• 제목/요약/키워드: white-light LED

검색결과 403건 처리시간 0.032초

Influence of Stocking Density with Different Light System on the Growth Performance and Behavior in Broiler Chickens

  • Lim, Chun Ik;Rana, Md Masud;Choi, Il Bok;Ryu, Kyeong Seon
    • 한국가금학회지
    • /
    • 제46권4호
    • /
    • pp.297-304
    • /
    • 2019
  • This study evaluated the effects of stocking density on performance and behavioral activities of 35-day-old broilers in relation to incandescent white bulb (IB) light and LED yellow and white light. A total of 1,650 day-old chicks were weighed and randomly allocated into six treatment groups in a 2 × 3 factorial arrangement based on stocking density (14 birds m-2 and 22 birds m-2) and color of lights (IB; monochromatic LED yellow and white light) with five replicates for each treatment. The results showed that final body weight, weight gain and feed conversion of broilers were improved at a stocking density of 14 birds m-2 with exposure to LED lights. Similarly, broilers spent more time exhibiting inactive behavior (e.g. standing) and active behaviors (e.g. walking and walking plus pecking) under 14 birds m-2 with exposure to lights as compared that of other treatment groups. Regarding a stocking density of 22 birds m-2, broilers performance traits were negatively affected and also activities were less. The performance of broilers was not significantly altered for the main factor of different lights but broilers were less inactive (e.g less time spent sitting plus standing) and more time spent active behavior in walking under IB light than LED light. Thus, we concluded that a stocking density 14 birds m-2 with exposure to LED light significantly improved broiler performance and behavioral activity and these conditions could therefore improve the overall welfare of farmed chickens.

광 강도 제어에 따른 LED의 광질에 관한 연구 (A Study on Light Quality of LED for Control of Light Intensity)

  • 박상희;안준철;허정욱;최한고;최성대
    • 한국기계가공학회지
    • /
    • 제11권6호
    • /
    • pp.175-182
    • /
    • 2012
  • Light characteristics of the monochromatic red(R), blue(B), green(G) and white(W) and the mixed LED (B-R LED) were investigated by light control a Spectrometer-MMS1 and an illuminometer. The power consumption of each LED was 1W and R LED has five wavelength bands(600nm, 640nm, 660nm, 680nm, 750nm). The light intensity of each LED was changed in a range 10~100%. As a results, the wavelength and the spectrum distribution of R LED increase with increasing light intensity but the wavelength of B, G, W LED decreases. It was found that illumination of each mononochromatic and B-R LED increases linearly with increasing light intensity. It was confirmed that the illumination intensity of R-B light has greater values than those obtained by monochromatic light at the same conditions.

백색광과 청색 LED 방식의 광학스캐너로 채득된 디지털 모형의 비교분석 (Comparative analysis on digital models obtained by white light and blue LED optical scanners)

  • 최석순;김재홍;김지환
    • 대한치과기공학회지
    • /
    • 제36권1호
    • /
    • pp.17-23
    • /
    • 2014
  • Purpose: The purpose of this study was to analyze and compare the relative accuracy of digitized stone models of lower full arch, using two different scanning system. Methods: Replica stone models(N=20) were produced from lower arch acrylic model. Twenty digital models were made with the white light and blue LED($Medit^{(R)}$, Korea) scanner. Two-dimensional distance between the landmarks were measured on the Delcam $CopyCAD^{(R)}$(Delcam plc, UK). Independent samples t-test was applied for comparison of the groups. All statistical analyses were performed using the SPSS software package(Statistical Package for Social Sciences for Windows, version 12.0). Results: The absolute disagreement between measurements made directly on the two different scanner-based dental digital models was 0.02~0.04mm, and was not statistically significant(P>0.05). Conclusion: The precision of the blue LED optical scanner was comparable with the digitization device, and relative accuracy was similar. However, there still is room for improvement and further standardization of dental CAD technologies.

