• 제목/요약/키워드: weighing method

검색결과 281건 처리시간 0.028초

식사섭취조사방법의 비교연구 (Comparison of Dietary Methods in Nutritional Studies)

  • 김혜경
    • Journal of Nutrition and Health
    • /
    • 제22권1호
    • /
    • pp.23-31
    • /
    • 1989
  • The purpose of this study was to evaluate the validity of various dietary methods. Dietary intake of 24 patients on regular diet was investigated by three methods. One method was a precise weighing method, the others were 24-hour dietary recall method and convenient dietary questionnaries. The results obtained are summarized as followes ; 1) There were no significant differences in mean nutrient intake of subjects among three dietary survey methods. 2) The validity coefficient between the precise weighing method and 24-hour recall method, ranging from 0.26(fat) to 0.59(carbohydrate) showed significant correlation for carbohydrate, vitamin A, thiamin, riboflavin and ascorbic and intakes. 3) The validity coefficient between precise weighting method and covenient dietary questionnaires, ranging from 0.14(fat) to 0.80(vitamin A), showed a significant correlation for most nutrients. 4) Female showed higher correlation between the precise weighing method and 24-hour recall method than male subjects for most nutrients. However, there was no significant sexual difference of correlation between weighing method and convenient method. 5) The correlation coefficient between the precise weighing method and the other two methods by age group showed younger sujbects have a higher significant correlation than older subjects for most nutrients.

  • PDF

Individual Variation of Na Intake and Urinary Excretion in Korean Women

  • Park, Jung-A;Yoon, Jin-Sook
    • Journal of Community Nutrition
    • /
    • 제1권2호
    • /
    • pp.119-124
    • /
    • 1999
  • The purpose of this study is to investigate the daily variation of Na intake as measured by dietary methods(weighing vs food analysis) and to examine the difference between urniary Na excretion and dietary Na intake in 9 healthy free living women aged 25-64 years living in Taegu, Korea. Information on the dietary Na intake for 5 consecutive days was collected using he weighing method. Twenty four-hour urine samples were collected for the same period to measure the urinary Na excretion. In order to figure out the difference of Na intake with respect to dietary assessment methodology, dietary intake was measured by the weighing method for three of a total 5 days. At the same time, the meals that subjects consumed each day were collected to analyze daily intake of each subject by the food analysis method. The mean Na intake of subjects for 5 consecutive days by the weighing method was 3558. 5mg. The mean of urinary Na excretion for the same period was 2847.5mg/ Na intake and Urinary Na excretion of each subject ranged from 4475.3 to 2838.4, from 4066.4rmg to 1936.1mg respectively. The mean of Na intake for 3 days by the analysis method and the weighing method were 3044.6mg and 3441.6mg, respectively. Each subject showed a great difference among day-to-day variation of Na intake by the weighting method, analysis method and urinary Na excretion method. Therefore, a short term study period may not be valid to estimate the true average Na intake.

  • PDF

10톤 용량의 중량식 교정장치에 대한 불확도 개선 (Improvement of Uncertainty for Gravimetric Flow Calibrator)

  • 이동근;박주영;이행수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1042-1046
    • /
    • 2008
  • Both the weighing bridge and the diverter system is a important component in achieving a high accuracy liquid flow rate standard using a static gravimetric method. The weighing bridge is a tank which weighing collected flow with a load cells. The diverter is a moving device used to direct flow alternately along its normal course(by pass) or towards the weighing tank. The time needed for collection into the weighing tank is measured using a timer. So it is important to the diversion period is sufficiently fast and triggering point of timer which is determined the filling time. On this studies show that the measurement deviation of load cell and uncertainty of diverter system for changing diversion speed and triggering point was estimated in accordance with Guide to The Expression of Uncertainty in Measurement(ISO).

  • PDF

동하중 측정 신호처리의 개발에 관한 연구 (A study on the development of dynamic weighing measurement system)

  • 박찬원;신형재;이영준;신영균;안광희
    • 산업기술연구
    • /
    • 제18권
    • /
    • pp.173-180
    • /
    • 1998
  • A high speed and stable A/D conversion data process is required to weigh a mass on moving conveyer weighing platter. The paper presents a new method to obtain stable and fast automatic weighing A/D conversion data process. Dynamic weighting system which is constructed with dual load cell is realized by the stable A/D conversion data process algorithm using DSP. The proposed method is applied to the real design, and that experimental results showed good performances of the weighing stability.

  • PDF

A-OPTIMAL CHEMICAL BALANCE WEIGHING DESIGN WITH CORRELATED ERRORS

  • Ceranka, Bronislaw;Graczyk, Malgorzata
    • Journal of applied mathematics & informatics
    • /
    • 제16권1_2호
    • /
    • pp.143-150
    • /
    • 2004
  • In this paper we study the estimation problem of individual weights of objects using an A-optimal chemical balance weighing design. We assume that in this model errors are correlated and they have the same variances. The lower bound of tr$(X'G^{-1}X)^{-1}$ is obtained and a necessary and sufficient condition for this lower bound to be attained is given. There is given new construction method of A-optimal chemical balance weighing design.

