• Title/Summary/Keyword: water-treatment

Search Result 12,111, Processing Time 0.044 seconds

Overcapacity of Water Treatment Plants in Korea (국내 정수장 과다시설용량 실태 분석)

  • Lee, Sangeun;Park, Heekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.1
    • /
    • pp.57-67
    • /
    • 2009
  • Under the supply-oriented policy, efficiency and rationale have not been fully considered in planning of water supply facilities in Korea. As a case, this study shows that large-size systems are suffering from overcapacity problem of water treatment plants, and thus discusses what options should be applied to deal with inefficiency. Water demand of large-size systems has suddenly decreased for the last 10 years while water demand has been often assumed to increase at a regular rate in planning of plants according to excess capacity hypothesis. This inconsistency led to a serious overcapacity. In 2006, total excess capacity of nine large-size systems was more than 1.2 times as large as maximum daily demand of total customers in Seoul. However, their options are expected to stay ex post facto. To prepare the risk of overcapacity, and draw large benefits out of the plants, the authors and other professionals in Korea should further discuss the more adaptive method for prediction of water demand, and systems integration between a large-size system and adjoining systems.

Changes in Water Absorption, Water-holding Capacity, Chromaticity and Mineral Contents of Dried Sea Mustards on Soaking (건미역의 수침에 따른 흡수율과 보수율, 색도 및 무기성분의 함량 변화)

  • ;;;南出隆久
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.11 no.3
    • /
    • pp.209-218
    • /
    • 2001
  • This study was conducted to examine the water absorption, water-holding capacity, color and mineral contents in natural and cultured dried sea mustards on soaking treatment. Four dried samples of natural and cultured sea mustards were used for the experiments. The effects of soaking treatment on water absorption and water-holding capacity in sea mustards were examined, as the results, these were rapidly accelerated 5 minutes after soaking. It showed that water-holding capacity was significantly high in the case of high absorption of water by soaking. The L, a and b values were increased until 30 minutes after soaking. There was significant difference for potassium content between dried natural and dried cultured sea mustards and the natural sea mustard was 10 times as high as the cultured sample. All mineral elements in these materials were significantly decreased and especially, potassium were significantly more decreased at 50~80% of total content by soaking treatment. Ca/ P ratio in these materials by soaking was about 2~3 : 1 levels.

  • PDF

A Study about Applicability of Treatment for Backwash Water Using Tubular Membrane System with Dead-End Operation Mode (역세 배출수 처리를 위한 관형막의 전량여과 운전 적용에 대한 연구)

  • Eom, Jung Yeol;Kim, Kwan Yeop;Kim, Young Hoon;Song, June Sup;Kim, Hyung Soo;Han, Myung Ae;Yang, Hyung Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.4
    • /
    • pp.437-444
    • /
    • 2008
  • Many other countries have investigated the new backwash water treatment process to save the existing water resource. There are various methods for reusing backwash water, but the membrane system has received the most interest for its efficiency. The objective of this study was to certify the application of membrane filtration system for the backwash water treatment. The experiment equipment was composed of Lab scale tubular membrane filtration system. Generally, cross-flow operation mode is used in the tubular membrane system but cross-flow operation mode demands high electric cost mainly for the pump energy. So to cut off electric cost, dead-end operation mode was used in this experiment. Filtration and bleed operation cycle was used in this membrane system. Backwash water was concentrated during the filtration process and when backwash water reached our target suspended solid concentration, it was discharged from this system. For efficient operation of filtration and bleed, mathematical matrix was drawn up and with this matrix we could simulate various sets of filtration and bleed time.

A mini-review on discharge characteristics and management of microplastics in sewage treatment plants (국내·외 연구사례를 통해 본 하수처리시설 미세플라스틱 배출특성 및 관리방안 고찰)

  • Jeong, Dong-Hwan;Ju, Byoungkyu;Lee, Wonseok;Chung, Hyenmi;Park, Junwon;Kim, Changsoo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.4
    • /
    • pp.337-348
    • /
    • 2018
  • As the issue of microplastics (MPs) detection in tap water was raised in other countries in 2017, monitoring of MPs in drinking and source water, and sewage treatment plant (STP) effluents was initiated. This study intends to look into other studies on MPs in STPs at home and abroad, and review the characteristics of MPs and their removal efficiencies in the STPs, the risk and effect of MPs on watersheds, and management practices in order to help better understand MPs in STPs. To manage MPs effectively in STPs, it is necessary to investigate the detection of MPs discharged from STPs, do research on human health risk and control measures, and build a monitoring system including standardized analytical methods.

