• Title/Summary/Keyword: window system

Search Result 1,658, Processing Time 0.032 seconds

The optimal window system of office buildings considering energy efficiency (에너지 효율로 본 상업용 건물의 적정 창호에 관한 연구)

  • Yoo, Ho-Chun;Oh, Young-Ho;Park, Seung-Kil
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.53-60
    • /
    • 2005
  • The purpose of this study is to improve energy efficiency of windows in office buildings through the evaluation of their heating, cooling and illumination load. Energy efficiency is influenced by window size which is determined at the early stage of building design. The process of this study is as follows. First, energy performance is analysed according to the various rates of windows through computer simulation (ECOTECT). Then, the annual heating, cooling and illuminating loads according to the different window sizes are compared one another. Results indicated that the optimal window size considering energy efficiency is 50% of the surface area. When the window size is 50% of the surface area, annual maintenance expense is also smallest. Since the cost of cooling is larger than that of heating, too low indoor air temperature in summer is unfavorable based on the reasonable annual maintenance expenses.

The Evaluation of the Temperature Characteristics at the Spendrels of Curtain wall with a-Si BIPV Window System (스팬드럴 부분 BIPV창호 적용 및 후면마감재 구성에 따른 온도특성 분석 연구)

  • Kim, Dong-Su;Oh, Myung-Hwan;Yoon, Jongl-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.165-170
    • /
    • 2012
  • This study aims to analyze the characteristics of temperature variation of Spandrels. According to the change of SHGC of Window system, air space, insulation performance and absorption factor of inner surface at the Spandrels, It was firstly estimated by using simulation. Secondly, measured to minimize the temperature-rise of inner surface temperature and the intermediate air temperature by using Full-scale Mock-up based on the result of simulation analysis. As a result, it turns out that low SHGC window system such as BIPV system had an advantage of reducing the window surface temperature, and the surface temperature of clear window system was all higher than BIPV system on simulation results. In the experiment results, it had some advantages of increasing the Spandrels volume, decreasing insulation performance and lower absorption factor.

  • PDF

A Development of Safety Window System Module Considering Active Safety Technology (능동적 안전성을 고려한 윈도 세이프티 모듈의 개발)

  • Lee, Jong-Soon;Son, Il-Moon;Kwak, Hyo-Yean
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.3
    • /
    • pp.23-29
    • /
    • 2008
  • It is necessary to develope the active safety system in terms of driver's safety and convenience. In this paper, we were developed the non-contact type of safety window system operated by the initial value of feedback control such as the output signal of photo sensor. It was designed based on the control algorithm with an improved load sensitivity. Therefore, compared with the existing system, it is possible to prevent the occurrence of a mull-function. Also, it has a convenient functions of the window such as an auto up/down and closing, and has a response times better. It can be installed the various types of common vehicles that have the different movement distance and speed of window. In conclusion, the developed system may be adapted the vehicle commercially.

Numerical analysis of solar heat gain on slim-type double-skin window systems - Heat transfer phenomena with opening of windows and vent slot in summer condition - (전산유체 해석을 통한 슬림형 이중외피 창호의 태양열 취득량 분석 - 높은 태양고도 및 하절기 냉방조건에서의 자연환기구 적용 및 창문 조절 방식별 비교 -)

  • Park, Ji-Ho;Oh, Eun-Joo;Cho, Dong-Woo;Cho, Kyung-Joo;Yu, Jung-Yeon
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.69-75
    • /
    • 2017
  • Purpose: Heat transfer analysis of recently developed 'slim type double-skin system window' were presented. This window system is designed for curtain wall type façade that main energy loss factor of recent elegant buildings. And the double skin system is the dual window system integrated with inner shading component, enclosed gap space made by two windows when both windows were closed and shading component effectively reflect and terminate solar radiation from outdoor. Usually double-skin system requires much more space than normal window systems but this development has limited by 270mm, facilitated for curtain wall façade buildings. In this study, we estimated thermophysical phenomena of our double-skin curtain wall system window with solar load conditions at the summer season. Method: A fully 3-Dimentional analysis adopted for flow and convective and radiative heat transfer. The commercial CFD package were used to model the surface to surface radiation for opaque solid region of windows' frame, transparent glass, fluid region at inside of double-skin and indoor/outdoor environments. Result: Steep angle of solar incident occur at solar summer conditions. And this steep solar ray cause direct heat absorption from outside of frame surface rather than transmitted through the glass. Moreover, reflection effect of shading unit inside at the double-skin window system was nearly disappeared because of solar incident angle. With this circumstances, double-skin window system effectively cuts the heat transfer from outdoor to indoor due to separation of air space between outdoor and indoor with inner space of double-skin window system.

