A Study on the Effect of Ceiling Type Air Conditioner on Sprinkler Head Operation (천장형 에어컨이 스프링클러 헤드 작동에 미치는 영향에 관한 연구)

  • Yi, Sunyoung;Yoon, Myong O;Lee, Youngju;Lee, Jun
    • Journal of Korean Society of Disaster and Security
    • /
    • v.13 no.1
    • /
    • pp.51-58
    • /
    • 2020
  • This paper analyzes the effect of airflow of ceiling air conditioner on the operation of sprinkler head using a simulation program. The simulation space is 10 m × 7 m × 3 m, and the size of the fire is 0.8 m × 0.8 m × 0.6 m. The cold air flow from the air conditioner is at 25℃ and the wind speed is divided into three cases : 10 ㎧, 8.5 ㎧, and 7.5 ㎧. Simulation results show that all cases had operating delays compared to when the air conditioner was not running, and the sprinkler head did not operate until 10 minutes had elapsed at 10 ㎧ wind speed. These results confirmed that the sprinkler head was delayed in the air conditioning space and the worst result of early evolution failure was observed in strong winds such as 10 ㎧.

Numerical Simulation and Comparison of Particle Dispersion and Air Quality with Domain Setting of Gwangyang Bay Area (광양만 권역의 영역 설정에 따른 입자확산 및 대기질 수치모의 비교)

  • Lee, Hyun-Mi;Lee, Hwa-Woon;Lee, Soon-Hwan
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.6
    • /
    • pp.591-605
    • /
    • 2010
  • Recirculation of airmass in coastal region occurs because of the change from land to sea breeze and was shown to produce a contrary result on air quality. This study examines the numerical simulation to analyze the effect of recirculation flow in Gwangyang Bay, Korea. For this purpose two case studies are performed by the WRF-FLEXPART-CMAQ modeling system, each for a different Meso-Synoptic Index. Additionally this research make a comparative study of large domain (Domain L) and small domain (Domain S). The horizontal wind fields are simulated from WRF. Changes in the land-sea breeze have an effect on the particle dispersion modeling. The numerical simulation of air quality is carried out to investigate the recirculation of ozone. Ozone is transported to eastward under strong synoptic condition (Case_strong) because of westerly synoptic flow and this pattern can confirm in all domain. However ozone swept off by the land breeze and then transported to northward along sea breeze under conditions of clear sky and weak winds (Case_weak). In this case re-advected ozone isn't simulate in Domain S. The study found that recirculation of airmass must be concerned when numerical simulation of air quality is performed in coastal region, especially on a sunny day.

Performance Evaluation of the High-Resolution WRF Meteorological Simulation over the Seoul Metropolitan Area (WRF 모형의 수도권 지역 상세 국지 기상장 모의 성능 평가)

  • Oh, Jun-Seo;Lee, Jae-Hyeong;Woo, Ju-Wan;Lee, Doo-Il;Lee, Sang-Hyun;Seo, Jihyun;Moon, Nankyoung
    • Atmosphere
    • /
    • v.30 no.3
    • /
    • pp.257-276
    • /
    • 2020
  • Faithful evaluation of the meteorological input is a prerequisite for a better understanding of air quality model performance. Despite the importance, the preliminary meteorological assessment has rarely been concerned. In this study, we aim to evaluate the performance of the Weather Research and Forecasting (WRF) model conducting a year-long high-resolution meteorological simulation in 2016 over the Seoul metropolitan area. The WRF model was configured based on a series of sensitivity simulations of initial/boundary meteorological conditions, land use mapping data, reanalysis grid nudging method, domain nesting method, and urban canopy model. The simulated results of winds, air temperature, and specific humidity in the atmospheric boundary layer (ABL) were evaluated following statistical evaluation guidance using the surface and upper meteorological measurements. The statistical evaluation results are presented. The model performance was interpreted acceptable for air quality modeling within the statistical criteria of complex conditions, showing consistent overestimation in wind speeds. Further statistical analysis showed that the meteorological model biases were highly systematic with systematic bias fractions (fSB) of 20~50%. This study suggests that both the momentum exchange process of the surface layer and the ABL entrainment process should be investigated for further improvement of the model performance.

