• 제목/요약/키워드: wave energy reduction

검색결과 120건 처리시간 0.022초

ESS의 전자 잡음 주파수 분석 및 제거 (Frequency Analysis and Reduction of Electronic Noise in ESS)

  • 안봉만;한병성;한운기;이영관;안현진
    • 한국전기전자재료학회논문지
    • /
    • 제35권6호
    • /
    • pp.568-575
    • /
    • 2022
  • This paper is a study on frequency analysis and electronic noise reduction of energy storage system (ESS). We acquired 4 necessary data for about 2 minutes and 4 seconds using a sampling frequency of 10,000 Hz in ESS. Fast Fourier transform (FFT) was used for electronic noise analysis from the acquired data. As a result, it was confirmed that DC component, fundamental wave, second and higher harmonic component exist. For the attenuation of harmonics, low-pass filter (LPF) was applied. We confirmed that an attenuation of approximately 59.3% appears from the second harmonic. The presence of many harmonic components in the data of the ESS was expected to occur due to the insufficiency of optimization among the modules inside the ESS. Therefore, we propose that a national certification system for ESS should be introduced to settle down the issue properly.

부유식 연직판의 규칙파 모델링을 위한 오픈폼 적용성 검토 (Investigation of Applicability of OpenFOAM for Regular Wave Modeling of Floating Vertical Plate)

  • 오상호;김건우
    • 한국해안·해양공학회논문집
    • /
    • 제29권6호
    • /
    • pp.382-388
    • /
    • 2017
  • 본 연구에서는 OpenFOAM 기반의 부유식 연직판의 파랑 저감 성능 평가 수치해석 모델링을 수행하였다. Waves2FOAM 라이브러리를 기반으로 내부조파에 의한 파랑 생성 및 스폰지층에 의한 소파 기능을 추가로 적용하였다. 이렇게 추가된 조파 및 소파 기능을 먼저 간단한 2차원 해석으로 검증한 후, Briggs et al.(2001)의 규칙파 실험자료 2가지에 대한 수치모델링을 수행하였다. 모델링 결과는 실험자료와 대체로 잘 일치하였으며, Briggs et al.(2001)에 수록된 WAMIT 수치해석 결과보다 더 좋은 결과를 나타내었다.

다공벽을 이용한 충격파 강도의 피동제어 (Passive control of strength of shock wave)

  • 최영상;권순범;조철영
    • 대한기계학회논문집B
    • /
    • 제21권1호
    • /
    • pp.174-184
    • /
    • 1997
  • A shock wave, being an irreversible process, gives rise to entropy increase. A great deal of effort has been made to control shock wave and boundary layer interaction related to energy losses as well as problems of vibration and noise. In the present study, tests are performed on a roof mounted half circular arc in an indraft type supersonic wind tunnel to evaluate the effects of porosity, length and depth of cavity in passive control of shock wave on the attenuation of shock strength by reviewing the measured static pressures at the porous wall and cavity. Also the flow field is visualized by a Schlieren system. The results show that in the present study the porosity of 8% produced the largest reduction of pressure fluctuations and that for the same porosity, the strength of shock wave decreases with the increasings of the depth and length of cavity.

FVM에 기초한 VOF법에 의한 쓰나미 수치해석 (NUMERICAL SIMULATION OF TSUNAMI WITH VOF METHOD BASED ON FVM)

  • 명현국;박진우
    • 한국전산유체공학회지
    • /
    • 제19권4호
    • /
    • pp.52-60
    • /
    • 2014
  • Recently, coastal structures have been built to protect coastal areas. However, if a tidal wave caused by an earthquake hits the coast, it would cause catastrophic damages. It is important to analyze the basics and the characteristics of a tsunami to reduce damages caused by natural disasters. In this study, a tsunami passing over different topographical changes is simulated with VOF method based on FVM(Finite Volume Method). The reduction of both scale and velocity is accomplished by similarity analysis, and an initial energy is generated by increasing the water level as needed to create a tsunami as if it is caused by a crustal movement. It is found that the present method is appropriate to simulate the tsunami with its mechanism.

