• 제목/요약/키워드: weight matrix

검색결과 879건 처리시간 0.033초

최적 공분산 가중 벡터를 이용한 상관성 간섭 신호 추정의 빔 지향 오차 (A Study on Beam Error Method of Coherent Interference Signal Estimation using Optimum Covariance Weight Vector)

  • 조성국;이준동;전병국
    • 디지털산업정보학회논문지
    • /
    • 제10권4호
    • /
    • pp.53-61
    • /
    • 2014
  • In this paper, we proposed covariance weight matrix using SPT matrix in order to accurate target estimation. We have estimated a target using modified covariance matrix and beam steering error method. We have minimized beam steering error in order to estimation desired a target. This method obtain optimum covariance weight using modified SPT matrix. This paper of proposal method is showed good performance than general method. We updated a weight of covariance matrix using modified SPT matrix. We obtain optimum covariance matrix weight to application beam steering error method in order to beam steering toward desired target. Through simulation, we showed that compare proposal method with general method. It have improved resolution of estimation target to good performance more proposed method than general method.

통신신호처리를 위한 Jacket 행렬의 특성(特性) (Characteristics of Jacket Matrix for Communication Signal Processing)

  • 이문호;김정수
    • 한국인터넷방송통신학회논문지
    • /
    • 제21권2호
    • /
    • pp.103-109
    • /
    • 2021
  • 1893년 불란서 Hadamard가 발표한 직교 Hadamard 행렬에 대해 이문호교수는 1989년에 Center Weight Hadamard로 새롭게 정의하여 발표했고 1998년에는 Jacket 행렬을 발견했다. Jacket 행렬은 Hadamard 행렬을 일반화한 것이다. 본 논문에서는 Symmetric Jacket 행렬을 구해 중요한 속성과 패턴을 분석하고 Jacket 행렬의 행렬식과 Eigenvalue을 얻는 방법을 제시하며 Eigen decomposition를 사용하여 이를 증명했다. 이러한 계산은 신호 처리 및 직교 코드 설계에 유용하다. 행렬의 체계를 분석하기 위해 DFT, DCT, Hadamard, Jacket 행렬로 비교해 본다. Galois Field의 대칭 행렬에서 Jacket 행렬의 element-wise inverse 관계를 수학적으로 증명하고 직교 성질 AB=I 관계를 유도했다.

A matrix displacement formulation for minimum weight design of frames

  • Orakdogen, Engin
    • Structural Engineering and Mechanics
    • /
    • 제14권4호
    • /
    • pp.473-489
    • /
    • 2002
  • A static linear programming formulation for minimum weight design of frames that is based on a matrix displacement method is presented in this paper. According to elementary theory of plasticity, minimum weight design of frames can be carried out by using only the equilibrium equations, because the system is statically determinate when at an incipient collapse state. In the present formulation, a statically determinate released frame is defined by introducing hinges into the real frame and the bending moments in yield constraints are expressed in terms of unit hinge rotations and the external loads respectively, by utilizing the matrix displacement method. Conventional Simplex algorithm with some modifications is utilized for the solution of linear programming problem. As the formulation is based on matrix displacement method, it may be easily adopted to the weight optimization of frames with displacement and deformation limitations. Four illustrative examples are also given for comparing the results to those obtained in previous studies.

이진 자켓 비트열의 VLSI 구조 (A VLSI Architecture for the Binary Jacket Sequence)

