• Title/Summary/Keyword: wet test

Search Result 786, Processing Time 0.032 seconds

Unsteady Wet Steam Flow Measurements in a Low-Pressure Test Steam Turbine

  • Duan, Chongfei;Ishibashi, Koji;Senoo, Shigeki;Bosdas, Ilias;Mansour, Michel;Kalfas, Anestis I.;Abhari, Reza S.
    • International Journal of Fluid Machinery and Systems
    • /
    • v.9 no.1
    • /
    • pp.85-94
    • /
    • 2016
  • An experimental study is conducted for unsteady wet steam flow in a four-stage low-pressure test steam turbine. The measurements are carried out at outlets of the last two stages by using a newly developed fast response aerodynamic probe. This FRAP-HTH probe (Fast Response Aerodynamic Probe - High Temperature Heated) has a miniature high-power cartridge heater with an active control system to heat the probe tip, allowing it to be applied to wet steam measurements. The phase-locked average results obtained with a sampling frequency of 200 kHz clarify the flow characteristics, such as the blade wakes and secondary vortexes, downstream from the individual rotational blades in the wet steam environment.

Evaluate the Concrete mix by Type Accelerated Corrosion Test and Chloride Penetration Analysis with Artificial Seawater Cyclic Wet and Dry Condition (인공해수 건습반복조건에 따른 콘크리트배합별 부식촉진시험법과 염화물 침투해석평가)

  • Park, Sang-Soon;Kim, Min-Wook
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.3
    • /
    • pp.211-218
    • /
    • 2013
  • Cyclic wet and dry conditions in the marine environment structures corrosion is known to be the fastest rising. For that reason, accelerated corrosion test methods for the reproduction of tidal environment has been actively conducted. However, many studies have estimated threshold value for steel corrosion or concentrated in chloride penetration analysis. In this study, cyclic wet and dry conditions to reproduce the structure of the environment in accelerated corrosion and chloride penetration test analysis was performed. Corrosion was determined by the result of reinforcement corrosion monitoring based on galvanic potential measurement and half-cell potential method. Accelerated corrosion test results for each formulation was different corrosion periods, the order OPC> FA> BS> High-strength concrete. FEM durability interpretation program DuCOM was conducted under the same conditions as in accelerated corrosion test. The experimental RCPT tests demonstrated the validity of the result.

A Study on the Measurement of Water Content in Hydrogel Contact Lens by Gravimetric Method (중량측정법에 의한 하이드로젤 콘택트렌즈의 함수율 측정에 관한 연구)

  • Kim, Tae-Hun;Ye, Ki-Hun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.59-63
    • /
    • 2008
  • Purpose: The purpose of this study is to understand a relation of water content measurement with two different method, water removal method and dry method. Methods: 72 hydrogel contact lens containing various water content (ranged from 47% to 58%) were measured by the gravimetric method at 20$^{\circ}C$and 21% of the humidity. We weighed the dried test specimen at room temperature for 30 min after cooling. Results: In dry blotting method, the water content was measured to 47.43${\pm}$8.48%. The water contents was measured to 48.15${\pm}$8.36% with wet blotting condition. It was found that wet blotting method showed the higher water content of about 7% than dry blotting method. In water content with two dry methods, each of results was measured by 47.89${\pm}$8.06% and 49.56${\pm}$7.06%. In case of microwave method, the water content was measured significantly higher water content of about 1.67% than vacuum oven method. However, no statistical difference was found (p>0.05). Conclusions: In water removal method (Dry blotting method and Wet blotting method) to weigh hydrated test specimen, wet blotting method showed significantly higher water content than dry blotting method. Also in case of dry methods (vacuum oven and microwave) to weigh dry test specimen, water content of microwave method showed higher water content than vacuum oven method, but it should be noted that microwave oven method must be used carefully to measure accurateness on the specimen position and wave power.

  • PDF

The Whole Effluent Toxicity Tests of Wastewater Discharged from Various Wastewater Treatment Plants and Their Impact Analyses on Biological Component (폐수처리장의 전 방류수 독성 평가 및 방류수 배출하천의 생지표도 영향분석)

  • Ra, Jin-Sung;Kim, Sang-Don;An, Kwang-Guk;Chang, Nam-Ik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.353-361
    • /
    • 2005
  • In this study, we performed whole effluent toxicity(WET) test and compared the biological component analyses tests for some streams into which wastewater treatment plant effluents are discharged. The test procedures for the WET test and the biological component analysis were conducted according to U.S. EPA guidelines and the Ohio EPA wading method. The WET tests based on the test species of D. manga and S. capricornutum All treatment plants showed a S. capricornutum toxicity, and at 7 sites, except A and J, we could observe a D. magna toxicity. The highest toxicity was observed at site D and this were followed by E and F. The biological component analyses applied to the effluent discharged stream. We found that total species were low at sites C1, D1 and J1 and the low number of total individuals were observed at sites A1, C1, E1, H1, and J1 compared to the controls and other sites. The species richness was low at sites A1, B1, C1, D1, and J1. The species change was evident at site D(D1) and the tolerant species was predominant. The biological analyses and WET tests suggested that the effluents resulted in massive ecosystem impact.

