• Title/Summary/Keyword: wave power generator

Search Result 176, Processing Time 0.022 seconds

Development of Electromagnetic Wave Immunity Test system (전자파내성시험용 측정시스템의 개발에 관한 연구)

  • 정세모;김동일;배대환
    • Journal of the Korean Institute of Navigation
    • /
    • v.20 no.2
    • /
    • pp.97-107
    • /
    • 1996
  • The method of Electromagnetic Wave Immunity Test is continuously endeavored by IEC and CISPR as international unification, but it has not been established yet. The main reason is why it is difficult to obtain the measurement method and normalization of threshold to find out the complicated parameters for Electromagnetic Wave immunity Test. So far, thus, the Electromagnetic Wave Immunity Test is carried out case by case as the electromagnetic environment, which is set up Electromagnetic Wave Immunity Test. This study has developed an algorithm and measurement software suitable for IEC1000-4 Regulations, where a ready-made Amplifier, and Signal Generator have been used and an interconnecting Interface Board has been constructed for connecting with the other apparatuses, i.e., RF Switch, Power Meter, Field Sensor, Pre-Amp., etc. Therefore, we have achieved the aim to develop an automated software using OOP method and the measurement system.

  • PDF

High voltage Pulse Transformer for Pulsed Power Supply (펄스파워전원용 고전압 펄스변압기)

  • Kim, Jong-Hae;Ku, Chi-Wuk;Choi, Y.W.;Lee, H.S.;Rim, K.H.;Ko, Kwang-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1755-1757
    • /
    • 1998
  • Pulse transformers have been developed to apply for pulsed power technology as an alternative of a Marx generator. To obtain repetitive pulsed power generation, it is necessary to observe the rising time of output of pulse transformer. In this paper, using the equivalent circuit, The rising wave of output of pulse transformer is simulated for various input wave by using the Electromagnetic transient program(EMTP).

  • PDF

Research into The Future Development of the Hybrid System for Buoy

  • Lee, Ji-Young;Kim, Jong-Do;Lee, Jong-Ho;Lee, Jin-Yeol;Oh, Jin-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.583-591
    • /
    • 2007
  • This paper reports the performance of a 150W PV-wave hybrid system with battery storage in buoy. This system was originally designed to meet a new hybrid ower system for buoy in Korea. In the case or lighted buoys and lighthouses, a light failure alarm system of wireless radio is attached so that light failures are immediately notified to the office. At lighthouse offshore fixed lights and light buoys where commercial electricity is not available, the power source depends on solar system and batteries. This power system has a various problems. Therefore energy derived from the sunshine, wind and waves has been used as the energy source lot aids to navigation. Recently a hybrid system of combining the solar, wind and the wave generator is a favorable system lot the ocean facilities like lighthouse and buoy. The hybrid system in this paper is intended for variable DC load like light, communication system in the buoy and includes a PV-wane generation system and battery. This is composed a high efficiency charging algorithm, switching converter and controller. This paper includes discussion on system reliability, power quality, and effects of hybrid system in the buoy. Simulation and experimental results show excellent performance.

High Conversion Gain Millimeter-wave Monolithic Subharmonic Mixer With Cascode Harmonic Generator (Cascode형 하모닉 발생기를 이용한 고변환이득 특성의 밀리미터파 단일칩 Subharmonic 믹서)

  • An, Dan;Kim, Sung-Chan;Sul, Woo-Suk;Han, Hyo-Jong;Lee, Han-Shin;Uhm, Won-Young;Park, Hyung-Moo;Kim, Sam-Dong;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.5
    • /
    • pp.197-203
    • /
    • 2003
  • In this paper, we have presented millimeter-wave high conversion gain quadruple subharmonic mixers adopting the cascode harmonic generator The subharmonic mixers were successfully integrated by using 0.1 ${\mu}{\textrm}{m}$ GaAs pseudomorphic HEMTs(PHEMTs) and coplanar waveguide(CPW) structures. Measured output of 1st, 2nd and 4th harmonics of the fabricated cascode 4th harmonic generator are -21.42 dBm, -32.65 dBm and -13.45 dBm, respectively, for an input power of 10 dBm at 14.5 GHz. We showed that the highest conversion gain of 3.4 dB has obtained thus far at a LO power of 13 dBm from the fabricated subharmonic mixers. The millimeter-wave subharmonic mixer also ensure a high degree of isolation showing -53.6 dB in the LO-to-IF and -46.2 dB in the LO-to-RF, respectively, at a frequency of 14.5 GHz. The high conversion gain achieved in this work is the first report among the millimeter-wave subharmonic mixers.

A Study on the Transportation Characteristics according to Beam Shape of Optical Lens Transport System using Ultrasonic Wave (초음파를 이용한 광소자 이송시스템의 빔형상에 따른 이송특성에 관한 연구)

  • Jeong, Sang-Hwa;Choi, Suk-Bong;Cha, Kyoung-Rae;Song, Suk;Kim, Gwang-Ho
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.6
    • /
    • pp.8-14
    • /
    • 2006
  • The object transport system is used in many industry field such as the conveyor belt, which transports huge goods in container harbor, the magnetic levitation system, and the indexing system which transports precision components such as semiconductor and optical components. In conventional transport system, the magnetic field may damage semiconductor and the contact force may scratch on the optical lens. So ultrasonic wave transport system has been proposed to replace the previous transport system. In this paper, the good transport condition of optical lens is obtained according to the flexural beam shapes. The working frequency and transport speed are measured and the vibration characteristics of the flexural beams are investigated by Laser Scanning Vibrometer.

