Elastic Wave Characteristics of Austenitic STS202 with Subzero Treatment (서브제로 처리한 오스테나이트계 STS202의 탄성파 특성)

  • Choi, Seong-Won;Choi, Byoung-Chul;Nam, Ki-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.3
    • /
    • pp.295-300
    • /
    • 2021
  • This study investigated the dominant frequency of the elastic waves from the tensile test. The specimen was rolled with five different rolling degrees (10, 22, 33, 42 and 50%), which was treated subzero. The specimen was rolled at room temperature, which was transformed from austenite to martensite (only α'-martensite). The dominant frequency increased with an increase in the rolling degree regardless of the subzero temperature, and decreased after 33% of the rolling degree. On the other hand, higher frequency band was obtained at lower temperature and long time. The dominant frequency increased when the amount of α'-martensite increased and decreased with the α'-martensite amount between 50-65%. The lower subzero treatment temperature increased the amount of α'-martensite, which resulted in the higher dominant frequency. The longer treatment time at the same subzero temperature led to an increase in the amount of α'-martensite, leading to high dominant frequency.

Synergism Between Zinc and Taurine in the Visual Sensitivity of the Bullfrog's Eye

  • Kim, Hyun-Jung;Kim, You-Young
    • Journal of Photoscience
    • /
    • v.7 no.3
    • /
    • pp.115-121
    • /
    • 2000
  • Although there are high concentrations of zinc and taurine in ocular tissue, their exact role and correlation in the visual process are not clear. The purpose of present study was to clarity this point using electroretinogram (ERG) recording and spectrophotometer measurements before and after zinc and taurine treatment in bullfrog's eye. The optimal zinc concentration used in this study was 10$^{-2}$ M ZnCl$_2$120 ${mu}ell$/12$m\ell$ ringer solution while the optimal turine concentration was 10$^{-2}$ M taurine 12${mu}ell$/12$m\ell$ ringer solution. For the effects of zinc and taurine on the retinal function, the changes of ERG parameters (especially threshold and b-wave) and absorption spectra were observed before and after treatment. It is noteworthy that high concentrations of zinc and taurine present in the retinal pigment epithelium and the retina. Our results indicate that dark-adapted ERG threshold became elevated and the peak amplitude of b-wave was increased with zinc and taurine treatment. Furthermore there are some synergism effects between zinc and taurine as a result of co-treatment. In spectral scan, absorbance increment due to zinc and taurine treatment was shown over the whole range of spectral range (300-750 nm) with some differences in absorbance increment depending on the case of treatment. As the results of above we believe that zinc and taurine, which are abundant in the retinal pigment epithelium and the retina particularly, may be essential factors for visual process, have some synergism with each other and be required to improve the visual sensitivity during visual adaptation.

  • PDF

Effect of Transcutaneous High Frequency Wave on the Change of Tissue Temperature and Histology in Sprague-Dawley Rat (백서에서 경피적 고주파 자극에 따른 온도 변화 및 조직 변화)

  • Kim, Kyung Ah;Moon, Chang Won;Song, Da-Hyun;Kim, Sang Jun
    • Clinical Pain
    • /
    • v.15 no.2
    • /
    • pp.92-96
    • /
    • 2016
  • Objective: High frequency wave has been used in cancer treatment and cosmetic area but not in musculoskeletal pain yet. The purpose of this study is to evaluate temperature distribution according to depth and confirm safety of high frequency wave through animal study. Method: High frequency wave was applied to the posterior limb of 9 Sprague-Dawley rats for 20 minutes (experimental group) and no wave was used in the same number of rats for control group. Tissue temperature was measured from skin surface to 1 cm depth (surface, 1 mm, 5 mm, and 1 cm) for 5 seconds. Results: In the experimental group, temperature was elevated 3.2℃ at skin surface, 2.87℃ at 1 mm, 2.25℃ in 5 mm, and 1.74℃ in 1 cm depth. These were significantly different from those in the control group (p<0.001). There was no bulla or redness in the skin after high frequency wave stimulation and neither change of myocytes nor collagen degeneration was found in the tissue histology. There was no apoptosis in the skin surface and muscle layer in TUNEL assay. Conclusion: High frequency wave elevated tissue temperature from the skin to muscle layer without both histologic change and apoptosis.

Permeable Breakwaters Analysis by Using Boundary Element Method (경계요색법(境界要索法)에 의한 투과잠제(透過潛堤)의 해석기법(解析技法))

  • Kim, Nam Hyeong;Takikawa, Kiyoshi;Choi, Han Kuv
    • Journal of Industrial Technology
    • /
    • v.10
    • /
    • pp.69-72
    • /
    • 1990
  • In this paper the numerical method for the study of wave reflection from and transmission through submerged permeable breakwaters using the boundary element method is developed. The numerical analysis technique is based on the wave pressure function instead of velocity potential because it is difficult to define the velocity potential in the each region arising the energy dissipation. Also, the non-linear energy dissipation within the submerged porous structure is simulated by introducing the linear dissipation coefficient and the tag mass coefficient equivalent to the non-linear energy dissipation. For the validity of this analysis technique, the numerical results obtained by the present boundary element method are compared with those obtained by the other computation method. Good agreements are obtained and so the validity of the present numerical analysis technique is proved.

