• 제목/요약/키워드: wind turbine generator

검색결과 504건 처리시간 0.03초

도심형 풍력 발전기용 방사 자속형 영구자석 동기 발전기의 출력특성에 관한 연구 (A Study on Output Characteristic Design of Radial Field Permanent Magnet Synchronous Generator for Urban Wind Turbine)

  • 배병덕;윤승주;정태욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1001-1002
    • /
    • 2011
  • Recently, issues regarding environment and the diversification of dependence in oil are watched with keen interest. Wind power attracts most interest because of its high-energy efficiency with eco friendly functions. In this paper, deal with design of radial field permanent magnet synchronous generator for a urban wind power system. Analyzed the RFPM generator by electromagnetic, and designed wind power generator with this. The output characteristic of machine and all of process is analyzed by 2D FEA due to geometrical structures of RFPM machine.

  • PDF

Maximum Power Point Tracking Control Scheme for Grid Connected Variable Speed Wind Driven Self-Excited Induction Generator

  • El-Sousy Fayez F. M.;Orabi Mohamed;Godah Hatem
    • Journal of Power Electronics
    • /
    • 제6권1호
    • /
    • pp.52-66
    • /
    • 2006
  • This paper proposes a wind energy conversion system connected to a grid using a self-excited induction generator (SEIG) based on the maximum power point tracking (MPPT) control scheme. The induction generator (IG) is controlled by the MPPT below the base speed and the maximum energy can be captured from the wind turbine. Therefore, the stator currents of the IG are optimally controlled using the indirect field orientation control (IFOC) according to the generator speed in order to maximize the generated power from the wind turbine. The SEIG feeds a (CRPWM) converter which regulates the DC-link voltage at a constant value where the speed of the IG is varied. Based on the IG d-q axes dynamic model in the synchronous reference frame at field orientation, high-performance synchronous current controllers with satisfactory performance are designed and analyzed. Utilizing these current controllers and IFOC, a fast dynamic response and low current harmonic distortion are attained. The regulated DC-link voltage feeds a grid connected CRPWM inverter. By using the virtual flux orientation control and the synchronous frame current regulators for the grid connected CRPWM inverter, a fast current response, low harmonic distortion and unity power factor are achieved. The complete system has been simulated with different wind velocities. The simulation results are presented to illustrate the effectiveness of the proposed MPPT control scheme for a wind energy system. In the simulation results, the d-q axes current controllers and DC-link voltage controller give prominent dynamic response in command tracking and load regulation characteristics.

이중 고정자 구조의 소형풍력터빈용 AFPM 발전기의 코깅토크 저감에 관한 연구 (Study on Cogging Torque Reduction for Small Wind Turbine AFPM Generator of Double Stator Structure)

  • 정태욱;배병덕
    • 조명전기설비학회논문지
    • /
    • 제26권2호
    • /
    • pp.71-77
    • /
    • 2012
  • The cogging torque is important to the cut-in wind speed. And, it causes the acoustic noise and the vibration on the machine. This paper presents a 3D FEA(Finite Element Analysis) to evaluate the effect of magnet skew and stator displacement on cogging torque reduction, for double core AFPM(Axial Flux Permanent Magnet) generator. As a result, the magnet skew and the stator side displacement are proved excellent techniques to reduce the cogging torque.

750kw급 직접 구동형 풍력 발전기의 제어 시스템 개발 (Control System Development of 750kW Direct Drive Wind Turbine Generator)

  • 김대현;황진수;이승훈;장성태;류지윤
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.55-58
    • /
    • 2005
  • 풍력발전기에 있어서 보호 및 제어 시스템은 그 효율, 성능, 안전 및 수명까지도 영향을 미칠 수 있는 중요한 구성요소이다 따라서 제어 시스템은 풍력발전기의 최대 효율 및 가동률을 확보하여야 하며 풍력발전기에 문제가 발생할 경우 즉시 가동을 정지할 수 있도록 안전성을 확보할 수 있도록 설계되어야 한다. 본 연구에서는 "750kw급 Gearless형 풍력발전시스템 개발" 과제의 일환으로 수행되었던 풍력발전기용 제어시스템의 설계 및 제작 과정과 상용제품으로서의 본 제어 시스템을 소개하고자 한다.

  • PDF

신재생 에너지원 기반의 마이크로그리드 최적운영 방안 (Optimal Operation Scheme of MicroGrid System based on Renewable Energy Resources)

  • 이상봉;김규호;이상근
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1467-1472
    • /
    • 2011
  • This paper presents an optimal operation of microgrid systems and considering a tie-lines capacities that concerned each grid. The microgrid system consists of a wind turbine, a diesel generator, and a fuel cell. An one day load profile and wind resource for wind turbine generator were used for the study. For the grid interconnection, tie-line capacities were applied as constraints. The capacity constraints of tie-lines in production cost analysis are very important issues in the operation and planning of microgrid. In optimization, the Harmony Search (HS) algorithm is used for solving the problem of microgrid system operation which a various generation resources are available to meet the customer load demand with minimum operating cost. The application of HS algorithm to optimal operation of microgrid proves its effectiveness to determine optimally the generating resources without any differences of load mismatch.

