• Title/Summary/Keyword: without replacement

Search Result 764, Processing Time 0.023 seconds

Performance Analysis of Adaptive Partition Cache Replacement using Various Monitoring Ratios for Non-volatile Memory Systems

  • Hwang, Sang-Ho;Kwak, Jong Wook
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.4
    • /
    • pp.1-8
    • /
    • 2018
  • In this paper, we propose an adaptive partition cache replacement policy and evaluate the performance of our scheme using various monitoring ratios to help lifetime extension of non-volatile main memory systems without performance degradation. The proposal combines conventional LRU (Least Recently Used) replacement policy and Early Eviction Zone (E2Z), which considers a dirty bit as well as LRU bits to select a candidate block. In particular, this paper shows the performance of non-volatile memory using various monitoring ratios and determines optimized monitoring ratio and partition size of E2Z for reducing the number of writebacks using cache hit counter logic and hit predictor. In the experiment evaluation, we showed that 1:128 combination provided the best results of writebacks and runtime, in terms of performance and complexity trade-off relation, and our proposal yielded up to 42% reduction of writebacks, compared with others.

Comparison Analysis of Effectiveness of CPM and PNF Treatments after Total Knee Replacement (슬관절 전치환술 시행 후 CPM과 PNF 치료에 따른 효과 비교)

  • Choi, In-soo;Bae, Sung-soo
    • PNF and Movement
    • /
    • v.2 no.1
    • /
    • pp.13-23
    • /
    • 2004
  • Objective : Compare the results of CPM and PNF in recovery rates when applied as an initial physical therapy. Methods : Randomly selected 19 patients who underwent through total knee replacement surgery. 23 cases were studied and divided into 12 CPM and 11 PNF cases. CPM case was carried out for 60 minutes, a maximum allowed exercise without pain. PNF case was carried out for 20 minutes by a therapist to a patient as 'one on one'. Result : Result showed that PNF treatment was increased significantly at P<0.05 in flexor muscle strength in 8 days after the surgery. Conclusion : The study revealed that in comparison with CPM, PNF was more effective treatment increase of flexor muscle strength in rehabilitation on after total knee replacement surgery.

  • PDF

Axial compressive behavior of partially encased recycled aggregate concrete stub columns after exposure to high temperatures

  • Jiongfeng Liang;Wanjie Zou;Liuhaoxiang Wang;Wei Li
    • Steel and Composite Structures
    • /
    • v.52 no.2
    • /
    • pp.121-134
    • /
    • 2024
  • To investigate the compressive behavior of partially encased recycled aggregate concrete (PERAC) stub columns after exposed to elevated temperatures, 22 specimens were tested. The maximum temperature suffered, the replacement ratio of recycled coarse aggregate (RCA), the endurance time and the spacing between links were considered as the main parameters. It was found that the failure mode of post-heated PERAC columns generally matched that of traditional partially encased composite (PEC) columns, but the flange of specimens appeared premature buckling after undergoing the temperature of 400℃ and above. Additionally, the ultimate strength and ductility of the specimens deteriorated with the elevated temperatures and extended heating time. When 400℃< T ≤ 600℃, the strength reduction range is the largest, about 11% ~ 17%. The higher the replacement ratio of RCA, the lower the ultimate strength of specimens. At the temperature of 600℃, the ultimate strength of specimens with the RCA replacement ratio of 50% and 100% is 0.94 and 0.91 times than that of specimens without RCA, respectively. But the specimen with 50% replacement ratio of RCA showed the best ductility performance. And the bearing capacity and ductility of PERAC stub columns were changed for the better due to the application of links. When the RCA replacement ratio is 100%, the ultimate strength of specimens with the link spacing of 100 mm and 50 mm increased 14% and 25% than that of the specimen without links, respectively. Based on the results above, a formula for calculating the ultimate strength of PERAC stub columns after exposure to high temperatures was proposed.

