• Title/Summary/Keyword: wear experiment

Search Result 430, Processing Time 0.026 seconds

Wear behavior of SM55C steel by rolling contact (구름접촉에 의한 SM55C의 마멸 거동)

  • Park, Beom-Su;Chae, Young-Hun;Kim, Seock-Sam
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.240-247
    • /
    • 2002
  • The rolling wear behavior of SM55C is investigated under lubrication. This is a comparative tribological behavior of heat treatment effect for SM55C. Rolling wear test method is used for Ball-on-disk type. Specimens can be classified into two main groups: as-annealing and non-annealing. As result of wear behavior, flanking initial time of non-annealing specimen keep at retard but it have not under high normal load. One of the notable features of annealing specimen is steady flanking initial time for a normal load in this experiment. Failure mechanism of SM55C is due to the fatigue wear such like flanking, pitting etc.. Flanking leads to abruptly fracture of worn surface. Fracture mechanism has a connection with normal load and polishing direction of specimens.

  • PDF

Monitoring of Tool Wear using AE Signal in Interrupted cutting (단속절삭에서 AE신호를 이용한 공구마멸의 감시)

  • 김정석
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.6 no.2
    • /
    • pp.112-118
    • /
    • 1997
  • Characteristics of AE(Acoustic Emission) signal is related to cutting conditions, tool materials, and tool geometry in metal cutting. Relation between AE signal and tool wear was investigated experimentally. Experiment is carried out by interrupted cutting for SCM420 workpiece with TiN coating tool on HSS material. AE RMS voltage and count per event were increased according to tool wear. The major results are as follows : 1) AE RMS value is nearly constant as cutting speed changes, but is rapidly increase as feed rate increases. 2) AE RMS value and Count per Event increase as tool wear increases. 3) It is more effective to monitor tool wear by Incremental rate of AE RMS value than by Incremental rate of count per event.

  • PDF

The Wear charactericstics and Machinability to The type of Cast-iron of The Slot part of cylinder for Rotary compressor (로타리압축기 실린더 Slot부의 주조조직에 따른 가공표면 및 마모특성에 관한 연구)

  • 김동한
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.77-82
    • /
    • 1998
  • The Part of slot on rotary compressor which plays an important part of the reliability and performance is studied on machinability and the wear characteristics for the specimen made by sand mold and permanent mold. The experiment are used the face cutter of milling machine which make the processing surface like broaching process and rollblock wear test machine. Permanent-mold casting iron is not affected by variation of RPM of milling machine, but sand-mold cast-iron is improved to increasing RPM. Also sand-mold casting iron shows superior wear characteristic to permanent-mold casting iron. This results from harder matrix of pearlite structure and self-lubrication characteristics of graphite. And wear particles in tested oil show shape and size similar to severe wear particles of oil taken from rotary compressor. The material and surface condition of slot play important part of the reliability and performance.

  • PDF

A study on the Wear Estimation of End Mill Using Sound Frequency Analysis (음향주파수 분석에 의한 엔드밀의 마모상태 추정에 관한 연구)

  • Cho Taik Dong;Lee Chang hee;Sohn Jang Young
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.209-212
    • /
    • 2002
  • The wear process of end mill is a so complicated process that a more reliable technique is required for the monitoring and controling the tool life and its performance. This research presents a new tool wear monitoring method based on the sound signal generated on the machining. The experiment carried out continuous-side-milling for 4 cases using the high-speed steel slot drill under wet condition. The sound pressure was measured at 0.5m from the cutting zone by a dynamic microphone, and was analyzed at frequency domain. The tooth passing frequency appears as a harmonics form, and end mill wear is related with the first harmonic. It can be concluded from the result that the tool wear is correlate with the intensity of the measured sound at tooth passing frequency estimation of end mill wear using sound is possible through frequency analysis at tooth passing frequency under the given circumstances.

  • PDF

A Study on Wear Properties of Journal Bearing with Sommerfeld Number Variation (저어널 베어링의 좀머펠트 수 변화에 따른 마모 특성에 관한 연구)

  • 김철우;김경웅
    • Tribology and Lubricants
    • /
    • v.13 no.2
    • /
    • pp.16-26
    • /
    • 1997
  • In this paper, the characteristics of lubrication and wear phenomena of journal bearing with respect to film parameter and Sommerfeld number variation are investigated experimentally and the design criterion for the hydrodynamic journal bearing is presented to avoid wear and seizure. Experimental work is performed with various rotating speed and load, and lubricant is used synthetic oil and mineral oil. By the results of the experiment, it is found that friction coefficient is decreased as Sommerfeld number is decreased, and that wear phenomenon is observed when Sommerfeld number is below $9$\times$10^{-4}$ and there are much alike in wear properties between synthetic and mineral oil.

