Elements and Apply Techniques for Improving the Insulation of Rural Houses (농촌주택의 단열 향상을 위한 요소와 적용기술 - 선행연구와 현장사례조사를 중심으로 -)

  • Kwon, Soon Chan;Kim, Eun Ja;Lim, Chang Su;Lee, Yoo Kyoung
    • Journal of Korean Society of Rural Planning
    • /
    • v.21 no.4
    • /
    • pp.187-196
    • /
    • 2015
  • Among the factors of living environment, the one that is the most closely related with our living is the building. It is one of the biggest reasons for energy consumption as it forms 36% of the total energy consumption. Technologies equipped with excellent energy performance can hardly be applied to rural areas that are relatively poorer. Still, 89.8% rural residents are living in detached houses, and backward houses increase their financial burden and result in reduced insulation performance. Accordingly, this study is going to review the latest research written after 2000 dealing with rural houses and their insulation. The purpose of this study is to analyze the factors of insulation and how to improve insulation performance, conduct field research to find out how to apply low energy technologies applicable to houses with the subjects of experimental houses, the passive houses located in Jecheon City, Hongcheon Saldun zero energy houses, and energy independence villages, and find out how to perform follow-up research on insulation for rural houses. According to the findings, the latest research on insulation for rural houses is mostly focused on walls as well as windows and doors. Also, as ways to improve insulation performance, it suggests us to use high performance insulators, introduce new regeneration energy technology, and secure hermeticity. In addition, through field research, this author could find out low energy technologies applicable to houses such as solar energy facilities and heat recovery systems. Advanced research on insulation for rural houses has been focused on how to use materials or new regeneration energy, so follow-up research will have to consider the types of farming area or the residents' mode of living.

An Analysis of the Rhythms of the Chapel at Ronchamp through Henri Lefebvre's 'Rhythmanalysis' (앙리 르페브르의 '리듬분석'을 통한 롱샹 성당의 리듬분석)

  • Kim, Young-Hee
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.2
    • /
    • pp.78-87
    • /
    • 2015
  • This study aims to grasp the vital rhythm of the Chapel at Ronchamp by analyzing its rhythm through Henri Lefebvre's 'rhythmanalysis' in an effort to show the possibility of approaching the presence of this chapel. For the purpose of this study, Lefebvre's thought of rhythmanalysis was first contemplated, and a case study analysis was conducted on the concept and presence of the chapel in the design process. On this basis, examples of the chapel's rhythms were analyzed through Lefebvre's dialectical analysis of the triad of time(melody), space(harmony) and energy(rhythm). The results of analysis are as follows: First, the concept intended by Le Corbusier in the process of designing the Chapel at Ronchamp is expressed as the acoustic form, the modulor corresponding to the scale of the music, the light and shadow of counterpoint, and the opposite composition of musical changes. Consequently, the concept-mediated presence of this chapel is the presence of music. Second, at the Chapel at Ronchamp, a Lefebvre's rhythmanalyst experiences, or rather senses, two vital rhythms of an antithetical unity (i.e., acoustic curved rhythm and modulor-generated linear rhythm), with reference to his/her own rhythms. These rhythms are a dialectical union of spatiality of melodies temporalized through continuity, (i.e., acoustic curved form and modulor-generated linear form), and temporality of harmonies spatialized through simultaneity (i.e., light and shadow, materials and color, form of interpenetration, and stairs or windows/doors). These rhythms carry the measures generated by music-specific repetitions and differences in movements(energy). Consequently, the rhythm-mediated presence of this chapel is also the presence of music. In conclusion, the Chapel of Ronchamp indicates that an approach toward its presence can be realized through vital rhythms derived from Lefebvre's 'rhythmanalysis'. This study holds significance as an analysis of spatial rhythm and presence, employing a philosophical thought.

