• Title/Summary/Keyword: wave of artery pulse

Search Result 62, Processing Time 0.025 seconds

Body Systemic Circulation Assessment Method through Analysing the Radial, Dorsalis Pedis, Temporal Arterial Pulse Wave (3부위 최적맥파의 주파(h1) 비율 분석을 통한 전체 체순환 평가방법)

  • Yu, Seung-Yeon;Park, Eun-Sung;Choi, Ye-Bin;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.33 no.3
    • /
    • pp.121-130
    • /
    • 2016
  • Objectives : Recently, people who have normal brachial blood pressure(BP) are being threatened by high-risk disease such as stroke. The aim of this study is to suggest that new method to assess systemic circulation. It can be performed by analyzing optimal blood pulse wave on 3 sites belonging to subjects that have normal BP. Methods : We respectively extracted main peaks(h1) of optimal blood pulse wave on left/right temporal artery(LR1=h1), radial artery(LR2=h1) and dorsalis pedis artery(LR3=h1). We obtained h1 from 30 subjects who are discreetly chosen and have normal BP. Main peak(h1) can be extracted by using 3D pulse imaging analyser(DMP-1000+, DAEYOMEDI Co., Korea) that has 5-level pressure method. We analyzed the ratio of [LR1/LR2] and [LR3/LR2]. Results : In the case of male group, the results are [LR1/LR2=0.7100.177] and [LR3/LR2=0.9290.317]. In the case of female group, the results are [LR1/LR2=0.6680.121] and [LR3/LR2=0.7050.195]. Especially, it is statistically verified that the result of ratio [LR3/LR2] is much higher in male group than in female group(p<0.05). Conclusions : We suggested the standard ratio of [LR1/LR2] and [LR3/LR2] for normal subjects, respectively. It can be adopted as a new method to evaluate the systemic circulation.

Measurement of a Blood Velocity by using Photoplethysmograph and Radial Artery Pulse Wave Equipped with Magnetic Hall Device (자성 홀소자 맥진기와 용적맥파계의 맥진파형을 이용한 혈류속도 측정 연구)

  • Jang, Deok-Hyeong;Kim, Dam-Bee;Choi, Suel-Gi;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.4
    • /
    • pp.130-135
    • /
    • 2012
  • One prototype product of clip-type pulsimeter equipped with magnetic field sensing semiconductor Hall device after one permanent magnet attached "Chwan" position in center of a radial artery was developed. The clip-pulsimeter was composed of the hard ware system measuring to voltage signals. To measure the blood velocity, the radial artery pulsimeter is simultaneously connected the PPG (photoplethysmograph). Analysis and comparison of two pulse waves data has done obtained from a clinical test of forty subjects of 20 ages. The value of a blood velocity simultaneously measured from a radial artery puls wave and PPG is an average value of 0.8m/s. The usage of this research results is possible to store the biomedical signals for health care.

Implementation of Intelligence Pulse Wave Detection System (지능형 맥진기 구현)

  • Hong, Y.S.;Yu, J.S.;Chang, S.J.;Sun, S.H.;Lee, W.B.;Nam, D.H.;Yu, M.S.;Choi, M.B.;Lee, S.S.
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.2
    • /
    • pp.245-254
    • /
    • 2013
  • In oriental medicine, it is possible to classify and treat many diseases using the pulse wave detection system. Other problems may arise. As it is a very subjective way to analyze the pulse wave. One problem of the conventional pulse wave detection system is that the arterial pulse sensor is not located correctly at the radial artery. Threrefore measurement results can differ depending on the measurement position and the measurement procedure. This is mostly due to it's sensitivity to high reproducibility. In order to solve this problem this paper proposes an algorithm to analyze the weak pulse wave symptom and strong pulse wave symptom. It uses the portable pulse wave detection system which includes a Hall Sensor. As a final result, it analyzed the weak pulse wave symptom and strong pulse wave symptom by the SPSS statistics technique. It proves that N time (notch point time) and S Amp (rise waveform size) mean values are significantly different in 95% confidence interval.

