• Title/Summary/Keyword: without fire protection

Search Result 104, Processing Time 0.027 seconds

Measures to Increase Evacuation Safety through Performance-Based Design of Escape Room Cafes (방탈출카페의 성능위주설계에 의한 피난안전성 확대 방안)

  • Hong-Sang Lee;Jai Young Lee;Ha-Sung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.4
    • /
    • pp.95-104
    • /
    • 2023
  • The purpose of this study is to propose measures to increase evacuation safety by calculating the habitable time using a fire and evacuation simulation program for the Room-escape cafe currently in operation, and comparing and analyzing it with the evacuation required time. Assuming a fire due to overheating of electric heaters in use in front of the warehouse, the habitable time was calculated through fire simulation, and the occupant's evacuation time calculated through evacuation simulation according installation of safety facilities, etc. was compared and analyzed with the habitable time. In the case of escape room cafes with safety facilities installed, evacuation safety was satisfied, but in escape room cafes without safety facilities, the evacuation safety was not secure. As a result of analyzing evacuation safety for each scenario based on the ASET analyzed in the fire simulation, it was found that in scenario 1, evacuation safety was secured and everyone successfully evacuated, while in scenario 2, no one succeeded in evacuation. These results can be said to confirm that the installation of safety facilities is very important in business establishments such as escape room cafes, which become enclosed structures when games are started.

Study on Guideline of Water Supply System for Forest Fire (산불방지 급수시설 설치 기준 마련에 관한 연구)

  • Kim, Dong-Hyun;Nam, Song-Hee;Keum, Si-Hoon
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.38-46
    • /
    • 2013
  • Permanent water supply and water sprinkling systems are essential to protect major forests and facilities from forest fire. Back in 2005, Naksan Temple, a valuable cultural asset of Korea, was burned down in a forest fire that took place in Yangyang. This started a series of movements including installing water supply facilities and managing forests near important cultural assets. As for the existing facilities, however, they were installed without any standard guidelines for management and installation according to each constructor's specifications, which were based on the National Fire Safety Code 109. Unfortunately, this is not effective in protecting facilities from forest fires such as they have a small protection area, limited simultaneous sprinkling, and a difficult the movement of fire hose. Against this background, the study examines the condition of water supply facilities currently in use, identifies their deficiencies, and suggests how to improve the criteria for water supply service to effectively prevent forest fire. Specifically, three systems were proposed: Water Sprinkler Tower System for preventing spread of crown fires, and Forest Fire Hydrant System and Portable Water Spray System to be effective for suppressing surface fires. In addition, the standards on the performance and components of water pumps are also suggested.

Study of the Effective Management and Care System on in-Use Fire Fighteris Turnout Gear (소방복 유지관리시스템의 효율화 방안)

  • Son, Bong-Sae;Choi, Kye-Youn
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.72-77
    • /
    • 2011
  • This study aims to provide fundamental information required to establish an efficient maintenance and management system for fire fighting clothing which takes into account the domestic fire protection environment and situation. There aren't any detailed regulations and appropriate pre-inspection systems which would be required for proper maintenance of fire fighting clothing, as well as any test methods to determine the life spans of fire fighting clothing properly. Thus, this study tries to analyze the problems in use of fire fighting clothing and its maintenance situation and summarize overseas maintenance situation for fire fighting clothing. As a result, it is found that domestic fire fighting clothing is washed, repaired, and stored without any systematic management regulations. It is also found that the life spans of fire fighting clothing are determined, based on part of overseas management regulations on fire fighting clothing. Therefore, it is imperative to set up efficient management regulations and test methods for fire fighting clothing which would be required for efficient use of the fire fighting budgets and the life safety of fire fighters.

