• Title/Summary/Keyword: wire tension

Search Result 247, Processing Time 0.022 seconds

SmBCO 고온 초전도 선재의 안정화재 특성 (A study on the properties of SmBCO coated conductors with stabilizer tape)

  • 김태형;오상수;김호섭;고락길;송규정;하홍수;이남진;박경채;하동우
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권3호
    • /
    • pp.9-12
    • /
    • 2007
  • In this study. we searched for the mechanical and electrical properties of laminated coated conductors with stabilizer tape. Stabilizer tape plays a role for mechanical and electrical stability and environmental protection. Cu material stabilizer was laminated to Ag capping layer on SmBCO conductor layer. This architecture allows the wire to meet operational requirements including the stressless at cryogenic temperature and winding tension as well as mechanical bending requirements including thermal and electrical stability under fault current conditions. First, we have experimentally studied mechanical bonding properties of the laminated Cu stabilizers on SmBCO coated conductors. We have laminated SmBCO coated conductors by continuous dipping soldering process, Second, we have investigated electrical properties of the SmBCO coated conductors with stabilizer lamination. We evaluated bonding properties, peeling strength and critical current for laminated SmBCO coated conductors with Cu stabilizers.

요부 안정화를 위한 복대형 입는 로봇 개발 (Development of Brace-type Wearable Robot for Lumbar Stabilization)

  • 김주완;심재훈;김기원;정선근;박재흥
    • 로봇학회논문지
    • /
    • 제18권2호
    • /
    • pp.189-196
    • /
    • 2023
  • An abdominal brace is a recommended treatment for patients with lumbar spinal disorders. However, due to the nature of the static brace, it uniformly compresses the lumbar region, which can weaken the lumbar muscles or create a psychological dependence that worsens the condition of the spine when worn for an extended period of time. Due to these issues, doctors limit the wearing time when prescribing it to patients. In this paper, we propose a device that can dynamically provide abdominal pressure and support according to the lumbar motion. The proposed device is a wearable robot in the form of a brace, with actuators and a driving unit mounted on the brace. To enhance wearability and reduce the weight of the device, worm gears actuator and a multi-pulley mechanism were adopted. Based on the spinal motion of the wearer measured by the Inertia measurement unit sensors, the drives wire by driving pulley, which provide tension to the multi-pulley mechanism on both sides, dynamically tightening or loosening the device. Finally, the device can dynamically provide abdominal pressure and support. We describe the hardware and system configuration of the device and demonstrate its potential through basic control experiments.

목재(木材)파아티클과 철선(鐵線) 복합체(複合體)가 보오드의 물리적(物理的) 및 기계적(機械的) 성질(性質)에 미치는 영향(影響) (Effects of Wood Particles and Steel Wire Compositions on Physical and Mechanical Properties of the Boards)