풍력발전기 너셀 내부 환경특성을 고려한 화재 조기감지방법 연구 (A Study on the Early Fire Detection based on Environmental Characteristics inside the Nacelle of Wind Turbine Generator System)

  • 김다희;임종환
    • 한국정밀공학회지
    • /
    • 제31권9호
    • /
    • pp.847-854
    • /
    • 2014
  • The paper presented a method of early fire detection based on the environmental characteristics inside the nacelle of wind turbine generator system(WTGS). The rising rates of the temperature and smoke density were used as the parameters for early fire detection. By considering the characteristics of temperature and smoke density of a nacelle, this method is very reliable and can minimize the possibility of a malfunction of fire detection. The performance of the method was tested through sets of experiments by using nacelle simulator.

Reactive Current Assignment and Control for DFIG Based Wind Turbines during Grid Voltage Sag and Swell Conditions

  • Xu, Hailiang;Ma, Xiaojun;Sun, Dan
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.235-245
    • /
    • 2015
  • This paper proposes a reactive current assignment and control strategy for a doubly-fed induction generator (DFIG) based wind-turbine generation system under generic grid voltage sag or swell conditions. The system's active and reactive power constrains during grid faults are investigated with both the grid- and rotor-side convertors (GSC and RSC) maximum ampere limits considered. To meet the latest grid codes, especially the low- and high-voltage ride-through (LVRT and HVRT) requirements, an adaptive reactive current control scheme is investigated. In addition, a torque-oscillation suppression technique is designed to reduce the mechanism stress on turbine systems caused by intensive voltage variations. Simulation and experiment studies demonstrate the feasibility and effectiveness of the proposed control scheme to enhance the fault ride-through (FRT) capability of DFIG-based wind turbines during violent changes in grid voltage.

PSCAD/EMTDC를 이용한 풍력발전 시스템 모델 개발 (Development of wind power generator system model using PSCAD/EMTDC)

  • 김영주;박대진;모하마도 하산 알리;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.2000-2001
    • /
    • 2007
  • Wind power generation system based on the PSCAD/EMTD is proposed in this paper for the simulations under the real weather conditions. Real field data of weather condition is interfaced to PSCAD/EMTDC using Fortran program interfaced method. And a new turbine component is developed using characteristic equation of a wind turbine and pitch angle control algorism. The generator output and current supplied into utility can be obtained by the transient analysis using PSCAD/EMTDC.

  • PDF

소형 풍력발전용 AFPM 발전기의 설계와 특성해석 (Characteristics Analysis and Design of AFPM Generator for small Wind Turbine)

  • 이승훈;김철호;공정식;서영택;오철수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.807-809
    • /
    • 2001
  • Permanent-magnet generators have been used for wind turbines for many years. This paper deals with the AFPM(Axial - Flux Permanent Magnet) Generator with a high power-to-weight ratio, dedicated for small wind turbines. The designed and constructed generator as a prototype in this study is a slotless type AFPM Generator with Neodymium-Iron-Boron magnet rotor. Based on that construction, a magnetic circuit analysis of the generator is carried out. Some important equations covering its characteristics and construction are derived and its magnetic and electrical characteristics are investigated.

  • PDF

Power Fluctuation Reduction of Pitch-Regulated MW-Class PMSG based WTG System by Controlling Kinetic Energy

  • Howlader, Abdul Motin;Urasaki, Naomitsu;Yona, Atsushi;Senjyu, Tomonobu;Saber, Ahmed Yousuf
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권2호
    • /
    • pp.116-124
    • /
    • 2012
  • Wind is an abundant source of natural energy which can be utilized to generate power. Wind velocity does not remain constant, and as a result the output power of wind turbine generators (WTGs) fluctuates. To reduce the fluctuation, different approaches are already being proposed, such as energy storage devices, electric double layer capacitors, flywheels, and so on. These methods are effective but require a significant extra cost to installation and maintenance. This paper proposes to reduce output power fluctuation by controlling kinetic energy of a WTG system. A MW-class pitch-regulated permanent magnet synchronous generator (PMSG) is introduced to apply a power fluctuation reducing method. The major advantage of this proposed method is that, an additional energy storage system is not required to control the power fluctuation. Additionally, the proposed method can mitigate shaft stress of a WTG system. Which is reflected in an enhanced reliability of the wind turbine. Moreover, the proposed method can be changed to the maximum power point tracking (MPPT) control method by adjusting an averaging time. The proposed power smoothing control is compared with the MPPT control method and verified by using the MATLAB SIMULINK environment.