• Title/Summary/Keyword: window operation

Search Result 329, Processing Time 0.029 seconds

A Study for Solving Multi-Depot Dial-a-Ride Problem Considering Soft Time Window (다수차고지와 예약시간 위반을 고려한 교통약자 차량 서비스에 대한 연구)

  • Kim, Taehyeong;Park, Bum-Jin;Kang, Weon-Eui
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.11 no.5
    • /
    • pp.70-77
    • /
    • 2012
  • Dial-a-ride is the most widely available transit service for disabled persons or seniors in the United States and Europe. This paper studies a static dial-a-ride problem considering multiple depots, heterogeneous vehicles, and soft time windows. In this paper, we apply a heuristic based on clustering first-routing second(HCR) to a real-world large dial-a-ride problem from Maryland Transit Administration(MTA). MTA's real operation is compared with the results of developed heuristic for 24 cases. The objective function of the proposed model is to minimize the total cost composed of the service provider's cost and the customers' inconvenience cost. For the comparison, the objective function values of HCR do not include waiting cost, delay cost, and excess ride cost. The objective function values from HCR are better than those from MTA's operation for all cases. This result shows that our heuristic method can make the real operation better and more efficient.

A Study on Operation Rate and Output of Wave Power Generator by Waves Condition (파랑 조건에 따른 파력발전장치의 가동률과 발전량 산정에 대한 연구)

  • Ryu, Hwang-Jin;Hong, Key-Yong;Shin, Seung-Ho;Kim, Sang-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.615-619
    • /
    • 2009
  • This paper is investigated to variation of wave power generation operation rate, operating capacity and output with the wave conditions represented by wave height-period window. By the use of the long-term wave data from 1979 to 2002 which is provided by Korea Ocean Research & Development Institute(KORDI), we calculated the monthly variation of significant wave height(Hs), zero-up crossing period(Tz) and distribution of wave appearance rate. And using the same wave data, it was charted the Hs-Tz and wave-energy scatter diagrams.

  • PDF

Hydrothermal Synthesis of Fe Based MOFs with Energy Economy Approach

  • Israr, Farrukh;Kim, Duk Kyung;Kim, Yeongmin;Oh, Seung Jin;Ng, Kim Choon;Chun, Wongee
    • Journal of Energy Engineering
    • /
    • v.24 no.2
    • /
    • pp.55-58
    • /
    • 2015
  • The mesoporous metal organic framework structure Fe-BTC was successfully synthesized by hydrothermal process with noticeable yield. The synthesis operation was conducted at intermediate temperature and for shortened operation time as compared to conventional procedures. This process approach with reduced operating temperature and shortened operation time may open an opportunity window towards process economy with reduction in energy consumption. A simple mathematical approach of diffraction indexing using X-ray diffraction patterns of synthesized powder was employed to confirm its crystalline nature and to investigate its high temperature stability. The crystallite size was calculated by using Debye-Scherrer equation.

A War-time Engineering Equipment's Assignment and Operation Model (전시 공병장비 할당 및 운용 모형)

  • Jae-Hyeong Lee;Moon-Gul Lee
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.46 no.4
    • /
    • pp.294-303
    • /
    • 2023
  • During wartime, the operation of engineering equipment plays a pivotal role in bolstering the combat prowess of military units. To fully harness this combat potential, it is imperative to provide efficient support precisely when and where it is needed most. While previous research has predominantly focused on optimizing equipment combinations to expedite individual mission performance, our model considers routing challenges encompassing multiple missions and temporal constraints. We implement a comprehensive analysis of potential wartime missions and developed a routing model for the operation of engineering equipment that takes into account multiple missions and their respective time windows of required start and completion time. Our approach focused on two primary objectives: maximizing overall capability and minimizing mission duration, all while adhering to a diverse set of constraints, including mission requirements, equipment availability, geographical locations, and time constraints.

