• Title/Summary/Keyword: wire mesh reinforced shotcrete

Search Result 7, Processing Time 0.02 seconds

An Experimental Study on the Mechanical Properties and Rebound Ratios of SFRS with Silica Fume

  • Son, Young-Hyun;Chai, Won-Kyu
    • International Journal of Safety
    • /
    • v.8 no.2
    • /
    • pp.20-25
    • /
    • 2009
  • In this study, an experiment in the field was performed to analyze the mechanical properties and the influence of steel fiber and silica fume on the rebound ratios of shotcrete. The experimental parameters which are the reinforcing methods (steel fiber, wire mesh), steel fiber contents (0.0%, 0.5%, 0.75%, 1.0%), silica fume contents (0.0%, 10.0%), layer thickness (60 mm, 80 mm, 100 mm), and the placing parts (sidewall, shoulder, crown) were chosen. From the mechanical test, it was found that the flexural strength and toughness is significantly improved by the steel fiber and/or silica fume. According to the results for the side wall in this test, the larger the fiber contents are in case of steel fiber reinforced shotcrete, the less the rebound ratios are within the range of 20-35%, compared to the wire mesh reinforced shotcrte. And also, the reduced rebound ratios were very larger in using steel fiber reinforced shotcrete with silica fume content of 10%, and these results are true of the shoulder and the crown. respectively.

Mechanical Properties and Economic Evaluation of Steel Fiber Reinforced Shotcrete (강섬유보강숏크리트의 역학적 특성 및 경제성 평가)

  • 손영현;박우진
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.2
    • /
    • pp.122-129
    • /
    • 1998
  • A field experiment was performed to analyze the properties of SFRS(steel fiber reinforced shotcrete) against WMRS(wire mesh reinforced shotcrete) with some experimental parameters. The parameters were reinforcing methods(steel fiber and wire mesh), steel fiber contents(0.5%, 0.75%, and 1.0%), silica fume contents(0.0% and 10.0%), spraying thicknesses of layer(10㎝, 8㎝, and 6㎝), and spraying parts(side wall, shoulder, and crown). According to the analyzed results, the mechanical properties of SFRS such as compressive strength, flexural strength, and load-carrying capacity after cracks were improved. And the economic evaluation was also performed on the basis of the required thickness of the layer and other researcher's results for rebound ratios. From the results of this tests, it is found that the traditional WMRS may be substituted by the SFRS in the viewpoint of the economic evaluation as well as the mechanical properties. In additions, the silica fume, even if it is very expensive, can significantly improve the mechanical properties of the shotcrete regardless of mixing with or without the steel fiber.

  • PDF

A study on the flexural toughness characteristics of the half-circle type steel fiber reinforced shotcrete (반원형 강섬유보강 숏크리트의 휨인성 특성에 관한 연구)

  • Ji, Young-Hwan;Jeong, Ji-Su;Jeong, Chun-Kyo;Lee, Seung-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.2
    • /
    • pp.83-96
    • /
    • 2011
  • Currently, the commonly used tunneling method in Korea is NATM (New Austrian Tunneling Method). This method uses the rock bolt, shotcrete, and supporting system to maintain the strength of original soil and ensures the stability of tunnel by stabilizing the soil using the original strength of the soil in maximum after the excavation. In past years, wire-mesh reinforced shotcrete was common ones but currently steel-fiber reinforced shotcrete is being widely used for the tunnel construction site in Korea to save construction time with the advanced construction technology. The results further indicate that needs for the establishment of not only the specifications for shotcrete but the strengthening methods for the under reinforced shotcrete sections. Therefore, this study deals with the development of a new steel-fiber to ensure the stability of tunnels that are under reinforced with steel-fibers and to overcome the shortcomings of conventional method.