THE POTENTIAL OF SATELLITE REMOTE SENSING ON REDUCTION OF TSUNAMI DISASTER

  • Siripong, Absornsuda
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.52-55
    • /
    • 2006
  • It's used to be said that tsunami is a rare event. The recurrence time of tsunami in Sumatra area is approximately 230 years as CalTech Research Group‘s study from paleocoral. However, the tsunami occurred in Indian Ocean on 26 December 2004, 28 March 2005 and 17 July 2006, because the earthquakes still release the energy. To cope with the tsunami disaster, we have to put the much effort on better disaster preparedness. The Tsunami Reduction Of Impacts through three Key Actions (TROIKA) was suggested by Eddie N. Bernard, the director of NOAA/PMEL (Pacific Marine Environmental Laboratory). They are Hazard Assessment, Mitigation and Warning Guidance. The satellite remote sensing has potential on these actions. The medium and high resolution satellite data were used to assess the degree of damage at the six-damaged provinces on the Andaman seacoast of Thailand. Fast and reliable interpretation of the damage by remote sensing method can be used for inundation mapping, rehabilitation and housing plans for the victims. For tsunami mitigation, the satellite data can be used with GIS to construct the evacuation map (evacuation route and refuge site) and coastal zone management. It is also helpful for educational program for local residents and school systems. Tsunami is a kind of ocean wave, therefore any satellite sensors such as SAR, Altimeter, MODIS, Landsat, SPOT, IKONOS can detect the tsunami wave in 2004. The satellite images have shown the characteristics of tsunami wave approaching the coast. For warning, satellite data has potential for early warning to detect the tsunami wave in deep ocean, if there are enough satellite constellation to monitor and detect the first tsunami wave like the pressure gauge, seismograph and tide gauge with the DART buoy can do. Moreover, the new methods should be developed to analyse the satellite data more faster for early warning procedure.

  • PDF

Preparation and Electromagnetic Properties of an Electromagnetic Wave Absorber

  • Sun, Chang;Sun, Kangning;Pang, Laixue;Liu, Jian
    • Journal of Magnetics
    • /
    • 제21권1호
    • /
    • pp.61-64
    • /
    • 2016
  • In this study, we report the as-prepared MgO-doped $BaFe_{12}O_{19}$, which was prepared by calcination technique and high-energy ball milling process, as an electromagnetic wave absorber. The phase analysis of $BaFe_{12}O_{19}$ and the as-prepared MgO-doped $BaFe_{12}O_{19}$ was detected utilizing X-ray Diffractometer (XRD). The microstructure was characterized using Scanning Electron Microscope (SEM). By means of the transmission/reflection coaxial line method, the electromagnetic properties and microwave absorbing properties of the as-prepared electromagnetic wave absorber were studied. It is found that the electromagnetic wave absorber has a minimum reflection loss value of -41 dB at 4.27 GHz with a matching thickness of 2.6 mm. The experiment results revealed that the as-prepared electromagnetic wave absorber could find potential applications in many military as well as commercial industries.

NDT Determination of Cement Mortar Compressive Strength Using SASW Technique

  • Cho, Young-Sang
    • KCI Concrete Journal
    • /
    • 제13권2호
    • /
    • pp.10-18
    • /
    • 2001
  • The spectral analysis of surface waves (SASW) method, which is an in-situ seismic technique, has mainly been developed and used for many years to determine the stiffness profile of layered media (such as asphalt concrete and layered soils) in an infinite half-space. This paper presents a modified experimental technique for nondestructive evaluation of in-place cement mortar compressive strength in single-layer concrete slabs of rather a finite thickness through a correlation to surface wave velocity. This correlation can be used in the quality control of early age cement mortar structures and in evaluating the integrity of structural members where the infinite half space condition is not met. In the proposed SASW field test, the surface of the structural members is subjected to an impact, using a 12 mm steel ball, to generate surface wave energy at various frequencies. Two accelerometer receivers detect the energy transmitted through the medium. By digitizing the analog receiver outputs, and recording the signals for spectral analysis, surface wave velocities can be identified. Modifications to the SASW method includes the reduction of boundary reflections as adopted on the surface waves before the point where the reflected compression waves reach the receivers. In this study, the correlation between the surface wave velocity and the compressive strength of cement mortar is developed using one 36"x36"x4"(91.44$\times$91.44$\times$91.44 cm) cement mortar slab of 2,000 psi (140 kgf/$\textrm{cm}^2$) and two 36"x36"x4"(91.44$\times$91.44$\times$91.44 cm) cement mortar slabs of 3,000 psi (210 kgf/$\textrm{cm}^2$).