  • 박주용;이문호
    • 한국통신학회논문지
    • /
    • 제27권2A호
    • /
    • pp.116-123
    • /
    • 2002
  • 자켓 행렬(Jacket matrix)은 왈쉬 하다마드(Walsh Hadamard) 행렬 구조를 바탕으로 확장한 행렬이다. 왈쉬 하다마드 행렬이 +1, -1을 기본 원소로 하고 있는 반면 자켓 행렬은 $\pm$1과 $\pm$$\omega$($\pm$j, $\pm$$_2$$^{n}$ )를 각각 원소로 가질 수 있다. 이 행렬은 중앙 부근에 무게(weight)를 갖는데, 하다마드 행렬 크기의 1/4 크기로 부호 부분과 무게 부분으로 구성된다. 본 논문에서는 기존에 행렬 중앙에 강제적으로 무게를 할당하여 자켓 행렬을 구성하였으나, 어떠한 크기의 행렬도 크기와 무게만 정해주면 생성해낼 수 있는 이진 인덱스를 이용한 간단한 비트열 형태의 일반식이 제시된다. 무게는 행과 열의 이진 인덱스의 최상위 두 비트를 Exclusive-OR 연산한 결과가 1인 원소에 부여된다. 또한 분산연산(Distributed Arithmetic:DA) 알고리즘을 이용한 고속자켓변환(Fast Jacket Transform)의 VLSI 구조를 제시한다. 자켓 행렬은 cyclic한 특성을 가지고 있어서 암호화, 정보 이론 및 WCDMA의 복소수 확산 QPSK 변조부에 응용될 수 있다.

특징행렬 데이터베이스를 이용한 NMF 기반 음악전사 (NMF Based Music Transcription Using Feature Vector Database)

  • 신옥근;류다현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권8호
    • /
    • pp.1129-1135
    • /
    • 2012
  • NMF를 이용하여 음악을 전사할 때 표적음악에서 특징행렬과 가중치 행렬을 동시에 추출해 내는 방법을 이용하기 위해서는 특징행렬의 크기(특징벡터의 수)를 미리 알아야 할 뿐 아니라, 추출된 각각의 특징벡터들의 음고를 결정하는 어려운 과정을 거쳐야한다. 또 이 방법은 음악에 포함된 음고의 수가 커질수록 특징행렬을 정확하게 추출해 내기 어려워진다는 단점도 있다. 본 연구에서는 이러한 단점을 피하기 위해 특징행렬 데이터베이스를 미리 준비한 다음 이를 실제 음악에 이용하는 방법을 실험한다. 먼저 특징행렬 데이터베이스를 만든 다음, 특징행렬을 추출한 피아노에서 연주된 음악, 그리고 제 3의 피아노에서 연주된 같은 음악을 각각 전사하여 성능을 비교한다. 또 이들 결과와 비교하기 위하여 특징행렬과 가중치행렬을 동시에 추출하는 방법도 실험하여 결과를 비교하였다. 특징행렬 데이터베이스를 이용하는 방법이 특징행렬과 가중치행렬을 동시에 추출하는 방법보다 좋은 성능을 가짐을 확인하였다.

Recycling of Aluminum Alloy from Al-Cu Metal Matrix Composite Reinforced with SiC Particulates

  • Sharma, Ashutosh;Ahn, Byungmin
    • 한국재료학회지
    • /
    • 제28권12호
    • /
    • pp.691-695
    • /
    • 2018
  • In this study, we investigate the recycling of aluminum-based metal matrix composites(AMCs) embedded with SiC particulates. The microstructure of the AMCs is characterized by X-ray diffraction and scanning electron microscopy. The possibility of recycling the composite scrap is attempted from the melted alloy and SiC particulates by re-melting, holding and solidification in crucibles. The recovery percentage of the matrix alloy is calculated after a number of holding times, 0, 5, 10, 15, 20, 25 and 30 minutes and for different particulate sizes and weight fractions in the Al matrix. The results show that the recovery percentage of the matrix alloy, as well as the time required for maximum recovery of the matrix, is dependent on the size and weight fraction of SiC particulates. In addition, the percentage recovery increases with particulate size but drops with the particulate fraction in the matrix. The time to reach maximum recovery falls rapidly with an increase in particulate size and fraction.