The Performance Assessment of Special Observation Program (ProbeX-2009) and the Analysis on the Characteristics of Precipitation at the Ulleungdo (울릉도 특별관측 수행평가 및 강수특성 분석)

  • Kim, Ki-Hoon;Kim, Yeon-Hee;Kim, Do-Woo;Chang, Dong-Eon
    • Atmosphere
    • /
    • v.21 no.2
    • /
    • pp.185-196
    • /
    • 2011
  • The performance assessment in radiosonde observation on the special observation program (ProbeX-2009) is performed and the characteristics of precipitation using Auto Weather System (AWS) and radiosonde data in 2009 at the Ulleungdo are investigated. The launching time, observation time, and maximum altitude of radiosonde are satisfied with the regulation from Korea Meteorological Administration (KMA) and World Meteorological Organization (WMO) but the duration of observational time of radiosonde is much shorter than that of the ProbeX-2007 because the altitude of launching site is higher than others in 2007. From the analysis of trajectories of radiosonde, most radiosondes at the Ulleungdo tend to move into the east because the westerly prevail at the middle latitude. However, when the Okhotsk high is expanded to the Korean peninsula and the north-westerly winds strengthen over the East Sea as the subtropical high is retreated, radiosonde tends to move into the south-west and south-east, respectively. Maximum distance appears at the end of observation level before May but the level of maximum distance is changed into 100 hPa after June because the prevailing wind direction is reversed from westerly to easterly at the stratosphere during summer time. The condition of precipitation was more correlated with the dynamic instability except Changma season. Precipitation in 2009 at the Ulleungdo occurred under the marine climate so that total precipitation amounts and precipitation intensity were increased and intensified during nighttime. The local environment favorable for the precipitation during nighttime was while the wind speed at the surface and the inflow from the shoreline were strengthened. Precipitation events also affected by synoptic condition but the localized effect induced by topography was more strengthened at the northern part of Ulleungdo.

The Distribution of Heat Waves and 10 Cause in South Korea (한국의 열파 분포와 그 원인에 관한 연구)

  • Kim, Ji-Youn;Lee, Seung-Ho
    • Journal of the Korean Geographical Society
    • /
    • v.42 no.3 s.120
    • /
    • pp.332-343
    • /
    • 2007
  • This study aims to examine the distribution of heat waves and to understand its cause for 33 years$(1973\sim2005)$ from 60 weather stations in Korea. Heat wave is defined as a period of 3 or more days with a daily maximum temperature exceeds the 95th percentile. In the inland of Chungcheong region, the Chungcheong western costal region, the inland of Jeolla region, the inland of Gyeongsang region and the southern region of Jeju island, heat wave days appeared more than 160 days. In the middle region of eastern costal and the northern region of Jeju island, heat wave days were less than 110 days. In regions that were heavily influenced by southwesterly winds during the occurrence of heat waves, such as the inland of Chungcheong region, the Chungcheong western costal region, the inland of Jeolla region and the inland of Gyeongsang region, heat waves continued for the longer term.

Analysis of Peak Wind Pressure Coefficients of Penetration Type and End Type Pilotis (관통형과 단부형 필로티 천장부의 피크풍압계수 특성 분석)

  • You, Jang-Youl;Kim, Geun-Ho;Chae, Myung-Jin;Kim, Young-Moon;You, Ki-Pyo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.2
    • /
    • pp.59-67
    • /
    • 2018
  • Various pilotis are installed in the lower part of high rise buildings. Strong winds can generate sudden airflow around the pilotis, which can cause unexpected internal airflow changes and may cause damage to the exterior of the piloti ceiling. The present study investigates the characteristics of peak wind pressure coefficient for the design of piloti ceiling exteriors by conducting wind pressure tests on high rise buildings equipped with penetration-type and end-type pilotis in urban and suburban areas. The minimum peak wind pressure coefficient for penetration-type piloti ceilings ranges from -2.0 to -3.3. Minimum peak wind pressure coefficient in urban areas was 30% larger than in suburban areas. In end-type piloti ceilings, maximum peak wind-pressure coefficient ranges from 0.5 to 1.9, and minimum peak wind-pressure coefficient ranges from -1.3 to -3.6. With changes in building height, peak wind pressure coefficient decreases as the aspect ratio increases. Peak wind-pressure coefficient increases with taller pilotis. On the other hand, when piloti height decreases, the absolute value of the minimum peak wind pressure coefficient increases.

A Study on the Distribution of the Peak Wind Pressure for Rooftop Signboards (건물 옥상에 설치되는 옥상 간판의 피크풍압 분포에 대한 연구)

  • Nam, Byung-Hee;You, Jang-Youl;Lee, Nam-Hun;You, Ki-Pyo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.2
    • /
    • pp.79-86
    • /
    • 2018
  • Unlike other types of outdoor advertisements, rooftop signboards are installed on the roofs of buildings, rather than on their outer walls. This means that the area of a rooftop signboard is commonly larger than that of a general outdoor signboard. Moreover, as such signboards are greatly influenced by the wind, they can suffer a lot of damage from typhoons and strong winds every year. However, there is no wind load specification for rooftop signboards. In this study, wind pressure experiments were conducted to investigate the peak wind pressure on each side of rooftop signboards installed on the roofs of 5-15 story buildings in a city center. The minimum peak wind pressure coefficient was -3.0 at the bottom edges of the front and back of the rooftop signboards and -2.0 along the entire length of the sides. As the height of the rooftop signboard increased with the increasing height of the buildings, the peak value was found to be larger than the absolute peak value for the minimum peak wind pressure coefficient. The maximum and minimum peak wind pressure distributions of the rooftop outdoor signboards were influenced by the position of the signboard and the wind angle.

