Numerical analysis on the thermal characteristics of the exhaust triple-glazed airflow window (배기식 3중 집열창의 열적 특성에 대한 수치해석)

  • 김무현;오창용
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.1
    • /
    • pp.40-49
    • /
    • 2000
  • The flow and heat transfer characteristics of the exhaust airflow window system were studied numerically by a finite volume method. Attention was paid to see the decrease in indoor cooling load. The exhaust air flow rate, solar energy power and aspect ratio of window were considered as main variables. From the result of the comparison between the exhaust airflow window and the enclosed window, the indoor heat gain was reduced remarkably by 76%. It is also suggested that in the design of the exhaust airflow window optimum values of aspect ratio, H/W and exhaust air flow rate, Re were about 0.05 and 600, respectively.

  • PDF

An Optimized Design and Simulation Analysis of Natural Ventilation Window System classified by Apartment type (주거용 건물 유형별 자연환기시스템의 최적 설계 및 해석)

  • Choi, Gyeong-Seok;Jeong, Young-Sun;Kang, Jae-Sik;Lee, Seung-Eon;Jeong, Yeong-Yong
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.685-688
    • /
    • 2009
  • On account of Indoor Air Quality(IAQ) deterioration by reason of high insulation and air tightness for energy saving, absence of energy efficiency ventilation system development that can be domestic existing window system, the cost increase and the energy addition loss by mechanical ventilation for IAQ improvement, the ventilation obligation making design standard was prepared by a social and technical background and the necessity. In this study, an optimized design and simulation Analysis of natural ventilation window system classified by Apartment type was evaluated by CFD Computational analysis.

  • PDF

Thermal-Hydraulic, Structural Analysis and Design of Liquid Metal Target System (액체금속 표적 시스템의 열적, 구조적 건전성 평가 및 설계)

  • 이용석;정창현
    • Journal of Energy Engineering
    • /
    • v.10 no.3
    • /
    • pp.294-298
    • /
    • 2001
  • A research for transmutation reactor is in progress to transmute high radioactive isotopes into low radioactive ones. In this study, thermal-hydraulic and structural analysis was performed to design liquid metal target system that would be used in subcritical transmutation reactor. Diffuse plate installation was considered to enhance cooling of window. And thermal-structural analysis of window was performed varying window thickness, beam power, and coolant flow rate to determine target system design valuers. It is ensured that maximum window temperature and stress would be acceptable in the design condition.

  • PDF

Sample selection approach using moving window for acoustic analysis of pathological sustained vowels according to signal typing

  • Lee, Ji-Yeoun
    • Phonetics and Speech Sciences
    • /
    • v.3 no.3
    • /
    • pp.99-108
    • /
    • 2011
  • The perturbation parameters like jitter, shimmer, and signal-to-noise ratio (SNR) are largely estimated in the particular segment from the subjective or whole portion of the given pathological voice signal although there are many possible regions to be able to analyze the voice signals. In this paper, the pathological voice signals were classified as type 1, 2, 3, or 4 according to narrow band spectrogram and the value differences of the perturbation parameters extracted in the subjective and entire portion tended to be getting bigger as from type 1 to type 4 signals. Therefore, sample selection method based on moving window to analyze type 2 and 3 signals as well as type 1 signals is proposed. Although type 3 signals cannot be analyzed using the perturbation analysis, the type 3 signals by selecting out the samples in which error count is less than 10 through moving window were analyzed. At present, there is no method to be able to analyze the type 4 signals. Future research will endeavor to determine the best way to evaluate such voices.

  • PDF

The Efficiency Analysis of Firms Having Established a Business Intelligence System Using DEA/Time-Window Analysis (DEA를 이용한 기업의 Business Intelligence 시스템 도입 효율성에 대한 비교 평가 연구)

  • Baek, Seong-Hyun;Park, Kwang-Ho;Kim, Tai-Young
    • Information Systems Review
    • /
    • v.17 no.3
    • /
    • pp.113-133
    • /
    • 2015
  • In this paper, DEA analysis is employed to compare and evaluate the relative efficiency of a business intelligence (BI) system among five industrial groups such as IT and financial services, electricity and electronics, energy and chemistry, automotive and heavy machinery, and food and apparel. Especially, this study has analyzed the improving tendency of relative efficiency of the industrial groups since they adopted the BI System using Time-Window Analysis. The research findings show that the energy and chemical industry group tends to be remarkably more efficient than the other groups and the electrical and electronic industry turns out to gradually improve their efficiency since the adoption of the BI system.

Analysis of Various Window Effect for SAR image Recovery (SAR image 복구를 위한 Window 적용 효과 연구)

  • Kim, Hyunguk;Koh, Jinhwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.12
    • /
    • pp.46-54
    • /
    • 2015
  • SAR is a Radar to obtain the video information using a radio wave. Platform emit the radio wave, depending backscattered waves returned from the target object the signal to the distance, to create a topographical map is recorded in two-dimensional image. In this paper, through a simulation to apply a variety of window in the SAR image processing for SAR image recovery is to study the application effect of the window, as a result, at the side of the signal of the SNR, Flattop window to improve the best performance it was confirmed to show.

