• 제목/요약/키워드: wire model

검색결과 655건 처리시간 0.024초

압축공기 발사기에 단선 와이어 유도방식을 적용한 1/60축척 터널주행 열차모형 시험기 개발에 대한 연구 (Development of 1/60th Scale Moving Model Rig Using the Compressed Air Launcher and One-Wire Guidance System of Train Model)

  • 김동현;오일근
    • 대한기계학회논문집B
    • /
    • 제25권5호
    • /
    • pp.634-644
    • /
    • 2001
  • The test facility of a 1/60-scale model for train-tunnel systems has been recently developed to investigate the effects of tunnel portal shapes, hood shapes and air-shafts for reducing the micro-pressure waves radiating towards the surroundings from the tunnel exit. The present test rig has been advanced from a 1/70-scale facility at NLR in Netherlands. The NLR test rig has the two-wise guidance system that needs two ears attached on the external surface of a model train nose. Therefore, their train models have irregular nose shapes. The main characteristics of the present facility are that the train model is guided by only one wire from the compressed air launcher to the absorber parts of test facility and the wire guidance hole is located at the axial center of a train model. In the present test rig, after a train model is launched, the air jet from the launcher does not enter the tunnel model. Experimental results were compared with numerical predictions to prove the performance of the test facility.

고전류밀도 초전도선의 안전성 (Stability of a high current density superconducting wire)

  • 김대선;류경우;최병주
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.61-64
    • /
    • 1999
  • Dry winding is generally adopted in superconducting coils of an UPS system. In these kinds of coils a quench is often initiated by a disturbance such as wire motion that generates a highly localized normal zone in a superconducting wire. To fabricate the stable coils, stability of the superconducting wire should be touched. In this paper, a model for a transient stability analysis of the wire is suggested. The influence of a local disturbance, cooling, an external field and a stabilizer to superconductor ratio on the wire stability is investigated and discussed.

  • PDF

코어드 와이어 피딩에 의한 Cu 용탕에의 합금 첨가 시 효율 평가 (Evaluation on the Efficiency of Cored Wire Feeding in Addition of Alloying Elements into Cu Melt)

  • 강복현;김기영
    • 한국주조공학회지
    • /
    • 제33권6호
    • /
    • pp.248-253
    • /
    • 2013
  • To add alloying elements into a pure copper melt, the wire-feeding efficiency of cored (alloy containing) wire was evaluated using a commercial, computational fluid-dynamics program. The model design was based on an industrial-scale production line. The variables calculated included wire feed rate, melt temperature, wire diameter, melt flow rate and wire temperature. Efficiency was evaluated after a series of calculations based on the penetration depth of the alloy-wire into the molten copper bath. Of the five variables investigated, the wire feed rate and wire diameter were the most influential factors affecting the feeding efficiency of the cored-wire.

22.9kV 배전선로 중성선 설치 구조에 따른 유도뢰 차폐효과 분석 (Analysis on the Induced Lightning Shielding Effect According to the Neutral Wire Installation Structure of a 22.9kV Distribution Line)

  • 김점식;김도영;박용범
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.191-196
    • /
    • 2010
  • The electricity distribution system in Korea is adopting a multi-grounding system. Protection of this distribution system against lightning is performed by installing overhead ground wires over the high voltage wires, and connecting the overhead ground wires to the ground every 200 m. The ground resistance in this system is limited not to exceed $50\Omega$ and overhead ground wire and neutral wire are multiple parallel lines. Although overhead ground wire and neutral wire are installed in different locations on the same pole, this circuit configuration has duplicated functions of providing a return path for unbalanced currents and protecting the distribution system against induced lightning. Therefore, the purpose of this study is to analyze the induced lightning shielding effect according to the neutral wire installation structure of a 22.9kV distribution line in order to present a new 22.9kV distribution line structure model and characteristics. This study calculated induced lightning voltage by performing numerical analysis when an overhead ground wire is present in the multi-grounding type 22.9kV distribution line structure, and calculated the induced lightning shielding effect based on this calculated induced lightning voltage. In addition, this study proposed and analyzed an improved distribution line model allowing the use of both overhead wire and neutral wire to be installed in the current distribution lines. The result of MATLAB simulation using the conditions applied by Yokoyama showed almost no difference between the induced lightning voltage developed in the current line and that developed in the proposed line. This signifies that shielding the induced lightning voltage through overhead wire makes no difference between current and proposed distribution line structures. That is, this study found that the ground resistance of the overhead wire had an effect on the induced lightning voltage, and that the induced lightning shielding effect of overhead wire is small.

자연형 초공동화 운동체의 구속 직진운동 해석기법 연구 (A Study on the Motion Analysis of the Wire-guided Underwater Test Body in Natural Supercavitation)

  • 나영인;김선범
    • 한국군사과학기술학회지
    • /
    • 제17권3호
    • /
    • pp.296-303
    • /
    • 2014
  • This paper describes the simplified simulation method of the wire-guided underwater test body with natural supercavitation. In this paper, the simulation based model of the wire-guided underwater body with natural supercavitation is proposed by using preceding research and commercial flow-analysis software. By using the model, the 1-dimensional wire-guided body motion in natural supercavitation can be solved very fast with reliability. The suggested model is validated by the comparison of simulation results with experimental data.

