• Title/Summary/Keyword: wavelength band

Search Result 742, Processing Time 0.022 seconds

Estimated Temperature Error Compensation for Wavelength-Band Conversion of Infrared Image (적외선영상의 파장대역변환을 위한 추정온도 오차 보정)

  • Kim, Young-Choon;Ahn, Sang-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.11
    • /
    • pp.1270-1278
    • /
    • 2014
  • The modern infrared (IR) imaging systems use mainly one or more wavelength bands among short wavelength IR (SWIR), middle wavelength IR (MWIR), and long wavelength IR (LWIR) bands. In the process of IR image synthesis and modeling, IR image wavelength-band conversion which transforms arbitrary band image to other band one is required. The wavelength-band conversion procedure includes a temperature estimation process of an object surface. However, in this procedure, an approximated Planck's radiation equation causes errors in estimated temperature. In this paper, we propose an estimation temperature error attenuation method in IR image band conversion procedure. The estimated temperature is corrected with a slope information of radiance according to it. The corrected temperature is used for generation of the other band IR image. The verification of proposed method is demonstrated through the simulation.

Design and Fabrication of an NIR Grism Si Optical Area Sensor Spectrometer with In-band Reference Wavelength (대역 내 기준 파장을 갖는 근적외선 그리즘 실리콘 광 면 센서 분광기 설계 및 제작)

  • Song, Jae-Won
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.28-34
    • /
    • 2017
  • An NIR grism Si optical area sensor spectrometer with in-band reference wavelength is designed and fabricated. It is composed of a transmission type diffraction grating (spatial density 300 line/mm), a rectangular N-BK7 prism (apex angle 30 degree), NIR filter(cutoff wavelength 720 nm), an imaging convex lens(focal length 50 mm F1.8) and an IR modified DSLR camera (Canon EOS40D) of Si optical area sensor ($3,888{\times}2,592$ pixels, pixel size $5.710{\mu}m$). "In-band reference wavelength function" is implemented using non-dispersive 0th diffraction order optical beam. The NIR grism spectrometer is tested in a laboratory using a halogen lamp and a Neon lamp. And the spectrometer is used in an astronomy field for obtaining the planet Jupiter NIR spectrum. In-band reference wavelength i.e. un-deviation wavelength is 846 nm, an wavelength resolution is 0.3027 nm/pixel, an wavelength resolving power is 2,794 and an wavelength range is 650~1,000 nm.

Investigation of Pump Wavelength Dependence of Long-Wavelength-Band Erbium-Doped Fiber Amplifier using 1530nm-Band Pump (L 대역 EDFA 특성의 펌프 파장 의존성에 관한 연구)

  • Choi, Bo-Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.7
    • /
    • pp.1249-1255
    • /
    • 2008
  • 1530nm band has been studied as pump wavelength for long-wavelength-band erbium-doped fiber amplifier (L-band EDFA). The pump source is built using a tunable light source and cascaded conventional-band (C-band) EDFA. The L-band EDFA uses a forward pumping scheme. Within the 1530nm band, 1545nm pump demonstrates 0.45dB/mW gain coefficient, which is twice better than that of conventional 1480nm pumped EDFA. The noise figure of 1530nm pump is at worst 6.36dB, which is 0.75dB higher than that of 1480nm pumped EDFA. Such high gain coefficient indicates that the L-band EDFA consumes low power.

Performances of Erbium-Doped Fiber Amplifier Using 1530nm-Band Pump for Long Wavelength Multichannel Amplification

  • Choi, Bo-Hun;Chu, Moo-Jung;Park, Hyo-Hoon;Lee, Jong-Hyun
    • ETRI Journal
    • /
    • v.23 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • The performance of a long wavelength-band erbium-doped fiber amplifier (L-band EDFA) using 1530nm-band pumping has been studied. A 1530nm-band pump source is built using a tunable light source and two C-band EDFAs in cascaded configuration, which is able to deliver a maximum output power of 23dBm. Gain coefficient and noise figure (NF) of the L-band EDFA are measured for pump wavelengths between 1530nm and 1560nm. The gain coefficient with a 1545nm pump is more than twice as large as with a 1480nm pump. It indicates that the L-band EDFA consumes low power. The noise figure of 1530nm pump is 6.36dB at worst, which is 0.75dB higher than that of 1480nm pumped EDFA. The optimum pump wavelength range to obtain high gain and low NF in the 1530nm band appears to be between 1530nm and 1540nm. Gain spectra as a function of a pump wavelength have bandwidth of more than 10nm so that a broadband pump source can be used as 1530nm-band pump. The L-band EDFA is also tested for WDM signals. Flat Gain bandwidth is 32nm from 1571.5 to 1603.5nm within 1dB excursion at input signal of -10dBm/ch. These results demonstrate that 1530nm-band pump can be used as a new efficient pump source for L-band EDFAs.

  • PDF

Architecture of Multiple Ring based Optical Packet Network with Single Hop Between Edge Nodes (Edge Node 간 단일 홉을 갖는 다중링 기반의 광패킷 네트워크 구성)

  • 박홍인;이상화;이희상;한치문
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.386-389
    • /
    • 2003
  • This paper proposes the architecture of a multiple ring based optical network with single hop between edge nodes using either the concept of circuit switching or multi-wavelength label. The structure of the multi-wavelength label, be shown through the single wavelength-band and the multiple wavelength-band that can reduce number of ring. To avoid the collision of the optical packets at an outward port, we proposed the dynamic allocation scheme of the outward optical packets based on the fiber do]ay lines(FDLs).