  • 박헌;이필우
    • Journal of the Korean Wood Science and Technology
    • /
    • 제14권1호
    • /
    • pp.3-44
    • /
    • 1986
  • 목재(木材)파아티클과 성질(性質)이 전혀 다른 철선(鐵線)을 물리적(物理的)으로 결합(結合)시킴으로써 목재(木材)와 철재(鐵材)의 재료적(材料的) 특성(特性)을 서로 보완(補完)하여 목재(木材)파아티클과 철선(鐵線)의 새로운 복합체(複合體)인 목질(木質)-철선(鐵線)보오드를 제조(製造)하고 그 특성(特性)을 구명(究明)하여 기초자료(基礎資料)를 얻고자 하였다. 메란티 합판제조폐재(合板製造廢材)을 이용(利用)한 팔만칩을 12mesh를 통과하고 20mesh체에 남는 큰 파아티클과 20mesh을 통과하고 60mesh체에 남는 작은 파아티클로 구분하여 요소수지를 분무한 다음, 굵기 1mm인 철선(鐵線)을 나비방향과 길이방향으로 1, 2 및 3층(層)으로 배열하여 성형(成型)하고 시험용(試驗用) 복합(複合) 파아티클 보오드를 제조하였다. 1층(層) 철선구성(鐵線構成)보오드의 경우에는 철선간(鐵線間)의 배치간격(配置間隔)을 나비방향과 길이방향(方向)으로 각기 0.5cm, 1cm, 1.5cm, 2cm 및 2.5cm 등(等) 5가지로 하여 24가지의 철선구성방법(鐵線構成方法)으로 하였으며, 2층(層) 철선구성(鐵線構成 )보오드는 철선구성간격(鐵線構成間隔)을 1cm로 하였고 철선구성방법(鐵線構成方法)을 3가지로 하였으며, 3층(層) 철선구성(鐵線構成)보오드는 철선구성간격(鐵線構成間隔)을 1cm로 하고 철선구성방법(鐵線構成方法)을 11가지로 하여 제조(製造)한 보오드는 대조(對照)보오드를 포함(包含)하여 312개였다. 보오드를 성형(成型)한 열압온도(熱壓溫度) 160$^{\circ}C$, 악력(壓力) 35kgf/$cm^2$, 열압시간(熱壓時間) 9분(分)으로 하여 보오드를 제조(製造)하고 이 목질(木質) 철선복합(鐵線複合)보도드의 물리적(物理的) 및 기계적(機械的) 성질(性質)을 측정(測定)분석(分析)한 바 다음과 같은 결과(結果)를 얻었다. 1. 큰 파아티클과 작은 파아티클로 제조(製造)한 보오드에서 철선구성층수(鐵線構成層數) 및 구성철선(構成鐵線)의 수(數)가 많은 보오드일수록 그 비중(比重)은 컸었다. 2. 큰 파아티클로 제조(製造)한 보오드는 철선구성(鐵線構成)으로 인하여 두께팽창율(膨脹率)의 감소(減少)가 뚜렷하였으며 특히 철선구성층수(鐵線構成層數)가 많을수록 이 팽창율(膨脹率)은 더 개선되었다. 3. 큰 파아티클 및 작은 파아티클로 제조(製造)한 보오드 공(共)히 철선구성층수(鐵線構成層數)가 증가(增加)함에 따라 철선(鐵線)의 강도적(强度的) 특성(特性)이 파아티클 휨강도(强度) 성질(性質)을 보강(補强)하여 파괴계수(破壞係數), 탄성계수(彈性係數), 휨 극한하중(極限荷重) 일량(量) 등(等)이 개선(改善)되었으며, 2층(層) 및 3층(層) 철선구성(鐵線構成)보오드의 경우 보오드의 하층(下層)의 철선구성방향(鐵線構成方向)이 보오드의 길이방향(方向)과 일치(一致)하는 보오드가 특(特)히 큰 휨강도(强度) 향상(向上)을 보여 인장라미네이션을 얻었다. 4. 1층(層) 철선구성(鐵線構成)보오드는 철선구성간격(鐵線構成間隔)에 따른 개구면적(開口面積)과 파아티클의 크기에 따라 파괴계수(破壞係數), 탄성계수(彈性係數), 휨 극한하중(極限荷重) 일량(量) 등(等)이 다르게 나타났으나, 큰 파아티클로 제조(製造)한 보오드의 파괴계수(破壞係數)는 개구면적(開口面積)이 1.5~3$cm^2$이고, 나비 방향(方向)의 철선구성간격(鐵線構成間隔)이 1~2cm이면서 길이방향(方向)의 철선구성간격(鐵線構成間隔)이 1.5~2.5cm인 보오드가 높은 값을 나타냈고 작은 파아티클로 제조(製造)한 보오드의 파괴계수(破壞係數)는 개구면적(開口面積)이 0.5~1.5$cm^2$ 및 3.75~6.25$cm^2$이고 나비 방향(方向)의 철선간격(鐵線間隔)이 0.5cm이거나 2.5cm인 보오드가 높은 값을 나타냈다. 5. 큰 파아티클로 제조(製造)한 1층(層) 철선구성(鐵線構成)보오드의 탄성계수(彈性係數)는 개구면적(開口面積)이 1.5~3$cm^2$이고 나비방향(方向) 및 길이방향(方向)의 철선구성간격(鐵線構成間隔)이 1~2.5cm에서 큰 값을 나타냈으며, 한편 작은 파아티클로 제조(製造)한 보오드의 탄성계수(彈性係數)는 개구면적(開口面積)이 0.75~1.25$cm^2$ 민 3~6.25$cm^2$이고, 나비방향(方向)의 철선구성간격(鐵線構成間隔)이 0.5 또는 2.5cm에서 큰 값을 나타내었다. 6. 큰 파아티클로 제조(製造)한 1층(層) 철선구성(鐵線構成)보오드의 휨 극한하중(極限荷重) 일량(量)은 개구면적(開口面積)이 1~3$cm^2$인 보오드가 큰 값을 보였고, 작은 파아티클로 제조(製造)한 보오드의 경우의 그것은 철선(鐵線)의 개구면적(開口面積)이 좁은 것이 크게 나타났다. 7. 박리저항(剝離抵抗) 및 나사못보지력(保持力)은 큰 파아티클로 제조(製造)한 3층(層) 및 2층(層) 철선구성(鐵線構成)보오드에서 대부분(大部分) 대조(對照)보오드보다 큰 값을 보였으나 작은 파아티클로 제조(製造)한 보오드에서는 뚜렷한 경향이 없었다. 큰 파아티클로 제조(製造)한 1층(層) 철선구성(鐵線構成)보오드의 박리저항(剝離抵抗) 및 나사못보지력(保持力)은 전체적으로 비슷한 수준(水準)을 보였고 작은 파아티클로 제조한 보오드에서는 개구면적(開口面積)이 증가(增加)함에 따라 박리저항(剝離抵抗)은 증가(增加)하고 나사못보지력(保持力)은 감소(減少)하는 현상(現象)을 보였다.

