• Title/Summary/Keyword: wind test

Search Result 1,776, Processing Time 0.03 seconds

Experimental Study on Evaluation of Rotational Resistance of Multi-Span Greenhouse Foundations (연동비닐하우스 기초의 회전저항성능 평가에 관한 실험적 연구)

  • Lee, Hyunjee;Shin, Jiuk;Kim, Minsun;Choi, Kisun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.9
    • /
    • pp.5-12
    • /
    • 2018
  • The foundation of the multi-span greenhouse structures is designed with small shallow concrete foundation considering mainly the vertical load. However, recently, due to an abnormal climate such as strong wind, horizontal load and up-lift load over design strength are applied to the foundation, causing safety problems of the greenhouse foundation. In order to reasonably evaluate the safety of greenhouse foundations, rotational and pullout stiffness expressed by the ground-foundation interaction should be evaluated, which also affects the safety of the upper structural members. In this study, three representative basic foundation types were selected by classifying greenhouse standards in Korea according to the shape, and the horizontal loading tests and theoretical calculation were performed for each foundation type. As a result of the comparison and analysis of the test and calculation, it was found that rotational resistance of the foundation is different according to the ratio of the contact area between the foundation and ground when the conditions of the foundation - ground contact surface and the mechanical properties of the ground are the same.

Scaled model tests for improvement and applicability of the transverse smoke control system on tunnels (횡류식 제·배연 시스템의 개선 및 적용성 분석을 위한 모형실험 연구)

  • Kim, Hyo-Gyu;Baek, Doo-San;Kim, Jae-Hyun;Lee, Seong-Won;Yoo, Ji-Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.5
    • /
    • pp.563-574
    • /
    • 2020
  • Currently, road tunnels and railroad tunnels are building smoke control systems to emit toxic gases and smoke from fires. Among the various smoke control systems, the transverse smoke control system has the disadvantage that air supply or exhaust is performed on only half of the cross-section, rather than air supply or exhaust on the entire cross-section of the tunnel as air is supplied or exhausted by partitioning the wind path. Therefore, this study analyzed the effect of exhaustion through numerical analysis and scaled model tests on the zoning smoke control system, which improved the limitations of the transverse smoke control system. As a result of the scaled model test, the transverse ventilation system exhibited a 25.6% smoke control rate based on the state where no smoke was controled, and zoning smoke control system showed a smoke control rate of 40.8%. In addition, as a result of numerical analysis, it was found that transverse ventilation system did not control fire smoke spreading from the tunnel and continued to spread. On the other hand, zoning smoke control system was found to be smoke controled within a certain section due to the air curtain effect and the flue gas effect.

Analysis of Numerical Experiment for Field Application of Cylindrical Slit Type Block Breakwater (실린더 슬릿형 소파블록 방파제의 실해역 적용을 위한 수치실험분석)

  • Park, Sang-Gil;Lee, Joong-Woo;Nam, Ki-Dae;Kim, Pill-Sung
    • Journal of Navigation and Port Research
    • /
    • v.33 no.10
    • /
    • pp.703-707
    • /
    • 2009
  • In order to evaluate applicability of cylindrical slit type block breakwater to the field water, which was designed from the previous physical model study, it is analyzed the calmness of harbor area by the numerical model experiment. For a small fishery port in southern coast of Korea a SWAN model using the wave action balance equation was formulated. The reflection and transmission coefficients induced by the physical model test were introduced to the numerical model. The model response with cylindrical slit type breakwater was compared with the impermeable breakwater case and the possibility of water quality improvement through the water circulation by the new structure was investigated. For numerical simulation, parameters of deepwater design wave from the prediction report II for overall deepwater design wave by KORDI were used and wind parameters from the 50years return period observed for 37years(1970~2006) were adopted in the numerical model. The response of west breakwater in Mijo port applying the NE and NNE waves, which were dominant in this area, was analyzed. It was found that the transmission characteristic of designed cylindrical slit breakwater was well presented in the numerical model.

