• Title/Summary/Keyword: wearing experiment

Search Result 224, Processing Time 0.028 seconds

Thermal Comfort and Tactile Wearing Performance of Wool/nylon Fabrics for Tra-biz Garment (울/나일론 tra-biz 의류용 직물 소재의 열적 쾌적성과 착용특성)

  • Kim, Hyun Ah
    • Fashion & Textile Research Journal
    • /
    • v.18 no.6
    • /
    • pp.878-888
    • /
    • 2016
  • In this study, wool/nylon(50/50%) blend yarn and its fabrics for tra-biz(complex word of travel+business) garment were prepared, and its wear comfort characteristics were investigated through thermal manikin and human-body wearing experiment. In addition, tactile wearing performance from fabric mechanical properties and the dimensional stability and the pilling of the fabric specimen during wearing and dry-cleaning were measured and compared with those of wool 100% fabric specimen. Heat keepability of the wool/nylon(50/50%) blend fabric by thermal manikin experiment was superior than that of wool 100% fabric, this result was verified with human-body wearing experiment and its result coincided well with this experimental result. Tactile wearing performance of the wool/nylon(50/50%) fabric from fabric mechanical properties measured by FAST system was better than that of the wool 100% fabric. The dimensional stability of the wool/nylon(50/50%) fabric was more stable than that of the wool 100% fabric. Because relaxation shrinkage was lower and hygral expansion of wool 100% fabric was more high. However, the breathability and pilling property of the wool/nylon(50/50%) fabric were inferior than those of the wool 100% fabric. The possibility of application for tra-biz garment of wool/nylon(50/50%) blend fabric was observed because of good heat keepability, tactile wearing performance and washing fastness.

The Relationship between Shoe Wearing Trait and Foot Shape of Women in Their Twenties (20대 여성의 구두 착용 특성과 발 유형의 관계)

  • Choi, Sun-Hui;Chun, Jong-Suk
    • The Research Journal of the Costume Culture
    • /
    • v.17 no.1
    • /
    • pp.68-75
    • /
    • 2009
  • The purpose of this study is to find the relationship between women's shoes wearing trait and their foot shape. 203 women in their twenties were participated in the experiment. The subjects' feet were measured with a 3D foot scanner and their foot shapes were classified into five types by factor analysis and cluster analysis in the previous study. In addition to the five foot types, three foot types classified by foot index were also utilized for this study. This study analyzed the trait of their shoe wearing and the areas of discomfort on the foot when they wore shoes. The results of the experiment show that the size of shoe size-foot size mismatching and the foot areas of discomfort wearing shoes were differentiate by foot types. It shows that the subjects with long foot, wide fore foot shape, or fore foot angle deformity wore larger size shoes than their foot size. The foot areas of discomfort with wearing shoes were different according to the foot types. Subjects with wide fore foot shape or fore foot angle deformity had discomfort at the front shoe area. The subjects with straight toes had the least discomfort. The foot discomfort areas differentiated according to foot index type. The foot types with wide ball width experienced discomfort at the front of the ball and the top of the foot.

  • PDF

Physiological Responses of Cold Protective Clothing with Different clo Value (보온력 차이에 따른 방한복 상의의 인체착의 생리반응)

  • Lee, Jung-Sug;Kim, Hee-Eun;Song, Min-Kyu
    • Fashion & Textile Research Journal
    • /
    • v.10 no.5
    • /
    • pp.683-689
    • /
    • 2008
  • The purpose of this study was to investigate physiological responses such as rectal temperature, skin temperature, micro climate, sweat rate and subjective sensations using cold protective clothing with five different clo value. The clo value was measured by thermal manikin in windless condition. Healthy five 20's males volunteered as subjects for wearing trial experiment. The climate chamber was controlled at $50^{\circ}C$, 65% RH. The experiment consisted of repeated exercise and recovery periods. We found that the higher clo value has, the higher mean skin temperature, micro climate and sweat rate show. They felt warm and wet with higher insulation clothing. Thermal comfort increased in the last recovery period after exercise. There was significant difference between five cold protective clothing. In correlation analysis of clo value, it showed that correlation coefficient(r) values were more than 0.8. Therefore, in terms of clothing insulation, we found that correlation between thermal manikin experiment and wearing trial experiment was high. Clothing insulation could be variable according to many factors such as body movement, covering area, clothing gap, layering and design. Considering the body movement, we thought that insulation measurement need to carry out both thermal manikin experiment and wearing trial experiment.

