• 제목/요약/키워드: wire-plate

검색결과 287건 처리시간 0.026초

Wire Mesh 적용을 통한 PEMFC 성능 향상에 관한 연구 (A Study on Performance Improvement of PEMFC Using Wire Mesh Cell Structure)

  • 진상문;백석민;허성일;양유창;김세훈
    • 한국수소및신에너지학회논문집
    • /
    • 제21권4호
    • /
    • pp.295-300
    • /
    • 2010
  • Metal bipolar plate applied to Polymer Electrolyte Membrane Fuel Cell is getting most attractive due to their good feasibility of mass production and low cost. But it is one of the immediate causes of performance decline because it is difficult to reduce channel pitch of metal bipolar plate. In this study, mesh was inserted in between bipolar plate and GDL to obtain uniform contact pressure without reducing channel pitch. The section measuring and performance test were carried out to confirm the mesh structure distributes contact pressure equally in reacting area. The performance of 3 type mesh structures developed in this study were higher than the normal cell at all over the current range. Especially, it showed that the mesh cell performance was increased and pressure drop was decreased with diminishing mesh gap size. The Mesh structure was more sensitive to humidification and contact pressure change than the normal cell.

예인수조 LDV를 이용한 평판 경계층과 와이어 타입 난류촉진장치의 상호작용에 관한 연구 (Towed Underwater LDV Measurement of the Interaction of a Wire-Type Stimulator and the Boundary Layer on a Flat Plate)

  • 박종열;서정화;이신형
    • 대한조선학회논문집
    • /
    • 제58권4호
    • /
    • pp.243-252
    • /
    • 2021
  • The present study aims to investigate the interaction of a wire-type turbulence stimulator and the laminar boundary layer on a flat plate by flow field measurement. For the towing tank tests, a one-dimensional Laser Doppler Velocimetry (LDV) attached on a two-axis traverse was used to measure the streamwise velocity component of the boundary layer flow in zero pressure gradient, disturbed by a turbulence stimulator. The wire diameter was 0.5 and 1.0 mm according to the recommended procedures and guidelines suggested by the International Towing Tank Conference. Turbulence development by the stimulator was identified by the skin friction coefficient, mean and Root Mean Square (RMS) of the streamwise velocity. The laminar boundary layer with the absence of the wire-type stimulator was similar to the Blasius solution and previous experimental results. By the stimulator, the mean and RMS of the streamwise velocity were increased near the wall, showing typical features of the fully developed turbulent boundary layer. The critical Reynolds number was reduced from 2.7×105 to 1.0×105 by the disturbances caused by the wire. As the wire diameter and the roughness Reynolds number (Rek) increased, the disturbances by the stimulator increased RMS of the streamwise velocity than turbulent boundary layer.

2단 평행판 전기집진기의 서브마이크론입자 집진성능 개선 연구 (Study on improvement of submicron particle collection performance in 2-stage parallel-plate electrostatic precipitators)

  • 유경훈;오명도;이준식
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.323-332
    • /
    • 1997
  • It was reported by some researchers that two-stage parallel-plate ESPs, commonly called electronic air cleaners, show decreasing behavior of collection efficiency as particle size decreases below about $0.03{\mu}m$. This phenomenon is attributed to partial particle charging characteristics, where some of incoming particles are not charged in the charging cell of 2-stage parallel-plate ESP. One way to improve the decreasing collection efficieny in that particle size range is to enforce particle charging quantity in the charging cell. In the present study, in order to do this a 2-wire series-type charging cell modified from a 1-wire normal-type one was suggested and investigated theoretically and experimentally concerning improvement of the collection efficiency. It was confirmed from the experimental and theoretical works that the collection efficiency was apparently improved.

  • PDF

복수 트리핑 와이어를 사용한 평판에서의 열전달 촉진에 관한 연구 (A Study on Heat Transfer Enhancement from Flat Plate Using Multiple Tripping Wires)

  • 유성연;조웅선;안종규
    • 설비공학논문집
    • /
    • 제24권12호
    • /
    • pp.837-845
    • /
    • 2012
  • The purpose of this research is to investigate the heat transfer enhancement by the multiple tripping wires installed on a flat plate. Naphthalene sublimation technique is used to measure the local mass transfer coefficients, and then heat transfer coefficients are calculated using heat/mass transfer analogy. Experiments are performed for the developed and developing flow conditions. Local and average heat transfer coefficients from the flat plate with three tripping wires are compared with those of no and one tripping wire. Remarkable heat transfer enhancements are found resulting from the boundary layer separation by the tripping wires, especially in the laminar boundary layer.