Molecular Weight Determination of Polymers by Matrix Assisted Laser Desorption Ionization in Mass Spectrometry

  • Kim, Jin Sung;Yoo, Jong Shin
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.465-468
    • /
    • 1995
  • Matrix assisted laser desorption ionization in mass spectrometry is a fast and accurate method to determine the molecular weight of natural and synthetic polymers. Unknown peptides such as elastase inhibitor and $\small{D}$-hydantoinase were analyzed using sinapinic acid as matrix and their molecular weights were compared with the results from protein sequencer and gel filtration chomatography, respectively. Synthetic polymers such as polyethyleneglycol, polypropyleneglycol, polydimethylsiloxane, and polystyrene were analyzed using matrices such as 2,5-dihydroxybenzoic acid, 4-hdroxyazobenzenecarboxylic acid, and 2-nitrophenyl octyl ether. Average molecular weights of polystyrene were compared with molecular weights by gel permeation chromatography.

  • PDF

친수성고분자 매트릭스의 Naproxen 제어방출에 관한 연구 (A Study on the Controlled Release of Naproxen from Hydrophilic Polymer Matrix)

  • 김종국;조은실
    • 약학회지
    • /
    • 제31권1호
    • /
    • pp.25-32
    • /
    • 1987
  • The effect of loading dose, plasticiser and PVA molecular weight on naproxen release from hydrophilic polymer matrix was examined. Hydrophilic polymer matrix was prepared with PVA and PVP by adding glycerine as plasticiser. The release of naproxen from polymer matrix was determined in phosphate buffer medium. The release rate of naproxen from the polymer matrix increased as drug loading dose and plasticiser percentage increased. Raproxen released from the polymer matrix showed the time square root kinetics. Without changing the release-pattern, the release rate of naproxen could not be changed by varying molecular weight of PVA. Linearly released time range increased as drug loading dose increased, whereas decreased as plasticiser percentage increased up to 30%.

  • PDF

Signal Estimation Using Covariance Matrix of Mutual Coupling and Mean Square Error

  • Lee, Kwan-Hyeong
    • 한국정보전자통신기술학회논문지
    • /
    • 제11권6호
    • /
    • pp.691-696
    • /
    • 2018
  • We propose an algorithm to update weight to use the mean square error method and mutual coupling matrix in a coherent channel. The algorithm proposed in this paper estimates the desired signal by using the updated weight. The updated weight is obtained by covariance matrix using mean square error and mutual coupling matrix. The MUSIC algorithm, which is direction of arrival estimation method, is mostly used in the desired signal estimation. The MUSIC algorithm has a good resolution because it uses subspace techniques. The proposed method estimates the desired signal by updating the weights using the mutual coupling matrix and mean square error method. Through simulation, we analyze the performance by comparing the classical MUSIC and the proposed algorithm in a coherent channel. In this case of the coherent channel for estimating at the three targets (-10o, 0o, 10o), the proposed algorithm estimates all the three targets (-10o, 0o, 10o). But the classical MUSIC algorithm estimates only one target (x, x, 10o). The simulation results indicate that the proposed method is superior to the classical MUSIC algorithm for desired signal estimation.

Evaluation of Several Parameters of in situ Polymerase Chain Reaction (ISPCR) to Reduce the Leakage of Amplificants from Cells

  • Lee, Jae-Yung;Auh, Chung-Kyoon;George W. Jordan
    • Journal of Microbiology
    • /
    • 제40권1호
    • /
    • pp.70-76
    • /
    • 2002
  • Proviral DNAs from HIV-1-infected CD4+ T cells (Molt/LAV cells) were amplified and detected in infected individual cells using polymerase chain reaction and in rifu hybridization. In this in situ PCR, three parameters were considered to achieve effective amplification and retention of amplificants inside the cells by making high molecular weight PCR products intracellularly, forming agarose matrix against the cells, and maintaining the appropriate PCR temperature profile. Over the cycles of ampliHcationl tailed primers with complementary overhanging sequences at their 5' sides manufactured high molecular weight products by using short primary products as a repeating unit. Agarose matrix could prevent the diffusion of the amplificants from the cells. Use of Thermanox coverslip inside the PCR tube offered target cells a similar temperature profile to that of conventional PCR in solution.