• Title/Summary/Keyword: wide fault

Search Result 166, Processing Time 0.033 seconds

A Study on the Design of a Fault-Tolerance Rotor Magnetic Bearing Systems (고장허용 회전체 자기베어링 시스템의 설계 연구)

  • 조성락;경진호;노승국;박종권
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.304-308
    • /
    • 2004
  • One of the obstacles for a magnetic bearing to be used in the wide range of industrial applications is the failure modes associated with magnetic bearings. These failure modes include power amplifier faults, position sensor faults, and the malfunction of controllers. Fault-tolerant magnetic bearing systems have been proposed so that the system can operate in spite of some faults. In this paper, we designed and tested a fault-tolerant magnetic bearing system. The system can cope with the actuator faults as well as the faults in position sensors, which are the two major fault modes in a magnetic bearing system.

  • PDF

Development of an Expert System for the Fault Diagnosis in power System (전력계통의 고장진단 전문가 시스템에 관한연구)

  • 박영문;이흥재
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.1
    • /
    • pp.16-21
    • /
    • 1990
  • A Knowledge based expert system is a computer program that emulates the reasoning process of a human expert in a specific problem domain. Expert system has the potential to solve a wide range of problems which require knowledge about the problem rather than a purely analytical approach. This papaer presents the application of knowledge based expert system to power system fault diagnosis. The contents of expert system develpped in this paper is judgement of fault section from a given alarm sets and production of all possible hypothesis for the single fault. Both relay failures and circuit breaker failures are considered simultaneously. Although many types of relay are used in actual system, experts recognize ones as several typical signals corresponding to the fault types. Therefore relays are classified into several types. The expert system is written in an artificial intelligence language "PROLOG" . Best-first search method is used for problem solving. Both forward chaining and backward chaining schemes are used in reasoning process. The application to a part of actual power system proves the availability of the developed expert system.

  • PDF

Mechanical Properties of Fault Rocks in Korea

  • Seo, Yong-Seok;Yun, Hyun-Seok;Ban, Jae-Doo;Lee, Chung-Ki
    • The Journal of Engineering Geology
    • /
    • v.26 no.4
    • /
    • pp.571-581
    • /
    • 2016
  • To understand the mechanical properties of fault rocks, data from 584 in situ and laboratory tests on fault rocks from 33 tunnels were analyzed. The unit weights of the fault rocks range from 17.3 to $28.2kN/m^3$ and the cohesion and friction angles vary from 5 to 260 kPa and $14.7^{\circ}$ to $44.0^{\circ}$, respectively. The modulus of deformation and elasticity were generally < 200 MPa. In most cases, the uniaxial compressive strength was < 0.5 MPa, and Poisson's ratios were mainly 0.20-0.35. The mechanical properties of individual rock types were analyzed using box plots, revealing that the cohesion values and friction angles of shale and phyllite have relatively wide inter-quartile ranges and that the modulus of deformation and elasticity of shale have the lowest values of all rock types. In the analysis of mechanical properties by components of fault rocks, the largest values were shown in damage zones of individual rock types.

A Novel Fault Detection Scheme for Voltage Fed PWM Inverter (전압형 PWM 인버터의 새로운 고장 검출 기법)

  • Yu, Ok-Sun;Park, Nam-Ju;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.1-8
    • /
    • 2007
  • This paper presents a new fault detection scheme for voltage fed inverter to improve the reliability of power electronic system, which is of paramount importance in the wide industrial applications. The proposed method is achieved by using voltage across lower switches in each phase under the switch fault condition. The reconfiguration method is achieved by the four-switch topology connecting a faulty leg to the middle point of DC-link using bidirectional switches. The proposed method has a simple algorithm and fast fault detection time. Therefore, normal operation of the system after faults is continuously achieved by reconfiguration of system topology. The superior performance of the proposed fault detection and tolerance method are proved by simulation.

ADAPTIVE FDI FOR AUTOMOTIVE ENGINE AIR PATH AND ROBUSTNESS ASSESSMENT UNDER CLOSED-LOOP CONTROL

  • Sangha, M.S.;Yu, D.L.;Gomm, J.B.
    • International Journal of Automotive Technology
    • /
    • v.8 no.5
    • /
    • pp.637-650
    • /
    • 2007
  • A new on-line fault detection and isolation(FDI) scheme has been proposed for engines using an adaptive neural network classifier; this paper investigates the robustness of this scheme by evaluating in a wide range of operational modes. The neural classifier is made adaptive to cope with the significant parameter uncertainty, disturbances, and environmental changes. The developed scheme is capable of diagnosing faults in the on-line mode and can be directly implemented in an on-board diagnosis system(hardware). The robustness of the FDI for the closed-loop system with crankshaft speed feedback is investigated by testing it for a wide range of operational modes, including robustness against fixed and sinusoidal throttle angle inputs, change in load, change in an engine parameter, and all changes occurring simultaneously. The evaluations are performed using a mean value engine model(MVEM), which is a widely used benchmark model for engine control system and FDI system design. The simulation results confirm the robustness of the proposed method for various uncertainties and disturbances.