Memory Characteristics of Al2O3/La2O3/SiO2 Multi-Layer Structures for Charge Trap Flash Devices (전하 포획 플래시 소자를 위한 Al2O3/La2O3/SiO2 다층 박막 구조의 메모리 특성)

  • Cha, Seung-Yong;Kim, Hyo-June;Choi, Doo-Jin
    • Korean Journal of Materials Research
    • /
    • v.19 no.9
    • /
    • pp.462-467
    • /
    • 2009
  • The Charge Trap Flash (CTF) memory device is a replacement candidate for the NAND Flash device. In this study, Pt/$Al_2O_3/La_2O_3/SiO_2$/Si multilayer structures with lanthanum oxide charge trap layers were fabricated for nonvolatile memory device applications. Aluminum oxide films were used as blocking oxides for low power consumption in program/erase operations and reduced charge transports through blocking oxide layers. The thicknesses of $SiO_2$ were from 30 $\AA$ to 50 $\AA$. From the C-V measurement, the largest memory window of 1.3V was obtained in the 40 $\AA$ tunnel oxide specimen, and the 50 $\AA$ tunnel oxide specimen showed the smallest memory window. In the cycling test for reliability, the 30 $\AA$ tunnel oxide sample showed an abrupt memory window reduction due to a high electric field of 9$\sim$10MV/cm through the tunnel oxide while the other samples showed less than a 10% loss of memory window for $10^4$ cycles of program/erase operation. The I-V measurement data of the capacitor structures indicated leakage current values in the order of $10^{-4}A/cm^2$ at 1V. These values are small enough to be used in nonvolatile memory devices, and the sample with tunnel oxide formed at $850^{\circ}C$ showed superior memory characteristics compared to the sample with $750^{\circ}C$ tunnel oxide due to higher concentration of trap sites at the interface region originating from the rough interface.

A Study on Application SCTP SNOOP for Improving a Data Transmission in Wireless Network (무선망에서 데이터 전송 향상을 위한 SCTP SNOOP 적용 연구)

  • Hwang, Eun-Ah;Seong, Bok-Sob;Kim, Jeong-Ho
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2007.11a
    • /
    • pp.126-129
    • /
    • 2007
  • Recently the use of wireless network increases according to it solves the hand-off and with path loss, pading, noise etc of wireless network the research for transmission error improvement is developed. TCP and SCTP of standard where it guarantees the reliability of wire network apply in wireless network the congestion control, flow control mechanism used it decreases the efficiency of data transfer throughputs. In this paper, It mixes SCTP and SNOOP for SCTP apply on wireless network, to improve BS(Basic Station) operation processes when the transmission error occurs in wireless network. BS send ZWP(Zero Window Probe) to MN(Mobile Node) when the transmission error occurs so, check path and status and update RWND and error status checked. It selects the new path, send ZWA(Zero Window Advertisement) to FH(Fixed Host) and the prevents call to congestion control or flow control and it does to make wait status standing. Continuously of data transfer after the connection of wireless network is stabilized, it make increase about 10% the transmission throughput of data.

  • PDF

A Study on Performance Improvement of FIR Digital Filter using Modified Window Function (변형된 창함수를 이용한 FIR 디지털 필터의 성능 향상에 관한 연구)

  • Kim, Nam-Ho;Ku, Bon-Seok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.758-761
    • /
    • 2007
  • Digital signal processing technique is applied in wide fields such as speech processing, image processing and spectrum analysis. Therefore, in order to do frequency selective operation digital filter is used in stead of analog filter and sharp filter characteristics can be implemented. Since finite impulse response (FIR) digital filter as nonrecursive type represents linear phase response characteristics and is always stable and is used in fields regarding wave information importantly such as data transmission. And due to frequency characteristics, in order to remove the Gibbs phenomenon generating around a discontinuous point, filter is designed through window function method. Therefore, in this paper to improve performance of FIR digital filter, a modified window function was applied. And the proposed method was compared with conventional methods using peak side-lobe and transition properties in simulations.

  • PDF

Adaptive Shot Change Detection Technique Using Histogram Mean within Extension Sliding Window and Its Implementation on Portable Multimedia Player (확장 참조 구간의 히스토그램 평균값을 이용한 적응적인 장면 전환 검출 기법과 휴대용 멀티미디어 재생기에서의 구현)

  • Kim, Won-Hee;Cho, Gyeong-Yeon;Kim, Jong-Nam
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.4
    • /
    • pp.23-33
    • /
    • 2009
  • A shot change detection technique is an important technique for effective management of video data, thus it requires an adaptive algorithm for various video sequences to detect an accurate shot change frames. In this paper, we propose an adaptive shot change detection algorithm using histogram mean of frames within extension sliding window. Our algorithm calculates a frame feature value using histogram and defines an adaptive threshold using an average of histogram mean of frames within the extension sliding window and determines a shot change by comparing the feature value and the threshold. We obtained better detection rate than the conventional methods maximally by 15% in the experiment with the same test sequence. We verified real-time operation of shot change detection in the hardware platform with low performance by implementing it on TVUS HM-900 PLUS model of Homecast. The Proposed algorithm can be useful in the hardware platform such as portable multimedia player(PMP) or cellular phone with low CPU performance.