A Experimental Study on Wearing Phenomenon of Cu-type Wearing Slider for the Rail Motor Car's Pantograph (집전장치용 동계 주습판의 마모현상에 관한 실험적 연구)

  • Kim, Kyung-Seob
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.3
    • /
    • pp.224-230
    • /
    • 2012
  • The wearing slider of the rail motor car's pantograph is considerable changed by the type and the material properties. Especially, precipitation and arc influences are main factors decided to life time of wearing slider and contact wire. This study is wearing phenomenon analysis of Cu-type wearing slider with high electric conductivity and resistance arc through experiment by running train. Author observed that wearing phenomenon of Cu-type wearing slider with normal and abnormal wearing characteristics and comparatively analysis precipitation, mileage and weight influences of exchanged Cutype and Fe-type wearing sliders. In this paper result showed that necessity for the application which is the Fe-type of wearing slider had superior wear resisting capacity etc., through tribology approach.

Wearing of a Whole-Body Compression Garment Can Enhance Exercise Efficiency

  • Jeon, Su-Jeong;Jung, Yu-Jin;Lee, Eun-Jae;Choi, Ji-Hye;Jung, Dongju
    • Biomedical Science Letters
    • /
    • v.27 no.2
    • /
    • pp.88-94
    • /
    • 2021
  • A whole-body compression garment (WBCG) is mainly used for cosmetic purpose in Korea. Another case for wearing the WBCG would be while exercising because it allows the body to move easily. But physiological effects of wearing WBCG to the body have not been known much. To investigate whether wearing WBCG would be helpful for conducting exercises, we measured physiological criteria, which could be influenced by the compression, such as cardiovascular and pulmonary function. Twelve female college students participated in this experiment. Increase of blood pressure was monitored in all of the participants when they wore a WBCG just for 10 minutes. Pulmonary function that requires skeletal muscle contraction was decreased by wearing a WBCG. Blood pressure measured after conducting exercise became even lower when wearing a WBCG than non-wearing. Interestingly, heart pulse remained lower when wearing a WBCG than non-wearing during the whole relaxing period after the exercise. Electrocardiogram (ECG) analyses showed that such lower heart rate largely depended on extension of QT time. For that reason, physiological efficiency index (PEI) was higher for wearing WBCG. These results indicate wearing WBCG could enhance exercise efficiency by lowering heart pulse.

Characteristics of the Muscular Activities on the Feedback Control of Elbow Orthosis Using Pneumatic Rubber Artificial Muscle (공압 고무 인공근육을 장착한 주관절 보조기 피드백 제어 시 근력 특성)

  • Hong, Kyung-Ju;Kim, Kyung;Kwon, Tae-Kyu;Kim, Dong-Wook;Kim, Nam-Gyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.4
    • /
    • pp.725-728
    • /
    • 2008
  • An elbow orthosis with a pneumatic rubber actuator has been developed to assist and enhance upper limbs movements and has been examined for the effectiveness. The effectiveness of the elbow orthosis was examined by comparing muscular activities during alternate dumbbell curl motion wearing and not wearing the orthosis. The subjects participated in the experiment were younger adults in their twenties. The subjects were instructed to perform dumbbell curl motion in a sitting position wearing and not wearing orthosis in turn and a dynamometer was used to measure elbow joint torque outputs in an isokinetic mode. Orthosis was controlled using contractile muscle force that is measured from force sensor through cDAQ-9172 board. The air pressure of the pneumatic actuator was 0.3MPa the most suitable air pressure. For the analysis of muscular activities, Electromyography of the subjects was measured during alternate dumbbell curl motion. The experiment results showed that the muscular activities wearing the elbow orthosis were reduced. With this, we confirmed the effectiveness of the developed elbow orthosis.

Thermophysiological Response of Human Body in Wearing Codling Vest (냉각조끼착용에 따른 인체의 온열생리학적 특성)

  • 권오경;김태규
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.11a
    • /
    • pp.148-154
    • /
    • 2000
  • To do this study, we produced cooling vest newly. Rectal temperature was ascended approximately from 37.2$^{\circ}C$ to 38.05$^{\circ}C$ in lab, but wearing cooling vest, the temperature was descended 0.2 while wearing developed product compare with existing product. Mean skin temperature which was showed distribution from 32.8∼36.5$^{\circ}C$, it was descended 1.0∼1.1$^{\circ}C$, while wearing cooling vest and comparing with existing product, wearing developed product was lower 0.5$^{\circ}C$, While wearing developed product, it was found that they had lower tendency than exiting product. Specifically in case of temperature within clothing(chest) 0.2∼2.0$^{\circ}C$ in case of humidity within clothing 2∼8% RH. Facts from above we confirmed that clothing microclimate had been improved and space was happened between body and garment in order to control. In subjective sensation, existing product made negative response during experiment period from participants, but developed product was nearing to comfortable area.