  • PDF

Design and evaluation of light source for photodynamic diagnosis of cancer (광역학적 암진단을 위한 광원장치의 설계 및 평가)

  • Lim, Hyun-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.73-76
    • /
    • 2007
  • Photodynamic diagnosis(PDD) is a method to diagnose the possibility of cancer, both by the principle that if a photosensitizer is injected into an organic tissue, it is accumulated in the tissue of a malignant tumor selectively after a specific period, and by a comparison of the intensity of the fluorescence of normal tissue with abnormal tissue after investigating the excitation light of a tissue with accumulated photosensitizer. Since the selection of the wavelength band of excitation light has an interrelation with fluorescence generation according to the selection of a photosencitizer, it plays an important role in POD. This study aims at designing and evaluating light source devices that can stably generate light with various kinds of wavelengths In order to make possible PDD using a photosensitizer and diagnosis using auto-fluorescence. The light source device was a Xenon lamp and filter wheel, composed of an optical output control through Iris and filters with several wavelength bands It also makes the inducement of auto-fluorescence possible because it is designed to generate a wavelength band of 380-400. The transmission part of the light source was, developed to enhance the efficiency of light transmission. To evaluate this light source device, the characteristics of the light output and wavelength band were verified. To validate the capability of this device as PDD the detection of auto-fluorescence using mouse was performed.

  • PDF

Pump Effect by Injected C-band laser in L-band EDFA (L-band EDFA에서 주입된 C-band laser에 의한 펌프 효과)

  • 김익상;김동욱;김창봉
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.5A
    • /
    • pp.484-491
    • /
    • 2004
  • C-band pumping effect appears in L-band EDFA because the absorption in C-band occurs dominant under the condition of such a low average population inversion. In this paper, we show how the C-band pumping effect depends on 980nm pump power, the C-band wavelength, and its input power. The C-band pumping is caused by absorbing C-band injection or backward spontaneous emission power through EDF. If the same small signal condition is given by a C-band pump, the C-band pump of a long wavelength is good for the saturation and noise characteristics of L-band signal. Finally, it is considered that in the aspect of saturation characteristics, C-band compensation is not so much efficient as L-band in Gain-Clamped L-band EDFA having a lossy resonator.

Determination of Doping Density in GaAs Semiconductor by Wavelength-Dependent Photoacoustic Spectroscopy

  • Lim, Jong-Tae;Choi, Ok-Lim;Boo, Doo Wan;Choi, Joong-Gill
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.3
    • /
    • pp.895-898
    • /
    • 2014
  • The wavelength dependence of the photoacoustic signal for n-type GaAs semiconductors in the region of the band-gap energies was investigated. The significant changes in the phase and amplitude of the photoacoustic signal near the band-gap absorption wavelengths were observed to occur when the Si-doping densities in GaAs were varied. Particularly, the first derivatives of the photoacoustic phase vs. wavelength graphs were evaluated and fitted with single Gaussian functions. The peak centers and the widths of the Gaussian curves clearly showed linear relationships with the log values of the Si-doping densities in n-type GaAs semiconductors. It is proposed that the wavelength-dependent PA spectroscopy can be used as a simple and nondestructive method for measuring the doping densities in bulk semiconductors.

A Frequency Tunable Double Band-Stop Resonator with Voltage Control by Varactor Diodes

  • Wang, Yang;Yoon, Ki-Cheol;Lee, Jong-Chul
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.3
    • /
    • pp.159-163
    • /
    • 2016
  • In this paper, a frequency tunable double band-stop resonator (BSR) with voltage control by varactor diodes is suggested. It makes use of a half-wavelength shunt stub as its conventional basic structure, which is replaced by the distributed LC block. Taking advantage of the nonlinear relationship between the frequency and electrical length of the distributed LC block, a dual-band device can be designed easily. With two varactor diodes, the stop-band of the resonator can be easily tuned by controlling the electrical length of the resonator structure. The measurement results show the tuning ranges of the two operating frequencies to be 1.82 GHz to 2.03 GHz and 2.81 GHz to 3.03 GHz, respectively. The entire size of the resonator is $10mm{\times}11mm$, which is very compact.

40channel Arrayed Waveguide Grating with O.75delta% Refractive Index (0.75Δ% 굴절율차를 가진 40채널 광파장 다중화 및 역다중화 소자 제작 및 특성)

  • Moon, H.M.;Choi, G.S.;Lee, K.H.;Kim, D.H.;Lee, J.H.;Lee, D.H.;Oh, J.K;Kwak, S.C.;Kwon, O.K.;Kang, D.S.;Choi, J.S.;Jong, G;Lee, H.Y.
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.3
    • /
    • pp.196-200
    • /
    • 2005
  • A 40 channel arrayed-waveguide grating (AWG) filter operating in C-band and L-band wavelength regions has been fabricated using PLC (Planar Lightwave Circuit) processes with 0.75 refractive index difference. Its design was optimized for matching the center wavelength with the ITU-recommended wavelength. The characteristics of the fabricated C-band AWG are as follows; average insertion loss < 2.5 dB, polarization-dependent loss < 0.3 dB, non-adjacent crosstalk >35dB, and the loss uniformity of 0.8 dB. In the L-band AWG, wavelength accuracy is below 0.02nm.