Engineering Performance and Applicability of Eco-Friendly Concrete for Artificial Reefs Using Electric Arc Furnace Slags (전기로 슬래그를 활용한 인공리프용 친환경콘크리트의 공학적 성능 및 적용성)

  • Jo, Young-Jin;Choi, Se-Hyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.3
    • /
    • pp.533-544
    • /
    • 2015
  • Unlike the concrete structure built on land, that exposed to the marine environment is greatly degraded in durability due to the exposure to not only the physical action caused by sea wind, tide, and wave, but also the harsh conditions, including the chemical erosion and freeze-thaw which result from $SO_4{^{2-}}$, $Cl^-$ and $Mg^{2+}$ ions in seawater. In the process of the large scaled construction of submerged concrete structures, of course environmental hazardous substance, such as alkaline (pH) and heavy metals, may be leached. Thus, this issue needs to be adequately reviewed and studied. Therefore, this study attempted to develop a CSA (Calcium Sulfo Aluminate) activator using electric arc furnace reducing slags, as well as the eco-friendly concrete for artificial reefs using electric arc furnace oxidizing slag as aggregate for concrete. The strength properties of the eco-friendly concrete exposed to the marine environment were lower than those of the normal concrete by curing 28 days. This suggest that additional studies are needed to improve the early strength of the eco-friendly concrete. With respect to seawater resistance of the eco-friendly concrete, the average strength loss against 1 year of curing days reached 8-9%. the eco-friendly concrete using high volume of ground granulated blast furnace slags and high specific gravity of electronic arc furnace oxidizing slag demonstrated the sufficient usability as a freeze-thaw resistant material. With respect to heavy metal leaching properties of the eco-friendly concrete, heavy metal substances were immobilized by chemical bonding in the curing process through the hydration of concrete. Thus, heavy metal substances were neither identified at or below environmental hazard criteria nor detected, suggesting that the eco-friendly concrete is safe in terms of leaching of hazardous substances.

Comparison of Airborne Asbestos Concentrations from Soils in Naturally Occurring Asbestos(NOA) Areas - Activity Based Sampling(ABS) vs. Real-time Asbestos Fiber Monitor(F-1 fiber monitor) - (자연발생석면지역의 토양 내 석면함유율에 따른 비산석면 농도평가 - 활동근거시료채취방법(ABS)과 실시간 섬유 측정 장치(F-1 fiber monitor) 결과 비교 -)

  • Jang, Kwangmyung;Park, Kyunghoon;Choi, Sungwon;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.3
    • /
    • pp.245-256
    • /
    • 2017
  • Objectives: The present study is aimed at performing real-time measurement of fibrous materials using an F-1 fiber monitor, investigating the correlations between the measurements and environmental conditions, and assessing the feasibility of the use of the monitor in actual exposure assessments based on the accuracy and reliability of the device. Methods: Asbestos specimens with a fixed asbestos content were dispersed in a chamber and collected with a particle measuring test device. Measurements obtained by the existing PCM method, and with the F-1 fiber monitor were compared. In addition, concentrations of asbestos fibers obtained by the PCM method, the TEM method, and the F-1 fiber monitor were compared with that of specific ABS scenarios in NOA regions. Correlations of asbestos contents in soil and weather conditions with each method of measurement were analyzed. Results: Laboratory results showed that levels of asbestos fibers measured with each method increased as fiber contents in soil increased. In the accuracy and reproducibility assessment, no significant differences were found between the different methods of measurement. On-site assessment results showed positive correlations among the methods, and these correlations were less significant compared with what was shown by the laboratory results. Levels of asbestos fibers increased as asbestos contents in soil increased, and as temperature increased. Levels of asbestos fibers decreased as humidity increased, and wind speed did not significantly affect the extent to which asbestos fibers were scattered. Conclusions: While it would be premature to replace existing methods with the use of F-1 fiber monitors in real sites based on the results of this study, the monitor may be useful in the screening of the sites, which assesses hazard levels in different regions. Replacement of existing methods with the use of F-1 fiber monitors may be possible after the limitations identified in this study are overcome, and additional assessment data are obtained and reviewed under different conditions to confirm the reliability of the monitor in future research. Obtained assessment results may be used as basic data for the assessment of asbestos hazard in NOA regions.

