• 제목/요약/키워드: wide connection

검색결과 334건 처리시간 0.024초

Advanced Field Weakening Control for Maximum Output Power Operation of Induction Motor in a Limited Environment

  • Seo, Yong-Joo;Go, Hee-Young;Kim, Jang-Mok
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 추계학술대회 논문집
    • /
    • pp.217-218
    • /
    • 2012
  • A load motor used for warship or submarine is with limited volume and weight, also specific environmental tests like impact, vibration, noise, temperature and EMC/EMI have to be satisfied. Induction motors, synchronous motors, BLDC motor and etc, are used depending on the purpose of using military equipment. Induction Motors are used for a number of military equipment more commonly due to the robust structure and simple maintenance. Domestic and foreign warships have a wide range of voltages as the DC voltage sources with battery are mainly used for them. The ${\Delta}-connection$ operation of the induction motor is required to make the maximum power in a low voltage level. But the elements' temperature of the inverter increases due to high input current when it is in the ${\Delta}-connection$ operation. Therefore, the induction motor must be driven with the Y-connection. The lack of voltage needs to be with the field weakening control. This paper suggests the optimum field weakening control algorithm to drive the induction motor with maximum power in a limited thermal and DC voltage condition.

  • PDF

파괴 메커니즘을 고려한 내부 포스트텐션 플랫 플레이트 슬래브-기둥 접합부의 강도식 평가 (Strength of Interior Post-Tensioned Flat Plate Slab-Column Connection based on Failure Mechanism)

  • 김민남;하상수;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.126-129
    • /
    • 2006
  • A bending moment $M_u$ transferred at slab-column connection is resisted at the slab critical section by flexure and shear. The ACI 318-05 Building Code(1) gives an empirical equation for the fraction ${\gamma}_{\upsilon}$ of the moment $M_u$ to be transferred by shear at the slab critical section at d/2 from the column face and also the effective wide(c+3h). The equation is based on tests of interior slab-column connections without shear reinforcement. In order to investigate the data eight test specimens were examined. The test shows that increased slab load substantially reduces both the unbalanced moment capacity and the lateral drift capacity of the connection. Especially, the specimens with the bottom reinforcement existence and nonexistence, appears remarkable differences. Studies also show that the code equation for ${\gamma}_{\upsilon}$ does not apply to all cases. The purpose of this study is to compare the test results with present ACI 318-05 Building Code provisions for design of slab-column connections and with the analysis of the experimental data for a new limitation of strength equation without shear reinforcement and bottom reinforcement.

  • PDF

Performance Prediction & Analysis of MGT Co-generation System

  • Hur, Kwang-Beom;Park, Jung-Keuk;Rhim, Sang-Kyu;Kim, Jae-Hoon
    • 신재생에너지
    • /
    • 제2권3호
    • /
    • pp.15-22
    • /
    • 2006
  • As the distributed generation becomes more reliable and economically feasible, it is expected that a higher application of the distributed generation units would be interconnected to the existing grids. This new market penetration using the distributed generation technology is linked to a large number of factors like economics and performance, safety and reliability, market regulations, environmental issues, or grid connection standards. KEPCO, a government company in Korea, has performed the project to identify and evaluate the performance of Micro Gas Turbine(MGT) technologies focused on 30, 60kW-class grid-connected optimization and combined Heat & Power performance. This paper describes the results for the mechanical, electrical, and environmental tests of MGT on actual grid-connection under Korean regulations. As one of the achievements, the simulation model of Exhaust-gas Absorption Chiller was developed, so that it will be able to analyze or propose new distributed generation system using MGT. In addition, KEPCO carried out the field testing of the MGT Cogeneration system at the R&D Center Building, KEPCO. The field test was conducted in order to respond to a wide variety of needs for heat recovery and utilization. The suggested method and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

  • PDF

The stability of semi-rigid skeletal structures accounting for shear deformations