과채류 접목 시 균일한 접수와 대목 생산을 위한 백색 LED의 적용 (Application of White Light Emitting Diodes to Produce Uniform Scions and Rootstocks for Grafted Fruit Vegetable Transplants)

  • 황현승;전창후
    • 생물환경조절학회지
    • /
    • 제31권1호
    • /
    • pp.14-21
    • /
    • 2022
  • 광질은 묘의 형태를 조절하는 중요한 환경 요인 중 하나이다. warm-white와 cool-white LED의 칩에 비율이 다른 bar type를 제작하여, 백색 LED의 광질에 따른 묘의 생육을 조사하고자 연구를 수행하였다. 오이, 토마토 및 수박의 접수와 대목의 종자를 파종하여, LED를 광원으로 하는 식물공장에서 재배하였다. 처리구는 W1C0(warm-white 단독), W1C1 (warm-white:cool-white=1:1), W3C1 (warm-white:cool-white=3:1), W5C2 (warm-white:cool-white=5:2)이다. 모든 처리구에서 W1C1 처리구에서 재배한 묘목의 배축장이 가장 짧았으며, W1C0에서 재배된 묘목의 배축장이 가장 길었다. 수박 접수, 수박 대목, 그리고 토마토 대목의 배축장은 W1C1, W3C1, W5C2, W1C0 순이었으며, 이는 cool-white의 비율이 높은 순서와 같았다. 토마토 접수는 각각 W1C0과 W3C1에서 첫 번째와 두 번째로 배축이 길었고 W5C2와 W1C1에서 가장 짧았으며, 통계적 차이는 없었다. 경경은 토마토 접수, 토마토 대목 및 수박 대목을 제외하고는 큰 차이가 없었다. 토마토 접수, 토마토 대목 및 수박 대목의 줄기 직경은 W1C0에서 가장 굵었다. 오이, 수박의 접수와 대목의 지상부 생체중과 오이 접수의 지하부 생체중은 W1C1에서 가장 작았다. 본 연구를 통해 LED 광원의 다양한 비율은 묘목의 배축 신장에 크게 영향을 미치는 것을 확인하였다.

트랜스퍼 몰딩 방식을 이용한 고 색 균일성 특성을 가지는 백색 LED 램프 (Development of White LED Lamp Having High Color Uniformity With Transfer Molding Technology)

  • 유순재;김도형
    • 한국전기전자재료학회논문지
    • /
    • 제23권1호
    • /
    • pp.38-41
    • /
    • 2010
  • Compared to conventional molding technology, the color uniformity of light direction emitted from LED is improved with PCB type lead frame technology in which metal thin film is used and transfer molding technology which makes the density of phosphor uniform by manufacturing high density LED lamp. The light efficiency and the color uniformity of the LED are improved by molding the phosphor layer outside of chip and controlling the thickness of the phosphor layer. CIE x,y difference of LED in major axis is also improved uniformly from 0 to 90 degrees.

수조에서 여러 가지 색광에 대한 멸치의 반응 연구 (The study on the Anchovy's (Engraulis japonica) reaction to several light colors in a tank)

  • 배봉성;조삼광;차봉진;박성욱;안희춘
    • 수산해양기술연구
    • /
    • 제47권4호
    • /
    • pp.327-337
    • /
    • 2011
  • This study was conducted to develop energy-efficient LED lamps with an excellent fishing performance for an anchovy scoop net by comparing the functions of 6 different lamps- incandescent, blue LED, green LED, white LED, yellow LED and red LED lamp. We used incandescent and red LED lamps only for the initial test and then excluded because those showed the lowest herding capacity. According to the result, yellow LED showed lower herding capacity in comparison with the blue, green and white one. Although the herding performance of the blue, green and white LED was similar in almost tests, herding speed to the each light was different. The anchovies were gathered into the blue LED as the speed of 39.88cm/s that was the fastest. Green LED was the second as the speed of 33.28cm/s. White LED was the slowest as the speed of 26.73cm/s. We will have field tests because we found the result that yellow LED's herding performance was better than green LED's for 5 seconds comparing after starting in some tests.

Performance Analysis of Optical Path Difference on Visible Light Communication System for Intelligent Transport Systems

  • 최재혁;이계산;차재상;김진영
    • 한국ITS학회 논문지
    • /
    • 제8권5호
    • /
    • pp.114-120
    • /
    • 2009
  • In outdoor visible light communication channels and LED road illumination communications for the intelligent transport systems (ITS), inter symbol interference (ISI) due to multipath propagation prevents high data rate transmission. Indoor wireless optical communication systems utilizing white LED lights and on the road illumination have been studying about it. Generally, plural lights are installed in room and considered to the traffic information system using existing LED traffic lights. Therefore, their optical path difference must be considered. In this paper, the influence of an optical path difference has been investigated and two approaches against this problem are introduced. One uses on-off keying, return-to-zero (OOK-RZ) coding and the other uses optical orthogonal frequency division multiplexing(OFDM).

