• Title/Summary/Keyword: wearable smart device

Search Result 170, Processing Time 0.026 seconds

Design and Implementation of Gamified Tourtainment Service Platform (게임화 투어테인먼트 서비스 플랫폼 설계 및 구현)

  • Lee, Deuk-Woo;Cho, Byung-Sang;Hwang, Ho-Sung;Kim, Se-Hyeon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.3
    • /
    • pp.153-158
    • /
    • 2017
  • With the fast increment of fusion ICT(Information and Communication Technology), new creative tourism model is required for the revival of local economy. We come up with new frame that is able to increase tourists and revive local economy through ICT fusion such as spatial informaion, contents, game, smart phone, wearable device and wireless internet. In this paper, we propose 'Gamified Tourtainment Service Platform' that can be provided tourists with user custom tour guidance and gamified tour services for motivation, fun, contest, reward in the environment of outdoor. This platform is a kind of framework for creating and providing gamified creative tour services and a gateway for increasing tourist and reviving commercial local economy. We also propose the real tourtainment service application that is implemented with this platform and smart phone.

Implementation of Real-time Heart Activity Monitoring System Using Heart Sound (심음을 이용한 실시간 심장 활동 상태 모니터링 시스템 구현)

  • Kim, Jin-Hwan;Noh, Yun-Hong;Jeong, Do-Un
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.1
    • /
    • pp.14-19
    • /
    • 2018
  • Recently, the smart health care industry has been rising rapidly and interest and efforts for public health have been greatly increased. As a result, the public does not visit medical specialists and medical facilities, but the desire to check their health condition in everyday life is increased. Therefore, many domestic and foreign companies continuously research and develop wearable devices that can measure body activity information anytime and anywhere And the market. Especially, it is used for heart activity measurement device using pulse wave sensor and electrocardiogram sensor. However, in this study, a monitoring system that can detect cardiac activity using cardiac sounds, heart sound measurement rather than pulse wave measurement and electrocardiogram measurement, was performed and its performance was evaluated. Experimental results confirmed the predictability of cardiac heart rate and heart valve disease during daily living.

Effect of Progressive Squat Exercise on Lower Body Muscles Activity and Foot Pressure in Male College Students

  • Jin-Wook, Lee;Jin-Young, Jung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.2
    • /
    • pp.143-151
    • /
    • 2023
  • This study examined the changes in lower body muscle activity and foot pressure during progressive squat exercise in male college students. It was conducted to help efficient exercise guidance by identifying and recognizing muscle imbalance using EMG and smart shoes and providing immediate feedback. The subjects of the study were 20 students from D University. As a result of this study, as the squat load increased, the activity of all muscles except for the left semitendinosus muscle and the anterior tibialis muscle significantly increased among. Foot pressure, when the squat load was increased, the pressure of the forefoot(FF) increased significantly and the pressure of the rear foot(RF) decreased significantly. Therefore, providing immediate feedback using a wearable device will prevent muscle imbalance and provide effective exercise guidance.

Development of u-Health Care System for Dementia Patients (치매환자를 위한 u-Health Care 시스템 개발)

  • Shin, Dong-Min;Shin, Dong-Il;Shin, Dong-Kyoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.12
    • /
    • pp.1106-1113
    • /
    • 2013
  • For patients who have senile mental disorder such as dementia, quantity of excercise and amount of sunlight are important clue for dose and the treatment. Therefore, monitoring health information of daily life is necessary for patients' safety and healthy life. Portable & wearable sensor device and server configuration monitoring data are needed to provide these services for patients. Watch-type device(smart watch) which patients wear and server system are developed in this paper. Smart watch developed includes GPS, accelerometer and illumination sensor, and can obtain real time health information by measuring the position of patients, quantity of exercise and amount of sunlight. Server system includes the sensor data analysis algorithm and web server that doctor and protector can monitor through sensor data acquired from smart watch. The proposed data analysis algorithm acquires quantity of exercise information and detects step count in patients' motion acquired from acceleration sensor and to verify this, the three cases with fast pace, slow pace, and walking pace show 96% of the experimental result. If developed u-Healthcare System for dementia patients is applied, more high-quality medical service can be provided to patients.

BIOFIT - Smart, Portable, Wearable and Wireless Digital Exercise Trainer Device with Biofeedback Capability

  • Diwakar Praveen Kumar;Oh Young-Keun;Chung Gyo-Bum;Park Seung-Hun
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.36-45
    • /
    • 2007
  • Today Human Personal Trainers are becoming very famous in this health conscious world. They teach user to achieve fitness goals in managed way. Due to their high fee and tight schedule they are unavailable to mass number of people. Another solution to this problem is to develop digital personal trainer portable instrument that may replace human personal trainers. We developed a portable digital exercise trainer device - BIOFIT that manages, monitors and records the user's physical status and workout during exercise session. It guides the user to exercise efficiently for specific fitness goal. It keeps the full exercise program i.e. exercises start date and time, duration, mode, control parameter, intensity in its memory which helps the user in managing his exercise. Exercise program can be downloaded from the internet. During exercise it continuously monitors the user's physiological parameters: heart rate, number of steps walked, and energy consumed. If these parameters do not range within prescribed target zone, the BIOFIT will alarm the user as a feedback to control exercise. The BIOFIT displays these parameters on graphic LCD. During exercise it continuously records the heart rate and number of steps walked every 10 seconds along with exercise date and time. This stored information can be used as treatment for the user by an exercise expert. Real-time ECG monitoring can be viewed wirelessly (RF Communication) on a remote PC.