  • PDF

물-공기 수평 성층류 유동조건에서 액적이탈 현상에 대한 실험연구 (Experimental Investigation on the Droplet Entrainment in the Air-Water Horizontal Stratified Flow)

  • 배병건;윤병조;김경두;배병언
    • 에너지공학
    • /
    • 제24권1호
    • /
    • pp.114-122
    • /
    • 2015
  • 수평 성층류 2상 유동에서 기체의 속도가 액체의 속도보다 상대적으로 큰 고유속 유동조건에서는 불규칙한 파형들이 생성되고 이때 상 경계면에서는 액적이탈이 발생한다. 한국원자력연구원(KAERI)에서는 이러한 상 경계면에서의 액적이탈 현상을 기구학적으로 예측하기 위하여 전단력, 표면장력, 그리고 중력 항으로 구성되는 새로운 액적이탈 모델을 제시하였다. 그러나 이 액적이탈 모델 내부에는 아직 결정되지 않은 모델 계수가 존재한다. 모델 계수를 결정하기 위해서는 두 상 사이의 계면파 특성과 관련되는 물리변수들에 대한 실험데이터의 확보가 필요하다. 주요 물리변수들에는 파의 기울기, 파의 빗변길이, 파의 속도, 파의 주파수, 그리고 파장이 있다. 본 연구에서는 계면파 특성과 관련된 주요 물리변수들을 측정하기 위하여 폭 40 mm, 높이 50 mm, 길이 4.2 m의 수평사각유로에서 가시화실험을 수행하였다. 실험은 1기압의 물-공기 성층류 유동에서 액적이탈이 발생되는 조건에서 수행되었다. 본 실험에서 계면 형상을 2차원적으로 가시화하고 계면파에서 국소적인 물속도 분포를 측정하기 위하여 유로 측면에서 PIV기법을 적용하였다. 추가적으로, 가시화실험을 통해 획득한 계면 이미지로부터 측정된 계면 높이를 검증하기 위하여 평행 와이어 전도도 센서를 개발하였다. 가시화방법과 센서를 통해 측정된 수위를 비교한 결과, 두 가지 방법론에 의해 측정된 수위결과가 잘 일치함을 확인하였다. 최종적으로 개발된 측정기법을 적용하여 액적이탈 조건에서 계면파 특성과 관련된 주요 물리변수들을 측정하였다.

Treatment of Surgical Site Infection and Delayed Union in Fetlock Arthrodesis of a Mare