  • PDF

왕복동식 압축시스템에 연결된 파이프 내부의 유동특성에 관한 CFD와 실험 (CFD and Experimental Study of Gas Flow Inside the Steel Pipe Fitted in Reciprocating Hydrogen Compression System)

  • 라흐만;이경환;이광성;정한식;정효민
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1513-1520
    • /
    • 2009
  • Renewability and pollutant free energy source makes hydrogen energy popular rapidly. Hydrogen gas pressure which is after passing through reciprocating compressor part has high pulsation wave form. A unit, snubber is used as compressor components to reduce the harmful pulsation waveform and to remove the impurities in the hydrogen gas. An experiment has been conducted to investigate the pulsation reduction performance of a steel pipe used in snubber system. The amplitude of pressure reduction were varied from $0.054{\sim}0.321\;kPa$ for 10 hz to 60 hz motor speed. Compressor operation by motor with 10 to 60 hz were resulted in reduction of pressure pulsation from 16.415% to 35.151%. Pressure losses were varied from $0.001%{\sim}0.759%$, and pressure drop per centimeter of the steel pipe were varied from $0.0160{\sim}16.03\;Pa$.

  • PDF

배후수위 저감효과를 가진 신기능 잠제의 개발 (Development of New Type of Submerged Breakwater for Reducing Mean Water Level behind Structure)

  • 허동수;이우동;구남헌;전호성;정연명
    • 한국해양공학회지
    • /
    • 제31권2호
    • /
    • pp.130-140
    • /
    • 2017
  • Typically, a submerged breakwater is one of the good scene-friendly coastal structures used to reduce wave energy and coastal erosion. However, sometimes, a submerged breakwater also has a negative aspect in that a strong rip current occurring around an open inlet due to a difference in mean water levels on the front and rear sides of the structure leads to scouring. Such scouring has a bad effect on its stability. In order to eliminate this kind of demerit, this study investigated four new types of submerged breakwaters with drainage channels. First, hydraulic experiments were performed the typical and new structures. Then, the wave height and mean water level distributions around the structures were examined using the experimental results. Finally, it was revealed that the new type of submerged breakwater could efficiently reduce the mean water level on its rear side. In particular, in the case of new-type submerged breakwater 2, an average reduction efficiency of 71.2% for the difference between the mean water levels at the front and rear sides was shown in comparison with the typical one.

수치해석을 통한 규칙파를 받는 후부 패러핏 케이슨 방파제의 안정성 평가 (Stability Evaluation of Rear-Parapet Caisson Breakwaters under Regular Waves by Numerical Simulation)

  • 이병욱;박우선;안석진
    • 한국해안·해양공학회논문집
    • /
    • 제32권2호
    • /
    • pp.95-105
    • /
    • 2020
  • 본 연구에서는 CADMAS-SURF 모형을 사용하여 케이슨 직립제의 상부에 패러핏의 설치 위치에 따라서 규칙파에 의한 파압과 파력의 특성을 분석하였고, 파력결과를 사용하여 방파제 및 지반 안정성 평가를 수행하였다. 수치해석결과, 후부 패러핏을 채택하면 전면 최대 파압 및 파력을 저감시킬 수 있으며, 패러핏에 작용하는 최대 파압은 전면에 있는 경우에 비하여 다소 증가하나 전면 최대 파압과의 위상차에 의해 방파제의 안정성에는 거의 영향을 미치지 못함을 확인하였다. 그리고 Yamamoto et al.(2013)이 후부 패러핏의 문제점으로 지적한 바 있는 충격파압은 발생하지 않았다. 활동, 전도에 대한 안정성 검토 결과, 후부 패러핏 구조를 채택하면 항외측에 패러핏을 설치한 경우에 비하여 13% 적은 자중으로도 목표 안전율인 1.2를 확보할 수 있는 것으로 평가되었다. 이때 최대 지반지지력도 30% 감소되는 것으로 확인되어 후부 패러핏 구조의 실제 현장에서의 적용성이 높은 것으로 평가되었다.