  • PDF

사파장 백색 발광 다이오드의 발광 특성 (Luminescent Properties of Four-Band White Light Emitting Diodes)

  • 허영덕;임수미
    • 대한화학회지
    • /
    • 제47권4호
    • /
    • pp.370-375
    • /
    • 2003
  • 보라색 발광 다이오드에 의해 여기되어 청색, 녹색, 적색을 발광하는 형광체로 각각 $BaMg_2Al_16O_27:Eu,\SrGa_2S_4:Eu$, ZnCdS:Ag,Cl 형광체를 선택하였다. 보라색 발광 다이오드의 발광에서 형광체에 의해서 완전히 흡수되지 않고 나오는 보라색 발광과 $BaMg_2Al_16O_27:Eu,\SrGa_2S_4:Eu$, ZnCdS:Ag,Cl 형광체에서 나오는 청색, 녹색, 적색 발광을 조합하여 사파장 백색 발광 다이오드를 만들었다. 사파장 백색 발광 다이오드의 발광 특성을 확인하였다.

식물공장에서 적색, 청색, 백색 및 원적색 LED 처리에 따른 고추냉이의 생육반응 (Effects of Red, Blue, White, and Far-red LED Source on Growth Responses of Wasabia japonica Seedlings in Plant Factory)

  • 김해란;유영한
    • 원예과학기술지
    • /
    • 제31권4호
    • /
    • pp.415-422
    • /
    • 2013
  • 본 연구는 식물공장용 LED 챔버 시스템에서 고추냉이의 생육반응에 미치는 LED 광원 및 광질의 영향을 알아보기 위해 적색, 청색, 백색 그리고 원적색광의 단일 및 혼합처리, 적색광과 청색광의 비율 그리고 duty비 등을 다양하게 처리하여 수행하였다. 고추냉이의 생육반응은 적색 + 청색 혼합광에서 가장 높았고, 단일광 조건에서는 청색광보다 적색광 하에서 식물체 생물량이 높았다. 고추냉이의 식물체 생물량과 분얼수는 적색과 청색광의 비율이 1:1인 조건에서 가장 높았다. 적색과 청색광을 혼합하여 처리 시 고추냉이의 생육반응은 duty비가 100%일 때 높은 반면, 적색과 청색광에 백색광을 첨가하여 처리 하였을 때는 duty비가 가장 낮은 97%에서 높았다. 엽면적과 잎건중량은 적색광에서 가장 높은 반면, 비엽면적은 청색광에서 가장 높았다. 적색과 청색 혼합광에서 엽면적과 잎건중량은 적색광의 비율이 높거나, duty비가 낮을수록 증가하였고, 백색광을 첨가한 조건에서는 duty비가 높을수록 증가했다. 이상의 결과를 종합해보면, 고추냉이는 단일광을 처리하는 것보다 적색과 청색광을 혼합하여 처리해 주거나, 청색광보다 적색광의 비율을 더 높여주는 것이 고추냉이의 생육 및 품질을 향상시켜 줄것으로 판단된다.

인광성 백색 LED의 가시광 통신 변조 대역폭 향상을 위한 등화기 구현 (Implementation of the Equalization Circuits for High Bandwidth Visible Light Communications Using Phosphorescent White LED)

  • 손경락
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권4호
    • /
    • pp.473-477
    • /
    • 2015
  • 본 논문에서는 인광물질을 포함하는 조명용 백색 LED를 이용한 가시광 통신 시스템의 변조 대역폭을 늘리기 위한 등화기를 설계하고 실험적으로 결과를 보였다. 등화기의 성능을 분석하기 위한 해석적 방법으로 회로 시뮬레이터인 PSpice를 이용하였다. 등화기는 저항과 커패시터를 이용한 수동필터와 증폭기를 이용한 능동필터의 조합으로 구성하였다. 등화기를 수신단에 적용함으로써 3.5 MHz 부근의 인광성 백색 LED 변조 대역폭이 청색 광학필터를 사용하지 않고도 25 MHz 까지 확장되었다. 상용화된 라운드형 백색 LED 1개와 PIN형 광 다이오드 1개를 이용하여 구현한 가시광 통신 시스템에서 진폭편이변조 방식으로 변조된 LED의 가시광 신호는 1미터 거리에서 35 Mbit/s 데이터 전송률을 보였다. 이때의 비트 에러율은 $7.6{\times}10^{-4}$이었으며 이는 순방향 오류 정정의 한계인 $3.8{\times}10^{-3}$ 이하를 만족하였다.