  • Lee, Sang-Kyu;Kim, Jinyoung;Seo, Jong-pil;Lee, Inhyung;Kang, Byung-Jae
    • 한국임상수의학회지
    • /
    • 제37권3호
    • /
    • pp.157-162
    • /
    • 2020
  • A 6-year-old Thoroughbred mare presented to the Korea Racing Authority Equine Hospital with dropping of the left front fetlock due to an injury sustained while racing. Radiographic examination revealed a comminuted fracture of both proximal sesamoid bones of the affected fetlock. Arthrodesis of the fetlock joint using a broad dynamic compression plate with a tension band wire was performed as a salvage procedure for the future use as a broodmare. After surgery, however, a delayed union of the bones and surgical site infection was present for a prolonged period. Staphylococcus aureus was persistently identified from the surgical site, and antimicrobial therapies were based on antibiotic sensitivity tests, including regional perfusions. The removal and replacement of surgical implants associated with seropurulent discharge was based on coordinating the development of fetlock ankylosis and infection control over 13 months. Firstly, seven screws associated with surgical drainage were replaced and bone morphogenetic protein-2 (BMP-2) and local antibiotics were placed into the surgical site to accelerate bone fusion at postoperative month 7. Further six screws, along with drainage, were removed at postoperative month 10. The plate and screws were removed from the limb due to the progression of bone fusion at postoperative month 13; BMP-2 and local antibiotics were also used. Delayed healing of arthrodesis due to surgical site infection and implant instability were treated by implant removals and antibiotic therapies, and the horse eventually showed improved weight-bearing ability of the affected limb.

병렬 연결된 해상 크레인을 이용한 대형 중량물 인양 작업의 동적 거동 계산 시뮬레이션 (Dynamic Response Simulation of a Heavy Cargo Suspended by Parallel Connected Floating Cranes)

  • 차주환;구남국;노명일;이규열
    • 대한기계학회논문집A
    • /
    • 제36권6호
    • /
    • pp.681-689
    • /
    • 2012
  • 본 연구에서는 병렬 연결된 해상 크레인을 이용하여 5,000ton 이상의 기가 블록급 대형 중량물을 인양할 때 해상 크레인과 대형 중량물 사이에 연결된 와이어 로프에 작용하는 장력을 계산하기 위해 다물체계 동역학 시뮬레이션을 수행하였다. 이를 위해, 해상 크레인, 바지선, 대형 중량물은 각각 6 자유도 운동을 하고, 이들 사이에는 서로간의 구속에 의한 연성을 가지도록 모델링 하였다. 또한 해상 크레인 및 바지선에 작용하는 외력으로 유체 정역학 힘과 유체 동역학 힘을 고려하였고, 각각의 물체에 독립적으로 작용한다고 가정하였다. 본 시뮬레이션 결과, 향후 해상크레인을 병렬 연결하여 대형 중량물을 인양하는 공법의 안정성을 확인하고 공학적인 지침을 마련할 수 있는 근간이 될 수 있으리라 예상한다.

고령 환자의 절단된 수지의 재접합술 (Replantation of Amputated Digits in Elderly Patients)

  • 정순일;김진수;이동철;기세휘;노시영;양재원
    • Archives of Plastic Surgery
    • /
    • 제37권5호
    • /
    • pp.644-649
    • /
    • 2010
  • Purpose: As the mean life expectancy of people has been prolonged, and the elderly people who participate in the production activities has been increasing, it is expected that the demand on the replantation of amputated digits in elderly patients would increase. But, there are few studies about the replantation of amputated digits in elderly patients. Therefore, we report treatment outcomes of replantation of amputated digits in elderly patients. Methods: From 1998 to 2008, the replantation was performed in 51 completely amputated digits of 33 patients aged 60 years or older. We performed the replantation in the usual manner. Under the brachial plexus block, the surgical procedures carried out in the following sequence: internal fixation using Kirschner wire, tenorrhaphy, arteriorrhaphy, neurorrhaphy and venorrhaphy. If the arterial ends could not be approximated without tension, a vein graft was performed. Results: Of a total of 51 digits, 46 digits (90%) survived. 13 patients (40%) had underlying medical problem preoperatively. But, in all the patients, there were no postoperative medical complications. As the postoperative surgical complications, excluding five cases of the total necrosis of digit, there were three cases of venous congestion, two cases of arterial insufficiency, seven cases of infection and 16 cases of partial necrosis. Conclusion: Age alone does not affect the survival of replanted digits. Type of injury is the most important factor that affects the survival of replanted digits.