Annual Open Heart Surgery: Report of 416 Cases in 1980 (연간 개심술 416례 보고 [1980 년도])

  • 이영균
    • Journal of Chest Surgery
    • /
    • v.14 no.1
    • /
    • pp.17-25
    • /
    • 1981
  • In 1980, 416 cases of open heart surgery were done in this Department with over all operative mortality of 12.3%. 1. There were 288 congenital anomalies consisting of 174 acyanotic and 114 cyanotic varieties, which showed operative mortality of 6.9% and 25.4% respectively. 2. There were 128 cases of acquired lesions, 124 valvular disease and 3 myxoma being the main lesions. 3. There were 128 cases of valve replacement with operative mortality of 7.8%. 4. The most frequently operated anomaly was VSD, 90 pure VSD and 21 cases were associated with one or 2 cardiac anomalies. Over all operative mortality in 111 VSD cases was 8.1% but in 90 pure VSD cases it was 6.7%. 5. Tetralogy of Fallot showed the highest incidence in cyanotic group with 88 cases, consisting of 68 pure and 20 with other cardiac anomalies. Over all mortality in 88 cases was 19.3% but in pure form 16.2%. 6. In 128 valve replacement cases over all mortality was 9.4%. There were 85 mitral, 11 aortic, 2 tricuspid, 21 mitral with aortic, 6 mitral with tricuspid, 3 mitral, aortic, and tricuspid valve replacement cases. For mitral valve replacement operative mortality was 5.9%. 7. Twenty-one cases of babies under 10kg body weight were operated on with over all operative mortality of 28.6%. Sixteen cases of VSD were found with operative mortality of 25%. 8. Among 128 cases of valve replacement 7 were under the age of 15 years and 12 were between 15 and 20 years old. Five pediatric cases underwent mitral valve replacement without mortality, 9 year old boy was the youngest among them. In this Department open heart surgery for infancy and complex anomalies showed still hip operative risk which should be improved in the coming years. For open heart surgery Shiley oxygenators and 2 sets of A-O de-lux 5 head roller pump were utilized exclusively. For valve replacement Ionescu-Shiley bovine pericardial xenografts were mainly used. In pediatric and rural patients Persantin with aspirin regimen was satisfactorily administered for anticoagulation after valve replacement. Routinely Coumadin was administered for one year after valve replacement* In patients who had thrombus on valve sites, chronic atrial fibrillation, and giant left atrium Persantin-Aspirin regimen was used when one year coumadin administration was discontinued.

  • PDF

Clinical study of myocardial preservation (심근보호에 대한 임상적 고찰)

  • Jo, Jae-Il;Lee, Yeong-Gyun
    • Journal of Chest Surgery
    • /
    • v.17 no.4
    • /
    • pp.557-564
    • /
    • 1984
  • Of the valve replacement patients operated between 1983 and June, 1984, 75 patients need more than 60 minutes of aortic cross-clamping time. 42 patients performed single valve replacement [35 MVR, 7 AVR with or without TAP] and remainder needs double valve replacement with or without TAP. The average aortic clamping time was 95.1 minutes. They need 30 minutes more extra-corporeal circulation time than aortic clamping time. The patients were divided into two groups by usage of cardioplegic solution. Group I [n=31] with Bretschneider solution and group II with potassium cardioplegic solution [M.G.H. modification] were analyzed by extra-corporeal circulation data,/CG and Echocardiography findings, and clinical data. There was no difference between two groups in Bivon addition amounts [cc/kg] and E.F. and S.F. by echocardiography, group I need 1 more electrocardioversion to convert sinus rhythm postoperatively. Also no difference could be found in patients whose preoperative C.I. was above 2.0 between two group. But significant postoperative decrease in E.F. was found in group I whose preoperative C.I. was below 2.0. Relatively longer ECC time was also needed in same group. Ischemic changes in ECG and low cardiac output syndrome was, however more prevalent in groupII. As a whole, the clinical data was satisfactory with both cardioplegic solution in clinical practice.

  • PDF

Properties of the high strength and self-compacting concrete according to the replacement ratio of fly ash (플라이애쉬의 치환율에 따른 고강도 자기충전 콘크리트의 특성)

  • Kwon, Yeong-Ho;Lee, Hyun-Ho;Lee, Hwa-Jin;Ha, Jae-Dam
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.85-88
    • /
    • 2006
  • This study describes the optimum mix proportion of the high strength and self-compacting concrete placed in main structures of LNG above tank. This concrete requires high strength level about $60{\sim}80MPa$, low hydration heat, balance between workability and consistency without vibrating in the actual work. For this purpose, low heat portland cement and fly ash are selected and design factors including water-binder ratio, replacement ratio of fly ash are tested. As experimental results, low heat portland cement shows lower the confined water ratio than another cement type and the optimum replacement ratio of fly ash in order to improve properties of the binder-paste shows 10% by cement weight considering test results of the confined water ratio$({\beta}p)$. Also, flowability of the high strength and self-compacting concrete by using fly ash about $10{\sim}20%$ is improved. The replacement ratio of fly ash 10% and water-binder ratio $25{\sim}27%$ are suitable to the design strength 80MPa and cost, In case of the design strength 60MPa, the replacement ratio of fly ash and water-binder ratio show 20% and $25{\sim}30%$ separately. Based on the results of this study, the optimum mix proportions of the high strength and self-compacting concrete will be applied to the construction of LNG above tank as a new type.