Private Blockchain and Biometric Authentication-based Chronic Disease Management Telemedicine System for Smart Healthcare (스마트 헬스케어를 위한 프라이빗 블록체인과 생체인증기반의 만성질환관리 원격의료시스템)

  • Young-Ae Han;Hyeok Kang;Keun-Ho Lee
    • Journal of Internet of Things and Convergence
    • /
    • v.9 no.1
    • /
    • pp.33-39
    • /
    • 2023
  • As the number of people with chronic diseases increases due to an aging society, it is urgent to prevent and manage their diseases. Although biometric authentication methods and Telemedicine Systems have been introduced to solve these problems, it is difficult to solve the security problem of medical information and personal authentication. Since smart healthcare includes personal medical information of subjects, the security of personal information is the most important field. Therefore, in this paper, we tried to propose a Telemedicine System using a smart wearable device ECG in the form of a wristband and face personal authentication in a private blockchain environment. This system targets various medical personnel and patients with chronic diseases in all regions, and uses a private blockchain that can increase data integrity and transparency, ECG and face authentication that are difficult to forge and alter and have high personal identification to provide a system with high security and reliability. composed. Through this, it is intended to contribute to increasing the efficiency of chronic disease management by focusing on disease prevention and health management for patients with chronic diseases at home.

Performance analysis of SNR and BER for radiation pattern reconfigurable antenna (인체 부착용 방사패턴 재구성 안테나의 SNR 및 BER 성능 분석)

  • Lee, Chang Min;Jung, Chang Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4125-4130
    • /
    • 2015
  • This paper presents the communication performance for the radiation pattern reconfigurable antenna in the wearable device measuring bio signal (temperature, blood pressure, pulse etc.) of human body. The operational frequency is 2.4 - 2.5 GHz, which covers Bluetooth communication bandwidth. The maximum gain of the antennas is 1.96 dBi. The proposed antenna is efficiently transmitting and receiving signal by generating two opposite beam directions using two RF switches (PIN diode). Also, we investigated how radiation pattern changes according to three angles ($30^{\circ}$, $90^{\circ}$, $150^{\circ}$) of Top Loading. In this paper, we measured and compared the SNR (Signal-to-Noise Ratio) and BER (Bit Error Rate) performances of the proposed antennas in the condition between an ideal environment of anechoic chamber and smart house existing practical electromagnetic interferences (Universal Software Radio Peripheral, USRP). Throughout the comparing the results of the measurement of two cases, we found that the SNR is degraded over 5dB in average and BER is increased over ten times in maximum, therefore, it is confirmed that the error rate of receiving signal is increased. The measured results of SNR and BER value in this paper able to expect the performance degrading by the interference from the electromagnetic devices.

Activity and Safety Recognition using Smart Work Shoes for Construction Worksite

  • Wang, Changwon;Kim, Young;Lee, Seung Hyun;Sung, Nak-Jun;Min, Se Dong;Choi, Min-Hyung
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.2
    • /
    • pp.654-670
    • /
    • 2020
  • Workers at construction sites are easily exposed to many dangers and accidents involving falls, tripping, and missteps on stairs. However, researches on construction site monitoring system to prevent work-related injuries are still insufficient. The purpose of this study was to develop a wearable textile pressure insole sensor and examine its effectiveness in managing the real-time safety of construction workers. The sensor was designed based on the principles of parallel capacitance measurement using conductive textile and the monitoring system was developed by C# language. Three separate experiments were carried out for performance evaluation of the proposed sensor: (1) varying the distance between two capacitance plates to examine changes in capacitance charges, (2) repeatedly applying 1 N of pressure for 5,000 times to evaluate consistency, and (3) gradually increasing force by 1 N (from 1 N to 46 N) to test the linearity of the sensor value. Five subjects participated in our pilot test, which examined whether ascending and descending the stairs can be distinguished by our sensor and by weka assessment tool using k-NN algorithm. The 10-fold cross-validation method was used for analysis and the results of accuracy in identifying stair ascending and descending were 87.2% and 90.9%, respectively. By applying our sensor, the type of activity, weight-shifting patterns for balance control, and plantar pressure distribution for postural changes of the construction workers can be detected. The results of this study can be the basis for future sensor-based monitoring device development studies and fall prediction researches for construction workers.