아몰퍼스 와이어의 ECT probe 적용에 대한 검토 (Application of Amorphous wire to ECT(Eddy Current Testing) Probe)

  • 김영학;신광호;사공건
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.47-51
    • /
    • 2002
  • ECT(eddy currentign testing) is very effective technique to detect a flaw within a conductor. Co-based amorphous wire was used as a sensor head. The wire has almost 0 magneto-striction and high permeability. An uniform magnetic field was applied to 1mm thick copper plate and $25{\mu}m$ thick aluminum sheet conductor using spiral typed coil The size of the coil has $40mm{\times}40mm$ outer width and $8mm{\times}8mm$ inner width. The copper plate and aluminum sheet has 0.5mm and 0.1mm wide gap, respectively. The frequency range of applied field was 100kHz-600kHz. The induced voltage difference of 2.5mV was obtained in the maximum voltage and minimum one measured across the gap of the 1mm thick conductor. In the case of aluminum sheet, 0.4mV was obtained. From this results, the effectiveness of Co-based amorphous wire was confirmed in the ECT technique.

  • PDF

쇄골 원위부 골절에 대한 재건 금속판과 강선 고정술을 이용한 치료 (Treatment of Distal Clavicular Fracture by Reconstruction Plate and Wire Fixation)

  • 서무삼;김상효;박형택
    • 대한정형외과스포츠의학회지
    • /
    • 제5권1호
    • /
    • pp.58-62
    • /
    • 2006
  • 목적: 쇄골 원위부 골절의 치료에 있어 재건 금속판과 강선 고정술을 이용한 치료 결과를 알아보고자 하였다. 대상 및 방법: 2001 년 3월부터 2003년 7월까지 본원에서 쇄골 외측단의 골절에 대하여 재건금속판과 강선고정술을 이용하여 수술한 환자 중 1년 이상 추시관찰이 가능하였던 9예를 대상으로 하였다. 수술 방법은 재건 금속판을 쇄골 상단에 지지대로 사용하였고, 분쇄가 있는 골절 부분을 나사를 대신하여 $2{\sim}3$개의 강선 고정으로 고정하였으며 고정이 약한 경우 견봉쇄골 관절을 포함하였다. 수술 후 기능회 복의 정도는 Rowe의 견관절 평가 방법을 이용하였다. 결과: 추시 관찰상 평균 9주에 골유합의 소견을 얻었다. 기능적 평가로 Rowe의 견관절 평가방법상 우수가 7예, 양호가 2이었다. 견관절의 운동 제한이나 견봉 쇄골 관절의 관절염 소견은 보이지 않았고, 합병증으로는 금속판에 의한 피부자극이 1예 있었다. 결론: 쇄골 원위부 골절에서 재건 금속판과 강선 고정술을 이용한 부분적인 고정법은 분쇄가 심하고, 원위골절편이 작은 경우 특히 유용하였다. 이 방법은 간단하고, 관절 운동 향상, 조기 기능 회복과 합병증이 적다는 측면에서 유용할 것으로 사료된다.

  • PDF

와이어로프와 T 강판으로 비부착 보강된 철근콘크리트 기둥의 중심 축하중 거동 (Axial Behavior of Reinforced Concrete Columns Externally Strengthened with Unbonded Wire Rope and T-Shaped Steel Plate)

  • 양근혁;심재일;변항용
    • 콘크리트학회논문집
    • /
    • 제20권2호
    • /
    • pp.221-229
    • /
    • 2008
  • 와이어로프와 T형 강판을 이용한 개선된 비부착형 기둥보강 공법이 개발되었다. 제시된 절차에 따라 보강된 기둥 8개와 동일한 조건의 무보강 기둥 1개가 중심 축하중 하에서 실험되었다. 주요 변수는 와이어로프 체적비와 T 강판의 플랜지 폭 및 배치 형상이다. 실험된 기둥의 축하중 내력과 연성비는 각각 ACI 318-05의 예측값과 Chung et al.에 의해 수행된 일반 띠기둥의 실험 결과와 비교되었다. 게다가 와이어로프와 T 강판으로 구속된 콘크리트의 응력-변형률 관계를 평가하기 위한 모델이 제시되었다. 실험 결과로부터 기둥의 축하중 내력과 연성은 와이어로프의 체적비와 T 강판의 플랜지 폭의 증가와 함께 증가하였다. 특히 동일 횡보강근 지수에서 와이어로프 체적비가 0.0039 이상일 때 보강된 기둥의 연성비는 띠철근 기둥에 비해 현저히 높았다. 개발된 보강기술에 의해 구속된 콘크리트의 응력-변형률 관계 모델이 제시되었다. 예측된 응력-변형률 관계는 실험 결과와 잘 일치하였다.

