• Title/Summary/Keyword: wedge design

Search Result 185, Processing Time 0.027 seconds

Shape Design of the U-Type Wedge of the Rail Clamp for a Container Crane (컨테이너 크레인용 레일클램프의 U형 쐐기 형상설계)

  • Han, D.S.;Han, G.J.
    • Journal of Power System Engineering
    • /
    • v.13 no.6
    • /
    • pp.117-122
    • /
    • 2009
  • The wedge type rail clamp compresses the rails with small clamping force at first, and with large clamping force when the wind speed increases because of the wedge working. If the supporter is not installed in the rail clamp with V-type wedge when the wind speed increases more and more, the structure will occur overload which leads the structure to fracture. But in the clamp with U-type wedge the supporter is not necessary because the tangential angle of the wedge increases as the sliding distance increases. The proper shape of U-type wedge is determined by the initial clamping force and the tangential angle of the wedge. Accordingly we, first carry out the finite element analysis in order to analyze the relation between the sliding distance and the wedge angle. Next we suggest the proper shape of U-type wedge as analyze the relation between the radius of curvature and the sliding distance.

  • PDF

Study on the Wedge Angle of Wedge Type Rail Clamp for Container Crane (컨테이너 크레인용 쐐기형 레일 클램프의 쐐기각에 대한연구)

  • Han, Geun-Jo;Lee, Ho;Sim, Jae-Jun;Han, Dong-Sub;An, Chan-Woo;Jeon, Young-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.9
    • /
    • pp.119-126
    • /
    • 2004
  • In this paper, we design a wedge type rail clamp which can protect container crane from a sudden strong blast with constant clamping force regardless of the operating period. When we design wedge type rail clamp, it is important to determine the angle of wedge and analyze a contact condition of roller and wedge so that we might develop a wedge type rail clamp for parking devices of port cargo working system with variable capacity. Therefore, this paper suggests a process to decide wedge angles within feasible range which could be obtained using load analysis and FEA of wedge type rail clamp

Load analysis of Wedge type Rail Clamp (쐐기형 Rail Clamp의 하중분석)

  • Han, Geun-Jo;Ahn, Chan-Woo;Kim, Tae-Hyong;Shim, Jae-Joon;Han, Dong-Seop;Lee, Ho
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1-6
    • /
    • 2003
  • In this paper, we design a wedge type rail clamp which can protect container crane from wind with constant clamping force regardless of the operating period. When we design wedge type rail clamp. it is important to determine the angle of wedge and analyze a contact condition of roller and wedge so that we might develop a rail clamp with variable capacity. Therefore, this paper suggest a process to decide wedge angles within feasible range which could be obtained using load analysis and FEA of wedge type rail clamp.

  • PDF

Optical Design for Trepanning Drilling (레이저 트레판닝 드릴링을 위한 광학 설계)

  • Noh, Ji-Whan;Lee, Jae-Hoon;Suh, Jung;Sohn, Hyon-Kee;Shin, Dong-Sig
    • Laser Solutions
    • /
    • v.10 no.3
    • /
    • pp.11-14
    • /
    • 2007
  • A trepanning optics is the optical system which makes focus laser beam rotate and incline to the material processing surface. The trepanning optics is used in order to improve the quality of laser drilling process and control the taper of drilling diameter. In order to make trepanning optics, we can use the eccentricity of lens, scanner using two mirror, dove prism, or wedge. Among these method, in this paper wedge is used for trepanning optics. The wedge trepanning optics has advantage on the high speed of rotation. In this paper, we design the wedge trepanning optics using ray tracing. ements and engine design variables of system to satisfy the customer's requirements.

  • PDF

A Study on the Wedge Angle of the Rail Clamp according to the Design Wind Speed Criteria Change

  • Lee Jung-Myung;Han Dong-Seop;Han Geun-Jo;Jeon Young-Hwan
    • Journal of Navigation and Port Research
    • /
    • v.29 no.7
    • /
    • pp.641-646
    • /
    • 2005
  • In cargo-working, it unavoidably happens that the quay crane slip along the rail and the container move from side to side. Especially, they involve a lot of risk in bad weather. The rail clamp is a mooring device to prevent that the quay crane slips along the rail due to bad weather or the wind blast while the quay crane do the cargo-working And it will play a greater role in port container terminal integration and automation To design the wedge type rail clamp, it is very important to determine the wedge angle. In this study, we expect that the design wind speed of the quay crane will change over 16m/s. Assuming that the design wind speed is 40m/s, we determined the proper wedge angle of the wedge type rail clamp for the 50ton class quay crane.