Development of a Large Capacity Hybrid-Type Linear Motor Damper for the vibration Control of Building Structures (건축 구조물의 진동 제어용 하이브리드형 대용량 리니어 모터 댐퍼의 개발)

  • Jeong, Sang-Seop;Jang, Seok-Myeong;Lee, Seong-Ho;Yun, In-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.11
    • /
    • pp.601-611
    • /
    • 2002
  • As resent trends in structural construction have been to build taller and larger structures than any time in the past, they have had high flexibility and low damping that can cause large vibration response under severe environmental loading such as earthquakes, winds, and mechanical excitations. The damper with mass and sqring is one aproach to safeguarding the structure against excessive vibrations. In this paper, a large capacity hybrid-type linear motor damper(LMD) was designed and fabricated for the application to the vibration control of a large building structure model. It has been designed to be able to move the damper mass, 1,500 kg up to ${\pm}250mm$ strokes at the first mode natural frequency of the building structure model, ${\pm}0.51Hz$. Linear motor is consisted of the fixed coil and the movable NdFeB permanent magnets field part. The PM field part composed magnet modules and iron yoke, is the damper mass itself, 1500kg. LMD therefore has a simplified structure and requires a few elements in the driving system, being compared with a rotary motor damper and a hydraulic damper. However, the manufacture of large PM linear actuator is difficult because of the limit of PM size and the attraction and repulsion at the assembly of PM. Therefore, large damper system is manufactured and tested for dynamic characteristics and frequency response.

ASSESSMENT OF WIND CHARACTERISTICS AND ATMOSPHERIC DISPERSION MODELING OF 137Cs ON THE BARAKAH NPP AREA IN THE UAE

  • Lee, Jong Kuk;Kim, Jea Chul;Lee, Kun Jai;Belorid, Miloslav;Beeley, Philip A.;Yun, Jong-Il
    • Nuclear Engineering and Technology
    • /
    • v.46 no.4
    • /
    • pp.557-568
    • /
    • 2014
  • This paper presents the results of an analysis of wind characteristics and atmosphere dispersion modeling that are based on computational simulation and part of a preliminary study evaluating environmental radiation monitoring system (ERMS) positions within the Barakah nuclear power plant (BNPP). The return period of extreme wind speed was estimated using the Weibull distribution over the life time of the BNPP. In the annual meteorological modeling, the winds from the north and west accounted for more than 90 % of the wind directions. Seasonal effects were not represented. However, a discrepancy in the tendency between daytime and nighttime was observed. Six variations of cesium-137 ($^{137}Cs$) dispersion test were simulated under severe accident condition. The $^{137}Cs$ dispersion was strongly influenced by the direction and speed of the main wind. A virtual receptor was set and calculated for observation of the $^{137}Cs$ movement and accumulation. The results of the surface roughness effect demonstrated that the deposition of $^{137}Cs$ was affected by surface condition. The results of these studies offer useful information for developing environmental radiation monitoring systems (ERMSs) for the BNPP and can be used to assess the environmental effects of new nuclear power plant.

Embossed Structural Skin for Tall Buildings

  • Song, Jin Young;Lee, Donghun;Erikson, James;Hao, Jianming;Wu, Teng;Kim, Bonghwan
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.1
    • /
    • pp.17-32
    • /
    • 2018
  • This paper explores the function of a structural skin with an embossed surface applicable to use for tall building structures. The major diagrid system with a secondary embossed surface structure provides an enhanced perimeter structural system by increasing tube section areas and reduces aerodynamic loads by disorienting major organized structure of winds. A parametric study used to investigate an optimized configuration of the embossed structure revealed that the embossed structure has a structural advantage in stiffening the structure, reducing lateral drift to 90% compared to a non-embossed diagrid baseline model, and results of wind load analysis using computational fluid dynamics, demonstrated the proposed embossed system can reduce. The resulting undulating embossed skin geometry presents both opportunities for incorporating versatile interior environments as well as unique challenges for daylighting and thermal control of the envelope. Solar and thermal control requires multiple daylighting solutions to address each local façade surface condition in order to reduce energy loads and meet occupant comfort standards. These findings illustrate that although more complex in geometry, architects and engineers can produce tall buildings that have less impact on our environment by utilizing structural forms that reduce structural steel needed for stiffening, thus reducing embodied $CO^2$, while positively affecting indoor quality and energy performance, all possible while creating a unique urban iconography derived from the performance of building skin.