• Title/Summary/Keyword: working gas

Search Result 708, Processing Time 0.023 seconds

Preparing of the AI electrode for OLED by Sputtering Methode (스퍼터링법을 이용한 OLED용 Al 전극의 제작)

  • Kim, Kyung-Hwan;Keum, Min-Jong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.72-75
    • /
    • 2005
  • In this study Al electrode for OLED was deposited by FTS(Facing Targets Sputtering) system which can deposit thin films with low substrate damage. The Al thin films were deposited on the cell(LiF/EML/HTL/Bottom electrode) as a function of working gas such as Ar, Kr or mixed gas. Also Al thin films were prepared with working gas pressure (1, 6 mTorr ). The film thickness and I-V curve of Al/cell were evaluated by $\alpha$-step and semiconductor parameter (HP4156A) measurement. In the results, when Al thin film were deposited using pure Ar gas, the turn-on voltage of Al/cell was about 11[V]. And the turn-on voltage of Al/cell can be decrease to about 7[V].

  • PDF

Prediction of coal and gas outburst risk at driving working face based on Bayes discriminant analysis model

  • Chen, Liang;Yu, Liang;Ou, Jianchun;Zhou, Yinbo;Fu, Jiangwei;Wang, Fei
    • Earthquakes and Structures
    • /
    • v.18 no.1
    • /
    • pp.73-82
    • /
    • 2020
  • With the coal mining depth increasing, both stress and gas pressure rapidly enhance, causing coal and gas outburst risk to become more complex and severe. The conventional method for prediction of coal and gas outburst adopts one prediction index and corresponding critical value to forecast and cannot reflect all the factors impacting coal and gas outburst, thus it is characteristic of false and missing forecasts and poor accuracy. For the reason, based on analyses of both the prediction indicators and the factors impacting coal and gas outburst at the test site, this work carefully selected 6 prediction indicators such as the index of gas desorption from drill cuttings Δh2, the amount of drill cuttings S, gas content W, the gas initial diffusion velocity index ΔP, the intensity of electromagnetic radiation E and its number of pulse N, constructed the Bayes discriminant analysis (BDA) index system, studied the BDA-based multi-index comprehensive model for forecast of coal and gas outburst risk, and used the established discriminant model to conduct coal and gas outburst prediction. Results showed that the BDA - based multi-index comprehensive model for prediction of coal and gas outburst has an 100% of prediction accuracy, without wrong and omitted predictions, can also accurately forecast the outburst risk even for the low indicators outburst. The prediction method set up by this study has a broad application prospect in the prediction of coal and gas outburst risk.

Dynamic Ductile Fracture Analysis of Natural Gas Pipelines on the Basis of Material Grade and Charpy V-Notch Impact Energy (가스배관의 재질등급 및 충격에너지에 따른 연속연성파괴 거동분석)

  • Jeong, Hyo-Tae;Choe, Byung-Hak;Lee, Young-Jin;Lee, Jeong-Hwa;Hong, Key-Yong;Baek, Jong-Hyeon;Kim, Woo-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.5
    • /
    • pp.35-40
    • /
    • 2012
  • To analyze the macroscopic fracture behavior as functions of the gas pipeline grade and the working environment, following analyses have been accomplished. Computer analysis of changes in fracture behaviors according to the working conditions of pipelines and Analysis of dynamic ductile fracture behaviors using the Battelle Two Curve Method. Recently, an economic and reliable pipe materials with improved performance has been needed for the severe pipeline working condition and new transporting materials. As the grade of pipe materials became higher, the possibility of dynamic ductile fracture could be increased. Therefore, the understanding of the technology to control and arrest the dynamic ductile fracture is important.