광센서와 카메라를 활용한 비접촉식 낙석감지 시스템 개발 및 적용 (Development and Application of Non-Contact Rock Fall Detection System utilizing Photo Sensor and Camera)

  • 정용복;송원경;김복철;김명진
    • 터널과지하공간
    • /
    • 제20권3호
    • /
    • pp.207-216
    • /
    • 2010
  • 국내에서 현재까지 개발되어 적용된 낙석감지 시스템은 주로 낙석방지망에 와이어나 광섬유, 또는 경사계를 설치하여 와이어의 장력을 측정하거나 낙석 발생에 의해 와이어 단락이나 낙석방지망의 변형 또는 기울어지는 것을 감지하여 낙석을 확인하는 시스템들이다. 이러한 방법들은 낙석방지망이 먼저 설치되어 있어야 하며 낙석이 발생하면 일반적으로 관련 센서와 와이어 등에 대하여 재정비를 해야 다시 원래의 기능을 수행할 수 있게 된다. 이러한 단점을 해결하기 위하여 본 연구에서는 장력이나 변위 측정방식이 아니라 광센서와 카메라가 설치된 구역에서 낙석 통과 여부를 비접촉 방식으로 실시간 감지가 가능하도록 하는 방법을 제시하고 이를 구현하였다. 개발된 시스템을 실내실험 및 현장 적용을 한 결과 낙석 관련 정보를 효과적으로 수집하고 분석할 수 있었다. 또한 낙석 감지 전후 획득한 2장의 사진에 대하여 lighten 또는 difference 연산을 적용할 경우 낙석의 크기와 이동 방향에 대한 개략적 평가가 가능하였다.

Flexural tests on two-span unbonded post-tensioned lightweight concrete beams

  • Yang, Keun-Hyeok;Lee, Kyung-Ho;Yoon, Hyun-Sub
    • Structural Engineering and Mechanics
    • /
    • 제72권5호
    • /
    • pp.631-642
    • /
    • 2019
  • The objective of the present study is to examine the flexural behavior of two-span post-tensioned lightweight aggregate concrete (LWAC) beams using unbonded tendons and the reliability of the design provisions of ACI 318-14 for such beams. The parameters investigated were the effective prestress and loading type, including the symmetrical top one-point, two third-point, and analogous uniform loading systems. The unbonded prestressing three-wire strands were arranged with a harped profile of variable eccentricity. The total length of the beam, measured between both strand anchorages, was 11000 mm. The test results were compared with those compiled from simply supported LWAC one-way members, wherever possible. The ultimate load capacity of the present beam specimens was evaluated by the collapse mechanism of the plasticity theorem and the nominal section moment strength calculated following the provision of the ACI 318-14. The test results showed that the two-span post-tensioned LWAC beams had lower stress increase (Δfps) in the unbonded tendons than the simply supported LWAC beams with a similar reinforcement index. The effect of the loading type on Δfps and displacement ductility was less significant for two-span beams than for the comparable simply supported beams. The design equations for Δfps and Δfps proposed by ACI 318-14 and Harajli are conservative for the present two-span post-tensioned LWAC beams, although the safety decreases for the two-span beam, compared to the ratios between experiments and predictions obtained from simply supported beams.

Long-term monitoring of ground anchor tensile forces by FBG sensors embedded tendon

  • Sung, Hyun-Jong;Do, Tan Manh;Kim, Jae-Min;Kim, Young-Sang
    • Smart Structures and Systems
    • /
    • 제19권3호
    • /
    • pp.269-277
    • /
    • 2017
  • Recently, there has been significant interest in structural health monitoring for civil engineering applications. In this research, a specially designed tendon, proposed by embedding FBG sensors into the center king cable of a 7-wire strand tendon, was applied for long-term health monitoring of tensile forces on a ground anchor. To make temperature independent sensors, the effective temperature compensation of FBG sensors must be considered. The temperature sensitivity coefficient ${\beta}^{\prime}$ of the FBG sensors embedded tendon was successfully determined to be $2.0{\times}10^{-5}^{\circ}C^{-1}$ through calibrated tests in both a model rock body and a laboratory heat chamber. Furthermore, the obtained result for ${\beta}^{\prime}$ was formally verified through the ground temperature measurement test, expectedly. As a result, the ground temperature measured by a thermometer showed good agreement compared to that measured by the proposed FBG sensor, which was calibrated considering to the temperature sensitivity coefficient ${\beta}^{\prime}$. Finally, four prototype ground anchors including two tension ground anchors and two compression ground anchors made by replacing a tendon with the proposed smart tendon were installed into an actual slope at the Yeosu site. Tensile forces, after temperature compensation was taken into account using the verified temperature sensitivity coefficient ${\beta}^{\prime}$ and ground temperature obtained from the Korean Meteorological Administration (KMA) have been monitored for over one year, and the results were very consistent to those measured from the load cell, interestingly.