• 제목/요약/키워드: weighted least absolute value

검색결과 8건 처리시간 0.028초

Robust Singular Value Decomposition BaLsed on Weighted Least Absolute Deviation Regression

  • Jung, Kang-Mo
    • Communications for Statistical Applications and Methods
    • /
    • 제17권6호
    • /
    • pp.803-810
    • /
    • 2010
  • The singular value decomposition of a rectangular matrix is a basic tool to understand the structure of the data and particularly the relationship between row and column factors. However, conventional singular value decomposition used the least squares method and is not robust to outliers. We propose a simple robust singular value decomposition algorithm based on the weighted least absolute deviation which is not sensitive to leverage points. Its implementation is easy and the computation time is reasonably low. Numerical results give the data structure and the outlying information.

선형계획법을 이용한 견실한 상태추정기의 개발에 관한 연구 (Development of The Robust State Estimator using Linear Programming)

  • 임재섭;권형석;김홍래
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.181-183
    • /
    • 2001
  • This paper presents a robust power system state estimator using linear programming(LP). LP state estimators minimize the weighted sum of the absolute values of the measurement residuals. In this paper, WLS(weighted least square) and WLAV(weighted least absolute value) state estimators are run with same measurement sets including bad data in order to compare the robustness to bad data and convergence characteristics of the two methods. Simulations with three test cases are performed and the results are presented, using IEEE 14 bus system.

  • PDF

가중최소절대값을 이용한 변압기 텝 추정 알고리즘 (An Algorithm for Transformer Tap Estimation by WLAV State Estimator)

  • 김홍래;권형석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.279-281
    • /
    • 1999
  • This paper addresses the issues of the parameter error detection and identification in power system. The parameter error identification is carried out as part of the state estimation procedure. The weighted least absolute value(WLAV) estimation method is used for this procedure. The standard formulation of the state estimation problem is modified to include the effects of the parameter errors as well. A two step procedure for the detection and identification of faulted parameters is proposed. Supporting examples are given using IEEE 14 bus system.

  • PDF

WLAV 상태추정에 의한 전력계통 파라미터 에러 추정에 관한 연구 (Identification of Parameter Errors in Electric Power Systems by WLAV State Estimation)

  • 김홍래;권형석;김동준
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권9호
    • /
    • pp.451-458
    • /
    • 2000
  • This paper addresses the issues of the parameter error detection and identification in electric power systems. In this paper, the parameter error identification and estimation is carried out as part of the state estimation. A two stage estimation procedure is used to detect and identify the parameter errors. The suspected parameters are identified by the WLAV state estimator as the first stage. A new WLAV state estimator adding the suspected system parameters in the state vector is used to estimate the exact value of parameter errors. Supporting examples are given by using IEEE 14 bus system.

  • PDF

Real-Time Identification and Estimation of Transformer Tap Ratios Containing Errors

  • Kim, Hongrae;Kwon, Hyung-Seok
    • KIEE International Transactions on Power Engineering
    • /
    • 제2A권3호
    • /
    • pp.109-113
    • /
    • 2002
  • This paper addresses the issue of parameter error identification and estimation in electric power systems. Parameter error identification and estimation is carried out as a part of the state estimation. A two stage estimation procedure is used to detect and identify parameter errors. Suspected parameters are identified by the WLAV state estimator in the first stage. A new WLAV state estimator adding suspected system parameters in the state vector is used to estimate the exact values of parameters. Supporting examples are given by using the IEEE 14 bus system.