Wigner-Ville Distribution Applying the Rotating Window and Its Characteristics (회전 창문함수를 적용한 위그너-빌 분포함수와 그 특성)

  • 박연규;김양한
    • Journal of KSNVE
    • /
    • v.7 no.5
    • /
    • pp.747-756
    • /
    • 1997
  • Wigner-Ville distribution which is a time-frequency analysis has a fatal drawback, when the signal has multiple components. This is the cross-talk and often causes a neagative value in the distribution. Wingner-Ville distriution is an expression of power, therefore the cross-talk must be avoided. Smoothing the Wigner-Ville distribution by convoluting it with a window, is most commonly used to reduce the cross-talk. There can be infinite number of distributions depending on the windows. But, the smoothing reduces resolution in time-frequency plane; this motives to design a more effective window in reducing cross-talk while remaining resolution. The domain in which the cross-talk and legitimate components can be easily distinguished, is the ambiguity function. In the ambiguity function domain, the legitimate components appear as linear lines passing through the orgine. But, the cross-talk is widely distributes in the ambiguity function plane. Based on the relative distributions of cross-talk and legitimate components, rotating window can be designed to minimize cross-talk. Applying the rotating window to the ambiguity function corresponds to smoothing the Wigner-Ville distribution. Therefore, the effects of rotating window is estimated in terms of the bias error due to smooting the Wigner-Ville distribution. By applying the rotating window, not only the Wigner-Ville distribution but also its properties are changed. The properties of the new distribution are checked, in order to complete analyzing the rotating window.

  • PDF

The Effect of Design Originality in Fashion Window Display on the Attitudes Toward Fashion Brands and the Purchasing Intention (패션 윈도우 디스플레이의 디자인 독창성이 브랜드 태도와 구매의도에 미치는 영향)

  • Choi, Eun Young
    • Journal of the Korean Society of Costume
    • /
    • v.63 no.1
    • /
    • pp.120-134
    • /
    • 2013
  • This study was intended to investigate the designs that are displayed on fashion windows, specifically the originality of its designs, from here on noted as "design originality", and the effects it has on the attitudes of consumers toward fashion brands and their purchasing intentions depending on their level of clothing involvement. For the purpose of this study, 10 pictures of creative fashion window display designs from Fifth Avenue in New York were selected and they were shown to 200 college students in Busan in order to collect data for the analysis. The results are as follows: 1) Factor analysis identified four factors that impacted how consumers judged design originality, uniqueness, humor, favorable impression and advanced design. 2) The four factors of design originality in fashion window display significantly affected consumer's evaluation on usefulness of information provided by the window display, attitudes toward fashion brands and purchase intention. 3) The respondents were separated into two groups depending on their level of clothing involvement. Consumers with high level of clothing involvement showed that they were influenced more by the design originality when making purchase decisions. Especially, the uniqueness factor and advanced design factor had more effect on brand attitudes and purchase intention in high level of clothing involvement group. The results revealed that creative fashion window display design are important marketing strategic tools that affect attitudes of consumers toward brands and their purchasing intentions.

Characterization of Photoelectron Behavior of Working Electrodes with the Titanium Dioxide Window Layer in Dye-sensitized Solar Cells

  • Gong, Jaeseok;Choi, Yoonsoo;Lim, Yeongjin;Choi, Hyonkwang;Jeon, Minhyon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.346.1-346.1
    • /
    • 2014
  • Porous nano crystalline $TiO_2$ is currently used as a working electrode in a dye-sensitized solar cell (DSSC). The conventional working electrode is comprised of absorption layer (particle size:~20 nm) and scattering layer (particle size:~300 nm). We inserted window layer with 10 nm particle size in order to increase transmittance and specific surface area of $TiO_2$. The electrochemical impedance spectroscope analysis was conducted to analysis characterization of the electronic behavior. The Bode phase plot and Nyquist plot were interpreted to confirm the internal resistance caused by the insertion of window layer and carrier lifetime. The photocurrent that occurred in working electrode, which is caused by rise in specific surface area, increased. Accordingly, it was found that insertion of window layer in the working electrode lead to not only effectively transmitting the light, but also increasing of specific surface area. Therefore, it was concluded that insertion of window layer contributes to high conversion efficiency of DSSCs.

  • PDF

A Flow Channel Design on IR Window Cooling Device (적외선 윈도우 냉각장치 유로 설계)

  • Park, Youn-Jung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.6
    • /
    • pp.559-566
    • /
    • 2011
  • This paper presents the flow passage design for a window cooling device, which have a conical poppet valve and an emissive orifice. Computational flow analysis and experiment are conducted according to the poppet strokes. The results show satisfactory flow characteristics that pressure is reduced enough to endure material strength and the flow does not choked inside window. The correction factor of discharge coefficients is found between 2-dimensional analysis and experiments, which is applied to control coolant flow rates of the window cooling device.