were 16.8 Nm, 2,033.3 rpm, and 3.3 kW, respectively, and the motor was driven in sections within 70, 68, and 45% of the maximum output range. The rate of decrease of the battery state of charge (SOC) level per minute was approximately 0.6%, and it was possible to supply electric power to the motor for 9,550 sec. In the future study, research to verify and improve simulation models of electric multi-purpose cultivators should be conducted.

Experimental Research for CO2 Emission Estimation of Medium-Scale Excavator Reflecting Work Characteristics (작업 특성을 반영한 중규모 굴삭기의 CO2 배출량산정을 위한 실험적 연구)

  • Kim, Seung Hyun;Lee, Dong Wook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.4
    • /
    • pp.717-727
    • /
    • 2017
  • Researches on the emissions of greenhouse gases in the construction industry, which accounts for 40% of raw materials, 30% of energy consumption, and 30% of $CO_2$ emissions in the entire industry, are mainly focused on studies of LCA. However, it is assessed that $CO_2$ emissions are higher in construction sequence than in operation sequence. Also, it is considered that construction machinery using fossil fuel is a main factor causing environmental load in construction sequence. Therefore, this study analyzes the workload and engine RPM characteristics of the excavator which is the second largest number of registered construction machinery in Korea and the highest utilization rate in actual construction site. The excavator is divided into non-load states and load states where power is transmitted to the excavator. The exhaust gas is analyzed by a direct measurement method using PEMS equipment. $CO_2$ emissions are estimated by analyzing the relationship between RPM and exhaust emission characteristics according to the actual driving conditions. Additionally, we analyze the difference between $CO_2$ emissions of construction machine calculated by this study and $CO_2$ emissions calculated by using carbon emission coefficient.

An Analysis of Work Stress of Physical Therapist and Reaction (물리치료사의 업무 스트레스 현황과 대응수준 -부산지역을 중심으로-)

  • Dong, Jong Ick;Ryu, Hwang Gun;Bae, Sung-Kwon
    • The Korean Journal of Health Service Management
    • /
    • v.2 no.1
    • /
    • pp.37-55
    • /
    • 2008
  • This study aims to enhance work efficiency and satisfaction by offering data that make a physical therapist cope with stress coming from the job efficiently by identifying and analyzing the job satisfaction and work stress perceived by a physical therapist, and the level of reaction of a physical therapist. The study distributed survey questionnaires to 300 physical therapists working in medical institutions in Busan via mail and by visit from March 3, 2007 by selecting them simply and randomly from the physical therapist list, and collected the questionnaires by March 20, 2007, 103 respondents were working at 17 general hospitals including a university hospital, 65 respondents at 12 medical centers, and 79 respondents at 39 doctor's offices. The study collected 251 copies, which showed the collection rate of 83.7%, and analyzed 247 copies (82.3%) excluding 4 copies of insincere answers. As a research tool for measuring job satisfaction the study used a tool employed for research into the job satisfaction of physical therapists who work at medical institutions in Gwangju, Jeonnam, and Jeonbuk by Kim Hee-Gwon(1992) and research regarding job satisfaction by Jeong Jeong-Hee(2004) as well as research regarding the factors of job satisfaction by Flippo(1980) & Seberhagen(1970) after adjusting the research tools to the purpose of the study. Also for questions about work stress, the study employed nurses' job stress measurement tool developed by Kim Mae-Ja and em Mi-Ok(1984) by modifying the tool to the purpose of the study, and for a measurement tool for reaction to stress, the study used a tool employed for research into reaction to stress of nurses at general hospitals by Choi Eun-Deok(2005) without modification. For data analysis, the study used the SPSS12.0 as a statistical method, and then used t-test or ANOVA for verifying actual numbers, percentile, average :score, standard deviation, rank, and difference. Also, the study conducted which is a post-test method for variables that show a significant difference at the level of p<.05 level after the analysis. The findings include the following. 1) The respondents' job satisfaction score was 3.21 points on the average (out of 5 full points). The peer relationship ranked the highest, posting 4.02 points on the average, and the job satisfaction with rewards was proven the lowest, posting 2.51 points. For the job satisfaction level by characteristics, there were significant differences (p<.05) in gender, hospital type, weekly working hours, monthly working days, number of patients per day, department in charge of therapy, and number of peers, and there was no significant difference in characteristics other than that. 2) The respondents' work stress score was 2.72 points (out of 5 full points) on the average. The respondents were shown to be under the highest stress when they suffered from excessive workload, posting 3.49 points on the average, and they were shown to be under the least stress when they had a conflict with peers at another department, recording 1.90 points on the average. for the job stress level by the characteristics of job, there was a significant difference in the reflection of job assessment(p<.05). 3) 1n respondents' reaction to stress, most of them were shown to make efforts in coping with stress, posting 2.80 points (out of 5 full points). For their experience of being wider stress, they answered that 'they felt depressed (2.85 points)" for their experience of coping with stress, they answered that 'they were indifferent to it or thought about something else' (2.62 points). Also, for their efforts in coping with stress, they answered that 'they were motivated to remove their strain by taking leave, playing, or using their preferences' (3.52 points), which ranked higher. For the level of reaction to stress by characteristics, there were significant differences by age, gender, marital status, total service years as a physical therapist, monthly working days, and department in charge of therapy(p<.05). It is necessary to offer correct information by conducting an in-depth analysis of the stressful situations of physical therapists who exert efforts in rehabilitating patients at hospitals by factor, and seeking management plans based on the research results. Also, it is necessary to develop a program for coping with stress efficiently for removing stress and to conduct research into the understanding and cooperation of administrators and persons in charge of physical therapists for reducing physical therapists' stress at hospitals.