  • PDF

Influence on the Difference in Proportion of Leg Joint Angle during Walking, Cobb's Angle, Foot Pressure (가방 착용 방법에 따른 보행 시 다리관절 각도, 콥스 각, 족압 비율의 변화)

  • Lee, Jonathan;Lee, Su-Hyun;Jang, Sang-Hun
    • Journal of Korean Physical Therapy Science
    • /
    • v.25 no.2
    • /
    • pp.7-14
    • /
    • 2018
  • Purpose: This study was conducted to analyze the effect of bag type on gait kinematic factors. The purpose of this study was to compare the Cobb's angle, leg angle and foot pressure difference according to bag type among 20 university students. Methods: The bag type was applied with two kinds of bags: not wearing a bag, backpack, and an eco bag. The bag weight was 10% of subjects weight in during experiment and only bag weight was 0.5kg. Results: Knee joint angle is increased when wearing backpack or an eco bag than not wearing bag. Cobb's angle increased when wearing backpack and wearing eco back. The difference in right and left foot pressure increased when wearing eco bag than not wearing bag and wearing backpack. Conclusion: Therefore, wearing a heavy backpack or an eco bag when walking for a long time may cause scoliosis and change the walking form.

Efficacy of Cooling Vest for Auxiliary Body Cooling in Hot Environments(2) - Comparison in Terms of Thermophysiological Properties Between New Cooling Vest and Standard Cooling Vest - (고온환경 하에서 착용하는 인체냉각 보조도구로서의 Cooling Vest연구(2) - 개발제품의 온열생리학적특성 -)

  • Kwon, Oh-Kyung;Kim, Tae-Kyo;Kim, Jin-A
    • Fashion & Textile Research Journal
    • /
    • v.2 no.4
    • /
    • pp.346-352
    • /
    • 2000
  • The purposes of this study are finding out thermophysiological properties throughout wearing experiment with standard cooling vest as well as providing data in order to design and apply more comfortable cooling vest. To do this study, we produced cooling vest newly. 1. Rectal temperature was ascended approximately from $37.2^{\circ}C$ to $38.05^{\circ}C$ in lab, but wearing cooling vest, the temperature was descended 0.2 while wearing developed product compare with existing product. Mean skin temperature which was showed distribution from $32.8{\sim}36.5^{\circ}C$, it was descended $1.0{\sim}1.1^{\circ}C$, while wearing cooling vest and comparing with existing product, wearing developed product was lower $0.5^{\circ}C$. 2. While wearing developed cooling vest, it was found that they had lower tendency than standard cooling vest. Specifically in case of temperature within clothing (chest) $0.2{\sim}2.0^{\circ}C$ in case of humidity within clothing 2~8%RH. Facts from above we confirmed that clothing microclimate had been improved and space was happened between body and garment in order to control. 3. In subjective sensation, standard cooling vest made negative response during experiment period from participants, but new cooling vest was nearing to comfortable area. It was con finned from above conclusions that wearing developed product is more effective in terms of comfort and reduction of heat stress in situation of working in hot environment.

  • PDF

Development and Wearing Comfort Analysis of Motorcycle Wear with Built-in Airbag (에어백 장착 모터사이클복의 제품개발 및 착용감 분석)

  • Choi Hei-Sun;Do Wol-Hee
    • Journal of the Korean Home Economics Association
    • /
    • v.43 no.6 s.208
    • /
    • pp.27-35
    • /
    • 2005
  • The purpose of this study was to develop motorcycle wear with built-in airbag protection for enhanced comfort and fit. Based on the survey results, a motorcycle jacket was designed using. Aauto CAD. This study concentrated on the wearing comfort comparison of the motorcycle jacket developed from this research with that of and foreign goods. To evaluate the wearing comfort, 3 types of motorcycle jackets were used. The results of this study were as follows. : From an Analysis of the differences in wearing comfort, the motorcycle jacket developed proved to be more convenient than the 2 types of foreign motorcycle jackets in terms of the standing and handle grip posture. This effect was due to the curved pattern of the neckline part of the airbag. The air pressure of the airbag must be improved.