Layer모델에 의한 와이어 메쉬 하프슬래브의 해석 (Analysis of Wire-Mesh Half Slab by Layer Model)

  • 이원호;이리형;정란;박칠림
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1994년도 봄 학술발표회 논문집
    • /
    • pp.73-80
    • /
    • 1994
  • This paper is to study the mechanical behavor and structural safety of the wire-mesh half slab by an analytical method. Layer model was adopted by modelling the wire-mesh half slab as a flexural member composed of free cantilever beam and vertical supports (walls or beams). Reasonable results for the prediction of ultimate strength of the half stab at each loading direction and design recommendations for the reinforcement detail at wall(beam)-slab joints are acquired. On the other hand, ductility capacity of the wire-mesh half slab was overestimated by not considering the brittleness of wire-mesh reinforcements pre-manufactured at the form of Kaiser Truss.

  • PDF

An Efficient No-Core Cut Pocketing CAM System for Wire-EDM

  • EL-Midany, Tawfik T.;Kohail, Ahmed M.;Tawfik, Hamdy
    • International Journal of CAD/CAM
    • /
    • 제6권1호
    • /
    • pp.167-172
    • /
    • 2006
  • Recently, wire-EDM became a necessity for many engineering applications, particularly in the dies making. No-Core cut process is helpful for operations in which falling slug can jam the machine or wire. In this paper a proposed CAM system (called NCPP) is introduced, to overcome the limitations of the existing CAM systems in the machining of No-Core cut. The proposed CAM system (NCPP) provides pocketing of No-core cut and optimal selection of the position of starting hole (wire threading point), to minimize toolpath length. It was written for data exchange between CAD-CAM-CNC machines. This data model will become part of the ISO (Data model for Computerized Numerical Controllers) international standard. The NCPP system has been implemented in Visual C++. Many examples are used to illustrate NCPP system. The results show that, NCPP saves the machining time by significant value. This value depends on the shape and complexity of the workpiece that is being cut.

와이어 컷 방전가공이 효율적인 NC 모의가공 시스템의 개발 (On the Development of NC Simulator System for Wire Cut EDM)

  • 유우식;김남웅;유정호
    • 대한안전경영과학회지
    • /
    • 제6권1호
    • /
    • pp.283-300
    • /
    • 2004
  • This paper describes the NC simulator system for Wire-cut electrodischarge machining. Electrodischarge Wire-cut machining is applicable to all materials including metals, alloys, and most carbides. Although CAM system generate the NC code considering electrodischarge conditions, incorrect Wire-cut tool path bring about fatal results. The simplest way of simulating a EDM process is to display the trajectory of Wire-cutter location by line segments. With this kind of simulation, the programmer can get a general idea about whether the wire is moving as planned but cannot locate gouging or excess material because only the wire location will be seen, not the changes in the workpiece as it is machined. The ideal way of simulating the EDM process is to display the solid model of the workpiece as it is machined. Therefore we propose the ideal NC simulator system for Wire-cut EDM.

와이어 컷 방전가공의 효율적인 NC 모의가공 시스템 개발에 관한 연구 (A Study for the Development of NC Simulator System of Wire Cut EDM)

  • 유우식;김남웅
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2003년도 추계학술대회
    • /
    • pp.285-290
    • /
    • 2003
  • This paper describes the NC simulator system for Wire-cut electrodischarge machining. Electrodischarge Wire-cut machining is applicable to all materials including metals, alloys, and most carbides. Although CAM system generate the NC code considering electrodischarge conditions, incorrect Wire-cut tool path bring about fatal results. The simplest way of simulating a EDM process is to display the trajectory of Wire-cutter location by line segments. With this kind of simulation, the programmer can get a general idea about whether the wire is moving as planned but cannot locate gouging or excess material because only the wire location will be seen, not the changes in the workpiece as it is machined. The ideal way of simulating the EDM process is to display the solid model of the workpiece as it is machined. Therefore we propose the ideal NC simulator system for Wire-cut EDM.

  • PDF

확률분포추정기법을 이용한 와이어로프의 결함진단 (Wire Rope Fault Detection using Probability Density Estimation)

  • 장현석;이영진;이권순
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1758-1764
    • /
    • 2012
  • A large number of wire rope has been used in various inderstiries as Cranes and Elevators from expanding the scale of the industrial market. But now, the management of wire rope is used as manually operated by rope replacement from over time or after the accident.It is caused to major accidents as well as economic losses and personal injury. Therefore its time to need periodic fault diagnosis of wire rope or supply of real-time monitoring system. Currently, there are several methods has been reported for fault diagnosis method of the wire rope, to find out the feature point from extracting method is becoming more common compared to time wave and model-based system. This method has implemented a deterministic modeling like the observer and neural network through considering the state of the system as a deterministic signal. However, the out-put of real system has probability characteristics, and if it is used as a current method on this system, the performance will be decreased at the real time. And if the random noise is occurred from unstable measure/experiment environment in wire rope system, diagnostic criterion becomes unclear and accuracy of diagnosis becomes blurred. Thus, more sophisticated techniques are required rather than deterministic fault diagnosis algorithm. In this paper, we developed the fault diagnosis of the wire rope using probability density estimation techniques algorithm. At first, The steady-state wire rope fault signal detection is defined as the probability model through probability distribution estimate. Wire rope defects signal is detected by a hall sensor in real-time, it is estimated by proposed probability estimation algorithm. we judge whether wire rope has defection or not using the error value from comparing two probability distribution.