Experimental Study on the Safety of Portable Butane Gas Range (휴대용 부탄 가스 레인지의 안전성에 관한 실험적 연구)

  • Keum, Kuk Bin;Kim, Do-Hyun;Kum, Sungmin;Lee, Chang-Eon;Kim, Young-gu
    • Journal of the Korean Society of Combustion
    • /
    • v.22 no.2
    • /
    • pp.50-56
    • /
    • 2017
  • This study was conducted an experiment for the thermal flow mechanism of the surrounding butane gas can and pressure change in butane can with oversized cookware. And numerical analysis was performed to analyze the process of heat transfer around butane can. Effect of radiant heat from small size cookware is very small. Thus small size cookware does not have a significant impact on the butane gas range safety. But radiant heat of oversized cookware is larger than small size cookware. Therefore it gives an adverse effect on the butane can. And when internal pressure of butane can is greater than about 406.8~447.2 kPa, a safety device of portable butane gas range were working. The causes of safety device working is because of trivet height. Trivet height is lowered, the radiant heat is increased. This radiant heat is to raise pressure of inside butane can. Experimental and numerical analysis results, the lower thermal conductivity of the cookware is greater the effects of radiant heat.

Experimental Research on an Organic Rankine Cycle Using Engine Exhaust Gas (엔진 배기열 이용 유기랭킨사이클에 대한 실험적 연구)

  • Shin, Dong Gil
    • Journal of Energy Engineering
    • /
    • v.21 no.4
    • /
    • pp.393-397
    • /
    • 2012
  • In this study, an organic Rankine cycle(ORC) for gas engine waste heat recovery for industry has been constructed and a performance analysis test has been carried out. Shell & tube style heat exchanger has been equipped on an engine exhaust manifold in order to absorb heat of engine exhaust gas into the working fluid(refrigerant R134a). Under 60 kW of engine power output, about 63 kW of engine exhaust gas heat was discharged and the proportion of heat recovered was 68~73% while 43~46 kW of heat was absorbed into working fluid. Consequently rated power output of ORC was 4.6 kW while the ratio of rated power output to engine exhaust gas heat was 7.3%.

A Study on Improvement of the Physical Properties of 4 Component Working Fluid in Gas Fired Absorption Chillers (가스흡수식 냉방기용 4성분계 작동매체의 물성 향상 연구)

  • Baek, Young-Soon;Oh, Young-Sam;Lee, Yong-Won;Park, Dal-Ryung;Koo, Ki-Kap
    • Applied Chemistry for Engineering
    • /
    • v.10 no.3
    • /
    • pp.400-406
    • /
    • 1999
  • In an effort to obtain high efficiency in gas fired absorption chillers, a new working fluid has been developed with thc addition of the component of $LiNO_3$, LiCl and LiI to the conventional solution of $LiBr-H_2O$. The solubility and vapor pressure of the 4 component working fluid developed in this work were measured and compared to the results of $LiBr-H_2O$ solution. It was observed that there exists an optimal mole ratio of the inorganic salts in terms of solubility. The mole ratio of LiBr, $LiNO_3$ and LiCl was found to be around 5:1:1~2 in the $LiBr-LiNO_3-LiCl-H_2O$ mixture, and in the case of $LiBr-LiO_3-Lil-H_2O$ and $LiBr-Lil-LiCl-H_2O$ mixtures, the mole ratio of LiBr, $LiNO_3$ and Lil/ LiBr, LiI and LiCl were found to be around 5:1:1 and 5:1:0.5~1 respectively. The vapor pressure of the 4 component working fluid of the optimal mole ratio was increascd with adding the component of $LiNO_3$, LiCl and LiI except for $LiBr-LiNO_3-LiCl-H_2O$ mixture. The absorption capacity of $LiBr-LiNO_3-LiCl-H_2O$ mixture was obtained higher than that of $LiBr-H_2O$ mixture.

  • PDF

A Study on the Performance of Thermal Mass Flowmeter (열량형 질량 유량계의 성능 평가)

  • Choi, Y.M.;Park, K.A.;Yoon, B.H.;Jang, S.;Choi, H.M.;Lee, S.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.595-600
    • /
    • 2001
  • Thermal mass flow meter(TMF) and thermal mass flow controller(MFC) were used to measure and to control the mass flow rate of gases. TMF and MFC were designed for specified working pressure and gas. For the case of different working pressure and gases, the flow rate measurement accuracy decreased dramatically. In this study, a TMF and MFC was tested with three different gases and pressure range from 0.2 MPa up to 1.0 MPa. Effect of specific heat causes to increase flow measurement error as much as ratio of specific heat compared with reference gas. Changing of pressure causes to increase flow rate measurement error about -0.2% as the working pressure decreased 0.1 MPa. Response time of MFC was below 3.12 s for the case of increasing of flow rate. But the response time was increased up to 6.92 s for the case of decreasing of flow rate. When the solenoid valve was fully closed, a initial delay time of output of MFC was increased up to 1.36 s.

