• 제목/요약/키워드: within- and between-individual variation

검색결과 72건 처리시간 0.027초

Variation in trn-L/trn-V and trn-F/trn-T spacer regions of cpDNA in Abies koreana Wilson and A. nephrolepis Traut./Maxim

  • Kormutak, A.;Hong, Y.-P.;Kwon, H.-Y.;Kim, C.-S.
    • 한국산림과학회지
    • /
    • 제96권2호
    • /
    • pp.131-137
    • /
    • 2007
  • The first evidence has been provided about the variation within trnL-trnV and trnF-trnT spacer regions of cpDNAs in Korean fir and Manchurian fir, revealed by PCR-RFLP analysis. Four cpDNA haplotypes have accordingly been recognized by being analyzed using the trnL-trnV/Tru11 primer-enzyme combination and 3 haplotypes using the trnF-trnT/TagI combination, which exhibited inter and intraspecific variation. A total of 6 cpDNA haplotypes were recognized by pooling the PCR-RFLP variants observed in both combinations. Haplotypes 2 and 3 were common for both species investigated, whereas haplotypes 1, 4, and 5 were detected only in Korean fir and haplotype 6 was detected only in Manchurian fir. Although haplotypes 2 and 3 were common in both species, haplotype 2 was major haplotype for Korean fir and haplotype 3 was one of the 2 major haplotypes for Manchurian fir. Restricted occurrence of haplotype 4 in Mt. Halla and haplotype 5 in Mt. Jiri of the Korean fir may represent the existence of geographic isolation by the sea between them. Diagnostic potential of individual haplotypes in discriminating between the two species as well as between their populations is discussed.

Evaluation of clinical usefulness of reference interval of some selected hematological parameters in canine blood

  • Pak, Son-Il;Han, Ho-Jae
    • 대한수의학회지
    • /
    • 제44권4호
    • /
    • pp.649-653
    • /
    • 2004
  • To estimate the source of variance components for some hematological parameters and assess the utility of the conventional population-based reference interval, this study computed index of individuality for blood samples, which were from 13 dogs drawn once weekly for 4 consecutive weeks. Results were subjected to nested analysis of variance. For all parameters measured between-dog variations were greater than within-dog variation. Except for the parameters RBC and MCHC the index of individuality was <1.4. The low reliability coefficient and high index of individuality of ${\leq}0.8$ were found for the majority of hematological parameters. In practical term, the present study indicated that use of hemogram profiles alone in the evaluating clinical state of a single patient should be avoided because of their physiological or natural random variations, and that comparing a single measurement on the blood analytes from an individual dog to the conventional population-based reference range may be too insensitive to detect any significant changes in the blood components of that particular dog. A single measurement may not characterize an individual's average concentration of the parameters even shortterm period.

체외 순환시간의 경과에 따른 Heparin과 Protamine의 적정량에 관한 연구 (Adequate Heparin-protamine Neutralization on using Blood Cardioplegic Solution during Extracorporeal Circulation)

  • 변형섭
    • Journal of Chest Surgery
    • /
    • 제21권2호
    • /
    • pp.203-210
    • /
    • 1988
  • The clinical experience with the activated clotting time[A.C.T.] for the control of heparin and protamine therapy during cardiopulmonary bypass in 40 patients between April, 1987 and September, 1987 is reviewed retrospectively. All of patients used with cold blood potassium cardioplegia for myocardial protection under standard cardiopulmonary bypass, priming and perfusate techniques respectively. This study was divided into 2 groups of patients followed by cardiopulmonary bypass time. Twenty patients, within 60 minutes of cardiopulmonary bypass time[group A] were compared with twenty patients, from 60 to 120 minutes of cardiopulmonary bypass time[group B]. Using blood cardioplegia for myocardial protection, Author observed wide variation of A.C.T. in individual response to initial heparinization[2mg /kg] and no requirement of additional heparin during cardiopulmonary bypass until 120 minutes. Total heparin amount during cardiopulmonary bypass was not related to body weight and body surface area in the both groups. After cardiopulmonary bypass, amounts of protamine for neutralization of heparin were more required in group B.