  • PDF

Effects of Partial Beef Fat Replacement with Gelled Emulsion on Functional and Quality Properties of Model System Meat Emulsions

  • Serdaroglu, Meltem;Nacak, Berker;Karabiyikoglu, Merve;Keser, Gokcen
    • Food Science of Animal Resources
    • /
    • v.36 no.6
    • /
    • pp.744-751
    • /
    • 2016
  • The objective of this study was to investigate the effects of partial beef fat replacement (0, 30, 50, 100%) with gelled emulsion (GE) prepared with olive oil on functional and quality properties of model system meat emulsion (MSME). GE consisted of inulin and gelatin as gelling agent and characteristics of gelled and model system meat emulsions were investigated. GE showed good initial stability against centrifugation forces and thermal stability at different temperatures. GE addition decreased the pH with respect to increase in GE concentration. Addition of GE increased lightness and yellowness but reduced redness compared to control samples. The results of the study showed that partial replacement of beef fat with GE could be used for improving cooking yield without negative effects on water holding capacity and emulsion stability compared to C samples when replacement level is up to 50%. The presence of GE significantly affected textural behaviors of samples (p<0.05). In conclusion, our study showed that GE have promising impacts on developing healthier meat product formulations besides improving technological characteristics.

The Effects of Sit-to-Stand Training with Visual Feedback on the Strength and Balance Ability Patients with Total Knee Replacement (시각적 되먹임의 제공에 따른 일어서기 훈련이 무릎관절 전치환술 환자의 다리 근력과 균형 능력에 미치는 영향)

  • Park, Jin;Park, Han-Kyu
    • PNF and Movement
    • /
    • v.19 no.1
    • /
    • pp.9-17
    • /
    • 2021
  • Purpose: This study aims to verify the effectiveness of sit-to-stand training with visual feedback to improve balance ability and knee extensor strength of total knee replacement patients. Methods: In this study, 15 patients with total knee replacement participated in this study. Subjects were assigned to two groups: a feedback group (experimental group)(n = 8) and a control group (n = 7). They all received 30 min of continuous passive motion (CPM) and sit-to-stand training for 15 min five times per week for two weeks. Knee extensor and balance ability were measured. Knee extensor was measured by Biodex system 3; balance ability was measured by Balancia software. Results: After the intervention, there was a significant difference in the strengthening of the knee extensor muscles in the feedback group, area 95%, weight distribution of the affected side, and the sit-to-stand test repeated five times (p < 0.05). Conclusion: The results of this study showed that sit-to-stand training with visual feedback was more effective in increasing knee extensor muscle strength and balance ability than the sit-to-stand training without visual feedback. Therefore, in order to improve the knee extensor muscle and the balance of total knee replacement patients, it is necessary to consider providing visual feedback during sit-to-stand training.

Control Charts for Constant Failure Rate of System

  • Cho, Gyo-Young;Lee, Ok-Hee
    • Journal of the Korean Data and Information Science Society
    • /
    • v.13 no.2
    • /
    • pp.147-156
    • /
    • 2002
  • In this paper, we propose EWMA control charts using the life time data for the system with the constant failure rate, which were drawn from the fixed sampling interval without replacement(with replacement), and investigate the power of detection of EWMA by comparing ARL of EWMA control charts with one of Shewhart control charts.

  • PDF

Control Charts for Constant Failure Rate of System

  • Cho, Gyo-Young;Lee, Ok-Hee
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 2002.06a
    • /
    • pp.141-149
    • /
    • 2002
  • In this paper, we propose EWMA control charts using the life time data for the system with the constant failure rate, which were drawn from the fixed sampling interval without replacement (with replacement), and investigate the power of detection of EWMA by comparing ARL of EWMA control charts with one of Shewhart control charts.

  • PDF