• Title/Summary/Keyword: white-light scanning

Search Result 105, Processing Time 0.02 seconds

AN EXPERIMENTAL STUDY OF NEWLY DESIGNED IMPLANT WITH RBM SURFACE IN THE RABBIT TIBIA : RESONANCE FREQUENCY ANALYSIS AND REMOVAL TORQUE STUDY

  • Won Mi-Kyoung;Park Chan-Jin;Chang Kyoung-Soo;Kim Chang-Whe;Kim Yung-Soo;Isa Zakiahbt Mohd;Ariffin Yusnidar Tajul
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.6
    • /
    • pp.720-731
    • /
    • 2003
  • Statement of problem. The importance of fixture design and surface treatment. Purpose. The clinical success of dental in plants is affected by many factors such like as degree of osseointegration, the effective load dispersion for the prostheses, and a lot of attempts have been made to overcome the difficulties. In this study, efforts were made to find the possibility of clinical acceptance of the dental implants of newly designed surface and resorbable blast media surcace. Materials and methods. In this study, two groups of custom-made, screw-shaped implants were prepared. The first with the consisting of Branemark clone design and the other with the new design. These implants were divided into four groups according to the kinds of surface treatment. Four implants($AVANA^{(R)}$, Osstem, Busan, Korea)of each group were installed in twenty rabbits. Group A was consisted of Branemark done implant left as machined, Group B with Branemark clone implants with RBM(Resorbable blast media) surface, Group C with newly designed implants left as machined and Group D with newly designed implants with RBM surface. One of the twenty rabbits died from inflammation and the observation was made for six weeks. Specimens from four groups were observed using scanning electron microscopy with 40, 100, 1000 magnification power and microsurface structures were measured by white-light scanning interferometry for three dimensional surface roughness measurements(Accura $2000^{(R)}$, Intek-Plus, Korea.). Removal torque was measured in 17 rabbits using digital torque gauge(MGT 12R, Mark-10 corp., NY, U.S.A.) immediately after the sacrifice and two rabbits were used for the histologic preparation(EXAKT $310^{(R)}$, Heraeus Kulzer, wehrheim, Germany) of specimens and observed under light microscope. Resonance frequency measurement($Osstell^{(R)}$) was taken with the 19 rabbits at the beginning of the implant fixation and immediately after the sacrifice. Results. Following results were taken from the experiment. 1. The surface of the RBM implants as seen with SEM had rough and irregular pattern with reticular formation compared to that of fumed specimens showing different surface topographies. 2. The newly designed implant with RBM surface had high removal torque value among four groups with no statistical significance. The average removal torque was $49.95{\pm}6.70Ncm$ in Group A, $51.15{\pm}4.40Ncm$ in Group B, $50.78{\pm}9.37Ncm$ in Group C, $51.09{\pm}4.69Ncm$ in Group D. 3. The RFA values were $70.8{\pm}4.3Hz$ in Group A, $71.8{\pm}3.1Hz$ in Group B, $70.9{\pm}2.5Hz$, $72.7{\pm}2.5Hz$ in Group D. Higher values were noted in the groups which had surface treatment compared to the untreated groups with no statistical significance. 4. The results from the histomorphometric evaluation showed a mean percentage of bone-to-implant contact of $45{\pm}0.5%$ in Group A, $55{\pm}3%$ in Group B, $49.5{\pm}0.5%$ in Group C, and $55{\pm}3%$ in Group D. Quite amount of newly formed bone were observed at the surface RBM-treated implants in bone marrow space.

The Tissues and Blood Components of Opsariichthys uncirostris amurensis in the Muddy Water Area (탁수역에 서식하는 끄리의 조직과 혈액 성분의 변화)

  • Shin, Myung-Ja;Lee, Jong-Eun;Seo, Eul-Won
    • Journal of Life Science
    • /
    • v.17 no.1 s.81
    • /
    • pp.97-104
    • /
    • 2007
  • Present study aims to investigate the effect of muddy water on gill and kidney tissues and blood components of Opsariichthys uncirostris amurensis in Imha reservoir. As a result of observing the gill tissues in muddy water with light and scanning electron microscopes, the edema, the exfoliation of epithelial cells and fusion of the secondary lamellae were observed. The space between gill lamellae was irregular, and a lots of muddy debris around the secondary lamellae were observed. In case of kidney tissues, the size of glomerulus was smaller and thickness of basal membrane was broader and the empty space in Bowman's capsule was wider than those of the control. The blood cells of O. uncirostris amurensis in muddy water were increased in number. Of the white blood cells, acidophilic granulocytes were highly distributed, and the shapes were irregular. Among the plasma components, the concentration of TP, ALB, A/G ratio, TG, CHOL, and AST were low, whereas that of the inorganic materials was high. Based on the above results, it is considered that muddy water possibly involves in the decrease of respiratory and excretory rates, giving rise to secondary lesion of tissues.

