• Title/Summary/Keyword: wide beams

Search Result 154, Processing Time 0.023 seconds

Torsional behaviour of reinforced concrete beams retrofitted with aramid fiber

  • Kandekar, Sachin B.;Talikoti, Rajashekhar S.
    • Advances in concrete construction
    • /
    • v.9 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • Retrofitting is an alteration of existing member or component of the structure. In civil engineering point of view, it is called strengthening of the old structure. Deterioration of structures may be due to aging, corrosion, failure of joints, earthquake forces, increase in service loads, etc. Such structures need urgent repair, retrofitting and strengthening to avoid collapse, cracking and loss in strength or deflection. Advanced techniques are required to be developed for the repair of structural components to replace conventional techniques. This paper focuses exclusively on torsional behaviour of Reinforced Concrete (RC) beams and retrofitted RC beams wrapped with aramid fiber. Beams were retrofitted with aramid fiber by full wrapping and in the form of 150 mm wide strips at a spacing of 100 mm, 150 mm, 200 mm respectively using epoxy resin and hardener. A total 15 numbers of RC beams of 150 mm×300 mm×1300 mm in size were cast, 3 beams are tested as control specimens, and 12 beams are tested for torsion up to the failure and then retrofitted with aramid fiber. Experimental results are validated with the help of data obtained by finite element analysis using ANSYS. The full wrapping configuration of aramid fiber regains 105% strength after retrofitting. With the increase in spacing of fabric material, torsional strength reduces to 82% with about 45% saving in material.

Parametric study of shear capacity of beams having GFRP reinforcement

  • Vora, Tarak P.;Shah, Bharat J.
    • Advances in concrete construction
    • /
    • v.13 no.2
    • /
    • pp.183-190
    • /
    • 2022
  • A wide range of experimental bases and improved performance with different forms of Fiber Reinforced Polymer (FRP) have attracted researchers to produce eco-friendly and sustainable structures. The reinforced concrete (RC) beam's shear capacity has remained a complex phenomenon because of various parameters affecting. Design recommendations for the shear capacity of RC elements having FRP reinforcement need a more experimental database to improve design recommendations because almost all the recommendations replace different parameters with FRP's. Steel and FRP are fundamentally different materials. One is ductile and isotropic, whereas the other is brittle and orthotropic. This paper presents experimental results of the investigation on the beams with glass fiber reinforced polymer (GFRP) reinforcement as longitudinal bars and stirrups. Total twelve beams with GFRP reinforcement were prepared and tested. The cross-section of the beams was rectangular of size 230 × 300 mm, and the total length was 2000 mm with a span of 1800 mm. The beams are designed for simply-supported conditions with the two-point load as per specified load positions for different beams. Flexural reinforcement provided is for the balanced conditions as the beams were supposed to test for shear. Two main variables, such as shear span and spacing of stirrups, were incorporated. The beams were designed as per American Concrete Institute (ACI) ACI 440.1R-15. Relation of VExp./VPred. is derived with axial stiffness, span to depth ratio, and stirrups spacing, from which it is observed that current design provisions provide overestimation, particularly at lower stirrups spacing.

Optimization for Precast Prestressed Wide-U Beams with the Least Depth (최소깊이 프리캐스트 프리스트레스트 U형보의 최적화)

  • Yul Sung-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.1 s.79
    • /
    • pp.18-26
    • /
    • 2004
  • The cost of underground work is a dominant factor to determine the total construction fee. It is generally 2 ${\~}$ 2.5 times higher than that of above ground for building with the same height. 'A new precast prestressed framing plan for underground parking building' was suggested with the beam of the least depth - U-type beams. The depth of regular rectangular reinforced concrete beam which is currently used in the underground parking of apartments could be reduced up to 12 ${\~}$ 34cm/story due to the development of a U-beams from the optimum process. Two full scale prototype U-beams were tested in this study. It was found that the Wide U-beams in the test showed higher strength than calculated nominal and design, however need to provide temporary supports to meet the flexural moment of construction load at the simply supported state before the lopping concrete hardens.

Dose Distribution of $^{11}C$ Beams for Spot Scanning Radiotherapy

  • Urakabe, Eriko;Kanai, Tatsuaki;Kanazawa, Mitsutaka;Kitagawa, Atsushi;Noda, Koji;Tomitani, Takehiro;Suda, Mitsuru;Mizuno, Hideyuki;Iseki, Yasushi
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.202-205
    • /
    • 2002
  • This paper describes the spot scanning with $^{11}$ C beams for the Heavy Ion Medical Accelerator in Chiba (HIMAC). The concave-shaped irradiation field was optimized and the dose distribution was measured by 128-ch ionization chamber. Because of the wide momentum spread inherent in $^{11}$ C beams, the dispersion caused from the beam line and the scanning magnets should be taken into account to calculate the dose distribution of $^{11}$ C beams and their irradiated field. The reconstructed dose distribution is in good agreement with the experimental results.