A Comparative Study of Self Esteem and Reactions on Landscape Montage Test between Scientifically Gifted High School Students and General High School Students (과학영재 고등학생과 일반계 고등학생의 자아존중감과 풍경구성법 반응특성에 관한 비교 연구)

  • Song, Soonhyun;Park, Kyungbin
    • Journal of Gifted/Talented Education
    • /
    • v.24 no.2
    • /
    • pp.313-333
    • /
    • 2014
  • The purpose of this study was to examine self esteem and reactions on LMT projective technique to a group of scientifically gifted high school students and general high school students. For that purpose, 113 participants from scientifically gifted high school and general high school were asked to fill out self esteem questionnaire and draw a LMT. The results were analyzed by using SPSS.PASW18. The results are as follows: First, overall self esteem of gifted students were higher than general students. Second, reactions on LMT of gifted students and general students were examined. As a result, there were statistically significant differences in four items; integration of landscape composition, expression of distance and space, number of additional items, existence of doors and windows. The result of this study showed significant differences between the two groups in self esteem and LMT scores.

Measurement and Evaluation of the Acoustic Performance in the Royal Palace Buildings of Joseon Dynasty - Focused on Pyeonjeon and Chimjeon - (조선 궁궐 건축물의 음향성능 측정 및 평가 - 편전 및 침전을 중심으로 -)

  • Kim, Nam-Wook;Kim, Myung-Jun;Han, Wook
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.12
    • /
    • pp.1269-1280
    • /
    • 2009
  • This study was performed to construct sound performance DB of royal palace buildings and to examine the special quality more scientifically. Research target of royal palace were Changdeokgung and Gyeongbokgung. Sound insulation performance between the adjacent room and facade, room acoustics of Pyeonjeon and Chimjeon which is representative building in royal palace were examined through field measurement. Measured values of RT($T_{mf}$) at Pyeonjeon were 0.78 sec. and 1.03 sec. in Seonjeongjoen and Sajeongjoen, respectively. The RTs of both Pyeonjeon buildings were estimated suitable for speech and lecture considering their volume. The RT($T_{mf}$)s at Chimjeon were measured in range of 0.29~0.55 sec. This meant that the acoustic energy in rooms was decreased by sound transmission through mulberry paper(Hanji) of traditional windows and doors. As a sound insulation performance, the single-number quantities($D_{ls,2m,nT,w}$) of the building facades in Pyeonjeon and Chimjeon were measured 4~20 dB. Also the single-number quantities($D_{p,w}$) between the adjacent rooms in Chimjeon were measured 3~18 dB. Sound insulation performance of traditional building elements such as window and door depended strongly on their layers and area.

Analysis of the Causes of Casualties of Jecheon Sports Center Fire - Focus on an Initial Response and Management - (제천 스포츠센터 화재의 다수 사상자 발생원인 분석 -초기대응과 관리적인 측면을 중심으로-)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.57-66
    • /
    • 2018
  • A sports center fire in Jecheon that caused 29 deaths and 40 injuries was analyzed based on initial response and management in order to investigate the causes of the casualties. The aspects of initial response included delay of reporting 119, not being guided to the exit for the body scrubber on the $2^{nd}$ floor for escape, opening the fire doors of the exits on the $1^{st}$ floor and $3^{rd}$ floor, not closing the fire door of the main stairs on the $3^{rd}$ floor, and not doing an emergency broadcast. The management aspects included closing the alarm valve of the sprinkler system on the $1^{st}$ floor, starting-stop of the fire pump controller, neglecting leakage of water and electricity between the false ceiling and ceiling in the parking lot, hiding the exit light in the ladies bathroom lounge on the $2^{nd}$ floor and piling up things in the exit, neglecting the button of an automatic door on the $2^{nd}$ floor, conventional fire safety management, insufficient inspection of fire equipment, and not working fire shutters and smoke exhaust windows.