A Study on Activation device of 119 Emergency Care (119구급대의 활성화 방안에 관한 연구)

  • Koh, Jae-Moon;Kim, Gyoung-Wan;Chung, Yong-Tai
    • The Korean Journal of Emergency Medical Services
    • /
    • v.11 no.1
    • /
    • pp.27-40
    • /
    • 2007
  • Even now, 119 rescue services have dissatisfactory aspects in operation, system and equipments as discussed above, It is the most urgent subject to systemize rescue services so that they can be suitable for our status, for we will make 21C welfare state come true before long. So, this author suggest that the followings have to be raised to activate 119 rescue service. 1) Bring up experts and offer high-quality rescue service 2) Prepare more up-to-date equipments 3) Operate transfer joint organizations 4) Promote the ability to meet with a press at the time of rescue service activities 5) Adjust regulations related to rescue services 6) Make up for a countermeasure to traffic accidents of ambulances 7) Adjust regulations making it mandatory to establish heliport at the target on hospitals more than a defined scale 8) Install more rescue service teams 9) Educate and train officials belonging to briefing rooms, where the officials with long experiences are arranged 10) Minimize the time for rescue team to reach fields 11) Establish legal protection system for rescue the team Nowadays, our country operates the department of fire fighting and rescue services without great difficulty, even though the circumstances are bad - insufficient members and the inferior circumstances. All of the fire fighting officials are given heavy duties in bad circumstances, and so are the team of rescue service. The rescue service team, taking charge of some emergency medical system, do a fire fighting inspection as a non-duty service, though they are scanty of sleep due to prevention and protection services of the fire fighting service team. But, they can not engage in rescue services completely and have to deal with miscellaneous duties. So they can not offer professional emergency medical services. But now, almost every fire fighting organization, belonging to National Emergency Management Agency, are separating rescue services, which shows a lot of good results. People recognize rescue services to get better and better gradually and the demands for this rescue services increase. So, this is the best time when rescue service teams should offer qualitative services rather than quantitative services. The people will recognize this rescue service team to be an organization sacrificing and serving for them. However well institutes and operation systems should be established, the rescue service team can not come true their aim without strong wills that they will serve and sacrifice themselves for people from their hearts. In addition, it is essential for the officials in charge of policies about emergency medical services to have a concernment on and practice the policy without failure.

  • PDF

Study on the Safety Standard Establishment of Halogen Clean Extinguishing Agents (할로겐화합물청정소화약제 안전기준 설정에 관한 연구)

  • Cho, Jung-Rae;Lee, Jong-Ho
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.22-33
    • /
    • 2018
  • The amount of halogen clean fire extinguishing agents has been increased by the excellent features of extinguishing, adaptability and no residue. On the other hand in situations without a hazard assessment and safety standard of agents, chemical accidents by the agents occurs frequently. This study was performed to propose the halogen clean agents' regulatory exposure limit and safety standard including the quantitative ventilation system with gas leak monitoring, hazard recognition and optimal personal protection selection through a literature review and experimental research.

A Study on the Risk of Organic Solvents for Underground Area under Construction Site through a Fire Accident Case (화재사고사례를 통해서 본 건설현장 지하공간에서의 유기용제의 위험성에 대한 연구)

  • Ahn, Byung-Joon;Jung, Ki-Hyuk;Lee, Jung-Suk;Rhim, Jong-Kuk
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.1
    • /
    • pp.9-17
    • /
    • 2018
  • In the consideration of the working conditions, which have several kinds of works operating at the same time, at construction sites, it is difficult to prevent industrial accidents. There are a number of works to employ flammable materials and hot works simultaneously operated without fire protection systems. It causes a huge fire and casualties. In this research to analyze an accident case, the reasonable prevention methods are suggested throughout the property tests for the organic solvents and the analysis of the behavior for vapour cloud in the underground area of the construction site.

Analysis of Safety Evacuation Rules for Elderly and Children in High rise Hotel

  • Yuanyuan Zhang;HaSung Kong
    • International journal of advanced smart convergence
    • /
    • v.13 no.3
    • /
    • pp.345-357
    • /
    • 2024
  • High rise hotels are densely populated and have complex ignition sources. Once a fire occurs, it can cause serious casualties and property damage. The impact of a fire is greater on special groups such as the elderly and children who move slowly. At present, research mainly focuses on the impact of high-rise building structures on evacuation consequences, but there is little research on the safety evacuation consequences of elderly and children in high-rise hotels, as well as the behavior of people in groups during the safety evacuation process. Therefore, we propose to use Pathfinder software to simulate three scenarios for the elderly and children in high-rise hotels. Scenario 1 involves arranging the elderly and children on higher floors, Scenario 2 involves arranging them on middle floors, and Scenario 2 involves arranging them on lower floors. We further provide three types of personnel pairing schemes for each scenario, namely: no one pairing, two people pairing, and three people pairing. Through simulation analysis, we found that placing elderly and children with lower mobility on lower floors resulted in the shortest safe evacuation time; The evacuation time for solo actions without companionship is the shortest, followed by two people in groups, and the safety evacuation time for three people in groups is the longest. Our research findings have significant implications for improving the evacuation efficiency of personnel in fire scenarios.