Machine Fault Diagnosis and Prognosis: The State of The Art

  • Tung, Tran Van;Yang, Bo-Suk
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.1
    • /
    • pp.61-71
    • /
    • 2009
  • Machine fault diagnostic and prognostic techniques have been the considerable subjects of condition-based maintenance system in the recent time due to the potential advantages that could be gained from reducing downtime, decreasing maintenance costs, and increasing machine availability. For the past few years, research on machine fault diagnosis and prognosis has been developing rapidly. These publications covered in the wide range of statistical approaches to model-based approaches. With the aim of synthesizing and providing the information of these researches for researcher's community, this paper attempts to summarize and classify the recent published techniques in diagnosis and prognosis of rotating machinery. Furthermore, it also discusses the opportunities as well as the challenges for conducting advance research in the field of machine prognosis.

Position dependence of quench progress in resistive superconducting fault current limiters (저항형 초전도 한류기에서의 위치에 따른 퀜치진행 변화)

  • 김혜림;현옥배;최효상;황시돌;김상준;임해용;김인선
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2000.02a
    • /
    • pp.139-142
    • /
    • 2000
  • We fabricated resistive superconducting fault current limiters based on $YBa_{2}Cu_{3}O_{7}$ thin films and investigated position dependence of quench progress. The $YBa_{2}Cu_{3}O_{7}$ film was coated insitu with a gold layer and patterned into 1 mm wide meander lines by photolithography. The limiters were tested with simulated fault currents. Quench progress depended significantly on the position in the limiter with respect to electrodes. The limiters quenched fastest at the part farthest from the electrodes. the limiters quenched fastest at the part farthest from the electrodes and slowest next to the electrodes. This phenomenon was more prominent near the minimum quench current. At high fault current the quench started simultaneously on all parts of the limiters and the subsequent progress of quench depended only weakly on the position. The heat transfer from limiter meander lines to electrodes explains these results.

  • PDF

Trend-adaptive Anomaly Detection with Multi-Scale PCA in IoT Networks (IoT 네트워크에서 다중 스케일 PCA 를 사용한 트렌드 적응형 이상 탐지)

  • Dang, Thien-Binh;Tran, Manh-Hung;Le, Duc-Tai;Choo, Hyunseung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2018.05a
    • /
    • pp.562-565
    • /
    • 2018
  • A wide range of IoT applications use information collected from networks of sensors for monitoring and controlling purposes. However, the frequent appearance of fault data makes it difficult to extract correct information, thereby sending incorrect commands to actuators that can threaten human privacy and safety. For this reason, it is necessary to have a mechanism to detect fault data collected from sensors. In this paper, we present a trend-adaptive multi-scale principal component analysis (Trend-adaptive MS-PCA) model for data fault detection. The proposed model inherits advantages of Discrete Wavelet Transform (DWT) in capturing time-frequency information and advantages of PCA in extracting correlation among sensors' data. Experimental results on a real dataset show the high effectiveness of the proposed model in data fault detection.

Resistance distribution in large area thin film type SFCLS (박막형 대면적 초전도 한류소자에서의 저항 분포)

  • 김혜림;최효상;현옥배
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.89-93
    • /
    • 2002
  • We investigated the resistance distribution n 4"diameter SFCLS. $YBa_2CU_3O_7$ films coated in-situ with a gold layer were patterned into 3 mm wide 142 cm long meander lines by Photolithography. The limiters were tested with simulated fault currents. The resistance was uniform all over the film except at the edge. At lower source voltages, CFCLs did not quench simultaneously and the resistance distribution was less uniform. Compared with 2" diameter SFCLS 4" SFCLS had similar values and time dependence of resistivity at similar electric fields The resistance distribution was more uniform in 4" SFCLS. The area at the edge where the distribution was not uniform was around 3 mm wide in SFCLs of both sizes. The experimental results were quantitatively explained with a heat transfer concept.

Seismic strain analysis of buried pipelines in a fault zone using hybrid FEM-ANN approach

  • Shokouhi, Seyed Kazem Sadat;Dolatshah, Azam;Ghobakhloo, Ehsan
    • Earthquakes and Structures
    • /
    • v.5 no.4
    • /
    • pp.417-438
    • /
    • 2013
  • This study was concerned on the application of a hybrid approach for analyzing the buried pipelines deformations subjected to earthquakes. Nonlinear time-history analysis of Finite Element (FE) model of buried pipelines, which was modeled using laboratory data, has been performed via selected earthquakes. In order to verify the FE model with experiments, a statistical test was done which demonstrated a good conformity. Then, the FE model was developed and the optimum intersection angle of pipeline and fault was obtained via genetic algorithm. Transient seismic strain of buried pipeline in the optimum intersection angle of pipeline and fault was investigated considering the pipes diameter, the distance of pipes from fault, the soil friction angles and seismic response duration of buried pipelines. Also, a two-layer perceptron Artificial Neural Network (ANN) was trained using results of FE model, and a nonlinear relationship was obtained to predict the bending strain of buried pipelines based on the pipes diameter, intersection angles of the pipelines and fault, the soil friction angles, distance of pipes from the fault, and seismic response duration; whereas it contains a wide range of initial input data without any requirement to laboratory measurements.