  • PDF

Tip Leakage Flow on the Transonic Compressor Rotor (천음속 회전익에서의 누설유동)

  • Park, JunYoung;Chung, HeeTaeg;Baek, JeHyun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.244-249
    • /
    • 2002
  • It is known that tip clearance flows reduce the pressure rin, flow range and efficiency of the turbomachinery. So, the clear understanding about flow fields in the tip region is needed to efficiently design the turbomachinery. The Navier-Stokes code with the proper treatment of the boundary conditions has been developed to analyze the three-dimensional steady viscous flow fields in the transonic rotating blades and a numerical study has been conducted to investigate the detail flow physics in the tip region of transonic rotor, NASA Rotor 67. The computational results in the tip region of transonic rotors show the leakage vortices, leakage flow from pressure side to suction side and their interaction with a shock Depending on the operating conditions, the position of shock-wave on the blade surface are v8y different close to the blade tip of the transonic compressor rotor. The shock-wave position dose to the blade tip had the dose relationship with the starting position of leakage vortex and the direction of leakage flow.

  • PDF

A Clinical Report of ADHD child treated with Neurofeedback theraphy (뇌파 훈련을 시행한 주의력결핍 과잉행동장애 아동의 증례 보고)

  • Jung, Myong-Suk;Kang, Hee-Chul;Lee, Seung-Gi
    • Journal of Oriental Neuropsychiatry
    • /
    • v.19 no.3
    • /
    • pp.289-297
    • /
    • 2008
  • Attention Deficif and Hyperactivity Disorder(ADHD) is a behavioral disoerder characterized by inattentiveness, impulsivity and hyperactivity, This is the case of a ADHD child treated with Neurofeedback therapy. ADHD Diagnotic System(ADS), Conner;s parent rating scale, ADHD-Rating Scale (ARS), Korean Child Behavior Checklist(K-CBCL) were compared between before and after Neurofeedback theraphy. And the EEG(Theta wave, SMR wave and Beta wave) data of each ession was analysed. As a result, Neurofeedback therapy is efficient in the treatment of ADHD.

  • PDF

A theoretical approach in 2d-space with applications of the periodic wave solutions in the elastic body

  • Ramady, Ahmed;Mahmoud, S.R.;Atia, H.A.
    • Membrane and Water Treatment
    • /
    • v.11 no.4
    • /
    • pp.295-302
    • /
    • 2020
  • In this paper, theoretical approach with applications of the periodic wave solutions in an elastic material is applied by study the effect of initial stress, and rotation, on the radial displacement and the corresponding stresses in non-homogeneous orthotropic material. An Analytical solution for the elastodynamic equation has obtained concerning the component of displacement. The variations of stresses and displacements have shown graphically. Comparisons with previously published results in the absence of initial stress, rotation and non-homogeneity have made. Finally, numerical results have given and illustrated graphically for each case considered.

A Study on the millimeter-wave stimulation on acupuncture points and it′s biological effects (경혈의 밀리파 자극과 그 영향에 관한 연구)

  • Byeon, Mi-Kyeong;Han, Sang-Whi;Kim, Jung-Kuk;Huh, Woong;Park, Young-Bae
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.129-132
    • /
    • 2002
  • In this paper, we describe a millimeter-wave radiation system developed for stimulating acupuncture points, and an analyzing system developed for monitoring the change of physiological signals after the stimulation such as ECG, skin temperature, skin potential and skin resistance. The systems are to be used to investigate the treatment efficacy and biological effects of the millimeter-wave, and eventually, can be used to study the acupuncture meridian system theory in the traditional Korean medicine.

  • PDF

Identification of Sound Source Location Generated by Shock Wave for Medical Treatment (의료용 충격파에 의해 발생하는 음원 위치의 확인)

  • 장윤석;김석재
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.453-458
    • /
    • 2003
  • When the piezoelectric extracorporeal shock wave lithotripter is operated. sounds are generated. In this paper, we present a fact that the sounds are radiated undoubtedly from the object to be hit by the shock waves. For this results. we use the method to identify the sound source location of the radiated sounds by estimating the distance and the bearing from the sound source using one hydrophone. In addition. we investigate the relation between the radiated sounds and the vibrations of the objects using bronze models of disc type with clear vibrating characteristics and present the results of experiments to be analyzed.

A Study on the Significant Point Detection Algorithm and Design of Hardware for Pulse Automatic Diagnosis (맥파자동진단을 위한 하드웨어의 설계 및 특성점 검출 알고리즘에 관한 연구)

  • Lee, J.Y.;Lee, J.W.;Lee, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2255-2258
    • /
    • 1998
  • Method of diagnosis in oriental medicine, the unbalance of the physiological function of the five viscers and six bowels of the human body is determined from time immemorial with the condition of blood circulation which is performed through blood vessels by the vitality of the heart. In oriental medicine, treatment is largely attempted by adjusting this unbalance. The analysis of pulse wave, which mainly measures the changes in blood flows, is to evaluate the shapes of a pulse wave rather than the quantitative changes like rates and strength of the pulse. This paper presents the development of Hardware System and Pulse Diagnosis Algorithm for automatic diagnosis of the pulse wave. This system makes the precise diagnosis and the objective recording possible.

  • PDF