Developing an On-Line Monitoring System for a Forest Hydrological Environment - Development of Hardware - (산림수문환경(山林水文環境) 모니터링을 위(爲)한 원거리(遠距離) 자동관측(自動觀測)시스템의 개발(開發) - 하드웨어를 중심(中心)으로 -)

  • Lee, Heon Ho;Suk, Soo Il
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.3
    • /
    • pp.405-413
    • /
    • 2000
  • This study was conducted to develop an on-line monitoring system for a forest hydrological environment and its meteorological condition, such as temperature, wind direction and speed, rainfall and water level on V-notch, electrical conductivity(EC), potential of hydrogen(PH) by the motor drive sensor unit and measurement with a single-chip microprocessor as controller. These results are summarized as follows ; 1. The monitoring system consists of a signal process unit, motor drive sensor unit, radio modem unit and power supply. 2. The motor drive sensor unit protects the sensor from swift current or freezing and can constantly maintain fixed water level during measurements. 3. This monitoring system can transfer the data by radio modem. Additionally, this system can monitor hydrological conditions in real time. 4. The hardware was made of several modules with an independent CPU. They can be mounted, removed, repaired and added to. Their function can be changed and expanded. 5. These are the result of an accuracy test, the values of temperature, EC and pH measured within an error range of ${\pm}0.2^{\circ}C$, ${\pm}1{\mu}S$ and ${\pm}0.1pH$ respectively. 6. This monitoring system proved to be able to measure various factors for a forest hydrological environment in various experimental stations.

  • PDF

A Study on the Ecological Restoration Strategies for the Disturbed Landscapes (경관훼손지의 생태적 복구방안에 관한 연구)

  • Kim, Nam-Choon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.1 no.1
    • /
    • pp.28-44
    • /
    • 1998
  • This study was conducted to suggest the ecological restoration strategies for the disturbed landscapes by theoretical study. Especially, it is aimed to suggest three objectives for restoration by using native plants ; (1) prevention or reduction of wind and water erosion, (2) provision of food and cover for variety of animal species, (3) improvement of the visual or aesthetic quality of disturbed sites. The main results were summarized as follows. 1. Cooperation between restoration ecologists and restoration practitioners is needed to delineate a scientific approach to restoration ; (1) Being aware of published literature that describes similar work and/or establish general principles. (2) Preparedness to carry out proper experiments to test ideas. (3) Preparedness to monitor fundamental parameters in a restoration scheme. (4) Providing information about the behavior of species. (5) Publish results. 2. There are three models of succession in theories of plant succession. The tolerance and facilitation models were recommended to ecological restoration. The inhibition model applies in most secondary succession, but the actual species which are introduced first may inhibit the germination and growth of slower-growing species, or they may prevent the growth of other species whose propagules arrive later. 3. The objectives of erosion control, wildlife habitat provision, and visual quality improvement are not mutually exclusive. However, many revegetation practices in the past have emphasized one of these aspects at the expense of the others. 4. A native plant community can be the model of ecological restoration. By stylization/abstraction of native plant community, trying to learn the most essential characteristics of community types - environmental factors ; dominant, prevalent, and "visual essence" species composition - in order to use such information in restoration. 5. After developing mass/spaces plan, match plant communities to the mass/space plan. In utilizing community grouping, there needs aesthetic ability to understand design elements. 6. Several hydrophytes such as Pennisetum saccharifluous, Themeda triandra, Cirsium pendulum show relatively good germination rates. In case of mesophytes and xerophytes, Arundinella hina, Artemisia princeps, Oenothera odorata and legumes seem to have quick-germinating abilities at barren sites. Pinus thunbergii, Rhus chinensis, Evodia daniellii, Alnus firma and Albizzia julibrissin can be considered as "late succession" woody plants because they show low germinating rates and slow growing habitat. 7. The seeds used for restoration should be collected within a certain radius of where it will be planted. Consideration in genetic issues in the collection and use of germplasm can increase the odds for successful restoration efforts. 8. The useful model in the "drift" pattern occurs so abundantly in naturally evolving landscapes. As one species diminishes in density, a second or third species are increased. Thus, dynamic interactions between species are created. Careful using of "drift phenomenon" in planting was recommended. 9. Virtually no stand of vegetation today is immune from the introduction and/or spreading of exotic species. Therefore, the perpetuation of a restored sites requires conscious monitoring and management. Thus, management would be the most important process in ecological restoration. 10. In order to keep the sites "natural", alternative management strategies would be applied in management ; Atenative management strategies are decelerating successional process, accelerating successional processes or modifying species composition. As management tools, mechanical, chemical, biological or environmental factor manipulation, e.g., fire could be used.

