• 제목/요약/키워드: winding change

검색결과 134건 처리시간 0.026초

부하변화에 대한 변압기 진동 분석 (Transformer Vibration Analysis for a variation of Load)

  • 강창구;곽희로;정찬수;조국희;권혁승
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1993년도 추계학술발표회논문집
    • /
    • pp.103-106
    • /
    • 1993
  • This paper describes the modeling of winding vibration for a variation of load and temperature. The structural changes in transformer windings due to heat cause the change of vibration patterns. The vibration signals were detected by the accelerometer on the transformer windings. The real values were compared with estimated value using least-squares method, vibration model was cstablished and with this model, error compared with original signal was less than -50[db]. These results could be applied to diagnosis of incipient failures of the power transformers.

  • PDF

집전전압 향상을 위한 가변탭 단권변압기 검토 (Evaluation of the variable TAB Autotransformer for ascending collecting Voltage)

  • 이장무;한문섭;이한민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1426-1430
    • /
    • 2009
  • AC AT feeding method consists return circuits of electric train inserting in parallel between trolly line and feeding line and connecting neutral line to rail and FPW. Due to increasing electric load at feeding system, collecting voltage of train and end voltage are going down. So to increase voltage between trolly line and rail, the usefulness of new autotransformer are considered which variation of short impedance and change of line voltage is simulated with modified winding ratio of autotransformer from 1:1 to variable tab.

  • PDF

능력가변을 위한 단상유도전동기의 극수변환 방법에 관한 연구 (A Study of the Pole Change Method of the Single-Phase Induction Motor for Capability Variation)

  • 김규헌;정태욱
    • 한국산업융합학회 논문집
    • /
    • 제23권3호
    • /
    • pp.499-505
    • /
    • 2020
  • Capacitor-run single-phase induction motor is cheaper than motors that use permanent magnets and is widely used in home appliances and industries based on relatively high durability and productivity. It can also be operated by line. However speed cannot be controlled because the line frequency is free. In this paper we dealt pole change method one of the method controlling speed of capacitor-run single-phase induction motor. The conventional pole change method is difficult to improve the power and efficiency of the motor because the composition of the pole change device is complex and do not have enough area of the windings because of windings not used according to the driving conditions. In this paper, we proposed the pole change method that is used main windings and auxiliary windings at 4 poles operation and used auxiliary windings as compensation windings at 2 poles operation. The proposed method was verified through finite element analysis.

소형 Slot less PMSM의 coil 배치에 따른 최적 설계 및 열 내구성 분석 (A Study on Optimal Design According to Change of Coil Distribution in Slot Less Type Permanent Magnet Synchronous Motor)

  • 김용태;고덕화;김규화;백성민;김규탁
    • 전기학회논문지
    • /
    • 제66권1호
    • /
    • pp.27-32
    • /
    • 2017
  • In this paper, slot less type high-speed and compact motor was designed. it was selected through change of stator coil distribution for the optimal performance of the motor. In this paper, designed motor was expected to be very vulnerable to heat dissipation in a compact motor. Therefore, to ensure reliability in the design result, winding and permanent magnet damage caused by the losses of motor was analyzed by thermal analysis and demagnetization analysis. Using the result, whether motor burnout was confirmed by motor performance degradation and insulation breakdown.

폴리머 피뢰기의 모듈 설계 및 성능에 관한 연구 (A Study on Module Design and Performance of Polymer Arrester)

  • 조한구;천종욱;강영길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마연구회
    • /
    • pp.108-111
    • /
    • 2003
  • The main objective of this paper is to module design and pressure relief test a new type of polymer gapless surge arrester for power distribution line. Metal oxide surge arrester for most electric power system applications, power distribution line and electric train are now being used extensively to protect overvoltage due to lightning. Surge arresters with porcelain housing must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of gapless elements in a surge arrester occurs due to flashover, fault short current flows through the arrester and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock, pressure rise, etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion.

  • PDF

Two-Drum Winder 권취 공정 시스템에서의 적용 PID 제어기를 이용한 장력제어 (Tension Control Using Adaptive PID Controller in the Two-Drum Winder Web Transport System)

  • 최승규;이동빈;임화영
    • 제어로봇시스템학회논문지
    • /
    • 제6권9호
    • /
    • pp.813-821
    • /
    • 2000
  • In this paper, we developed modeling of tension and speed dynamics for a two-drum winder in a three span continuous web transport system which had not been previously. Dynamic modeling of the time-varying nonlinear system was derived by considering the effect of the radii and mass moment of inertia in the unwinder and the two-drum winder through winding up the web. After linearizing it, we designed with a variable-gain a PID controller for tension control and a PI controller for speed. Simulation is carried out with the variation of radii and moment of inertia at high speed for the proposed tension control system with the two-drum winder and the variavle-gain a PID controller. Results show good performance of tension control during the speed change speed at a start-up and stop.