Braking Characteristics of Friction Disk made of Carbon Paper for Wet-type Multiple Disk Brakes of Crane Turning Decelerator (크레인 선회감속기의 습식 다판 브레이크를 위한 카본 페이퍼 마찰 디스크의 제동 특성)

  • Cho, Yonsang;Bae, Myongho
    • Tribology and Lubricants
    • /
    • v.28 no.3
    • /
    • pp.112-116
    • /
    • 2012
  • wet-type multiple disk brakes are very important parts of turning decelerator for deck crane, because they are advanced in durability and braking power, and can be designed compactly. Thus, we designed and made wet-type multiple disk brakes of turning decelerator for deck crane to be localization of these imported all. In this study, wet multiple disk brakes were made a comparative test with the 2 types materials of friction disk by the SAE No.2 dynamometer. The friction characteristics were measured and analyzed to decide a suitable material as wear depth of friction disk and dynamic and static friction coefficient.

SU/PG Model Evaluation for river dynamics (자연하천 해석을 위한 SU/PG 모형의 개발)

  • Han, Kun Yeun;Park, Kyung Ok;Baek, Chang Hyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.1331-1334
    • /
    • 2004
  • Wet/Dry phenomena typically incorporate a number of complex flow mechanism. These include a momentum transfer and turbulent mixing caused by the delivery of water. However currently available one dimensional schemes applicable to wet/dry process cannot effectively simulate such process. Two dimensional finite element model, SU/PG, is used to simulate complex flow in this study. The Wetted Area Method in SU/PG allows elements to transition gradually between wet and dry states. The model is applicable to a straight river reach with irregular bathymetry. Wet/dry calculation using the wetted area method can simulate simple numerical test. The computed results of velocity vectors and water depth agree with those of observed. The methodology Presented in this study will contributed to two-dimensional wet/dry analysis in a river in this country.

  • PDF

Evaluation of Hydrogen Sulfide Corrosion Inhibitors for Wet Gas Pipeline Steel

  • Huy, Vu Dinh;Thoa, Nguyen Thi Phuong;Phong, Tran Quoc;Hoang, Nguyen Thai
    • Corrosion Science and Technology
    • /
    • v.4 no.3
    • /
    • pp.95-99
    • /
    • 2005
  • Wheel test and potentiodynamic polarization methods were used to evaluate the relative effectiveness of some hydrogen sulfide corrosion inhibitors for the wet gas pipeline API 5L grade X 65 steel. Five commercially corrosion inhibitors have been studied in the deoxygenated produced water solutions containing 10 ppm and 100 ppm of hydrogen sulfide. Based on the experiment results the steel corrosion inhibition mechanism in discussed and two most effective corrosion inhibitors are selected.

A Study on Fundamental Performance of Epoxy Resin Mortar Mixed Special Cement for Concrete Surface Control (특수시멘트 혼입 에폭시 수지계 콘크리트용 바탕조정재의 기초물성에 관한연구)

  • 최성민;김용현;황원주;오상근
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10c
    • /
    • pp.145-150
    • /
    • 1998
  • This study deals with the effect on performance of epoxy resign mortar mixed special cement for surface control and maintenance of aging concrete construction. The test of main property of epoxy resign in this study are the evaluation on the adhesive strength between substrate and epoxy resign mortar under the environment of wet or concrete substrate surface. We gained the test results of good adhesive strength over 15 kgf/$\textrm{cm}^2$ under the wet and dry condition of concrete surface.

  • PDF

Wet Environmental and Mechanical Characteristics for Polyethylene-based Insulating Materials (Polyethylene 계열 절연재료의 환경적·기계적 특성)

  • Song, Woo-Chang;Choi, Won-Seok;Park, Ha-Yong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.2
    • /
    • pp.119-123
    • /
    • 2014
  • In this study, four kinds of specimens of PE(polyethylene)-based insulating materials were prepared for selecting the optimum insulation materials in a wet environment. The specimens were tested by various methods, the anti tracking test, the transmittance test in the water vapor transmittance(WVT) and the abrasion resistive test, etc. The HDPE(high-density polyethylene) specimen was showed excellent property in the tracking resistance test and the lowest transmittance in water vapor transmittance test. In the abrasion resistive test, the LLDPE(linear low-density polyethylene) and MDPE(medium-density Polyethylene) were showed excellent mechanical properties. The value of cut-through resistance for MDPE and HDPE were superior to that for LLDPE and LDPE(low-density polyethylene).

Uncertainty Analysis of Test Method for Heat Recovery Ventilators (폐열회수 환기유닛의 인증시험 방법에 대한 오차분석)

  • Han, H.;Choo, Youn-Bok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.423-428
    • /
    • 2006
  • Twenty nine HRV models have been tested for last two years since the attestation system has been started by KARSE. It is the objective of the present study to analyze the performance test results. Uncertainty analysis has been conducted to find the effects of measured variables on the uncertainties of test results. The uncertainty of enthalpy is found to be affected by the uncertainty of wet bulb temperature significantly, but not by that of dry bulb temperature for the present range of parameters. The uncertainty of effective enthalpy efficiency is calculated to be 6%P for the cooling condition, and 3%P for the heating condition approximately. In order to reduce the uncertainty of the test results, the uncertainty of wet bulb temperature should be minimized and the indoor/outdoor test conditions should be modified so as to increase the enthalpy difference.

  • PDF