Abstract
Unlike other types of outdoor advertisements, rooftop signboards are installed on the roofs of buildings, rather than on their outer walls. This means that the area of a rooftop signboard is commonly larger than that of a general outdoor signboard. Moreover, as such signboards are greatly influenced by the wind, they can suffer a lot of damage from typhoons and strong winds every year. However, there is no wind load specification for rooftop signboards. In this study, wind pressure experiments were conducted to investigate the peak wind pressure on each side of rooftop signboards installed on the roofs of 5-15 story buildings in a city center. The minimum peak wind pressure coefficient was -3.0 at the bottom edges of the front and back of the rooftop signboards and -2.0 along the entire length of the sides. As the height of the rooftop signboard increased with the increasing height of the buildings, the peak value was found to be larger than the absolute peak value for the minimum peak wind pressure coefficient. The maximum and minimum peak wind pressure distributions of the rooftop outdoor signboards were influenced by the position of the signboard and the wind angle.
Keywords
Hoarding on roof; Outdoor billboard; Outdoor structure; Wind pressure coefficient; Wind tunnel experiment;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Choi, Y. S., Jeong, S. H., & Choi, S. H., "Wind load estimation for the outdoor advertisement", Korean Society of Civil Engineers, pp.607-608, 2014
2 You, J. Y., Nam, B. H., & Kim, Y. M. (2017). Distribution of Wind Pressure Coefficients Depending on Separation Distances of Protruding Signboard. Proceedings of the Architectural Institute of Korea, Republic of Korea, Vol.37, No.2, pp.670-673
3 Jung, W. Y., "Developed safety installation standard and high performance attaching product to reduce damage of outdoor advertisement structure by strong wind", Gangneung-Wonju National University Industry Academy Cooperation Group, 2013.
4 Masuyama, Y., Nakamura, O., Okuda, Y., Ito, S., Kikuchi, H., Noda, H., . . . Uematsu Y., "Peak Wind Force Coefficients of Hoardings on Roof", Wind Engineers, Vol.36, No.4, pp.362-375, 2011   DOI
5 Letchford, C. W., "Wind loads on rectangular signboards and hoardings", Journal of Wind Engineering and Industrial Aero- dynamics, Vol.89, No.2, pp.135-151, 2001   DOI
6 Enforcement Decree of the act on the Management of outdoor Advertisements etc and Promotion of outdoor Advertisement Industry, 2016.
7 Seoul outdoor Advertisement status Book, Korea out of Home Advertising Center, 2014.
8 Korea Building Code, 2016