  • PDF

Free Vibration Analysis of Curved Beams with Thin-Walled Cross-Section (두께가 얇은 단면을 갖는 곡선보의 자유진동 해석)

  • 이병구;박광규;오상진
    • Journal of KSNVE
    • /
    • v.9 no.6
    • /
    • pp.1193-1199
    • /
    • 1999
  • This paper deals with the free vibrations of circular curved beams with thin-walled cross-section. The differential equation for the coupled flexural-torsional vibrations of such beams with warping is solved numerically to obtain natural frequencies and mode shapes. The Runge-Kutta and determinant search methods, respectively, are used to solve the governing differential equation and to compute the eigenvalues. The lowest three natural frequencies and corresponding mode shapes are calculated for the thin-walled horizontally curved beams with hinged-hinged, hinged-clamped, and clamped-clamped end constraints. A wide range of opening angle of beam, warping parameter, and two different values of slenderness ratios are considered. Numerical results are compared with existing exact and numerical solutions by other methods.

  • PDF

Effect of fatigue crack propagation on natural frequencies of system in AISI 4140 Steel

  • Bilge, Habibullah;Doruk, Emre;Findik, Fehim;Pakdil, Murat
    • Steel and Composite Structures
    • /
    • v.32 no.3
    • /
    • pp.305-312
    • /
    • 2019
  • In this study, we investigated the effect of fatigue crack propagation of the beams which have a vital importance in engineering applications, on the natural frequency of the system. Beams which have a wide range of applications, are used as fundamental structural elements in engineering structures. Therefore, early detection of any damages in these structures is of vital importance for the prevention of possible destructive damages. One of the widely used methods of early detection of damages is the vibration analysis of the structure. Hence, it is of vital importance to detect and monitor any changes in the natural frequencies of the structure. From this standpoint, in this study we experimentally investigated the effect of fatigue crack propagation on beams produced from 4140 steel, of the natural frequency of the beam. A crack was opened on the $8{\times}16{\times}500mm$ beam using a 3 mm long and 0.25 mm wide wire erosion. The beam, then, underwent 3 point bending tests at 10 Hz with a dynamic fatigue device and its natural frequencies were measured in scheduled intervals and any changes taking place on the natural frequencies of the beam were measured. This data allowed us to identify and measure the crack occurring on the beam subjected to dynamic loading, during the propagation phase. This method produced experimental data. The experimental data showed that the natural frequency of the beam decreased with the propagation of the fatigue crack on the beam.

Composite Wood-Concrete Structural Floor System with Horizontal Connectors

  • SaRibeiro, Ruy A.;SaRibeiro, Marilene G.
    • International Journal of Concrete Structures and Materials
    • /
    • v.9 no.1
    • /
    • pp.61-67
    • /
    • 2015
  • The concept of horizontal shear connection utilization on wood-concrete beams intends to be an alternative connection detail for composite wood-concrete decks. The volume of sawn-wood is over three times more expensive than concrete, in Brazil. In order to be competitive in the Brazilian market we need a composite deck with the least amount of wood and a simple and inexpensive connection detail. This research project uses medium to high density tropical hardwoods managed from the Brazilian Amazon region and construction steel rods. The beams studied are composed of a bottom layer of staggered wood boards and a top layer of concrete. The wood members are laterally nailed together to form a wide beam, and horizontal rebar connectors are installed before the concrete layer is applied on top. Two sets of wood-concrete layered beams with horizontal rebar connectors (6 and 8) were tested in third-point loading flexural bending. The initial results reveal medium composite efficiency for the beams tested. An improvement on the previously conceived connection detail (set with six connectors) for the composite wood-concrete structural floor system was achieved by the set with eight connectors. The new layout of the horizontal rebar connectors added higher composite efficiency for the beams tested. Further analysis with advanced rigorous numerical Finite Element Modeling is suggested to optimize the connection parameters. Composite wood-concrete decks can attend a large demand for pedestrian bridges, as well as residential and commercial slabs in the Brazilian Amazon.

Differential Quadrature Analysis for Vibration of Wide-Flange Curved Beams (D.Q.M.을 이용한 I-단면 곡선보의 진동해석)

  • Ji-Won Han;Ki-Jun Kang
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.3
    • /
    • pp.163-170
    • /
    • 1998
  • The differential quadrature method (D.Q.M.) is applied to computation of eigenvalues of small-amplitude free vibration for horizontally curved beams including a warping contribution. Fundamental frequencies are calculated for a single-span, curved, wide-flange beam with both ends simply supported or clamped, or simply supported-clamped end conditions. The results are compared with existing exact solutions and numerical solutions by other methods for cases in which they are available. The differential quadrature method gives good accuracy even when only a limited number of grid points is used.

  • PDF

Evaluation of Shear Capacity of Wide Beams Reinforced with GFRP and Steel Plates with Openings by Various Supporting Areas (지지부 조건에 따른 유공형 판으로 전단보강된 넓은 보의 전단성능 평가)

  • Kim, Heecheul;Ko, Myung Joon;Kim, Min Sook;Lee, Young Hak
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.3
    • /
    • pp.269-275
    • /
    • 2016
  • In this paper, shear performance of concrete wide beams was evaluated through shear failure tests. The specimens were designed to have two continuous spans with a column at the center of the wide beam. Also the specimens were reinforced with plates with openings as shear reinforcements. For the test, total eight specimens, including five specimens were reinforced with steel plates and the other three specimens were reinforced with GFRP plates were manufactured. And the shear strengths obtained from the tests were compared with ones from the equation provided by ACI 318. Support width of wide beam, support section of wide beam and shear reinforcement material were considered as variables. The results showed that the support width was proportional to the increase of shear strength. Also, regardless of material type of shear reinforcement, the shear reinforcing effect was similar when the amount of shear reinforcement was the same.