  • PDF

A phylogenetic analysis of the Korean endemic species Paraphlomis koreana (Lamiaceae) inferred from nuclear and plastid DNA sequences

  • Eun-Kyeong HAN;Jung-Hyun KIM;Jin-Seok KIM;Chang Woo HYUN;Dong Chan SON;Gyu Young CHUNG;Amarsanaa GANTSETSEG;Jung-Hyun LEE;In-Su CHOI
    • 식물분류학회지
    • /
    • 제53권2호
    • /
    • pp.157-165
    • /
    • 2023
  • Paraphlomis koreana (Lamiaceae) was newly named and added to Korean flora in 2014. Paraphlomis belongs to the tribe Paraphlomideae, along with Ajugoides and Matsumurella. However, a recent study has suggested that P. koreana is morphologically similar to Matsumurella chinensis, making them difficult to distinguish from each other. Therefore, we aimed to examine the phylogenetic placement of P. koreana within the tribe and compare its genetic relationship with M. chinensis. We sequenced an additional complete plastid genome for an individual of P. koreana and generated sequences of nuclear ribosomal (nr) DNA regions of internal and external transcribed spacers (ITS and ETS) for two individuals of P. koreana. Maximum likelihood analyses based on two nrDNA regions (ITS and ETS) and four plastid DNA markers (rpl16 intron, rpl32-trnL, rps16 intron, and trnL-F) covering 13 Paraphlomis species and M. chinensis were conducted. Phylogenetic analyses concordantly supported that P. koreana forms a monophyletic group with M. chinensis. Moreover, our study revealed that P. koreana includes nrDNA sequences of M. chinensis as minor intra-individual variants, suggesting that the genetic divergence between the two taxa is incomplete and may represent intraspecific variation rather than distinct species. In conclusion, our findings suggest that the independent species status of P. koreana within Paraphlomis should be reconsidered.

Wine quality grading by near infrared spectroscopy.

  • Dambergs, Robert G.;Kambouris, Ambrosias;Schumacher, Nathan;Francis, I. Leigh;Esler, Michael B.;Gishen, Mark
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1253-1253
    • /
    • 2001
  • The ability to accurately assess wine quality is important during the wine making process, particularly when allocating batches of wines to styles determined by consumer requirements. Grape payments are often determined by the quality category of the wine that is produced from them. Wine quality, in terms of sensory characteristics, is normally a subjective measure, performed by experienced winemakers, wine competition judges or winetasting panellists. By nature, such assessments can be biased by individual preferences and may be subject to day-to-day variation. Taste and aroma compounds are often present in concentrations below the detection limit of near infrared (NIR) spectroscopy but the more abundant organic compounds offer potential for objective quality grading by this technique. Samples were drawn from one of Australia's major wine shows and from BRL Hardy's post-vintage wine quality allocation tastings. The samples were scanned in transmission mode with a FOSS NIR Systems 6500, over the wavelength range 400-2500 ㎚. Data analysis was performed with the Vision chemometrics package. With samples from the allocation tastings, the best correlations between NIR spectra and tasting data were obtained with dry red wines. These calibrations used loadings in the wavelengths related to anthocyanins, ethanol and possibly tannins. Anthocyanins are a group of compounds responsible for colour in red wines - restricting the wavelengths to those relating to anthocyanins produced calibrations of similar accuracy to those using the full wavelength range. This was particularly marked with Merlot, a variety that tends to have relatively lower anthocyanin levels than Cabernet Sauvignon and Shiraz. For dry white wines, calibrations appeared to be more dependent on ethanol characteristics of the spectrum, implying that quality correlated with fruit maturity. The correlations between NIR spectra and sensory data obtained using the wine show samples were less significant in general. This may be related to the fact that within most classes in the show, the samples may span vintages, glowing areas and winemaking styles, even though they may be made from only one grape variety. For dry red wines, the best calibrations were obtained with a class of Pinot Noir - a variety that tends to be produced in limited areas in Australia and would represent the least matrix variation. Good correlations were obtained with a tawny port class - these wines are sweet, fortified wines, that are aged for long periods in wooden barrels. During the ageing process Maillard browning compounds are formed and the water is lost through the barrels in preference to ethanol, producing “concentrated” darkly coloured wines with high alcohol content. These calibrations indicated heaviest loadings in the water regions of the spectrum, suggesting that “concentration” of the wines was important, whilst the visible and alcohol regions of the spectrum also featured as important factors. NIR calibrations based on sensory scores will always be difficult to obtain due to variation between individual winetasters. Nevertheless, these results warrant further investigation and may provide valuable Insight into the main parameters affecting wine quality.

