• Title/Summary/Keyword: whole section control algorithm

Search Result 5, Processing Time 0.022 seconds

A study of Large Synchronous Machine Drive using Static Frequency Converter (정지형 주파수 변환 장치를 활용한 대용량 동기 발전 전동기 운전에 관한 연구)

  • 박신현;김장목;임익헌;류호선
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.6
    • /
    • pp.496-503
    • /
    • 2003
  • SFC system has come to be used as drive large synchronous machine in many industry applications. Many papers have been presented on the control algorithm of SFC system, not the acceleration and start-up but the rated speed operation with line connection and the braking operation with regeneration which is used in the industry. This paper presents the whole section control algorithm for a large synchronous machine using SFC system. The results of experiment show that the proposed algorithm is proper and effective.

A Study of Regeneration Breaking Control Algorithm for Wounded-field Synchronous Motor Drive (대용량 동기 발전 전동기의 회생 제동 제어 알고리즘에 관한 연구)

  • Ryu, Ho-Seon;Lee, Joo-Hyun;Lim, Ik-Hun;Park, Yo-Jip;Kang, Youn-Jong;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.104-112
    • /
    • 2006
  • SFC(Static Frequence Converter)system has come to be used as drive large synchronous machine in many industry applications. Many papers have been presented on the control algorithm of SFC system, not the acceleration and start-up but the rated speed operation with line connection and the braking operation with regeneration which is used in the industry. Among this, this paper presents the regeneration breaking control algorithm for a large synchronous machine using SFC system. The results of experiment show that the proposed algorithm is proper and effective.

Design of Mutual Authentication and Grouping Protocol Based On Network Control Server Applicable to General Purpose (범용적으로 적용 가능한 네트워크제어서버 기반의 상호인증 및 그룹핑 프로토콜 설계)

  • Park, Jungoh
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.13 no.4
    • /
    • pp.13-23
    • /
    • 2017
  • In order to protect personal information and important information (confidential information, sales information, user information, etc.) in the internal network, companies and organizations apply encryption to the Server-To-Server or Server-To-Client communication section, And are experiencing difficulties due to the increasing number of known attacks and intelligent security attacks. In order to apply the existing S / W encryption technology, it is necessary to modify the application. In the financial sector, "Comprehensive Measures to Prevent the Recurrence of Personal Information Leakage in the Domestic Financial Sector" has been issued, and standard guidelines for financial computing security have been laid out, and it is required to expand the whole area of encryption to the internal network. In addition, even in environments such as U-Health and Smart Grid, which are based on the Internet of Things (IoT) environment, which is increasingly used, security requirements for each collection gateway and secure transmission of the transmitted and received data The requirements of the secure channel for the use of the standard are specified in the standard. Therefore, in this paper, we propose a secure encryption algorithm through mutual authentication and grouping for each node through H / W based Network Control Server (NCS) applicable to internal system and IoT environment provided by enterprises and organizations. We propose a protocol design that can set the channel.

A Study on Matching Method of Hull Blocks Based on Point Clouds for Error Prediction (선박 블록 정합을 위한 포인트 클라우드 기반의 오차예측 방법에 대한 연구)

  • Li, Runqi;Lee, Kyung-Ho;Lee, Jung-Min;Nam, Byeong-Wook;Kim, Dae-Seok
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.2
    • /
    • pp.123-130
    • /
    • 2016
  • With the development of fast construction mode in shipbuilding market, the demand on accuracy management of hull is becoming higher and higher in shipbuilding industry. In order to enhance production efficiency and reduce manufacturing cycle time in shipbuilding industry, it is important for shipyards to have the accuracy of ship components evaluated efficiently during the whole manufacturing cycle time. In accurate shipbuilding process, block accuracy is the key part, which has significant meaning in shortening the period of shipbuilding process, decreasing cost and improving the quality of ship. The key of block accuracy control is to create a integrate block accuracy controlling system, which makes great sense in implementing comprehensive accuracy controlling, increasing block accuracy, standardization of proceeding of accuracy controlling, realizing "zero-defect transferring" and advancing non-allowance shipbuilding. Generally, managers of accuracy control measure the vital points at section surface of block by using the heavy total station, which is inconvenient and time-consuming for measurement of vital points. In this paper, a new measurement method based on point clouds technique has been proposed. This method is to measure the 3D coordinates values of vital points at section surface of block by using 3D scanner, and then compare the measured point with design point based on ICP algorithm which has an allowable error check process that makes sure that whether or not the error between design point and measured point is within the margin of error.

Usefulness Evaluation of HRCT using Reconstruction in Chest CT (흉부CT 검사 시 HRCT 영상 재구성의 유용성)

  • Park, Sung-Min;Kim, Keung-Sik;Kang, Seong-Min;Yoo, Beong-Gyu;Lee, Ki-Bae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.13-18
    • /
    • 2015
  • Purpose : Skip the repetitive HRCT axial scan in order to reduce the exposure of patients during chest HRCT scan, Helical Scan Data into a reconstructed image, and exposure of the patient change and visually evaluate the usefulness of the HRCT images. Materials and method : Patients were enrolled in the survey are 50 people who underwent chest CT scans of patients who presented to the hospital from January 2015 to March 2015. 50 people surveyed 22 people men and 28 people women people showed an average distribution of 30 to 80 years age was 48 years. 50 patients to Somatom Sensation 64 ch (Siemens) model with 120 kVp tube voltage to a reference mAs tube current to mAs (Care dose, Siemens) as a whole, including the lungs and the chest CT scan was performed. Scan upon each patient CARE dose 4D (Automatic exposure control, Siemens Medical Solution Erlangen, Germany) was to maintain the proper radiation dose scan every cross-section through a device that automatically adjusts the tube current of. CT scan is the rotation time of the Tube slice collimation, slice width 0.6 mm, pitch factor was made under the terms of 1.4. CT scan obtained after the raw data (raw data) to the upper surface of the axial images and coronal images for each slice thickness 1 mm, 5 mm intervals in the high spatial frequency calculation method (hight spatial resolution algorithm, B60 sharp) was the use of the lung window center -500 HU, windows were reconstructed into images in the interval -1000 HU to see. Result : 1. Measure the total value of DLP 50 patients who proceed to chest CT group A (Helical Scan after scan performed with HRCT) and group B (Helical Scan after the HR image reconstruction to the original data) compared with the group divided, analysis As a result of the age, but show little difference for each age group it had a decreased average dose of about 9%. 2. A Radiation read the results of the two Radiologist and a doctor upper lobe and middle lobe of the lung takes effect the visual evaluation is not a big difference between the two images both, depending on the age of the patient, especially if the blood vessels of the lower lobe (A: 3.4, B: 4.6) and bronchi(A: 3.8, B4.7) image shake caused by breathing in anxiety (blurring lead) to the original data (raw data) showed that the reconstructed image is been more useful in diagnostic terms. Conclusion : Scan was confirmed a continuous, rapid motion video to get Helical scan is much lower lobe lung reduction in visual blurring, Helical scan data to not repeat the examination by obtaining HRCT images reorganization reduced the exposure of the patient.

  • PDF