고객만족도 조사도구의 차원별 가중치 부여방법 비교 (A Comparative Study on the Methods for Weighting the Dimensions of Customer Satisfaction with Importance Perceived by Customers)

  • 강명근;조우현;이선희;최귀선;문기태
    • 한국의료질향상학회지
    • /
    • 제7권2호
    • /
    • pp.230-242
    • /
    • 2000
  • Background : The measuring instruments for customer satisfaction in hospitals are often composed of some dimensions reflecting the conceptive complexity of them. Then, overall satisfaction would be expected to be equal the 'weighted' sum of scores by dimensions because the importance rated by customers may be different across the dimensions. But the issue of how to weight the dimensions with importance is not yet solved. We examined 3 sets of weighting methods as to make effect on predictive power against overall satisfaction. Methods : We conducted a survey included 483 subjects who had visited or admitted to a university hospital, using the short form questionnaire being developed by The Korean Society of Quality Assurance in Health Care for out-patient and in-patient. By using a multiple linear regression model, we compared among changes of explanatory powers against overall satisfaction as dependent variable after weighting 4 dimensions of the survey questionnaire as independent variables with importance scores of dimensions perceived by consumers. And we compared the feasibility of each weighting, methods by checking missing cases. Results : There were no weighting methods increasing the explanatory power after applying them. The method of absolute scoring was found higher explanatory-power than others, but this finding had no statistical significance. Regarding the number of missing value, method of absolutely scoring had the least cases. Conclusion : Our findings suggested that weighting the dimensions with importance might have little significance in the cases of scales having items highly correlated, such as consumers' satisfaction. Though asking with items to be answered absolutely, customers might be rating relatively in some degree and this method produced least missing cases. Considering these points, in the cases when weighting the dimensions with importance would be required, we suggest that weighting method by absolute scoring might be better than others.

  • PDF

RSSI의 거리 추정 방식에 바탕을 둔 실내 무선 측위 성능 향상 알고리즘 (Performance Improvement Algorithm for Wireless Localization Based on RSSI at Indoor Environment)

  • 박주현;이정규;김성철
    • 한국통신학회논문지
    • /
    • 제36권4C호
    • /
    • pp.254-264
    • /
    • 2011
  • 본 논문에서는 실내에서 무선으로 위치를 추정하는데 사용되는 삼변측량과 최소제곱법의 정확도 향상을 위한 두 가지 알고리즘을 제안한다. 본 논문에서는 삼변측량을 사용하여 위치를 추정할 때 상대적으로 큰 위치 추정 오차를 발생시킬 수 있는 경우, 즉 3개의 원이 교직선을 형성하지 못하는 경우를 사면체를 위한 헤론의 공식을 적용하여 분류하고, 분류과정에서 얻어진 부피의 절댓값을 이용하여 측정된 추정 거리를 신뢰성 있는 추정 거리로 변환하는 알고리즘을 제안한다. 또한 Anchor node의 개수가 3개 이상인 경우에 사용하는 최소제곱법의 변형된 알고리즘인 RWGH의 연산량을 개선하면서 더 좋은 성능을 낼 수 있는 가중치를 이용한 무게 중심 알고리즘을 제안하고 시뮬레이션을 통해 성능을 검증한다.

최소절대값 상태추정에 의한 전력계통 선로 토폴로지 에러의 추정 (Estimation of Branch Topology Errors in Power Networks by WLAN State Estimation)

  • 김홍래;송경빈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권6호
    • /
    • pp.259-265
    • /
    • 2000
  • The purpose of this paper is to detect and identify topological errors in order to maintain a reliable database for the state estimator. In this paper, a two stage estimation procedure is used to identify the topology errors. At the first stage, the WSAV state estimator which has characteristics to remove bad data during the estimation procedure is run for finding out the suspected branches at which topology errors take place. The resulting residuals are normalized and the measurements with significant normalized residuals are selected. A set of suspected branches is formed based on these selected measurements; if the selected measurement is a line flow, the corresponding branch is suspected; if it is an injection, then all the branches connecting the injection bus to its immediate neighbors are suspected. A new WLAV state estimator adding the branch flow errors in the state vector is developed to identify the branch topology errors. Sample cases of single topology error and topology error with a measurement error are applied to IEEE 14 bus test system.

  • PDF