An Optimized Design and Simulation Analysis of Natural Ventilation Window System classified by Apartment type (주거용 건물 유형별 자연환기시스템의 최적 설계 및 해석)

  • Choi, Gyeong-Seok;Jeong, Young-Sun;Kang, Jae-Sik;Lee, Seung-Eon;Jeong, Yeong-Yong
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.685-688
    • /
    • 2009
  • On account of Indoor Air Quality(IAQ) deterioration by reason of high insulation and air tightness for energy saving, absence of energy efficiency ventilation system development that can be domestic existing window system, the cost increase and the energy addition loss by mechanical ventilation for IAQ improvement, the ventilation obligation making design standard was prepared by a social and technical background and the necessity. In this study, an optimized design and simulation Analysis of natural ventilation window system classified by Apartment type was evaluated by CFD Computational analysis.

  • PDF

A Study on Sidelobe Reduction Using Kaiser Window in Ultrasonic Imaging System (초음파 영상시스템에서 카이저 윈도우를 이용한 사이드 로브 감축에 관한 연구)

  • Na, Byeong-Yoon;Ahn, Young-Bok;Jeong, Mok-Kun
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.189-200
    • /
    • 1996
  • In this paper, we compared the performance of the Kaiser window with those of others as a weight function of well known anodization technique for regression of side lobe in a field pattern resulted from focusing of transducer array. The Kaiser window is an window providing many types of curve with several variables. In order to compare performance of the Kaiser window as the weight function, anodization results of the previously used Hamming window function and the Matched Gaussian function are compared Result of computer simulation, the pertormance of Kaiser window with $\delta$=0.0025 in side lobe regression was better than that of Hamming window or Matched Gausian function.

  • PDF

Active Window to Reduce the Exterior Noise Flowed Through the Open Window (열린 창문을 통해 유입되는 소음을 저감하는 능동소음제어 창문)

  • Kwon, Byoung-Ho;Park, Young-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.9
    • /
    • pp.820-827
    • /
    • 2011
  • Recently, noise has been regarded as one of the most notorious and frequent environmental pollutions which can be often encountered not only in the living space but also in the industrial site. Studies on physiological and psychological effects of long-term noise exposure to human being have commanded the public interest on noise issues. Since environmental noises such as traffic noise and construction noise is mainly flowed through the open window, it is necessary to develop the active noise control system to reduce it inside the building. Although control speakers and microphones for the noise signal measurement in the control region are essential for the conventional active noise control methods, it is impossible to implement them in the control region in the building environment because the control region is the living quarter and they may hinder activities of the residents. Therefore, we proposed the active window system to reduce the exterior noise flowed through the open window with microphones installed outside the window and control speakers installed at the frame of the window. To confirm the performance of the proposed active window, we carried out the simulation and experiment using active window system with 8 control speakers. Simulation results showed the noticeable noise reduction effect inside the control region within the frequency range without the spatial aliasing. Experimental result showed that the total acoustic potential energy inside the room of the scale model is reduced to about 10dB within the interest of frequency range.

