• Title/Summary/Keyword: wind park

Search Result 2,114, Processing Time 0.036 seconds

Evaluation of the Effect of Traffic Control Program on the Ambient Air Quality in Seoul Metropolitan Area Using the Lower Level Stability Index of Atmosphere (하층대기의 연직 안정도 지표를 이용한 차량 2부제의 수도권 대기오염도 저감효과 분석)

  • Kim C.-H.;Park 1.-S.;Lee S.-J.;Kim J.-S.;Hong Y.-D.;Han J.-S.;Jin H.-A.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.2
    • /
    • pp.243-257
    • /
    • 2005
  • The effects of Traffic Control Program (TCP) on the ambient urban air quality of SO$_{2}$, NO$_{2}$, O$_{3}$, and PM$_{10}$ were evaluated in Seoul metropolitan area by using the lower atmospheric vertical stability index and daily mean wind speeds. The vertical stability index; temperature lapse rate between 1000 hPa and 850 hPa geopotential height fields, were used to identify daily vertical stability index during the 2002 World Cup period where traffic amount was reportedly reduced to half the number of vehicles. The indicated air quality levels of TCP days were then compared with those of the cases observed with analogous vertical stability during the recent 3 years from 2000 to 2002. The result indicates that the effect of TCP on the primary air pollutants are found to be approximately 39$\%$, 23$\%$ and 20$\%$ lower for SO$_{2}$, NO$_{2}$ and PM$_{10}$, respectively. The secondary air pollutant; ozone, showed relatively smaller decreasing rate (13$\%$) of daily mean concentrations (even increased during the night time). The comparison of daily maximum or peak concentrations reveals that the pronounced decreasing effects of TCP on the ambient air quality for both primary and secondary air pollutants, suggesting that TCP is one of the effective strategies to control peak or higher concentrations for most urban scale air pollutants in and around the Seoul metropolitan area.

Field Survey and Analysis of Natural Ventilation Characteristics of Multi-span Greenhouse with Different Roof Vent (연동형 비닐하우스의 환기창 형태 조사 및 자연환기 효과 분석)

  • Park, Min jung;Choi, Duck kyu;Son, Jin kwan;Yoon, Sung-Wook;Kim, Hee tae;Lee, Seung-Kee;Kang, Dong hyeon
    • Journal of Bio-Environment Control
    • /
    • v.29 no.1
    • /
    • pp.36-42
    • /
    • 2020
  • The objectives of this study were to investigate the standard and roof vent type of multi-span greenhouse and to analyze the characteristics of natural ventilation of multi-span greenhouse with different roof vent using computational fluid dynamics (CFD) code. The vent area proportion of surveyed farms averaged 10%, it was analyzed that the vent design for natural ventilation is insufficient. The results of natural ventilation efficiency of multi-span greenhouse according to roof vent type showed that the temperature of the position in which the crops grew was the lowest in the conical roof vent type and the highest in the half conical roof vent type. For the natural ventilation effect, the conical roof vent type was the best one, but the structural stability should be evaluated in light of wind load.

Drift and Distribution Properties of Pesticide Spray Solution Applied Aerially by manned-Helicopter (헬기를 이용한 항공살포 농약의 비산 및 분포 특성)

  • Jin, Yong-Duk;Lee, Hee-Dong;Park, Yeon-Ki;Kim, Jin-Bae;Kwon, Oh-Kyung
    • The Korean Journal of Pesticide Science
    • /
    • v.12 no.4
    • /
    • pp.351-356
    • /
    • 2008
  • This study was carried out to assess adoptability and environment impacts of ultra low volume (ULV) pesticide spray solutions aerially sprayed by manned-helicopter. Uniformity of the deposited amount in paddy fields was uneven, showing $3.1{\sim}4.7$ times differences among surveyed sites. Drifting distance of aerially sprayed droplets from the target area was within 30 m in the wind direction and 20 m in the opposite direction. Most of the aerially sprayed pesticides were deposited in/on rice plants, while those in submerged paddy water and soil were relatively small. The degradation rate of the deposited pesticides was in the decreasing order of rice plants, paddy water and soil. Soil residues of pesticides in the aerially sprayed rice paddy fields after harvest ranged from non-detected to 0.201 mg/kg. However, no pesticides were detected in brown rice and rice straw. No phytotoxic symtoms were observed in rice plants and nearby non-target crops by the sprayed pesticides.