  • Gorgun, Halil
    • Structural Engineering and Mechanics
    • /
    • 제57권6호
    • /
    • pp.1065-1084
    • /
    • 2016
  • The analysis and design of skeletal structures is greatly influenced by the behaviour of beam-to-column connections, where patented designs have led to a wide range of types with differing structural quantities. The behaviour of beam-to-column connections plays an important role in the analysis and design of framed structures. This paper presents an overview of the influence of connection behaviour on structural stability, in the in-plane (bending) mode of sway. A computer-based method is presented for geometrically nonlinear plane frames with semi-rigid connections accounting for shear deformations. The analytical procedure employs transcendental modified stability functions to model the effect of axial force on the stiffness of members. The member stiffness matrix were found. The critical load has been searched as a suitable load parameter for the loss of stability of the system. Several examples are presented to demonstrate the validity of the analysis procedure. The method is readily implemented on a computer using matrix structural analysis techniques and is applicable for the efficient nonlinear analysis of frameworks. Combined with a parametric column effective length study, connection and frame stiffness are used to propose a method for the analysis of semi-rigid frames where column effective lengths are greatly reduced and second order (deflection induced) bending moments in the column may be distributed via the connectors to the beams, leading to significant economies.

상가건물 소방용 연결송수관설비 송수구의 개선방안에 관한 연구 (A Study on the Improvement Method of the Fire Department Connection for Fire Fighting at the Shopping Center Building)

  • 이영삼
    • 대한안전경영과학회지
    • /
    • 제18권4호
    • /
    • pp.11-17
    • /
    • 2016
  • Currently, the number of a shopping center building is increasing because most people want to go a shopping center building easily for buying many things and eating some foods. That are a normal trend these days. However, the increasing number of shopping center buildings has been increasing the number of shopping center building fires which also have been making social problems. Therefore, this study was conducted for the fire department connection among other fire facilities because it is important for fire suppression. The research subject is on the fire department connections that are on 70 shopping center buildings of more than 5 years old constructed. Survey and analysis were conducted for 70 fire department connections. The result of this study is that all installed fire department connections have a type that includes one or two holes each at 65mm wide, and the average distance between fire department connections and access roads is 4.85m. The total average percentage of insufficiency conditions such as drive ways for fire trucks, visibility, accessibility, pressure range sign, installed height, cover of the hole, etc. is 45.3%. So improvement of law and systems, that are fire facility construction and maintenance implementations, will be needed in my opinion.

부분 폐정맥 환류이상과 심방중격 결손증을 동반한 삼중방심의 치험 1례 (Cor Triatriatum Associated with Atrial Septal Defect and Partial Anomalous Pulmonary Venous Return: Report of A Case)

  • 이철주
    • Journal of Chest Surgery
    • /
    • 제18권3호
    • /
    • pp.440-445
    • /
    • 1985
  • Cor triatriatum is a variant of abnormal connection between the pulmonary vein and true left atrium, which is separated from accessory left atrium receiving pulmonary venous blood flow by fibromuscular diaphragm. Usually it is diagnosed after operation because difficulty in visualization of the diaphragm by conventional diagnostic tools. We experienced a rare entity of congenital heart disease diagnosed as car triatriatum with atrial septal defect and partial anomalous pulmonary venous return after completing operation, which was diagnosed as ASD with PAPVR preoperatively. Anomalous right pulmonary venous opening was located at right atrium, secundum type defect of atrial septum was present, and dual chambered left atrium without connection was also seen. Excision of the diaphragm and wide patch repair of ASD including right pulmonary vein were performed with good postoperative results. Herewith, we report this case with review of literatures.