An Empirical Study on Trade Facilitation by the Korean Government's Single Window System

  • Cheolkyu Maeng
    • Journal of Korea Trade
    • /
    • v.27 no.1
    • /
    • pp.101-118
    • /
    • 2023
  • Purpose - Korea became a trillion-dollar trading country in 2011. With the exponential increase in Korea's trade volume over the past decades, trade-related administrative burdens per capita for Korea Customs became enormous, for which the government established the Single Window, a trade-facilitating system, in 2004 to enhance the efficiency of customs-clearing procedures for traders. This paper focuses on finding whether the Korean Single Window system affects the country's trade facilitation positively through an empirical methodology. Design/methodology - To find empirical evidence that Single Window affects trade facilitation for the customs-clearing procedure, this study assumes that a time-efficient environment enables the handling of the increase in trade volume, under which four independent variables related to import customs-clearing procedures and two dependent variables to import were adopted for empirical analysis. The import customs procedures are classified into four steps from port entry to declaration acceptance. To understand the relationship between variables, scattered plots and correlation coefficients were calculated. Eight hypotheses were set and underwent simple linear regression. The data for analysis were collected by Korea Customs, and were about the lead time of import, the volume of imports in million USD, and the number of import declarations reported to customs offices on a monthly basis from 2005 to 2013. Findings - Six of the eight hypotheses showed the statistically significant result that lead time in the import customs-clearing procedure positively affects the number of import declaration reports and import volume. Specifically, Hypothesis 1, Hypothesis 2, and Hypothesis 3 strongly support the assumption lead time in import customs declaration has an inverse relationship with the number of import declarations, which means that the shorter the import lead time, the more import declaration increases. Research Limitations/Implications - With limited data accessibility to the government's custom-sclearing procedures, only the import lead time for customs clearance were adopted as independent variables. This paper, however, successfully found that the Single Window system contributed to trade facilitation. Originality/value - This study found that the time-saving Single Window system of Korea Customs enables itself to manage an exponentially-increasing trade volume by creating a trade-facilitating environment for customs personnel and traders, which may be a unique implication found through quantitative methodology.

An Analysis on Thermal Performance and Economic of Heat Recovery Ventilation System Integrated with Window (창호통합형 배열회수 환기시스템의 열성능 및 경제성 평가)

  • Sung, Uk-Joo;Cho, Soo;Song, Kyoo-Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.8
    • /
    • pp.646-655
    • /
    • 2012
  • This study is intended to analyze the thermal performance and evaluate the applicability about non-duct type heat recovery ventilation system integrated with window. Eventually, economic analysis of the system is conducted according to building energy saving ratio of it. As results of the thermal performance, the U-factor of the window conducted on the basis of KS F 2278 appears to $1.8W/m^2K$, and the effective heat exchange efficiency of the ventilator conducted on the basis of KS B 6879 appears 49.95% for cooling, 66.89% for heating. In the applicability evaluated by TRNSYS 16, the caes of applying the heat recovery ventilator integrated with window is found to reduce the cooling or heating load by 2.9% or 13.5% than the non-ventilator case. The results of economic analysis taking a side of consumer is verified as the payback is 3 years, and the accumulated earning is 1,408,133 won in terms of '600,000 won/unit' for initial cost, 10 years for useful life of the system.

Analysis of Window Thermal Performance according to Guidelines on the Balcony Expansion Costs (발코니 확장비용 가이드라인에 따른 창호 열성능 분석)

  • Choi, Gyoung-Seok;Kang, Jae-Sik;Lee, Seung-Eon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.863-868
    • /
    • 2008
  • In accordance with the guidelines on the balcony structure changes in December 2005, most of tenants were moving into apartment housing, expand the balcony, but some large deviation between the price construction costs set of cases, due to overuse and the cause of the dispute, and the housing law amended in 2007 due to price cap system is implemented, the cost of expansion the balcony overdose pointed out that there is set to boost the sale price has been raised. These issues in order to improve the government in January 2008, the "Note costs by the balcony expansion" suggested guidelines to protect the rights of tenants and wants to promote the settlement of the sale price cap system. This study calculated the "Note costs by the balcony expansion" window system based on double or single, high performance insulation window system of the quantitative performance analysis of each type window that purpose.

  • PDF