  • PDF

Comparison of the Efficacy of 2D Dosimetry Systems in the Pre-treatment Verification of IMRT (세기조절방사선치료의 환자별 정도관리를 위한 2차원적 선량계의 유용성 평가)

  • Hong, Chae-Seon;Lim, Jong-Soo;Ju, Sang-Gyu;Shin, Eun-Hyuk;Han, Young-Yih;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.27 no.2
    • /
    • pp.91-102
    • /
    • 2009
  • Purpose: To compare the accuracy and efficacy of EDR2 film, a 2D ionization chamber array (MatriXX) and an amorphous silicon electronic portal imaging device (EPID) in the pre-treatment QA of IMRT. Materials and Methods: Fluence patterns, shaped as a wedge with 10 steps (segments) by a multi-leaf collimator (MLC), of reference and test IMRT fields were measured using EDR2 film, the MatriXX, and EPID. Test fields were designed to simulate leaf positioning errors. The absolute dose at a point in each step of the reference fields was measured in a water phantom with an ionization chamber and was compared to the dose obtained with the use of EDR2 film, the MatriXX and EPID. For qualitative analysis, all measured fluence patterns of both reference and test fields were compared with calculated dose maps from a radiation treatment planning system (Pinnacle, Philips, USA) using profiles and $\gamma$ evaluation with 3%/3 mm and 2%/2 mm criteria. By measurement of the time to perform QA, we compared the workload of EDR2 film, the MatriXX and EPID. Results: The percent absolute dose difference between the measured and ionization chamber dose was within 1% for the EPID, 2% for the MatriXX and 3% for EDR2 film. The percentage of pixels with $\gamma$%>1 for the 3%/3 mm and 2%/2 mm criteria was within 2% for use of both EDR2 film and the EPID. However, differences for the use of the MatriXX were seen with a maximum difference as great as 5.94% with the 2%/2 mm criteria. For the test fields, EDR2 film and EPID could detect leaf-positioning errors on the order of -3 mm and -2 mm, respectively. However it was difficult to differentiate leaf-positioning errors with the MatriXX due to its poor resolution. The approximate time to perform QA was 110 minutes for the use of EDR2 film, 80 minutes for the use of the MatriXX and approximately 55 minutes for the use of the EPID. Conclusion: This study has evaluated the accuracy and efficacy of EDR2 film, the MatriXX and EPID in the pre-treatment verification of IMRT. EDR2 film and the EPID showed better performance for accuracy, while the use of the MatriXX significantly reduced measurement and analysis times. We propose practical and useful methods to establish an effective QA system in a clinical environment.