고온용 RFID 태그 패키징 및 접합 방법 (Bonding Method and Packaging of High Temperature RFID Tag)

  • 최은정;유대원;변종헌;주대근;성봉근;조병록
    • 한국통신학회논문지
    • /
    • 제35권1B호
    • /
    • pp.62-67
    • /
    • 2010
  • 본 연구는 다양한 산업 환경에 적용되는 RFID 태그 개발에 있어 RFID 태그 패키징 개발과 RFID 태그 플립칩(flip chip) 접합 방법이 산업 환경 맞춤형 RFID 태그 개발에 미치는 영향에 대해 분석하였다. RFID 태그 플립칩(flip chip) 접합은 와이어 접합(wire bonding), 초음파 접합(ultrasonic bonding), 열융착 접합(heat plate bonding), 레이저 접합(laser bonding)으로 구분되어 있으며, 이런 접합 방법은 다양한 RFID 태그 개발의 적용 환경에 따라 적합한 접합 방법이 있음을 본 연구를 통해서 알 수 있었다. 극고온, 극저온, 다습, 고내구성 등 다양한 산업 환경 중 극고온 환경에서의 RFID 태그 개발은 빛 에너지를 흡수하여 열 에너지로 전환하는 레이저 접합 방법과 직접적인 열 전달 방식인 열융착 접합 방법은 접속 재료인 ACF의 손상으로 인해 부적합하고, 와이어를 이용하여 직접 범프와 패턴을 연결하는 와이어 접합 방법이 적합함을 알 수 있었다.

평판 경계층과 후류와의 상호관계에 관한 연구; 평균속도장 (An Experimental Study of Mutual Relation between Wake and Boundary Layer of a Flat Plate; Mean Velocity Field)

  • 김동하;장조원
    • 한국항공우주학회지
    • /
    • 제32권10호
    • /
    • pp.1-11
    • /
    • 2004
  • 평판의 근접 후류에서 상류 경계층의 영향을 조사하기 위한 실험적 연구가 수행되었다. 트리핑 와이어(tripping wire)의 여러 부착 위치가 경계층의 유동조건을 유발시키기 위하여 선택되었다. 평판 앞전에서부터 0.98C 위치에서의 층류, 천이, 난류경계층이 대칭, 비대칭 후류의 발달과정을 조사하기 위하여 부과되었다. X형태의 열선 프로브(55P61)를 이용한 측정은 근접 후류의 8위치에서 수행되었고, 측정된 평균속도분포는 기존의 후류 상사변수로 무차원화 되어 제시되었다. 대칭 후류는 후류의 중앙부분에서 기존의 상사곡선과 일치하지만, 비대칭 후류는 측정된 범위에서 기존의 상사 곡선과 일치하지 않았다.

무용접 압접 데크플레이트의 구조성능에 관한 실험 - 시공단계에서의 구조안전성 평가 - (Test on the Structural Performance of the TOX Deck plate - Evaluation of Structural Safety during Construction Stage -)

  • 오상훈;김영주;윤명호
    • 한국강구조학회 논문집
    • /
    • 제20권6호
    • /
    • pp.701-709
    • /
    • 2008
  • 철골 데크플레이트 시스템은 시공의 편의성과 공기단축 때문에 건설현장에서 널리 사용되고 있으며, 그중에서도 특히 철선과 데크플레이트가 혼합된 시스템 (트러스 데크플레이트 시스템)이 우수한 구조적 성능과 및 경제성에 의해서 최근에 매우 각광을 받고 있다. 그러나 트러스 데크플레이트 시스템은 많은 장점에도 불구하고 래티스 철선과 데크플레이트에 용접을 하므로 철판이 용접부위에서 녹이 발생하게 되고, 용접부의 균열과 이에 따른 누수가 발생하는 등의 결점이 있다. 이러한 문제를 해결하기 위해서 용접을 하지 않고 녹발생이 없는 새로운 데크플레이트 시스템, 즉, TOX 데크플레이트 시스템의 적용성을 검토하였다. 본 연구에서는 15개의 실험을 통해 시공단계에서의 데크플레이트 시스템의 구조적 안전성을 평가하고자 한다. 실험변수는 슬래브의 두께, 경간의 길이, 상부, 하부 및 래티스 철선의 직경 그리고 아연도금강판 재료 등이다. 실험결과 제안된 TOX 데크플레이트 시스템은 처짐과 내력에 있어서 구조적으로 충분히 안전성이 있는 것으로 보인다.