Optical Properties of MgMoO4:Dy3+,Eu3+ Phosphors Prepared with Different Eu3+ Molar Ratios (Eu3+ 이온의 몰 비 변화에 따른 MgMoO4:Dy3+,Eu3+ 형광체의 광학 특성)

  • Kim, Jung Dae;Cho, Shinho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.3
    • /
    • pp.186-191
    • /
    • 2016
  • The effects of $Eu^{3+}$ doping on the structural, morphological, and optical properties of $MgMoO_4:Dy^{3+},Eu^{3+}$ phosphors prepared by solid-state reaction technique were investigated. XRD patterns exhibited that all the synthesized phosphors showed a monoclinic system with a dominant (220) diffraction peak, irrespective of the content of $Eu^{3+}$ ions. The surface morphology of $MgMoO_4:Dy^{3+},Eu^{3+}$ phosphors was studied using scanning electron microscopy and the grains showed a tendency to agglomerate as the content of $Eu^{3+}$ ions increased. The excitation spectra of the phosphor powders were composed of a strong charge transfer band centered at 294 nm in the range of 230~340 nm and two intense peaks at 354 and 389 nm, respectively, arising from the $^6H_{15/2}{\rightarrow}^6P_{7/2}$ and $^6H_{15/2}{\rightarrow}^4M_{21/2}$ transitions of $Dy^{3+}$ ions. The emission spectra of the $Mg_{0.85}MoO_4$:10 mol% $Dy^{3+}$ phosphors without incorporating $Eu^{3+}$ ions revealed a strong yellow band centered at 573 nm resulting from the $^4F_{9/2}{\rightarrow}^6H_{13/2}$ transition of $Dy^{3+}$. As the content of $Eu^{3+}$ was increased, the intensity of the yellow emission was gradually decreased, while that of red emission band located at 614 nm began to appear, approached a maximum value at 10 mol%, and then decreased at 15 mol% of $Eu^{3+}$. These results indicated that white light emission could be achieved by controlling the contents of the $Dy^{3+}$ and $Eu^{3+}$ ions incorporated into the $MgMoO_4$ host crystal.

Photoeletrochemical Properties of α-Fe2O3 Film Deposited on ITO Prepared by Cathodic Electrodeposition (음극전착법을 이용한 α-Fe2O3 막의 광전기화학적특성)

  • 이은호;주오심;정광덕;최승철
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.9
    • /
    • pp.842-848
    • /
    • 2003
  • Semiconducting $\alpha$-Fe$_2$O$_3$ film was prepared by the cathodic electrodeposition method on Indium Tin Oxide (ITO) substrate for photoelectrochemical cell application. After heat treatment at 50$0^{\circ}C$, the phase was changed from Fe to $\alpha$-Fe$_2$O$_3$. The phase, morphology, absorbance, and photocurrent density (A/$\textrm{cm}^2$) of the film depended on the preparation conditions: deposition time, applied voltage, and the duration of heat treatment. The $\alpha$-Fe$_2$O$_3$ film was characterized by X-Ray Diffractometer (XRD), Scanning Electron Microscope (SEM), and UV -Visible Spectrophotometer. The stability of the $\alpha$-Fe$_2$O$_3$ film in aqueous solution was tested at zero bias potential under the white-light source of 100 mW/$\textrm{cm}^2$. The apparent grain size of the films formed at -2.0 V was larger than that grown at -2.5 V. The $\alpha$-Fe$_2$O$_3$ film deposited at -2.0 V for 180 s and heat-treated at 50$0^{\circ}C$ for 1 h showed the predominant photocurrent of 834$\mu$A/$\textrm{cm}^2$.

Experimental brush wear pattern and cariostatic effect of Biscover (Biscover의 잇솔질에 따른 마모양상과 항우식 효과)

  • Oh, Eun-Ju;Park, Song-Soo;Jang, Mun-Ju;Jeon, Young-Mi;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.38 no.3
    • /
    • pp.214-222
    • /
    • 2008
  • Objective: The aim of this study was to investigate the experimental brush wear pattern of a light cured surface sealant, Biscover (Bisco, Schaumburg, IL), and to evaluate its cariostatic effect. Methods: Caries-free human premolars were used for the Biscover coating group (n = 90) and the control group (n = 10). The Biscover coating group was randomly assigned to nine subgroups of 10 each and the control group was assigned to two subgroups of 5 each according to the number of brushing strokes. An experimental 3-body wear test was conducted under different strokes of wear test. Tooth-brushing was accomplished with movement of each brush head set at a frequency of 100 rpm under a force of 1.5N, Surface roughness was tested before, and after Biscover coating, and after brushing. Then, each of the 10 teeth of both groups were placed in artificial caries inducing solution for 7 days. All tooth surfaces were assessed using scanning electron microscopy. Results: Biscover coated surfaces showed a smoother texture than enamel surfaces. The roughness was increased after experimental brushing and after 10,800 brushing strokes, the whole layer of Biscover wore out. However, teeth in the Biscover coating group had a cariostatic effect in cariogenic conditions. Conclusions: We suggest that white lesions in orthodontic patients can be suppressed by topical applications of Biscover.