A Study on the Sliding Distance and the Proper Position of Supporter with respect to the Wedge Angle in the Wedge Type Rail Clamp

  • Han, Dong-Seop;Han, Geun-Jo;Lee, Seong-Wook
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.10a
    • /
    • pp.115-120
    • /
    • 2006
  • The rail clamp is the device to prevent the crane slips along rails from the wind blast as well as to locate a container crane in the set position in operating mode. In this study we conduct the research for the sliding distance of rail clamp and the proper position of supporter with respect to the wedge angle in the wedge type rail clamp. The sliding distance to display the clamping force of the jaw pad corresponding to the design wind speed criteria is determined by the total displacement of the rail clamp at the roller center and the wedge angle. And the supporter is the device to prevent the overload which is applied on each part of the rail clamp by wind speed increment, because a clamping force is generated by the sliding of the wedge due to the wind. Accordingly the position of the supporter to prevent the overload is determined by analyzing the forces applied to the rail clamp. In order to analyze the sliding distance and the proper position of supporter with respect to the wedge angle as the wind speed is 40m/s, 5-kinds of wedge angles, such as 2, 4, 6, 8, $10^{\circ}$, were adopted as the design parameter.

  • PDF

Investigation of Off-Design Performance of Vaned Diffusers in Centrifugal Compressors - Part I : A Channel-Wedge Diffuser - (원심압축기용 베인디퓨져의 탈설계점 성능연구 - 제1부 : 채널디퓨져 -)

  • Oh, JongSik;Hyun, YongIk
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.83-90
    • /
    • 2001
  • Experimental and numerical investigations of the off·design performance of a simple channel-wedge diffuser in a small centrifugal compressor are presented. Surge and choke conditions as well as design point are considered using somewhat limited range of experimental data and also supplementary 3D CFD results. Some critical meanline design parameters' behavior is investigated numerically, to render the basis for improved modelings in the meanline performance prediction.

  • PDF

A study on friction and stress analysis of wedge mount leveler in Semi-Conductor Sub-Fab (반도체 Sub-Fab 용 웨지 마운트 레벨러(Wdge Mount Leveler)의 마찰과 응력에 관한 연구)

  • Min, Kyung-Ho;Song, Ki-Hyeok;Hong, Kwang-Pyo
    • Design & Manufacturing
    • /
    • v.11 no.2
    • /
    • pp.25-28
    • /
    • 2017
  • Semiconductor equipment manufacturers desire to enhance efficiency of Sub Fab to increase semiconductor productivity. For this reason, Sub Fab equipment manufacturers are developing Integrated System that combined modules with multiple facilities. Integrated System is required to apply Mount Leveler of Wedge Type in compliance with weight increase compared with existing single equipment and product shape change. This thesis analyzes main design variables of components of Wedge Mount Leveler and carries out structure analysis using ANSYS, finite element analysis program Analysis shows that main design variables of components of Wedge Mount Leveler has self-locking condition by friction force of Wedge and adjusting bolt. Each friction force hinges upon Wedge angle and Friction Coefficient of contact surface and upon the thread angle and Friction Coefficient of contact surface. Also, as a result of carrying out structure analysis of Wedge Mount Leveler, deflection and stress appears in different depending on the height of the level.

Analytical and computational analysis of pressure at the nose of a 2D wedge in high speed flow

  • Shaikh, Javed S.;Kumar, Krishna;Pathan, Khizar A.;Khan, Sher A.
    • Advances in aircraft and spacecraft science
    • /
    • v.9 no.2
    • /
    • pp.119-130
    • /
    • 2022
  • Supersonic projectiles like rockets, missiles, or aircraft find various applications in the field of defense. The shape of the wings is mainly designed as wedge shape or delta wings for supersonic vehicles. The study of supersonic flows over the wedges and flat plate delta wings around the large scale of incidence angle is considered in the supersonic projectile. In the present paper, the prime attention is to study the pressure at the nose of the plane wedge over the various Mach number and the various angles of incidence. Ghosh piston theory is used to obtain the pressure distribution analytically, and the results are compared with CFD analysis results. The wedge angle and Mach number are the parameters considered for the research work. The range of wedge angle is 50 to 250, and Mach number is 1.5 to 4.0 are considered for the current research work. The analytical results show excellent agreement with the CFD results. The results show that both the parameters wedge angle and Mach number are influential parameters to vary the static pressure. The static pressure increases with an increase in Mach number and wedge angle.

FHD Flexible Endoscopy Design Using Wedge Prism (Wedge Prism을 이용한 FHD급 연성 내시경 광학계 설계)

  • Park, Sung-Woo;Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.6
    • /
    • pp.295-302
    • /
    • 2022
  • In this paper, a wedge prism application method was studied to design a full-high-definition (FHD)-class high-resolution flexible endoscope. In the case of the conventional flexible endoscope optical system, the F number is made large or a liquid lens is applied to obtain the same imaging performance in a wide depth of field. However, there is a problem in that the diameter of the optical system increases because an additional light guide and equipment are required. To solve this problem, two wedge prisms were applied to the flexible endoscope optical system to adjust the image distance for each object distance. First, two wedge prisms were symmetrically placed on the designed endoscopic optical system. An image distance satisfying the target imaging performance according to each objective distance was derived. Next, the wedge prism decenter value for controlling the image distance was derived. By combining these two data, a wedge prism decenter value that satisfied the target imaging performance at each object distance was applied in multi configurations. As a result of the optimal design applied with the wedge prism, a target imaging performance of more than 20% of the modulation transfer function for a resolution of 178 cycles/mm was satisfied in the entire depth of field of 100 mm-7 mm.