Wave energy converter by using relative heave motion between buoy and inner dynamic system

  • Cho, I.H.;Kim, M.H.;Kweon, H.M.
    • Ocean Systems Engineering
    • /
    • v.2 no.4
    • /
    • pp.297-314
    • /
    • 2012
  • Power-take-off through inner dynamic system inside a floating buoy is suggested. The power take-off system is characterized by mass, stiffness, and damping and generates power through the relative heave motion between the buoy and inner mass (magnet or amateur). A systematic hydrodynamic theory is developed for the suggested WEC and the developed theory is illustrated by a case study. A vertical truncated cylinder is selected as a buoy and the optimal condition of the inner dynamic system for maximum PTO (power take off) through double resonance for the given wave condition is systematically investigated. Through the case study, it is seen that the maximum power can actually be obtained at the optimal spring and damper condition, as predicted by the developed WEC theory. However, the band-width of high performance region is not necessarily the greatest at the optimal (maximum-power-take-off) condition, so it has to be taken into consideration in the actual design of the WEC.

Characteristic Analysis of Double-sided Linear Synchronous Generator with Variable Load (양측식 선형발전기의 부하 가변에 따른 특성 고찰)

  • Jeong, Su-Kwon;Lee, Dong-Yeup;Jang, Ki-Bong;Kim, Gyu-Tak
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.41-43
    • /
    • 2008
  • This paper presents the characteristic analysis of Double-Sided Linear Synchronous Generator for wave power generation under different operating conditions. FEM is applied to analyze performance of generator at no-load and load with variable resistance. Moreover, the validity of characteristic analysis is confirmed through the experimental work.

  • PDF

Performance Improvement of Single-phase PLL Control using State Observer (상태관측기를 이용한 단상 PLL제어의 성능 개선)

  • Hwang, Hee-Hun;Choi, Jong-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.96-104
    • /
    • 2009
  • This paper proposes a single-phase Phase-locked loop (PLL) of the virtual two phase generator using full-order state observer, which is essential to find phase and frequency of the single-phase source. The conventional methods cannot remove the low-order harmonics included in source voltage, which influencesto whole PLL control system. The proposed algorithm separates fundamental wave from harmonics, and removes harmonics effectively. Therefore it generates only the fundamental wave. As it controls virtual voltage and input voltage together, it decreases steady-state error. From simulation and experimental results, the generated frequency by the proposed PLL which it plans, converges to the actual value, and the steady-state error is much reduced under given harmonic voltages. It is also confirmed that the proposed algorithm removed harmonics effectively and it generates only the fundamental wave.

Application of Secondary Control Hydrostatic Transmission in A Multi-Point Absorbing Wave Energy Converter (다수의 가동물체형 파력발전기에 있어서의 2차측 제어 정유압변속기 응용)

  • Do, H.T.;Ahn, K.K.
    • Journal of Drive and Control
    • /
    • v.11 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • This paper presents a novel concept of wave energy converter for electric generation from the ocean wave energy. In this paper, a Multi-Point Absorbing Wave Energy Converter, shortened as MPAWEC by using Secondary Control Hydrostatic Transmission (SCHST) was proposed. The power take-off (PTO) system in the proposed MPAWEC includes multi heaving buoys to drive hydraulic pumps placed at different points. The application of SCHST in MPAWEC gives some advantages, such as longevity of hydraulic components; more energy is harvested; the variation of the pressure in the accumulator limited; therefore the accumulator volume is reduced and the output speed is more stable, etc. A PID controller was designed for speed control of the hydraulic motor. The simulation results indicated that the speed of the generator was ensured with the relative error as 0.67%; the efficiency of the proposed system was 71.4%.

Experimental Studies on Ultrasonic Guided Waves for the On-Line Inspection of Structural Integrity of Nuclear Power Plants (원전 기기 건전성의 온라인 검사를 위한 유도 초음파의 실험적 연구)

  • Eom, Heung-Seop;Kim, Jae-Hee;Song, Sung-Jin;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.331-340
    • /
    • 2004
  • Deployment of an advanced on-line monitoring of the component integrity offers a prospect of improved performance, enhanced safety, and reduced overall cost for nuclear power plants. Ultrasonic guided waves have been known as one of the promising techniques that could be utilized for on-line monitoring. The present work is aimed at developing a new method for on-line monitoring of the pipes during the operation period of nuclear power plants. For this purpose, the steam generator (S/G) tube was selected as an object of tile experiment. Dispersion corves and the incident angles corresponding to the specific modes were calculated for the S/G tube. The modes of guided waves were identified by the time-frequency diagrams obtained by the short time Fourier transform. It was experimentally confirmed that there was no mode conversion when the ultrasonic guided waves passed over the curved region of the S/G tube. An optimum mode of guided wave for the S/G tube was suggested and verified by the experiment.