Floor Plan Analysis of Detached Houses for the Low-income Households

  • Kim, Junghwa;Ahn, Byunglip;Jang, Cheolyong;Jeong, Hakgeun;Kim, Jonghun
    • KIEAE Journal
    • /
    • v.14 no.3
    • /
    • pp.39-45
    • /
    • 2014
  • Energy poverty has been defined as low-income households who paid energy cost more than 10% of their ordinary income. Therefore, there are various subsidy programs focused on house remodeling for low-income households and one of them is the Home Energy Efficiency Assistance Program which have done by Korea Energy Foundation since 2007. The aim of the program is to improve the thermal performance of dilapidated dwellings and analyzed the detached house for the low-income households to develop the building typology. The database contained approximately 3,061 households which was obtained from the program in 2013 and the results of the study were like this; 1) For the shape of residential houses, the number of rectangular shaped building was higher than non-rectangular shaped ones. 2) For the orientation of buildings, the south layout of the detached housing was dominant to gain heating energy into buildings. 3) For the floor area, the average floor area was $44.2m^2$, although its size varied wide variations, which range from $6.3m^2$ to $107.1m^2$. 4) For the windows and doors, the south-facing window was larger than the other side. Finally it would be possible to determine the characteristics of residential houses for low-income families. A future study could establish typology of low-income housing that it would estimate the performance of each model building before and after the retrofit to improve the energy performance.

Analysis on Influencing factors and Actual State of Indoor Air Quality by Cooling in Private Institute Classrooms (학원교실의 냉방시 실내공기질 실태와 영향요인 분석)

  • Choi, Yoon-Jung;Lee, Hye-Jin;Lee, Ji-Youn
    • Korean Journal of Human Ecology
    • /
    • v.17 no.5
    • /
    • pp.1001-1013
    • /
    • 2008
  • The purpose of this study were to make clear the actual state of indoor air quality by cooling in private institute classrooms and to analyze influencing factors on indoor air quality. The measurements of physical elements and observations of architectural characteristics and living conditions were carried out in each 1 classroom of 5 private institutes. Measuring elements were indoor temperature, relative humidity, $PM_{10}$, HCHO, CO, and $CO_2$ concentration. As results, the averages of indoor temperature each classroom were $21.7\sim28.1^{\circ}C$. 3 classrooms were lower than the Maintenance standard($26\sim28^{\circ}C$) of School Health Law. The means of relative humidity were 48$\sim$63%, all classrooms were ranged within the standard(30$\sim$80%). The means of $PM_{10}$ concentration were 2.1 $\sim$ 17 $\mu g/m^3$, all classrooms were kept within the standard(100 $\mu g/m^3$). The means of HCHO concentration were 0.02$\sim$0.16 ppm, 2 classrooms were exceed the standard(0.1 ppm). The means of CO concentration were 1.4$\sim$3.6 ppm, all classrooms were kept within the standard(10ppm). The means of $CO_2$ concentration were 1,593$\sim$3,819 ppm, all classrooms were exceed the standard(1,000ppm). The results of analysis on influencing factors of the physical elements are as follow; the air conditioner set of temperature, personal necessities like hair spray, teacher's smoking in corridor, windows and doors opening time, the number of students, and volume of classroom.

Structural Performance of Hybrid Coupled Shear Wall System Considering Connection Details (접합부 상세에 따른 복합 병렬 전단벽 시스템의 구조 성능)

  • Park, Wan Shin;Yun, Hyun Do;Kim, Sun Woong;Jang, Young Il
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.3
    • /
    • pp.128-137
    • /
    • 2012
  • In high multistory buildings, hybrid coupled shear walls can provide an efficient structural system to resist horizontal force due to wind and seismic loads. Hybrid coupled shear walls are usually built over the whole height of the building and are laid out either as a series of walls coupled by steel beams with openings to accommodate doors, elevator walls, windows and corridors. In this paper, the behavior characteristics of hybrid coupled shear wall system considering connection details is examined through results of an experimental research program where 5 two-thirds scale specimens were tested under cyclic loading. Such connections details are typically employed in hybrid coupling wall system consisting of steel coupling beams and reinforced concrete shear wall. The test variables of this study are embedment length of steel coupling beam and wall thickness of concrete shear wall. The results and discussion presented in this paper provide fundamental data for seismic behavior of hybrid coupled shear wall systems.