Feasibility of MatriXX for Intensity Modulated Radiation Therapy Quality Assurance (세기변조방사선치료의 품질관리를 위한 이온전리함 매트릭스의 유용성 고찰)

  • Kang, Min-Young;Kim, Yoen-Lae;Park, Byung-Moon;Bae, Yong-Ki;Bang, Dong-Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.91-97
    • /
    • 2007
  • Purpose: To evaluate the feasibility of a commercial ion chamber array for intensity modulated radiation therapy (IMRT) quality assurance (QA) was performed IMRT patient-specific QA Materials and Methods: A use of IMRT patient-specific QA was examined for nasopharyngeal patient by using 6MV photon beams. The MatriXX (Wellhofer Dosimetrie, Germany) was used for IMRT QA. The case of nasopharyngeal cancer was performed inverse treatment planning. A hybrid dose distribution made on the CT data of MatriXX and solid phantom all of the same gantry angle (0$^\circ$). The measurement was acquired with geometrical condition that equal to hybrid treatment planning. The $\gamma$-index (dose difference 3%, DTA 3 mm) histogram was used for quantitative analysis of dose discrepancies. An absolute dose was compared at the high dose low gradient region. Results: The dose distribution was shown a good agreement by gamma evaluation. A proportion of acceptance criteria was 95.8%, 97.52%, 96.28%, 98.20%, 97.78%, 96.64% and 92.70% for gantry angles were 0$^\circ$, 55$^\circ$, 110$^\circ$, 140$^\circ$, 220$^\circ$, 250$^\circ$ and 305$^\circ$, respectively. The absolute dose in high dose low gradient region was shown reasonable agreement with the RTP calculation within $\pm$3%. Conclusion: The MatriXX offers the dosimetric characteristics required for performing both relative and absolute measurements. If MatriXX use in the clinic, it could be simplified and reduced the IMRT patient-specific QA workload. Therefore, the MatriXX is evaluated as a reliable and convenient dosimeter for IMRT patient-specific QA.

  • PDF

Measurement of Ventilatory Threshold in the Patients with Chronic Airway Obstruction (만성기도폐쇄를 보이는 환자에서 환기성역치 측정)

  • Lee, Kye-Young;Jee, Young-Koo;Kim, Keun-Yeol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.309-320
    • /
    • 1997
  • Background : There are many suggested methods for the indirect determination of anaerobic threshold(AT) using the changes of ventilatory parameters in response to ventilatory load accompanying the increase of blood lactic acid level during exercise and the threshold derived from them is called ventilatory threshold(VT). They include ventilatory equivalent method(VEM), End-tidal $PO_2$ method($PETO_2$). V-slope method(VSM), and respiratory quotient method(RQ). But in the patients with chronic airway obstruction(CAO), the AT determined by ventilatory methods may not reflect true AT because the patients with CAO show inadequate ventilatory response to the increase of blood lactic acid level during excercise. Methods : For the investigation of detection rate and reliability of above four VT determination methods in the patients with CAO, we performed the symptom-limited and maximal incremental exercise test in 17 patients with CAO and 12 normal controls. The incremental workload was 10 W /min in CAO group and 25 W/min in control group. The reliability of VT in each group was investigated by the calculation of Spearman correlation coefficient. Results : The detection rates of VT were 100% by RQ, 91.7% by both VEM and $POETO_2$, and 83.3% by VSM in normal control group, while 94.1% by RQ, 64.7% by VEM and $PETO_2$, and 83.3% by VSM in CAO group. Good correlations were noted among VEM, $POETO_2$, and VSM except RQ in normal control group. But there was no significant correlation except between VEM and $PETO_2$ in CAO group. Conclusions : RQ is very sensitive but crude and VEM is near similar to $PETO_2$. The clinical usefulness of VT determined by ventilatory method might be limited in patients with severe CAO.

  • PDF