• 제목/요약/키워드: withstand surge energy

검색결과 4건 처리시간 0.018초

전력용 피뢰기의 임펄스에 의한 파손과 대척 기술 (Fracture and Protection Technologies against Impulse of Power Arresters)

  • 한세원;조한구;김석수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.190-193
    • /
    • 2001
  • ZnO varistors have been widely used to protect power system and electronic system against overvoltages based on their excellent nonlinearity. In order to increase their protection capability, the fracture and protection technologies of arresters have to study according to their applications, namely ImA DC voltage, leakage currents, impulse residual voltages, withstanding capability to impulse surge, and energy absorption capability. ZnO varistors which have nonlinear current-voltage characteristic name a number of failure mechanism when ZnO elements absorb surge energies. Failure mode by thermal stress and Pin hole are among the most common failure mechanism at the high current surge current. In this study, the fracture mechaism of power arresters are introduced and protection technologies are researched. In particular the effect of thermal stress by surge currents to ZnO elements and methods against arc surge energy through withstand structure design of arrester are discussed.

  • PDF

전지관리장치(BMS)의 서지내성 성능향상 기법 (Surge Immunity Performance Enhancement Techniques on Battery Management System)

  • 김용성;임성정;서우현;정중일
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.196-200
    • /
    • 2015
  • The switching noise in the power electronics of the power conversion equipment (Power Conditioning System) for large energy storage devices are generated. Since the burst-level transient noise from being generated in the power system at a higher power change process influences the control circuit of the low voltage driver circuit. Noise may cause the malfunction of the control device even if no dielectric breakdown leads to a control circuit. To overcome this, this paper proposes the installation of an additional nano-surge protection device on the power supply DC output circuit of the battery management unit.

협조된 SPD시스템에서 접속선의 길이가 에너지협조에 미치는 영향 (Influences of the Length of Connecting Leads on the Energy Coordination in Coordinated SPD Systems)

  • 이복희;신희경
    • 조명전기설비학회논문지
    • /
    • 제28권6호
    • /
    • pp.91-98
    • /
    • 2014
  • For the purpose of designing and applying the optimum surge protection scheme, multi-stage coordinated surge protective device(SPD) system is suitable to successfully fulfill its tasks; first, to divert a large amount of the transient energy, second, to clamp the overvoltage to the level below the withstand impulse voltage of the equipment to be protected. The length of SPD connecting leads shall be as short as possible. Long connecting leads will degrade the protection effect of SPDs. In this paper, the influences of the length of connecting leads on the energy sharing in a coordinated SPD system were investigated experimentally, and the simulation of determining the energy sharing and protection voltage level of each SPD depending on the length of connecting leads was carried out by using P-spice program. It was confirmed that the protection voltage level and energy sharing in coordinated SPD systems are strongly influenced by the length of connecting leads.

희토류 금속 산화물 첨가에 따른 ZnO varistor의 전기적 특성 (Electrical properties of the ZnO varistors with the amount of rare-earth metal oxide addition)

  • 조현무;이종덕;박상만
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.336-337
    • /
    • 2005
  • ZnO varistor ceramics were fabricated as a function of the amount of $Y_2O_3$ addition and sintered at $1250^{\circ}C$ for 2 hour. The average grain size was decreased from 14.2 ${\mu}m$ to 8.3 ${\mu}m$ with the amount of $Y_2O_3$ addition, and varistor voltage was increased from 433 V to 563 V with $Y_2O_3$ addition. Nonlinear coefficient a of all specimens were increased with the amount of $Y_2O_3$ more than 67, in case of $Y_2O_3$ 0.01wt% addition showed the excellent results of 87. And leakage current was less than $1{\mu}A$ at 82% of varistor voltage. The clamping voltage ratio of the specimens added 0.01wt% $Y_2O_3$ was 1.41 at 25A [8/20${\mu}s$]. At the specimen 0.01wt% $Y_2O_3$ addition. endurance of surge current and deviation of varistor voltage were 5700A/$cm^2$ and $\Delta$-2.86%, respectively.

  • PDF