Characteristics of tropical cyclones over the western North Pacific in 2007 (2007년 태풍 특징)

  • Cha, Eun-Jeong;Park, Yun-Ho;Kwon, H. Joe
    • Atmosphere
    • /
    • v.18 no.3
    • /
    • pp.183-197
    • /
    • 2008
  • The purpose of this study is to summarize tropical cyclone activity in 2007. 24 tropical cyclones of tropical storm (TS) intensity or higher formed in the western North Pacific and the South China Sea in 2007. The total number is less than the thirty-year (1971~2000) average frequency of 26.7. Out of twenty four tropical cyclones, 14 TCs reached typhoon (TY) intensity, while the rest 10 only reached severe tropical storm (STS) and tropical storm (TS) intensity - four STS and six TS storms. The tropical cyclone season in 2007 began in April with the formation of KONG-REY (0701). From April to May, two TCs formed in the western North Pacific in response to enhanced convective activity there. From June to July, convective activity turned inactive over the sea around the Philippines and in the South China Sea, and the subtropical high was weak over the south of Japan. MAN-YI (0704) and USAGI (0705) moved northwestward and hit Japan, bringing serious damage to the country. After August, convective activity became enhanced over the sea east of the Philippines, and the subtropical high turned strong over the sea south of Japan. Many TCs, which formed over the sea east of the Philippines and in the South China Sea, moved westward and hit China and Vietnam. PABUK (0706), WUTIP (0707), SEPAT (0708), WIPHA (0712), LEKIMA (0714) and KROSA (0715) brought serious damage to some countries including China, the Philippines and Vietnam. On the other hand, FITOW (0709) and NARI (0711) moved northward, bringing serious damage to Japan and Korea. After HAIYAN (0716), all four TCs except FAXAI (0720) formed over the sea east of $140^{\circ}E$. Three typhoons among them affected Republic of Korea, MAN-YI (0704), USAGI (0705) and NARI (0711). Particularly, NARI (0711) moved northward and made landfall at Goheng Peninsula ($34.5^{\circ}N$, $127.4^{\circ}E$) in 1815 KST 16 September. Due to $11^{th}$ typhoon NARI, strong wind and record-breaking rainfall amount was observed in Jeju Island. It was reported that the daily precipitation was 420.0 mm at Jeju city, Jeju Island on 16 September the highest daily rainfall since Jeju began keeping records in 1927. This typhoon hit the southern part of the Korean peninsula and Jeju Island. 18 people lost their lives, 14,170 people were evacuated and US$ 1.6 billion property damage was occurred.

A study on design and performance test of fire door with high endurance performance in submarine tunnel (고내구성능을 갖는 해저터널 방화문 설계방안 및 성능시험 연구)

  • Park, Sang-Heon;Hwang, Ju-Hwan;Choi, Young-Hwan;An, Sung-Joo;Yoo, Yong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.331-346
    • /
    • 2018
  • In the tunnel of domestic high - speed railway, the main fire - fighting facility, fire - extinguishing passageway, is installed. However, due to the high pressure of the high - speed train, frequent breakage and maintenance are caused by strong shock and long - term vibration. In order to solve these problems, it is necessary to improve the fire door, but in Korea, it is installed by submitting a certificate by simple KS F 2296 performance test. At present, it is developed as a simple test certification by producing a real scale fireproof door without the theoretical examination in advance, so that a high cost for improvement is occurring in Korea. Therefore, through this study, structural analysis study which can preliminary structure review was carried out in order to design the refuge connection passage fire door and to improve the performance improvement. In order to secure the reliability of the result value, the official authentication test (KS F 2296) were compared.

Study on the Gas Tight Shut-off Valve of NBC Shelter using Positive Pressure Measurement and Chemical Detection Module (양압측정 및 화학탐지 모듈을 적용한 화생방 방호시설의 가스차단밸브에 관한 연구)

  • Park, Hyoung-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.417-422
    • /
    • 2017
  • One of the most frightening aspects of weapons of mass destruction (WMD) is their ability to cause death in very small quantities without being visible to the public. The military authorities are making considerable effort to ensure the survivability of the combatants in the event of NBC(Nuclear, Biological and Chemical) contamination. Therefore, in this study, modules were developed for the measurement of the positive pressure and for the detection of the chemicals used for the control of the various shut-off valves used in an NBC shelter. In addition, a high performance gas tight shut-off valve was developed that can overcome the disadvantages associated with manual manufacturing, such as the occurrence of defective products and high manufacturing cost. By applying the positive pressure measurement and chemical detection modules, this valve was able to be used to control the facility. The developed gas-tight shut-off valve maintained airtight characteristics at a pressure loss of 28[Pa] at the prescribed wind velocity and an internal pressure of 30[kPa]. It is expected to be possible to control the gas-tight shut-off valve through the remote measurement of the positive pressure, thereby ensuring the foreign independence of import substitution and defense related technology in the future. In addition, by installing these valves in all of the intake ports or exhaust ports connected to the outside of the NBC shelter, it is possible to prevent the damage resulting from the rapid inflow of the storm pressure caused by conventional weapons and nuclear explosions, thereby protecting the people and equipment in the shelter.