An Experimental Study on the Fire Investigation to the Broken Plane Types of Glass (유리 파단면의 화재감식에 관한 실험적 연구)

  • Mun, Yong-Soo;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.4
    • /
    • pp.105-109
    • /
    • 2008
  • The purpose of this study is to distinguish the causes of broken glass on doors or windows when it is originally kept among the remains on the floor in fire site - whether it was broken due to heating or outer power-through test and characteristics of the broken plane including the pattern on the plane. Addition to it, the study tries to find characteristics to judge the point and direction of breakdown through the analysis of glass broken by outer power. With two assumed causes - a) breakdown due to heating and b) breakdown due to outer power-3 pieces of glass plates ($30cm{\times}30cm{\times}5mm$) were tested for each case, getting the results as following: First, for the glass broken due to the change of temperature, the broken plane is of slow and smooth curve without any pattern. Second, for the glass broken due to outer power, with the impact point as the center, the glass shows breakdown of radial type and the side shows breakdown of near-perpendicular type. The far the broken piece is from the impact point, the bigger the size is. The broken piece at the impact point is of long triangle type and the two long planes of the triangle shows semi-arc with the center of breakdown point and the other plane shows opposite pattern. Third, when glass that is damaged by outer power is heated, damaged forms and side patterns of the glass that is damaged by outer power are heated and disappeared.

A study on the Architectural Characteristics of Kyungduk-Dan and Manun-Jae in Miryang -Mainly about the Characterics of Traditional Houses in modern era(1876-1945)- (밀양(密陽) 경덕단(景德壇)과 만운재(萬雲齋)의 건축적 특성 - 근대한옥의 성격을 중심으로 -)

  • Lee, Ho-Yeol
    • Journal of architectural history
    • /
    • v.10 no.1 s.25
    • /
    • pp.9-23
    • /
    • 2001
  • This study is for the Kyungduk-Dan(as a altar of Milsung-Daegun) and The Manun-Jae the characteristics(lay out and planning, window patterns, structure, materials) of the the Korean traditional house during the modern era. Before Manun-Jae was used for the house. The Kyungduck-Dan was constructed in August according to the Lunar Calender in 1927. The Manun-Jae(house for Ki-hun Kang, millionaire ) was completed in 1924. Modern Architectures brought to Korea with the bricks, the tiles, the flash doors, the plate grasses, the brass hardwares. These architectural material was used in positive. During the construction of Manun-Jae in 1924, it happened the architectural exchage among a korean, a chinese and a japanese constructor. Though using the air exhaust valve at the kitchen of Ukyung-Kak( old Anchae), it could be assume that the modern convenience and the improvement of residential environments was considered at that period during the construction of Manun-Jae. That construction was elected with the brick($222mm{\times}106mm{\times}50mm$), the chinese colored tile and plate glass such a modem materials. The new shape of the korean lattice window and the wooden flash-door with glass was used. In Ukyung-Kak, the Chan-Maru(service space) and the kitchen such as a service space or concise utility zone was organically connected. Especially, considered the domesitic activity and circulation, the western kitchen sink and the Chan-Maru(service space) was rationally placed. At the Manun-Jae and the Kyungduck-Dan, the architectural characteristic is that the new shape of windows was used. The lattice window at the Ondol room of Ukyung-Kak, was rgadually added the plate glass and the wood plate. The lattice window with the grid shape at kitchen of that building was adapted japanese grid lattice window in korea at that period. It is the sample that korean traditional house was typically influenced from the japanese resident culture. The Manun-Jae and the Kyungduck-Dan as the modern house kept the form of korean traditional architecture, and was partially adapted a modern characteristic space and modern architectural materials. During the japanese occupancy, these residence can be showed the transition in formally.

  • PDF