Resistivity Protecting analysis due to test survey result (시험탐사 결과에 따른 전기비저항 탐사 분석)

  • Kim, Jae-Hong;Hong, Won-Pho;Park, Chul-Sook;Im, En-Sang
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1285-1289
    • /
    • 2008
  • Increasing the flood control capacity's link that is enforcing to existing dam by unusual change of weather, While build planing construction by exiting spillway of tunnel type to dam, could know that part bed rock is formed as is different with design. Grasped topography of research area and geology state to definite distribution aspect of different bed rock, Place that achieved Surface geological Survey and correct Survey is difficult in some section enforced Electrical resistivity dipole-dipole investigation. Grasped stratigraphy distribution confirmation and fracture or weathering zone making out siding 2D-Resistivity Electrical resistivity diagram and Reverse analysis diagram, examining closely soil weathered rock rock's distribution state, established stability countermeasure plan

  • PDF

Excavation Support Design and Stability Analysis of Shallow Tunnel in Heavily Fractured Rock Mass (연약 파쇄 지반내 터널의 굴착.보강 설계 및 안정성 분석)

  • Shin, Hee-Soon;Synn, Joong-Ho;Park, Chan;Han, Kong-Chang;Choi, Young-Hak;Choi, Yong-Ki
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.87-92
    • /
    • 2000
  • In excavation of tunnels especially located in shallow depth, it is not rare to meet geological change in excavation progress worse than expected in the initial design stage. This paper present a case study on the re-design of excavation and support system of a shallow tunnel under construction where it meets the unexpected bad geological condition during excavation. The detailed geological investigation shows that the rock mass is heavily weathered and fractured with RMR value less than 20. Considering this geological condition, the design concept is focused on the reinforcement of the ground preceding the excavation of tunnel. Two design patterns, LW-grouting & forepoling with pilot tunnelling method and the steel pipe reinforced grouting method, are suggested. Numerical analysis by FLAC shows that these two patterns give the tunnel and roof ground stable in excavation process while the original design causes severe failure zone around the tunnel and floor heaving. In point of the mechanical stability and the degree of construction, the steel pipe reinforced grouting technique proved to be good for the reinforcement of heavily fractured rock mass in tunnelling. This assessment and design process would be a guide in the construction of tunnels in heavily weathered and fractured rock mass situation.

  • PDF

Numerical Investigation of Freezing and Thawing Process in Buried Chilled Gas Pipeline (매설 냉각가스관의 동결-융해에 대한 수치해석 연구)

  • Shin, Hosung;Park, Heungrock
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.6
    • /
    • pp.17-26
    • /
    • 2016
  • Characteristic behaviors of geo-structure during freezing and thawing process have to be understood based on fundamental knowledge on phase change in porous soil and interaction between soil and structure. Inversion analysis using published one-dimensional soil freezing tests was conducted to suggest a mechanical model to consider an effect of the ice saturation on Young's modulus. Silty soil was more sensitive to temperature than weathered granite soil and sand, and weathered granite soil was more affected by initial water saturation in stiffness decrease than silty soil. Numerical simulations on chilled gas pipeline showed that shielding effect from surrounding frozen zone around the pipe decreases impact from external load onto the pipe. And a pipe installed in sand backfill showed more heaving due to relatively low stiffness of sand during freezing than that of surrounding in-situ weather granite soil. However, it had more stable stress condition due to effective stress redistribution from external load.

Relationship between Hydrogeological Characteristics and Subsurface Geology in Central Busan Megacity (부산광역시 도심부 수리지질 특성과 지하지질 발달상태의 관련성)

  • Ryu, Sang-Hun;Hamm, Se-Yeong;Cha, Yong-Hoon;Jang, Seong;Jeong, Jae-Hyeong;Son, Moon;Kim, Ki-Seok
    • The Journal of Engineering Geology
    • /
    • v.17 no.3
    • /
    • pp.367-379
    • /
    • 2007
  • This study intended to evaluate hydrogeological characteristics in relation to subsurface geology data obtained from borehole, groundwater level, borehole flowmeter test, and field hydraulic tests. The regression equation of groundwater level (Y) versus ground elevation (X) is expressed by Y=0.75X-7.00 with quite high correlation coefficient of 0.78. Relationship between groundwater level and thickness of landfill, alluvium, and weathered zone results in higher correlation of groundwater level (Y) versus natural log value of weathered tone (A) than other correlations, with the regression equation Y= exp(9.974A)-14.155. The result of groundwater flow measurement in the boreholes indicates that groundwater flows towards between south and southwest, and this approximately agree with regional distribution of groundwater levels.