  • PDF

대형의료기기의 회로 단락시 전류흐름에 대한 시뮬레이션 연구 (A study on simulation to current flow by short circuit of medical machine)

  • 최도순
    • 한국정보전자통신기술학회논문지
    • /
    • 제5권4호
    • /
    • pp.211-215
    • /
    • 2012
  • 대형의료기기는 환자 진단과 치료 행위에 있어서 매우 중요한 기기이다. 이런 대형의료기기를 사용하여 환자를 진단 또는 치료할 때 의료기기의 회로 내에서 갑작스런 전류의 변화는 회로의 단락 등 매우 심각한 문제를 일으킨다. 특히 회로 내에서 전류변환기에 큰 부하가 걸리게 한다. 이것으로 인해 변환기는 포화에 이르게 되는데 이것은 철심코일 인턱터의 magnetic curve에 기인한다. 이와 같이 변환기가 saturate에 이르게 되면 1차 측과 2차 측의 변환 비율이 깨지게 되고 회로가 단락되는 문제가 발생하게 된다. 이 논문 에서는 대형의료기기에 사용되는 current 변환기의 입력 측에 갑작스런 큰 전류 변화가 발생 했을 때 일어나는 그에 따른 포화 상태와 그의 2차 측 전류의 변화를 simulation 해본다.

자기회로의 위상학적 상사성을 이용한 전류제한기 구조에 관한 연구 (The Research for a Structure of Current Limiter using a Phasic Similitude of Magnetic Circuit)

  • 지근양;민경일;이수원;장봉환;문영현
    • 전기학회논문지
    • /
    • 제58권11호
    • /
    • pp.2128-2135
    • /
    • 2009
  • In this paper, current limiter using a magnetic switching which is based on magnetic flux change in the case of fault is proposed. This current limiter consists of iron-core and three parts of coils. One is the primary coil connected to the power system. Another is the secondary coil wound to the opposite direction of the primary coil's winding. The other is the secondary of the secondary coil which is a movable copper plate winding and located below the secondary coil. In the normal state, the magnetic flux produced in the primary and secondary coils flows to the opposite directions each other and becomes to be canceled out. Therefore the voltages induced between the coils are zero. In the case of a fault, at the moment of a fault occurrence recognition, the switch connected to a secondary coil is opened and the secondary of the secondary coil is pulled out to the outside of the iron-core. Then, magnetic flux becomes to flow through the iron-core. Accordingly, the voltage is induced between the both ends of the primary coil and makes the current reduced. Therefore it is possible to cut off the circuit breaker easily with the proposed current limiter. This paper analyzes the current limiting effects and the detailed results are given.

시뮬레이션을 통한 자기결합을 이용한 초전도 한류기의 전류제한 특성 분석 (An Analysis on Current Limiting characteristics of an SFCL using Magnetic Coupling between Two Coils through Computer Simulation)

  • 김진석;안재민;임성훈;문종필;김재철;김철환;현옥배
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권1호
    • /
    • pp.42-47
    • /
    • 2008
  • In this paper, the fault current limiting characteristics for the superconducting fault current limiter(SFCL) using magnetic coupling between two coils were investigated. The SFCL consists of a high-$T_c$ superconducting(HTSC) element and two coils. This SFCL has different characteristics that depend on the connection form, the winding direction and the inductance ratio of two coils. The impedance and the operational current of the SFCL can be adjusted higher or lower than the resistance and the critical current of HTSC element. Therefore, the SFCL can change the amplitude of the limited fault current. To confirm it, the HTSC element was modeled and the fault current limiting characteristics of the SFCL were analysed through computer simulation. It was obtained from the analysis that the connection form and the winding direction of two coils of the SFCL were the important design parameters.

Type II 고압수소저장용기의 충전과 방출에 의한 권선 거동 관찰의 기계적 방법에 관한 연구 (A Study on the Mechanical Method of Observing Winding Behavior by Charging and Discharging of Type II High Pressure Hydrogen Storage Tank)

  • 김승환;한진목;이성희;정영관
    • 한국수소및신에너지학회논문집
    • /
    • 제33권2호
    • /
    • pp.158-163
    • /
    • 2022
  • The test method on the Type II high-pressure hydrogen storage tanks made of the metal wire hoop winding is a complex and high risk. Also closeup on the tank being test is difficult. In this study, we studied a mechanical test method for a high-pressure hydrogen tanks. This method must be simple, risk-free and possible to observe the change in microscopic behavior of a metal wire on a liner. As the results, it was possible to observe the microscopic behavior on the metal wire by the mechanical test method. Also, a simple and risk-free test was possible compared to the conventional test method for high pressure hydrogen tanks.