Clinical Study of the Treatment of Chronic Empyema with Open Window Thoracostomy: 10 Years Experience (개방식 배농술을 이용한 만성 농흉 치료의 임상적 고찰 - 10년 경험 -)

  • Kim, Young-Kyu;Kim, Yeong-Dae
    • Journal of Chest Surgery
    • /
    • v.40 no.11
    • /
    • pp.765-769
    • /
    • 2007
  • Background: The curative treatment of choice for empyema is decortication of the pleura. The risks of this treatment however are increased for the patient with reduced pulmonary function, complicated calcification or septic shock. In the past, open window thoracostomy was a final stage treatment for chronic empyema. Relatively safe treatment of empyema could be achieved in difficult cases with a closure of the open window after open drainage and use of a myocutaneous flap (one stage or staged). Material and Method: A retrospective study of the cause, progression and final outcome of empyema patients who received open window thoracostomy was performed. 21 patients were followed from 1995 to 2004 in the department of Thoracic and Cardiovascular Surgery in the College of Medicine, Pusan National University. Result: The average age of the patients was $57.5{\pm}15.5$ years (range $25{\sim}78$ years), of whom 16 (76.2%) were men and five (23.8%) were women. Pulmonary function test results showed an average FEV1 of $1.58{\pm}0.49 L$. The type of empyema was tuberculous empyema in 13 cases (61.9%), aspergillosis in three cases (14.3%), parapneumonic empyema in three cases (14.3%) and post-resectional empyema in two cases (10%). Bronchopulmonary fistula was seen in 14 cases. Eight cases were complicated by severe calcification of the pleura. For the four cases of bronchopulmonary fistula, the patients' serratus anterior muscle was covered in their first operation. The average number of ribs resected was $4{\pm}1$. Closure of the open window thoracostomy was performed in 12 cases. The average time to closure after open drainage was $10.22{\pm}3.11$ months and the average defect of the empyemal cavity before the final operation was $330{\pm}110 cc$. Among the 12 cases, there were two cases of spontaneous closure. In two cases closure was only achieved by using the reserved skin fold during the first surgery. Of the remaining eight cases, in seven we used the myocutaneous flap (four cases of lattisimus dorsi muscle and three cases of pectoralis major muscle), and in one case we used soft tissue. As regards complications of the closure, tissue necrosis occurred in one case, which led to failed closure, and there was one case of abdominal hernia in the rectus abdominis muscle flap. One patient died within 30 days of the surgery and one patient died of metastatic cancer. Conclusion: A staged operation with a final closure using open window thoracostomy, which consists of open drainage, transposition of the muscle and a myocutaneous flap, can be a safe and effective option for the chronic empyema patient who is difficult to cure with traditional surgical methods.

The Development of an Operating System for Load-following Real-time Transformer Loss Minimization and Economic Analyses on its' Test Operation (부하 추종형 실시간 변압기 손실감소운전시스템 개발과 시범운영 경제성 분석)

  • Lee, Ok-Bae;Ahn, Jae-Kyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.797-803
    • /
    • 2012
  • In this paper, for minimizing the real-time operating load losses of the power transformer, a SCADA optimum operating system was developed, and the economic analyses on the test operation were performed. Transformer loss DB which reflects the economic integration operation criteria was constructed by referring the transformer manufacturer's loss data(iron loss, copper loss). Based on the loss DB, each substation transformer real-time loss was calculated according to the size of the transformer loads, and if integration or separation transformer operating conditions minimizing the loss are met, then a window pops-up and the dispatcher performs the substation equipments operation according to the procedure provided by this system. With the existing SCADA main program, the relation database of the substation facilities and integration/separation operation algorithm were developed and applied to Auto MTR Processor and pconn Processor Task module. Seven stations test data for seven months were analyzed for the economic analyses, and the results showed that Cost-Benefit ratio was 2.64, and IRR(Internal Rate of Return), 36%, which asserted the economic justification of the proposed system.