  • PDF

LC Alignment Effects using a-C:H Thin Film as Working Gas at Bias Condition (바이어스 조건하에서 증착한 a-C:H 박막을 이용한 액정 배향 효과)

  • Jo, Yong-Min;Hwang, Jeoung-Yeon;Park, Chang-Joon;Seo, Dae-Shik;Rho, Soon-Jun;Ahn, Han-Jin;Baik, Hong-Koo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.136-139
    • /
    • 2003
  • We studied the nematic liquid crystal (NLC) aligning capabilities using the new alignment material of a-C:H thin film as working gas at 30W rf bias condition. A high pretilt angle of about $5^{\circ}$ by ion beam(IB) exposure on the a-C:H thin film surface was measured. A good LC alignment by the IB alignment method on the a-C:H thin film surface was observed at annealing temperature of $250^{\circ}C$, and the alignment defect of the NLC was observed above annealing temperature of $300^{\circ}C$. Consequently, the high LC pretilt angle and the good thermal stability of LC alignment by the IB alignment method on the a-C:H thin film surface as working gas at 30W rf bias condition can be achieved.

  • PDF

Preparation of Al electrode with Ar-Kr gas mixture for OLED application (Ar-Kr 혼합가스를 이용한 OLED용 Al 전극 제작)

  • Kim, Sang-Mo;Jang, Kyung-Wook;Lee, Won-Jae;Kim, Kyung-Hwan
    • Journal of the Semiconductor & Display Technology
    • /
    • v.6 no.4
    • /
    • pp.11-15
    • /
    • 2007
  • As preparing electrode for the OLED with the sputtering process, in order to be lower damage of the bottom organic layer and increase the life-time of the OLED, we prepared Al electrode for that by using Facing Targets Sputtering (FTS) system. Al electrode directly deposited on the cell (LiF/EML/HTL/Bottom electrode). Deposition condition was the working gas (Ar, Kr and Ar+Kr) and working gas pressure (1 and 6 mTorr). The film thickness and I-V curve of Al/cell were evaluated by a $\acute{a}$-step profiler and a semiconductor parameter (HP4156A) measurement. The thin film surface image was observed by a Atomic Force Microscope (AFM). In result, in comparison with about 11 [V] of the turn-on voltage of Al/cell with using the pure Ar gas, when Al thin film was deposited using the Ar-Kr mixture gas, the surface morphology was improved in some region and the turn-on voltage of Al/cell could be decreased to about 7 [V].

  • PDF

Thermodynamic Analysis on Organic Rankine Cycle Using Exhaust Gas of the Chimney in a Resource Recovery Facility (폐기물 소각시설 굴뚝의 배기가스를 이용한 유기랭킨사이클 시스템의 열역학적 해석)

  • Kim, Sunhee;Sung, Taehong;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.5
    • /
    • pp.27-35
    • /
    • 2017
  • The amount and quality of waste heat from a resource recovery facility were measured. The temperature of exhaust gas was $176.6^{\circ}C$ and the amount of that was 13.8 kg/s. This research designed a waste heat recovery system whose working fluid is R-245fa. It simulated three study cases as follows. In simulation of a basic ORC system, the turbine power output and thermal efficiency were respectively 96.56 kW, 14.3%. In simulation of a superheater connection, 0.09% of efficiency could be improved due to the increase of enthalpy by overheating of working fluid, but the obtained output was decreased with 16.58kW because of the decrease of working fluid mass. In simulation of a process heater connection, efficiency was increased up to 38.51%.