Nanomechanical properties and wear resistance of dental restorative materials

  • Karimzadeh, A.;Ayatollahi, Majid R.;Nikkhooyifar, M.;Bushroa, A.R.
    • Structural Engineering and Mechanics
    • /
    • v.64 no.6
    • /
    • pp.819-826
    • /
    • 2017
  • The effects of thermocycling procedure and material shade on the mechanical properties and wear resistance of resin-based dental restorative materials are investigated. The modulus of elasticity, hardness, plasticity index and wear resistance are determined for the conventional composite, the nanohybrid composite and the nanofilled dental composites. Disc-shape samples are prepared from each material to investigate the effects of thermocycling procedure on the mechanical properties and wear resistance of different types of dental restorative materials. In this respect, a group of samples is thermocycled and the other group is stored in ambient conditions. Then nano-indentation and nano-scratch tests are performed on the samples to measure their mechanical properties and wear resistance. Results show that the A1E shade of the dental nanocomposite possesses higher modulus of elasticity and hardness values compared to the two other shades. According to the experimental results, the mean values for the modulus of elasticity and hardness of the A1E shade of the nanocomposite are 13.71 GPa and 1.08 GPa, respectively. The modulus of elasticity and hardness of the conventional dental composite increase around 30 percent in the oral environment due to the moisture and temperature changes. The wear resistance of the dental composites is also significantly affected by moisture and temperature changes in the oral conditions. It is observed that thermocycling has no significant effect on the hardness, plasticity index and wear resistance of the nanohybrid composite and the nanocomposite dental materials.

Analysis of Burst Pressure for Wear-Damaged Steam Generator Tubes (마멸에 의해 손상된 증기발생기 전열관의 파열압력 해석)

  • Shin, Kyu-In;Park, Jai-Hak
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.4
    • /
    • pp.16-22
    • /
    • 2003
  • Generally the rupture of steam generator tubes proceeds from significant plastic deformation before failure. In this study, the burst pressures of damaged steam generator tubes were calculated from the plastic instability analysis with the finite element method. Two wear types, flat and circumferential types were considered. An equation for the burst pressure was proposed by using the strength reduction factor and the Svensson equation. The analysis results were compared with the experiment data from published references and they showed a good agreement with the experiment data.

A Study on Tool Wear in Drilling STS 304 Steel Pipe Material (STS 304 배관재의 드릴가공시 공구마모에 관한 연구)

  • Mun, S.D.
    • Journal of Power System Engineering
    • /
    • v.5 no.3
    • /
    • pp.73-79
    • /
    • 2001
  • The purpose of this investigation is experimentally to clarify the machinability and tool wear of STS 304 steel pipe material for piping. In order to determine the effects of cutting parameters and tool wear on thrust, torque, AE RMS, drilling is conducted on CNC milling machine. In this experiment, it is measured that thrust, torque, tool wear length, tool wear area and AE RMS during drilling using Hss tool. It has been found that a) During the drilling, the thrust and the torque of the STS 304 pipe are received more the effect of the feed than the spindle speed and the thrust increase with the increase of feed, b) The value of the AE RMS is been larger the effect of the cutting speed than the feed rate, and the value of the AE RMS increase with the increase of spindle speed, c) It has been found that the suitable feed in feed condition of 0.03, 0.05, 0.1, 0.15mm/rev is below 0.05mm/rev, d) The value of the AE RMS was shown a characteristic of the jump value during it was a sudden inrcrease of the tool wear. The increased character of the AE RMS value can be known an effective factor of the tool wear detection, and e) It can be quantitatively evaluated the condition of the tool according to calculate a area of the drill wear image which is obtained by a vision system.

  • PDF

Friction and Wear Charateristic of TiAlCrN Coating on Hertz Pressure (Hertz 압력에 따른 TiAlCrN 코팅의 마찰$\cdot$마멸특성 및 수명 평가)

  • Woo Sang-Kyu;Lee Young-Ze
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.355-359
    • /
    • 2003
  • In this paper, we investigated the wear lift, wear rate, and its transition on the Hertz pressure. In the experiment, we used TiAlCrN coating deposited by the sputtering technique and ball diameter of 10mm, 7.94mm and 4.76mm for the various Hertz pressure. Ball-on-disk sliding tests wire performed under the unlubricated condition. As the diameter of a ball decreased, the failure load of TiAlCrN coating decreased. However, a good correlation was observed between the wear life and Hertz pressure, and all ball specimens showed the infinite wear life at about 450MPa. In measurement of wear rate, as the diameter of the ball inclosed, the wear transition appeared in bigger load. However, a good correlation was observed between the wear rate and Hertz pressure. The transition appeared in the range from 550MPa to 600MPa at all ball speimens.

  • PDF

The Effect of Sintering Condition On Tribological Behavior in the Cu-Base Sintered Friction Materials (동계 소결마찰재의 소결조건에 따른 마찰특성 고찰)

  • 김상호;김기열;정진현;이범주;정동윤
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.53-61
    • /
    • 1997
  • The effect of sintering condition on tribological behavior in the Cu-base sintered friction materials was studied through pin-on-disk type wear tester. Especially, the experiment was focused on making a comparative study between presstwed sintering and pressureless sintering. Pressureless sintering process showes more stable friction coefficient and lower wear rate than pressure sintering process. This result is related to pore size and density of pore in the sintered materials.

  • PDF