An Analysis on Co-relationships Between In-situ Investigation Methods and End Bearing Capacity of A Drilled Shaft Socketed into the Weathered Zone (풍화대소켓 현장타설말뚝의 극한단위선단지지력과 원위치 지반조사방법들과의 상관관계 분석)

  • Choi, Yongkyu;Kwon, Oh Sung;Lee, Jong Seong;Choi, Sung Soon;Jung, Sung Min
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.2C
    • /
    • pp.95-107
    • /
    • 2010
  • To calculate the end bearing capacity of a drilled Shaft socketed into the rockmass, the unconfined compression strength could be used. But it is difficult to find the unconfined compression strength because it is impossible to get undisturbed samples in weathered soils and rocks. So, to calculate the end bearing capacity, the existing bearing formula could not be used. In this study, for five zones (near pile tip, tip~lower 1D, tip~lower 2D, upper 1D~lower 1D, upper 1D~lower 2D), the relationships between the characteristic values of in-situ tests(SPT, DCPT PMT, BST) and the end bearing capacity of drilled shafts were analysed. As a result, DCPT results were represented the best credibility. Also, a design chart of end bearing capacity using DCPT was suggested.

Distribution of Resistivity Zones Near Nari Caldera, Ulleung-do, Korea, Inferred from Modified Dipole Arrays (변형 쌍극자배열법을 적용한 울릉도 나리 칼데라 주변 조면안산암 지역의 비저항분포 특성 분석)

  • Kim, Ki-Beom;Kim, Man-Il
    • The Journal of Engineering Geology
    • /
    • v.29 no.3
    • /
    • pp.223-236
    • /
    • 2019
  • Resistivity surveys can identify the distribution of geological units and structures (including fragmented fault zones), the extent of weathered and modified geological strata, and the characteristics of groundwater. This study aims to analyze the underground sedimentary layers and geological structures near the Nari and Albong Basins of Ulleung-do, Korea, focusing on six survey lines to identify the spatial trends in subsurface resistivity. A modified dipole array method (D method) was employed, combining resistivity results obtained by existing dipole array methods (A and C methods). The modified method provides optimal analysis of the cross-section of underground resistivity, and shows a clear boundary between a low-resistivity zone (${\leq}500{\Omega}{\cdot}m$) of sedimentary layers and weak zones, and a high-resistivity zone (${\geq}5,000{\Omega}{\cdot}m$) of volcanic rock (trachyandesite). The estimated average thickness of the sedimentary layers is 50~100 m for the Albong Basin and 100~200 m for the Nari Basin. An anomaly zone, different from the weak zone in the bedrock, is identified as a caldera fault, and the low-resistivity zone extends from the surface down to the lowest survey depths.

An Analysis of Seawater Effect on Groundwater Quality, in the Region of Sinan-gun area, Jeonam, Korea (전남 신안군 지역의 지하수 수질에 대한 해수의 영향 분석)

  • Shin, Kyungsun;Koh, Dong-Chan;Lee, Jeonghoon
    • Journal of the Korean earth science society
    • /
    • v.38 no.7
    • /
    • pp.570-580
    • /
    • 2017
  • The purpose of the study was to evaluate the groundwater quality of Sinan-gun, Jeollanam-do, an island located in the southern part of the Korean peninsula where the effect of seawater on the groundwater quality had not been investigated in the past. In order to evaluate its effect, the hydrogeological parameters including groundwater quality and major dissolved components were investigated. The water quality was measured four times in the field, and 74 of 163 samples that showed the high conductivity value of more than $500{\mu}S/cm$ and the influence of seawater on the groundwater were analyzed by $Cl^-/HCO_3{^-}$ molar ratio. The results showed that, 40 samples out of 74 were found to have a value of 2.8 or more, indicating severe and very severe effects. According to the type of groundwater quality, the ratio of samples belonging to Na-Cl type, which is considered to be influenced by the direct seawater, is 35.3% for bedrock groundwater and 52.5% for weathered zone and alluvial groundwater. In the evolution stage of groundwater due to seawater infiltration, the type of Ca-Cl prior to the Na-Cl type is 44.1% in bedrock groundwater and 45% in weathered zone and alluvial groundwater. The effect of sea water on the aquifer is likely to be influenced by distance from the shore, pumped water, and tide.