Characteristics of Tidal Flow Simulation of Real Tide in West-South Coastal Waters of Korea (실조석에 의한 한국 서남해 연안역에서 해수유동의 재현특성)

  • Jeong, Seung-Myong;Park, Il-Heum
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.5
    • /
    • pp.531-541
    • /
    • 2020
  • In this study, a computed tide of a real tide was introduced to improve the numerical solutions for tides and tidal flow simulations. The real tide was defined considering the nodal modulation amplitude, phase correction factor, astronomical argument, and tidal harmonic constants of all the constituents. The numerical simulation was performed using the real tide parameters for the west-south coastal waters of Korea, where the observation data for tides, tidal currents, waves, and winds over two seasons exist. The tidal flow simulation of the real tide was simulated successfully. The correlation coefficient between the observed and calculated values was 1.0, which indicated both accurate amplitude and phase. The U- and V-components of the tidal current obtained for the real tide had average valid correlations of 0.83 and 0.936, respectively. The speed error for the residual current was 0.006 m/s on the average, which indicated an insignificant difference, and the directional behavior of the residual current was very similar. In addition, the velocity error was attributed to various weather effects, such as high waves and wind storms. Therefore, this model is expected to improve current solutions provided that weathering forces, such as waves and winds, are considered.

Investigation of the Soundscapes of Jeju Olle Route via Soundwalking (Soundwalking을 통한 제주도 올레길의 소리풍경 조사)

  • Park, Chan-Jae;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.8
    • /
    • pp.410-420
    • /
    • 2011
  • The present study aims to investigate the soundscapes of Jeju olle route through the soundwalking. In order to do this, sound measurements and sound recording were undertaken at 10 points along Jeju olle route. Also, loudness of background sound and figure sound were examined. Subjective surveys were carried out using questionnaire and interviews with 32 tourists and 5 acoustical specialists in order to investigate the loudest sound, most pleasant and unpleasant sound, and impressive sound among 17 natural and artificial sounds. Additionally, laboratory experiments were achieved to evaluates sound that have been recorded at the field using same questionnaire and the results were compared with those of field experiments. As a result, the sound heard most in Jeju olle route is the sea wave sound, wind sound, automobile noise, and human voice. It was revealed that the most pleasant sound consisted of nature sound among them, and that unpleasant sounds are artificial sounds. The results of subjective test denote that unpleasant sound is affected by ratio of artificial sound and nature sound. And this also affects the assessment about the loudness of the sound. Also, it was found that the results of both field test and laboratory test are closely correlated in the evaluation of loudness of sound and unpleasant feeling.

LONGITUDINAL AND SEASONAL VARIATIONS OF THE ELECTRON TEMPERATURE AND DENSITY IN THE LOW_LATITUDE TOPSIDE IONOSPHERE OBSERVED BY KOMPSAT-1 (다목적 실용위성 1호로 측정한 저위도 상부 이온층의 전자 온도와 전자 밀도의 경도 및 계절별 변화)

  • Kim, Hee-jun;Park, Sun-Mie;Lee, Jae-Jin;Lee, En-sang;Min, Kyoung-Wook;Han, Won-yong;Nam, Uk-Won;Jin, Ho
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.2
    • /
    • pp.123-132
    • /
    • 2002
  • The electron density and temperature in the topside ionosphere are observed by the ionosphere Measurement Sensor (IMS) onboard the KOMPSAT-1, which has the sun-synchronous orbit of the altitude of 685 km and the orbital inclination of $98^{\circ}$ with a descending node at 22:50LT. Observations have been analyzed to determine the seasonal variations of the electron density and temperature in the low-latitude region. Only the night-time (22:50LT) behavior on magnetically quiet days (Kp < 4) has been examined. Observations show a strong longitudinal and seasonal variation. Generally, in the dip equator the density increases and the temperature decreases. In equinox the latitudinal distributions of the electron density and temperature are quite symmetric about the dip equator. However, the local maximum of the density and the local minimum of the temperature shift toward the Northern hemisphere in summer solstice but the Southern hemisphere in winter solstice. Such variations are due to the influences of field-aligned plasma transport induced by F region neutral wind. Compared with the IRI95 model, the observed electron density and temperature show significant differences from those predicted by the IRI95 model.

A Study on Performance of Energy Recovery Ventilator under Outdoor Conditions in Korea (국내 외기조건에서 폐열회수 환기장치의 성능에 관한 연구)

  • Kim, Il-Gyoum;Park, Woo-Cheul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.52-57
    • /
    • 2009
  • In this study, a simulation program has been developed to predict the performance of energy recovery ventilators fur various indoor and outdoor conditions. In order to get a fundamental data about domestic air condition, the heat recovery ventilator is selected with the product of the wind quantity $250m^3/h$ Japanese M companies which are satisfied at High Efficiency Certification Standards. At the case on which the heat recovery ventilator is established, heating load decreases by 69.1% and cooling load decreases by 59.4% in Seoul, and heating load decreases by 66.4% and cooling load decreases by 59.6% in Pusan. The maximum humidification load of winter or summer time with $0.737{\ell}/h$ or $1.008{\ell}/h$ occurred in March from Kangnung or August from Mokpo respectively. In Southern part region and East Sea of winter time, the condensation or frost on exhaust side dose not occurred on exhaust side, but the area of that outside is occurred. Therefore, the preventive measure from the area except a southern part region and the east coast area must be considered, in order to condense or frost not to occur on exhaustion side in winter.