Analysis on the Impact of Draft Curtains on Hospital Building Fires

  • Xiaopei Liu;Hasung Kong
    • International journal of advanced smart convergence
    • /
    • v.13 no.3
    • /
    • pp.367-375
    • /
    • 2024
  • Draft curtains are an important tool to reduce the spread of fire smoke in buildings. This paper mainly studies the influence of draft curtains on smoke spread in a hospital outpatient building with a spacious hall. The outpatient building of a county hospital in China is taken as the research object, and a fire simulation model is established based on PyroSim software. Four scenarios are designed: no draft curtains in the hall, draft curtains with a length of 1.5m in the hall, draft curtains with a length of 2.0m in the hall, and draft curtains with a length of 2.5m in the hall. At the same time, considering the worst situation, only the main emergency exit is opened, while the remaining emergency exits and windows are all closed, and the fire-fighting facilities are not activated. The detection point is set at the open emergency exit, 1.8m above the ground. Through the simulation of four scenarios, the effect of draft curtains on smoke spread is discussed from four aspects: smoke layer height, temperature, visibility, and CO concentration. The results show that draft curtains have a significant impact on the spread of smoke in a hospital outpatient building with a spacious hall. The longer the draft curtains are, the better the smoke-blocking effect. It should be noted that in the actual design, the length of the draft curtains should be considered without affecting the evacuation of personnel.

A Study on the Improvement of Crisis Alerts of Disaster-related Crisis Management Standardized Manuals (재난 관련 표준매뉴얼의 위기경보 개선방안에 관한 연구)

  • Kim, Yong-Soon;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.126-133
    • /
    • 2018
  • Korea has been preparing and operating crisis management standardized manuals so that over 30 disaster types that need to be managed at the national level can be selected and systematically managed. This study analyzed the crisis alert levels of two standard manuals related to the case with reference to the contents of the Framework Act on the Management of Disaster and Safety and National Crisis Management Basic Guidelines. According to the Act and Guidelines, crisis alerts are issued before a crisis or disaster, but the criteria of crisis alerts of the two manuals showed that the national crisis had already occurred and the disaster occurred due to a marine vessel accident at the serious level. In addition, the results of timing of issuance of crisis alert were reviewed. If the signs can be identified, a crisis alert may be issued prior to the occurrence of the incident, but a crisis alert cannot be issued when an incident occurs without a sign. In the case of an incident where there are no signs, but there is a possibility of spreading to a national level disaster, the disaster management supervision agency could issue a crisis alert.

Development of Multipoint Simultaneous Full-duplex Team Communication Module for SCBA (SCBA 면체용 다자간 동시 양방향 팀 통신모듈 개발)

  • Kim, Si-Kuk;Choi, Su-Gil;Lim, Woo-Sub;Han, Yong-Taek
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.165-172
    • /
    • 2019
  • This study presents the design and manufacture of a self-contained breathing apparatus SCBA wireless communication module with a multipoint simultaneous full-duplex communication system to enable communication between team members wearing the SCBA system. It is necessary for fire-fighters to wear the SCBA system during extinguishing and rescue work at the fire site. Evaluation of the team communication module confirmed the feasibility of communication over more than 500 m in the test condition based on the line of sight. By implementing the Ad-hoc function, it was confirmed that the communication distance could be extended to 128 m by automatic routing up to 3 hoc. The vertical distance inside the building for successful communication was up to the 5th floor in the open staircase and up to the 3rd floor in the partitioned staircase. Furthermore, the performance testing of the communication module assuming a fire situation, confirmed that five team members correctly recognized the standard abbreviation of fire and wireless communication without a separate PTT key operation. In addition, the flame resistance was verified by exposing the module to a flame at 950 ± 50 ℃ for 5 s and then immediately extinguishing the flame.