  • PDF

ATM망의 비연결형 서버를 위한 고속 CAM ASIC 설계 (ASIC design of high speed CAM for connectionless server of ATM network)

  • 백덕수;김형균;이완범
    • 한국통신학회논문지
    • /
    • 제22권7호
    • /
    • pp.1403-1410
    • /
    • 1997
  • Because streaming mode connection server suitable to wide area ATM networks performs transmission, reception and lookup with time restriction for the transmission time of a cell, it has demerits of large cell loss incase that burst traffic occurs. Therefore, in this paper to decrease cell loss we propose a high speed CAM (Content Addressable Memory) which is capable of processing data of streaming mode connections server at a high speed. the proposed CAM is applied to forwarding table VPC map which performs function to output connection numbers about input VPI(Virtual Path Identifier)/VCI(Virtual Channel Identifier). The designed high speed CAM consist of DBL(Dual Bit Line) CAM structure performed independently write operation and match operation and two-port SRAM structure. Also, its simulation verification and full-custom layout is performed by Hspice and Composs tools in 0.8 .$\mu$m design rule.

  • PDF

각형강관 기둥을 가진 철골모멘트 접합부의 변형능력 (Deformation Capacity of Steel Moment Connections with RHS Column)

  • 김영주;오상훈;유홍식
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.249-258
    • /
    • 2006
  • In this paper, deformation capacity of steel moment connections with RHS column was investigated. Initially, non-linear finite element analysis of five bate steel beam models was conducted. The models were designed to have different detail at their beam-to-column connection, so that the flexural moment capacity was different respectively. Analysis results showed 4hat the moment transfer efficiency of the analytical model with RHS-column was poor when comparing to model with WF(Wide flnage)-column due to out-of-plane deformation of the RHS-column flange. The presence of scallop and thin plate of RHS column was also a reason of the decrease of moment transfer efficiency, which would result in a potential fracture of tile steel beam-to-column connections. Further test on beam-to-column connections with RHS column revealed that the moment transfer efficiency of a beam web decreased due to the out-of-plane deformation of column flange, which led to premature failure of the connection.

  • PDF

Physical Connection between Ionized Outflows and Radio jets in Young Radio Quasars.

  • Hwang, Seong Hyeon;Kim, Minjin
    • 천문학회보
    • /
    • 제45권1호
    • /
    • pp.65.2-65.2
    • /
    • 2020
  • We present NIR spectroscopic data of young radio quasars obtained from Flamingos-2 (F2) at Gemini-South. The targets are originally selected from Wide-Field Infrared Survey Explorer survey in combination with radio survey data, such as FIRST and NVSS. Our goal is to find observational evidence of jet-driven outflows, which is expected to be present in young luminous quasars from the theoretical studies. While 16 targets were observed with F2, narrow emission lines ([O III] or Hα) were detected in 7 targets. FWHM of the emission lines (up to 2500 km/s) were remarkably broad compared to ordinary quasars, revealing the presence of strong outflows. The black hole mass estimated from Eddington limit ranges from ~108 to 109 solar mass, indicating that the target quasars are likely to be progenitors of massive galaxies. Finally, we present the comparisons between the outflow velocity and the physical properties of radio jets derived from the VLA radio imaging data, in order to investigate the physical connection between the ionized outflows and radio jets.

  • PDF

위성탑재 영상레이다(SAR)의 광역감시 모드에 대한 체계 성능 분석 (Performance Analysis in Wide Swath Mode on a Spaceborne SAR System)

  • 이범석
    • 한국군사과학기술학회지
    • /
    • 제4권1호
    • /
    • pp.104-123
    • /
    • 2001
  • Synthetic Aperture Radar(SAR) can provide radar imagery in all weather, day and night situations. Recently SAR system consisted of several imaging modes, has been used for not only military purpose, but also commercial and scientific applications. This paper firstly reviews spaceborne SAR theory, specially scansar principle, and secondly the theories and the design procedures of system performance analysis in the scansar mode, which are different from the ones in the conventional stripmap mode. Based on the SAR-related knowledge, it lastly derives the results of performance analysis in wide swath mode using the scansar technique at the design phase. It shows that these results can meet the system requirements as given the customer. In future, they will continuously be updated using the real measurement data, in connection with the development of a spaceborne SAR system.

  • PDF