Effects of Acupuncture Stimulation on the Radial artery's Pressure Pulse Wave in Healthy Young Participants: Protocol for a prospective, single-Arm, Exploratory, Clinical Study

  • Shin, Jae-Young;Ku, Boncho;Kim, Tae-Hun;Bae, Jang Han;Jun, Min-Ho;Lee, Jun-Hwan;Kim, Jaeuk U.
    • Journal of Pharmacopuncture
    • /
    • v.19 no.3
    • /
    • pp.197-206
    • /
    • 2016
  • Introduction: This study aims to investigate the effects of acupuncture stimulation on the radial artery's pressure pulse wave, along with various hemodynamic parameters, and to explore the possible underlying mechanism of pulse diagnosis in healthy participants in their twenties. Methods and analysis: This study is a prospective, single-arm, exploratory clinical study. A total of 25 healthy participants, without regard to gender, in their twenties will be recruited by physicians. Written informed consent will be obtained from all participants. The participants will receive acupuncture once at ST36 on both sides. The radial arterial pulse waves will be measured on the left arm of the subjects by using an applicable pulse tonometric device (KIOM-PAS). On the right arm (appearing twice), electrocardiogram (ECG), photoplethysmogram (PPG), respiration and cardiac output (CO) signals, will be measured using a physiological data acquisition system (Biopac module), while the velocity of blood flow, and the diameter and the depth of the blood vessel will be measured using an ultrasonogram machine on the right arm (appearing twice). All measurements will be conducted before, during, and after acupuncture. The primary outcome will be the spectral energy at high frequencies above 10 Hz ($SE_{10-30Hz}$) calculated from the KIOM-PAS device signal. Secondary outcomes will be various variables obtained from the KIOM-PAS device, ECG, PPG, impedance cardiography modules, and an ultrasonogram machine. Discussion: The results of this trial will provide information regarding the physiological and the hemodynamic mechanisms underlying acupuncture stimulation and clinical evidence for the influence of acupuncture on the pressure pulse wave in the radial artery. Ethics and dissemination: This study was approved by the Institutional Review Board (IRB) of Kyung Hee University's Oriental Medical Center, Seoul, Korea (KOMCIRB-150818-HR-030). The study findings will be published in peer-reviewed journals and presented at national and international conferences. Trial registration number: This trial was registered with the Clinical Research Information Service (CRIS) at the Korea National Institute of Health (NIH), Republic of Korea (KCT0001663), which is a registry in the World Health Organization's (WHO's) Registry Network.

Development of 3-channel Pulse Wave Measurement System (3채널 맥파 측정 시스템 개발)

  • Kim, Eun-Geun;Heo, Hyun;Nam, Ki-Chang;Kang, Hee-Jung;Huh, Young
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1049-1050
    • /
    • 2008
  • It is difficult to measure the pulse wave in a short time because radial artery position and located depth are different depending on the person. In this paper, the pulse wave measurement system was developed using 3 channel piezoresistive sensor array to detect the most significant pulse wave. Augmentation Index(AI) and Heart Rate(HR) analysis are also available for predicting cardiovascular risks. The developed system is small and easy to use. And it is promising to be used as home healthcare device.

  • PDF

Development of Oriental-Western Fusion Patient Monitor by Using the Clip-type Pulsimeter Equipped with a Hall Sensor, the Electrocardiograph, and the Photoplethysmograph (홀센서 집게형 맥진기와 심전도-용적맥파계를 이용한 한양방 융합용 환자감시장치 개발연구)

  • Lee, Dae-Hui;Hong, Yu-Sik;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.4
    • /
    • pp.135-143
    • /
    • 2013
  • The clip-type pulsimeter equipped with a Hall sensor has a permanent magnet attached in the "Chwan" position to the center of a radial artery. The clip-type pulsimeter is composed of a hardware system measuring voltage signals. These electrical bio-signals display pulse rate, non-invasive blood pressure, respiratory rate, pulse wave velocity (PWV), and spatial pulse wave velocity (SPWV) simultaneously measured by using the radial artery pulsimeter, the electrocardiograph (ECG), and the photoplethysmograph (PPG). The findings of this research may be useful for developing a oriental-western biomedical signal storage device, that is, the new and fusion patient monitor, for a U-health-care system.