  • PDF

A study on the Operation Algorithm for Bi-directional Sectonalizer in Distribution System Interconnected with Distributed Generations (분산전원이 연계된 배전계통의 양방향 구간개폐기의 동작 알고리즘에 관한 연구)

  • Yoon, Gi-Gab;Jeong, Jum-Soo;An, Tae-Pung;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.1802-1809
    • /
    • 2009
  • Abstract The typical distribution systems have the power flow from distribution substations (sources) to customers (load) only as one direction. However, in the case where distributed generations (DG) such as PV system and wind power systems are connected to distribution systems, the DG output variations to distribution systems, so called reverse power flow, may cause the bi-directional power flow. So, the reverse power flow has severe impacts on typical power system, for example power quality problems, protection coordination problems, and so on. Especially, protection devices (sectionalizer) in primary feeder of distribution system interconnected with distributed generations may cause problems of malfunction, and then many customers could have problems like an interruption. So, this paper presents the bi-directional operation algorithm of protection devices to overcome the problems like mal-function. And, also this paper shows the effectiveness of proposed method by using both PSCAD/EMTDC software and test facility of protection devices to simulate the field distribution systems.

Selection of Low Pathogenic Variety in Bacillus thuringiensis to Silworm, Bombyx mori (누에에 대한 저독성 Bacillus thuringiensis 균근의 선발)

  • Kim, Cheol-Yeong;Kim, Yeong-Hun;Gang, Seok-Gwan
    • Journal of Sericultural and Entomological Science
    • /
    • v.28 no.1
    • /
    • pp.43-53
    • /
    • 1986
  • Among many microbial pesticides, Bacillus thuringiensis is one of the most hopeful pesticide and some commercial products have been appearing on the market. Because these commercial products contain living spores and toxins of the organism, there is a danger that living spores of B. thuringiensis may be scattered by wind and cause a great damage in the sericulture areas. In order to avoide these risks it is desirable to select the strain which has low pathogenicity to the silkworm, and at the sometime being highly pathogenic to the pest insects. Thus this study has been carried out to acquire some basic informations about the procedure of desicable strain selection. Three strains of B. thuringiensis var. kurstaki, var. dendrolimus and var. aizawai were used for the pathogenicity test on the silkworm, Bombux mori and the fall webwarm, Hyphantria cunea. Those strains were investigated by the agarose gel electrophoresis patterns of plasmid DNA determine whether mutation had occured. Pathogenicity tests were carried out of using isolated crystal proteins and spore-crystal protein to mixtures of each strain, seperatively. In case of using spore-crystal protein mixture, the order of pathogenicity in varities of B. thuringiensis against B.mopri and H.cunea were kurstaki, aizawai, dendrolimus and kurstaki, dendrolimus, aizawai, respectively. But using isolated crystal proteins, dendrolimus had the highest toxicity to H. cunea and the lowest toxicity to B. mori among tested three strains. From the above results, dendrolimus was presumed the most desirable straing for using microbial pesticide.

  • PDF

A Study on Smart Ground Resistance Measurement Technology Based on Aduino (아두이노 기반 IT융합 스마트 대지저항 측정 기술 연구)

  • Kim, Hong Yong
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.4
    • /
    • pp.684-693
    • /
    • 2021
  • Purpose: The purpose is to establish a safe facility environment from abnormal voltages such as lightning by developing a smart land resistance measuring device that can acquire real-time land resistance data using Arduino. Method: This paper studied design models and application cases by developing a land resistance acquisition and analysis system with Arduino and a power line communication (PLC) system. Some sites in the wind power generation complex in Gyeongsangnam-do were selected as test beds, and real-time land resistance data applied with new technologies were obtained. The electrode arrangement adopted a smart electrode arrangement using a combination of a Wenner four electrode arrangement and a Schlumberger electrode arrangement. Result: First, the characteristic of this technology is that the depth of smart multi-electrodes is organized differently to reduce the error range of the acquired data even in the stratigraphic structure with specificity between floors. Second, IT convergence technology was applied to enable real-time transmission and reception of information on land resistance data acquired from smart ground electrodes through the Internet of Things. Finally, it is possible to establish a regular management system and analyze big data accumulated in the server to check the trend of changes in various elements, and to model the optimal ground algorithm and ground system design for the IT convergence environment. Conclusion: This technology will reduce surge damage caused by lightning on urban infrastructure underlying the 4th industrial era and design an optimized ground system model to protect the safety and life of users. It is also expected to secure intellectual property rights of pure domestic technology to create jobs and revitalize our industry, which has been stagnant as a pandemic in the post-COVID-19 era.