An Experimental Study on the Rebound Ratios of SFRS with Silica Fume (실리카흄 혼입한 SFRS의 리반운드율에 관한 실험적 연구)

  • 손영현;변형균;조용복
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.10a
    • /
    • pp.429-434
    • /
    • 1994
  • In this study, an experiment in the field was performed to analyze the variations of rebound ratios of SFRS with silica fume after fabricating the panels and placing the plain concrete of simulting a base rock with thickness 7cm. And the experimental parameters which are the reinforcing methods(steel fiber, wire mesh), steel fiber contents(0.0%, 0.5%, 0.75%, 1.0%), silica fume contents(0.0%, 10.0%), and the three parts(lower, middle, upper part) were chosen. According to the results of the lower part in this test, the larger the fiber contents are in case of steel fiber reinforced shotcrete, the less the rebound ratios are within the range of 20~35%, compared to the wire-mesh reinforced shotcrete with silica fume content of 10%, and these results are true of the middle and upper part, respectively. In addition, the four-stage phenomena of the rebound of SFRS were estimated on the base of a series of the test results.

  • PDF

Influence of Steel Fiber and Silica Fume on the Rebound Ratios of Shotcrete (강섬유와 실리카 흄이 숏크리트의 리바운드율에 미치는 영향)

  • 장동일;손영현
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.4
    • /
    • pp.125-133
    • /
    • 1998
  • In this study, an experiment in the field was performed to analyze the influence of steel fiber and silica fume on the rebound ratios of shotcrete. The experimental parameters which are the reinforcing methods(steel fiber, wire mesh), steel fiber contents(0.0%, 0.5%. 0.75%, 1.0%), silica fume contents(0.0%, 10.0%), and the three placing parts(side wall, shoulder, crown) were chosun. According to the results for the side wall in this test, the larger the fiber contents are in case of steel fiber reinforced shotcrete, the less the rebound ratios are within the range of 20~35%, compared to the wire mesh reinforced shotcrte. And also, the reduced rebound ratios were vary larger in using steel fiber reinforced shotcrete with silica fume content of 10%, and these results are true of the shoulder and the crown, respectively. In addition, the four-stage phenomenon for the rebound of the SFRS were estimated in the view of the co-action between steel fiber and coarse aggregate based upon the existing two-stage analysis method.

Steel Fiber Reinforcing Effect Analysis of Slab Panel Structure and Assessment Technics of Toughness (강섬유보강 패널구조의 보강효과 분석 및 인성평가 기법)

  • Jeon, Chan-Ki;Park, Sun-Kyu
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.2
    • /
    • pp.209-220
    • /
    • 1999
  • This paper is aimed to evaluate the effectiveness of flexural toughness of slab panel structures($60{\times}60{\times}10$) reinforced by steel fiber instead of wire mesh. Steel fiber used in this study is double hooked Dramix type fiber. And the fiber length is 60mm, diameter is 0.8mm, Various assessment methods of toughness index are used to estimate the proper effectiveness. In this experimental study, we find that Johnston, JCI-SF4 and EFNARC method are more effective to assess the flexural toughness of slab panels than the others. And the steel fiber is very effective alternative material to reinforce slab panel structures instead of wire mesh. Fiber volume fraction of 0.5~0.75% is more useful than the others in enhancing the post-peak energy absorption and toughness index by Johnston's $I_{5.5}$ assessment method. And the slab panels reinforcing with steel fiber are more resistant to crack propagation than wire mesh reinforcing slabs.

A Study on Reinforcement Method of Reinforced Soil Retaining Wall Through Field Experiment (보강토옹벽의 배부름현상 분석 및 보강 방법에 대한 실험적 연구)

  • Lee, Won-Hong;Mun, Byeong-Jo;Lee, Seuong-Yeol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.103-112
    • /
    • 2019
  • This study proposes a system to control the bulging phenomenon occurring in the reinforced earth retaining wall and to evaluate the reliability of the system by field experiment. In this study, drainage facilities were not installed in order to induce reinforcement earth retaining wall bulging, and the bulging was induced by rainfall. The induced bulging displacement exceeded the horizontal displacement criterion during the construction of FHWA. The retaining wall block was drilled and grouting was performed by inserting the nail into the drilling hole. The wire mesh is installed on the reinforcing surface and the head of the nail is connected horizontally so that the blocks of the reinforcing earth retaining wall can be supported with each other. In order to protect the reinforcements, the reinforcement surface was closed with shotcrete and a measuring device was installed to detect the progress of the displacement. After the reinforcement, the bulging were not found to progress any more, confirming the reliability of the system.