  • PDF

수집종 쑥의 청색색소 카마줄렌 함량 변이 (Variation of Chamazulene Contents in Local Collections of Mugwort (Artemisia spp.))

  • 김현주;채영암
    • 한국약용작물학회지
    • /
    • 제9권3호
    • /
    • pp.181-185
    • /
    • 2001
  • 본 연구에서는 청색색소 카마줄렌을 함유한 쑥 종류를 선발하고, 이 카마줄렌 함량이 집단 내에서 개체에 따라 달라지는 지를 알아보고자 조사 분석한 결과를 요약하면 다음과 같다. 1. 국내 수집종 쑥 5종 쑥(Artemisia indica), 물쑥(Artemisia selegensis), 실제비쑥 (Artemisia japonica var. angustissima), 뺑쑥(Artemisia feddel), 황해쑥(Artemisia argyi)의 정유성분을 분석한 결과 카마줄렌을 함유하고 있는 종은 Artemisia indica이었다. 2. 식물체 내에서 영양생장기와 생식생장기 모두 잎이 화기와 줄기보다 카마줄렌을 많이 함유하고 있었다. 영양생장기에는 상위 엽이 중, 하위 엽보다 2.5배 정도 많은 카마줄렌을, 생식생장기에는 상위 줄기가 중, 하위 줄기보다 5-8배 정도 많이 카마줄렌을 함유하였다. 3. 집단 내 50개체의 개체별 카마줄렌 함량의 변이를 조사한 결과 최소 0.015% 에서 최대 0.113%까지의 큰 변이를 보였으며, 전체 개체의 72%인 36 개체가 0.03% 이상의 카마줄렌을 함유한 것으로 나타났다. 4. 모본과 후대(clones)의 카마줄렌 함량을 비교한 결과 차이가 없었다.

  • PDF

A comparison of photosynthesis measurements by O2 evolution, 14C assimilation, and variable chlorophyll fluorescence during light acclimatization of the diatom Coscinodiscus granii

  • Trampe, Erik;Hansen, Per Juel;Kuhl, Michael
    • ALGAE
    • /
    • 제30권2호
    • /
    • pp.103-119
    • /
    • 2015
  • Photosynthetic rates of the large centric diatom Coscinodiscus granii were measured by means of multicolor variable chlorophyll fluorescence imaging, single cell $^{14}C$ assimilation, and optical $O_2$ sensor measurements during light acclimatization of cultures grown at five different irradiances: 50, 150, 235, 332, and $450{\mu}mol$ photons $m^{-2}\;s^{-1}$. Photo-acclimatization was evident from changes of cellular chlorophyll a content, growth rates, and light response curves. Each of the applied methods evaluates different parts and reactions in the photosynthetic apparatus, which makes a direct quantitative comparison of rates difficult, although a different degree of correlation were found between all three methods. However, when used in combination, they provide information about the internal relationship of photosynthetic pathways as well as the variation in photosynthetic capacity between individual cells within a single algal culture.

발전기 회전자 권선의 운전중 층간단락 탐지 (On-Line Detection of Shorted Turn in Generator Rotor Windings)

  • 김희동;이영준;박종정;주영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권3호
    • /
    • pp.192-199
    • /
    • 1999
  • During start up and shut down, the generator is rotating at a low speed and copper dusts cause arcing between the turns in the slot. Shorted turns occurred primarily by the movement of these copper dusts between individual windings in the generator rotor. Detection of shorted turns was performed in five gas turbine generators in two combined cycle power plants. Two types of permanent and temporary flux probes were used in this paper. These flux probes have been used to develop a methodology for detecting shorted turns in an operating generator's rotor. The flux probes sense the rotor winding slot leakage flux and produce a voltage proportional to the rate of change of the flux. This pattern of flux variation is the signature unique to each rotor winding. An appropriate waveform analysis technique canidentify the pole location, the slot number, and the number of shorted turns within each slot. Shorted turns in field winding of gas turbine generator(125.7 MVA) were detected to twelve turns on al total 190 turns.

