• Title/Summary/Keyword: welded deformed wire fabric

Search Result 5, Processing Time 0.022 seconds

The Flexural Behavior including Ductility of Half Precast Concrete Slab with Welded Deformed Wire Fabric (용접철망을 사용한 반두께 P.C.슬래브의 휨 및 연성거동)

  • 이광수;최종수;조민형;신성우
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.4
    • /
    • pp.153-160
    • /
    • 1994
  • Ten Half precast concrete slabs reinforced with welded deformed wire fabric were tested under two concentrated loads to investigate the flexural moment and ductile capacity. The test variables were the compressive strength of topping concrete, quantitative roughness, and reinforcernent ratio. The effects of each test variables were studied separately. Test results were as followings. The ultimate strength design method is applicable to predict flexural strength for Half P.C. concrete slab with welded deformed wire fabric and quantitative roughness. It is proper to consider 0.0035 strain ;is yielding stress of the welded deformed wire fabric. The ductility index of Half precast concrete slab with welded deformed wire fabric showed lower value. Therefore to enhance the ductility capacity the normal defomed bar should be used with the welded deformed wire fabric for the longitudinal reinforcement.

Inplane Flexural Behavior of Concrete Walls Reinforced by Welded Wire Fabric (용접철망 콘크리트 벽체의 면내 휨거동 연구)

  • Kim, Dae-Joong;Kim, Woo;Yang, Ji-Soo;Yoon, Young-Ho;Chung, Lan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.04a
    • /
    • pp.136-141
    • /
    • 1993
  • 8 Wall specimens (1/2 scaled) used welded wire fabric (Ф=6mm) and ordinary deformed reinforcement(D6) of which their ultimate tensile strength were almost same were tested to investigate the inplane-flexural behavior. Test results show that : 1. The wall strength with welded wire fabric was 20% less than that with deformed bar. 2. The wall ductility ratio of welded wire fabric was 1/3 times than that of deformed bar, approximately. 3. It is recommened that lap splice of welded sire fabric should be avoided in critical fracture zone.

  • PDF

An Experimental Study on the Structural Behavior of Reinforced Concrete Continuous Deep Beams Using Welded Deformed Wire Fabric as Shear Reinforcements (이형 용접철망을 전단철근으로 사용한 철근콘크리트 연속 깊은 보의 구조적 거동에 대한 실험적 연구)

  • Yang Keun-Hyeok;Chung Heon-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.95-98
    • /
    • 2005
  • The objective of this experimental study was to understand the structural behavior of reinforced concrete continuous deep beams with welded deformed wire fabric(WWF) as shear reinforcement. The structural behavior of deep beams reinforced with WWF was compared with that of deep beams reinforced with orthogonal shear reinforcement which had standard anchorage corresponding to ACI 318-02. Test results showed that the load transferring capacity and the control of splitting cracks in the strut of WWF were almost as effective as those of orthogonal shear reinforcement with standard anchorage.

  • PDF

An Experimental Study on Flexural Behavior of One-Way Concrete Slabs Using Structural Welded Wire-Fabric (구조화 용접철강을 사용한 일방향 슬래브의 휨 거동에 관한 실험적 연구)

  • 허갑수;윤영호;양지수;김석중;정헌수
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.2
    • /
    • pp.169-179
    • /
    • 1994
  • Recently the construction of residential buildings faces many difficulties due to the shortage of building materials and works. Simplifying the stage of processing and assembling reinforcing rods and increasing the efficiency of them in reinforced concrete construction can be used to settle the difficulties. In the respect, structural wire-fabric and loop wire-fabric is utilized. The purpose of this study, on condition of being $210kg/cm^2$ concrete strength, is to analyze the structural and flexural properties of one-way concrete slabs by testing with different reinforcing type, tensile steel ratio based with minimum steel ratio, boundary condition and splice length which affect the maximum width of crack and ductility factor. From the test results, the ductility factor is approved that the slabs using deformed bar were much better than that using wire-fabric, and 30D of splice length was appropriate in the slabs as splice length. In the control of the maximum crack width the slabs using wire-fabric and loop wire-fabric were much better than that using deformed bar.

Interface Shear Strength in Half Precast Concrete Slab (반두께 P.C. 슬래브의 면내전단내력에 관한 연구)

  • 이광수;김대근;최종수;신성우
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.4
    • /
    • pp.161-168
    • /
    • 1994
  • Half-P.C. slab system is the composite structural system which utilizes precast concrete for lower portion and cast in situ concrete for upper portion slab. When the composite slab using Half P.C. slab is deformed by flexural moment, horizontal shear happened at the interface between Half P.C. slab and topping concrete. To resist horizontal shear strength a scratch method has tried. To determine ultimate interface shear strength, shear stress, and shear coefficient, high and normal strength concrete are used for topping concrete. Major variables are compressive strength of topping concrete with or without shear reinforcement, quantitative roughness of the P.C. :surface and tie or untie of the stud with welded deformed wire fabric in the P.C. member. The Icross sectional area on joints is 3,200 $cm^2$ in all specimens. Test results showed that shear stress increased, as the depth of the quantitative roughness increased. The horizontal shear strength could be resisted with safe by the quantitative roughness without shear tie. A shear coefficient determinant equation is proposed such that K = 0.025918 + 0.0068894$\cdot$R – 0.000182354${\cdot}R^2$