Partially Balanced Bipartite Weighing Designs from Association Schemes

  • Sinha, Kishore
    • Journal of the Korean Statistical Society
    • /
    • 제6권1호
    • /
    • pp.25-29
    • /
    • 1977
  • A method of constructing partially balanced bipartile weighing designs (PBBWD) from association schemes is given. Some series of three associate PBBWE's from three associate rectangular association schemes are obtained.

  • PDF

z변환을 이용한 시간영역에서의 승차감 평가 (Evaluation of Ride Comfort in Time Domain by Using z-Transform)

  • 김영국;김석원;박찬경;김상수;김기환
    • 한국철도학회논문집
    • /
    • 제14권6호
    • /
    • pp.495-500
    • /
    • 2011
  • 철도차량의 승차감은 승객이 느끼는 감정이므로 물리적인 진동의 크기뿐만 아니라 인간의 감응도(느낌)도 고려하여야 하며, 이러한 진동에 대한 인간의 감응도를 나타낸 것이 주파수 보정곡선이다. 주파수 보정곡선은 라플라스 변환형태의 전달함수이기 때문에 이 전달함수를 직접 사용하여 시간 영역에서의 승차감의 평가가 불가능하다. 이를 해결하기 위해서 본 논문에서는 라플라스 변환형태의 전달함수를 시간 영역에서 사용할 수 있는 전달함수로 변환하는 방법을 제시하고 다양한 예제를 통해 이 방법에 대한 타당성을 입증하였다.

가금류 농장에 적용 가능한 이동식 중량 저울에 관한 연구 (A Study on Portable Weighing Scales Applicable to Poultry Farms)

  • 박성진;박인지;김진영
    • 한국전기전자재료학회논문지
    • /
    • 제35권2호
    • /
    • pp.155-159
    • /
    • 2022
  • Smart livestock, which combines information and communication technology (ICT) with livestock, can be said to be an effective solution to existing livestock problems such as productivity improvement, odors, and diseases. So far, it has hardly been universalized; thus, it is necessary to develop automation devices to reduce labor by localizing automation devices to expand the distribution of ICT technology to farms, and to advance precise specifications and health management technology using biometric information. Weighing scales currently being used in livestock farms are to prevent the spread of diseases by diagnosis and preparation for AI and other diseases in advance, using information on the growing weight of duck breeding. However, accurate values cannot be obtained due to poor breeding conditions. In this paper, we developed a separate data transmission system kit for the weighing scale and placed the sensor on top of the weighing scale so that the sensor wire is not affected by pollutants or ducks on the floor. A display function was provided, and a method of receiving and analyzing the serial port data of the weighing device, and then transmitting them to the data collection server was implemented.

정밀 중량 계측 신호처리를 위한 A/D 변환 시스템 (An A/D Conversion System for Precision Weighing Signal Process)

  • 주용규;전찬민;박찬원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.301-304
    • /
    • 2002
  • This paper has been studied an A/D conversion system for precision weighing signal process In weighing system. A/D conversion has some problem.; offset drift voltage with environment situation and nonzero value of initial output voltage. The Offset voltage in analog circuit produces a drift of an output voltage before A/D conversion stage. This paper suggested the method of reducing the offset voltage by switching analog chopping circuit and making the initial output close to zero to enhance the swing range by D/A converter. Also, we have designed active filter and digital filter with Auto Zero Tracking algorithm for better signal process of the weighing system.

  • PDF

Structural live load surveys by deep learning

  • Li, Yang;Chen, Jun
    • Smart Structures and Systems
    • /
    • 제30권2호
    • /
    • pp.145-157
    • /
    • 2022
  • The design of safe and economical structures depends on the reliable live load from load survey. Live load surveys are traditionally conducted by randomly selecting rooms and weighing each item on-site, a method that has problems of low efficiency, high cost, and long cycle time. This paper proposes a deep learning-based method combined with Internet big data to perform live load surveys. The proposed survey method utilizes multi-source heterogeneous data, such as images, voice, and product identification, to obtain the live load without weighing each item through object detection, web crawler, and speech recognition. The indoor objects and face detection models are first developed based on fine-tuning the YOLOv3 algorithm to detect target objects and obtain the number of people in a room, respectively. Each detection model is evaluated using the independent testing set. Then web crawler frameworks with keyword and image retrieval are established to extract the weight information of detected objects from Internet big data. The live load in a room is derived by combining the weight and number of items and people. To verify the feasibility of the proposed survey method, a live load survey is carried out for a meeting room. The results show that, compared with the traditional method of sampling and weighing, the proposed method could perform efficient and convenient live load surveys and represents a new load research paradigm.