  • PDF

6MV 광자선에서 측정조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교 (The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams)

  • 김회남
    • 대한방사선치료학회지
    • /
    • 제10권1호
    • /
    • pp.11-22
    • /
    • 1998
  • The absolute absorbed dose can be determined according to the measurement conditions ; measurement material, detector, energy and calibration protocols. The purpose of this study is to compare the absolute absorbed dose due to the differences of measurement condition and calibration protocols for photon beams. Dosimetric measurements were performed with a farmer type PTW and NEL ionization chambers in water, solid water, and polystyrene phantoms using 6MV photon beams from Siemens linear accelerator. Measurements were made along the central axis of $10{\times}10cm$ field size for constant target to surface distance of 100cm for water, solid water and polystyrene phantom. Theoretical absorbed dose intercomparisons between TG21 and IAEA protocol were performed for various measurement combinations on phantom, ion chamber, and electrometer. There were no significant differences of absorbed dose value between TG2l and IAEA protocol. The differences between two protocols are within $1\%\;while\;the\;average\;value\;of\;IAEA\;protocol\;was\;0.5\%$ smaller than TG2l protocol. For the purpose of comparison, all the relative absorbed dose were nomalized to NEL ion chamber with Keithley electrometer and water phantom, The average differences are within $1\%,\;but\;individual\;discrepancies\;are\;in\;the\;range\;of\;-2.5\%\;to\;1.2\%$ depending upon the choice of measurement combination. The largest discrepancy of $-25\%$ was observed when NEL ion chamber with Keithley electrometer is used in solid water phantom. The main cause for this discrepancy is due to the use of same parameters of stopping power, absorption coefficient, etc. as used in water phantom. It should be mentioned that the solid water phantom is not recommended for absolute dose calibration as the alternative of water, since absorbed dose show some dependency on phantom material other than water. In conclusion, the trend of variation was not much dependent on calibration protocol. However, It shows that absorbed dose could be affected by phantom material other than water.

  • PDF

소나무 우량 가계별 기초재질 변이 - 가도관, 마이크로피브릴 경사각, 수지구 분포 및 전건비중을 중심으로 - (Variation of Material Properties of Korean Red Pine of Superior Families - Tracheid Length, Microfibril Angle, Resin Canal and Specific Gravity -)

  • 박병수;박정환;한상억
    • 임산에너지
    • /
    • 제25권2호
    • /
    • pp.9-15
    • /
    • 2006
  • 재질이 우수하고 균일한 목재를 생산하기 위해서는 목부조직의 재질과 구성세포의 변동패턴 및 생장 기구에 대한 이해가 필요하며, 이러한 요소들이 우량종자 생산을 위한 육림기술 지침으로 고려되어야 한다. 본 연구에서는 소나무 우량가계의 차대 검정림에서 가계별 재질특성에 영향하는 인자 중 섬유장, 비중, 마이크로피브릴 경사각, 수지구 분포비율 등을 조사하여 다음과 같은 결과를 얻었다. 방사방향 가도관 길이 변이는 강원26, 30, 90, 56호 및 충남 4호는 $11{\sim}13$년 사이에서 가도관 길이 신장률이 1% 이하로 안정되었으며, 13년을 기점으로 매우 빠르게 성숙재로 전환 되었다. 전건비중은 $0.35{\sim}049$의 범위에 있었으며, 가계별로는 강원26호가 0.35로 가장 작고, 강원57호가 0.49로 가장 컸으며, 각 가계 간 차이가 큰 것으로 나타났다. $mm^2$당 수평수지구는 강원79호가 1.1개로 가장 적고, 강원83호는 1.7개로 많았으며, 가계별 차이가 인정되었다. 성숙재의 평균 마이크로피브릴 경사각은 $9.0{\sim}28.6^{\circ}$의 범위 내에 속하며 강원74호가 $9.0^{\circ}$로 가장 작고, 충남4호가 $28.6^{\circ}$로 가장 크며 가계 간 차이가 큰 것으로 나타났다.

  • PDF