Analysis on Surface Collapse of the Road NATM Tunnel through the Weathered Rock (풍화대를 통과하는 도로 NATM 터널의 천단부 함몰에 대한 연구)

  • Shin, Eun-Chul;Yoo, Jai-Sung
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.2
    • /
    • pp.55-64
    • /
    • 2016
  • The construction of the road NATM tunnel, which undergoes the weathered zone of the mountain, was in process with the reinforcement methods such as the rock bolt, shotcrete depositing, and the multi step grout with large diameter steel pipe. The collapse from the ceiling, and on the ground surface area(sink hole), of which were measured to be 25m from the ground surface($V=12m(W){\times}14m(L){\times}5m(H)=840m^3$), as well as excessive displacements in the tunnel, had occurred. In order to execute the necessary reconstruction work, the causes of the surface collapses were inspected through the field investigation, in-situ tests, and numerical analysis. As a result, several proper solutions were suggested for both internal and external reinforcements for the tunnel. As a result of numerical analysis, the collapsed zone of the tunnel was reinforced up to 0.5D~1.0D laterally by the cement grouting on the ground surface, 0.5D longitudinally by the multi step grout with large diameter steel pipe in tunnel. With further reinforcement implemented by rebars in lining, the forward horizontal boring was executed to the rest of the tunnel to evaluate the overall status of the tunnel face. Appropriate reinforcement methods were provided if needed.

Hydrogeochemical Characteristics and Occurrences of High-Saline Ground Water at Seocheon Area, Korea (서천 길산천 소유역의 고염분 지하수 수질과 산출 특성)

  • Moon, Sang-Ho;Lee, Bong-Joo;Park, Kwon-Gyu;Ko, Kyung-Seok
    • Economic and Environmental Geology
    • /
    • v.42 no.3
    • /
    • pp.235-246
    • /
    • 2009
  • High-saline ground water, whose eclectrical conductivity value ranges from 12,000 to 21,000 $\mu$S/cm, occurs at the small catchment of Gilsan stream near Geum-river estuary dike. These high-saline ground water comes form three different aquifers consisting of two horizons of sand sediments and one weathered zone with top part of unconformity. For these three aquifers showing mutual independence in terms of hydrogeological and hydrogeochemical connection, we examined characteristics of aqifer occurrences and their water chemistry, and observed and analyzed the fluctuations of the ground water level and electrical conductivity. Our study results indicate that the high-saline characteristics of ground water in this study area should not come from dynamic recent seawater intrusion, but might be due to the fossil saline water included and isolated within the paleo-sediments or weathered zone and their upper unconformity part. This high-saline water seems to be now partially mixed and affected by freshwater in the higher inland reach of Gilsan stream.

Image Enhancement of the Weathered Zone and Bedrock Surface with a Radial Transform in Engineering Seismic Data (엔지니어링 탄성파자료에서 방사변환을 통한 풍화대 및 기반암 표면의 영상강화)

  • Kim, Ji-Soo;Jeon, Su-In;Lee, Sun-Joong
    • The Journal of Engineering Geology
    • /
    • v.22 no.4
    • /
    • pp.459-466
    • /
    • 2012
  • A difficulty encountered in engineering seismic mapping is that reflection events from shallow discontinuities are commonly overlapped with coherent noise such as air wave, direct waves, head waves, and high-amplitude surface waves. Here, the radial trace transform, a simple geometric re-mapping of a trace gather (x-t domain) to another trace gather (v-t domain), is applied to investigate the rejection effect of coherent linear noises. Two different types of data sets were selected as a representative database: good-quality data for intermediate sounding (hundreds of meters) in a sedimentary basin and very noisy data for shallow (${\leq}50m$) mapping of the weathered zone and bedrock surface. Results obtained with cascaded application of the radial transform and low-cut filtering proved to be as good as, or better than, those produced using f-k filtering, and were especially effective for air wave and direct wave. This simple transform enables better understanding of the characteristics of various types of noise in the RT domain, and can be generally applied to overcoming diffractions and back-scatterings caused by joints, fractures, and faults commonly that are encountered in geotechnical problems.