Charge trapping characteristics of the zinc oxide (ZnO) layer for metal-oxide semiconductor capacitor structure with room temperature

  • Pyo, Ju-Yeong;Jo, Won-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.310-310
    • /
    • 2016
  • 최근 NAND flash memory는 높은 집적성과 데이터의 비휘발성, 낮은 소비전력, 간단한 입, 출력 등의 장점들로 인해 핸드폰, MP3, USB 등의 휴대용 저장 장치 및 노트북 시장에서 많이 이용되어 왔다. 특히, 최근에는 smart watch, wearable device등과 같은 차세대 디스플레이 소자에 대한 관심이 증가함에 따라 유연하고 투명한 메모리 소자에 대한 연구가 다양하게 진행되고 있다. 대표적인 플래시 메모리 소자의 구조로 charge trapping type flash memory (CTF)가 있다. CTF 메모리 소자는 trap layer의 trap site를 이용하여 메모리 동작을 하는 소자이다. 하지만 작은 window의 크기, trap site의 열화로 인해 메모리 특성이 나빠지는 문제점 등이 있다. 따라서 최근, trap layer에 다양한 물질을 적용하여 CTF 소자의 문제점을 해결하고자 하는 연구들이 진행되고 있다. 특히, 산화물 반도체인 zinc oxide (ZnO)를 trap layer로 하는 CTF 메모리 소자가 최근 몇몇 보고 되었다. 산화물 반도체인 ZnO는 n-type 반도체이며, shallow와 deep trap site를 동시에 가지고 있는 독특한 물질이다. 이 특성으로 인해 메모리 소자의 programming 시에는 deep trap site에 charging이 일어나고, erasing 시에는 shallow trap site에 캐리어들이 쉽게 공급되면서 deep trap site에 갇혀있던 charge가 쉽게 de-trapped 된다는 장점을 가지고 있다. 따라서, 본 실험에서는 산화물 반도체인 ZnO를 trap layer로 하는 CTF 소자의 메모리 특성을 확인하기 위해 간단한 구조인 metal-oxide capacitor (MOSCAP)구조로 제작하여 메모리 특성을 평가하였다. 먼저, RCA cleaning 처리된 n-Si bulk 기판 위에 tunnel layer인 SiO2 5 nm를 rf sputter로 증착한 후 furnace 장비를 이용하여 forming gas annealing을 $450^{\circ}C$에서 실시하였다. 그 후 ZnO를 20 nm, SiO2를 30 nm rf sputter로 증착한 후, 상부전극을 E-beam evaporator 장비를 사용하여 Al 150 nm를 증착하였다. 제작된 소자의 신뢰성 및 내구성 평가를 위해 상온에서 retention과 endurance 측정을 진행하였다. 상온에서의 endurance 측정결과 1000 cycles에서 약 19.08%의 charge loss를 보였으며, Retention 측정결과, 10년 후 약 33.57%의 charge loss를 보여 좋은 메모리 특성을 가지는 것을 확인하였다. 본 실험 결과를 바탕으로, 차세대 메모리 시장에서 trap layer 물질로 산화물 반도체를 사용하는 CTF의 연구 및 계발, 활용가치가 높을 것으로 기대된다.

  • PDF

Design and development of fabric-type fitness band (직물형 피트니스 밴드 디자인 및 개발)

  • Jeong, Dawun;Lee, Sojung;Kwon, Chae-Ryung;Park, Ihwa;Heo, Seowon;Kim, Dong-Eun
    • The Research Journal of the Costume Culture
    • /
    • v.26 no.4
    • /
    • pp.632-648
    • /
    • 2018
  • This study aims to contribute to the development of sports wearables. It was conducted by a convergence team of professionals in the fashion industry, kinesiology and sports studies, and computer science and engineering. The purpose of the current study was to design and develop a fabric-type fitness band for a sensor to measure acceleration during jump rope exercises. Computer science and engineering professionals developed the Arduino board and sensor, kinesiology and sports studies provided the necessary exercise protocol, and the fashion industry professionals developed the band. First, a fitness band preference survey was completed by men and women between the ages of 20 and 50. Typical uses of the band included tracking exercise amount as measured by the number of steps taken and calories burned. Strap watch closure, a single color and achromatic color, and soft and smooth touch materials were preferred as band design. Second, two fabric-type fitness bands were designed and developed. Design 1 had a 3-dimensional pocket for the sensor, bright blue color, and stretch binding around the edges and for a loop. Design 2 had a flat pocket for the sensor, achromatic color, mesh binding around the edges and two metal loops. Both designs had Velcro as a closure. Third, wear testing of both bands with the sensor were conducted of 15 women in their 20s. They wore the bands during jump rope exercises. Both bands generally satisfied the participants. The Design 2 band was slightly more satisfying than the Design 1 band.