Development of Prediction Algorithm for Replete Pulse and Vacuous Pulse by using Clip-type Pulsimeter with Hall Device Measuring a Magnetic Field (자기장 측정 홀소자 집게형 맥진기를 이용한 허맥과 실맥 예측 알고리즘 개발)

  • Lee, Nam-Kyu;Kim, Keun-Ho;Lee, Sang-Suk;Yu, Ji-Hye;Yu, Jun-Sang;Sun, Seung-Ho;Chang, Sei Jin;Hong, Yu-Sik
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.3
    • /
    • pp.104-109
    • /
    • 2013
  • Clip-type pulsimeter equipped with Hall device and a minute permanent magnet as sensing the minute movement of a radial artery was developed. The clinical data of the 120 number of subject acquisited through the clip-type pulsimeter did treated with a typical statistical logistic regression analysis. The prediction algorithm for the replete pulse and vacuous pulse was studied. The reflective peak time and the notch peak time were major parameters to discern the replete pulse and vacuous pulse. The discrimination rate was 65%. It suggests that the logistic regression equations are possible to use the diagnosis index to predict and discern the oriental pulse wave.

Analysis of Both Hands' Two Pulse Waveforms using a Clip-type Pulsimeter Equipped with Magnetic Sensing Hall Device

  • Rhee, Jin-Kyu;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.183-187
    • /
    • 2013
  • Two concurrent signals of the pulse wave measured from both hands' radial artery in un-pressurization condition using the prototype model of two clip-type pulsimeters with a permanent magnet and Hall device are investigated. The phase differences of two pulse waves from 22 subjects have some distinct points according to the handedness. Thus, the propagation of the pulse wave calculated from phase difference is both fast and slow to each other. It is confirmed that this phenomenon comes from the difference of blood vessel hardness between right- and left-hand of each subject rather than a quantity of muscle.

A Study on the Sasang Constitutional Differences in the Pulse Wave of Korean Healthy Adult Men (한국인 성인 남성의 체질별 맥상 특성에 관한 연구)

  • Kim, Ho-Seok;Ryu, Hyun-Hee;Lee, Si-Woo
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.2 s.20
    • /
    • pp.71-74
    • /
    • 2007
  • Background : Sasang Constitutional Medicine (SCM) is the field of traditional Korean medicine that emphasize four constitutional types for diagnosis and treatment. Appearance, personalities and pathological characteristics are main factors of Sasang constitutional classification. Previous studies carried out by the pulse analyzer showed that the pulse wave can discriminate these types. In addition, It was reported that the pulse wave are affected by age and sexuality. In this study, we investigated the pulse wave characteristics related Sasang constitution types in control group regarding their age and sexuality. Subjects and Method : Two hudred and eighteen volunteers participated in this study: healthy men in $20{\sim}49$ years old. Participants were interviewed and examined to evaluate their health condition and Sasang constitution type. Then they were tested with pulse analyzer when they ere stabilized. The pulse at the radial artery just beside styloid process was measured, because this area is landmark for pulse diagnosis in oriental medicine. 3-D Mac pulse analyzer (Daeyo Medi Co. Ansan. Korea) was used in this study. We analyzed main features of pulse waves with the Sasang condtitution types by the SPSS for Windows (ver 12.0). Results : There was significant difference between Taeum and other types in contact pressure as weil as in coefficient of floating and sinking pulse. Conclusion : By analyzing pulse waves of healthy adult men. we found significant differences exist between Taeum and other types. These pulse differences may characterize Taeum type, and it will be helpful for the evaluation of Taeum type.

  • PDF

The Heart Rate Monitoring System using Inverted Photoplethysmography (반전 용적맥파 신호를 이용한 심박 모니터링 시스템)

  • Lee, Jun-Yeon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.3
    • /
    • pp.105-111
    • /
    • 2012
  • Photoplethysmogram is widely used to measure heart rate and arterial blood oxygen saturation in human. This paper describes implementation a photoplethysmography monitoring system that uses 780nm and 940nm length infrared light in radial artery. That system used combinations of 8 LEDs and 2 photoelectricities. When recorded on the skin over radial artery, the radial pulse wave was inverted. The mechanism of inverted pulse wave skin, which was reduced during systolic period and increase during diastolic period of the cardiac cycle. Through this system, we discovered optimal environments and combinations of sensors in both penetration type and reflection type. These results suggest that radial arterial wall way reflect infrared ray.