Study in the integrated watershade management for conservation of water resources (II) - Water quality modeling and simulation of Oship stream - (수자원 보전을 위한 유역통합관리 방안에 관한 연구(II) - 오십천 수계의 수질모델링 및 수질 예측 -)

  • 허인량;정의호;권재혁
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.61-69
    • /
    • 2002
  • Oship stream is located nearby south eastern coasts. This study was performed to find out waters quality modeling and then to predict water quality of Oship stream. Based on survey data, BOD, T-N, T-P calibration and verification result were in good agreement with measured value within mean coefficient variance(MSE) value, which were 13.9%, 9.0%, 26.5% and 19.5%, 12.0%, 16.5%, respectively. Sectional water quality predictions of the main stream of Oship stream are executed on the basis of the following cases 1) with sewage treatment of Dogye-eup 2) reduction of mine wastewater treatment of 80% in th basin. As a result, BOD, T-P improvement rates at down stream of Oship stream, case 1) were appeared 12.2%, 22.2%, case 2) maximum sulfate ion and conductivity reduction removal rate of Oship stream were 58%, 68%. The main pollution sources of Oship-stream were almost domestic wastewater and mine wastewater discharged from Dogye-eup which located in uppers stream. The large effects will appear after the construction of Dogye sewage water treatment plant which remove the organic matter and nutrients in these sewage water. The waste water from mine can not easily to treat for characteristics of effluence and economic problems. However, to achieve the goal of water quality in Oship-stream water system, treatments of those are necessary.

Water Treatment Process for Removal of Free Ammonia in Bank Filtrated Water (암모니아성 질소제거를 위한 강변여과수에서의 수처리 공정)

  • Choo Tae-Ho;Lee Jung-Suk
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2005.11a
    • /
    • pp.123-128
    • /
    • 2005
  • Buk-myeon area in Changwon is located near Nakdong river and not short of quantity of river but the water quality and quantity is changed extremely by seasons, and Fe, Mn, Cu are found at the base rock underground water. Therefore, bank filtrated water developing is settled. At this research, Pilot-Plant is built to find out Fe and Mn are detected and eliminated by biological process and the ammonia is exceeded the drinking water quality criteria at the bank filtrated water while designing and facilitating the local water supply facilities at Buk-myeon area. Also, check results of the changed treatment process of automatic precipitating filter, which is producing and supplying drinking water, and analyzing the Biological Process Effectiveness by building and running Buk-myeon Water Treatment Facility, which could provide $10,000m^3/day$.

  • PDF

Effects of Water Deficit on Biomass Accumulation and Water Use Efficiency in Soybean during Vegetative Growth Period

  • Kim, Wook-Han;Hong, Byung-Hee;Larry C. Purcell
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.45 no.1
    • /
    • pp.6-13
    • /
    • 2000
  • Water deficit is the primary constraint of soybean [Glycine max (L.) Merr.] yield, and a physiological understanding of processes affected by water deficit is a key step in identifying and improving drought tolerance in soybean. The objectives of this research were to evaluate biomass and nitrogen accumulation patterns and water use efficiency (WUE) as possible mechanisms associated with the drought tolerance of Jackson. Biomass accumulation of Jackson was contrasted with the PI416937, which also has demonstrated tolerance to drought. For water-deficit treatment, total biomass accumulation was negligible for PI416937, but biomass accumulation continued at approximately 64 % of the well-watered treatment of Jackson. Transpirational losses for Jackson and PI416937 were approximately the same for the water-deficit treatment, indicating that Jackson had superior WUE. Isotopic discrimination of $^{13}$ C relative to $^{12}$ C also indicated that Jackson had higher WUE. Results indicated that increased WUE for Jackson under water deficit showed it was tolerant to drought rather than had an avoidance mechanism.

  • PDF

Analysis of the cost effectiveness according to T-P standard enforcement of public sewage treatment facilities (공공하수처리시설의 총인기준 강화에 따른 비용효과분석)

  • Jeong, Won-Gu;Rim, Jay-Myung
    • Journal of Industrial Technology
    • /
    • v.31 no.A
    • /
    • pp.135-145
    • /
    • 2011
  • This study was conducted to analyze the cost effectiveness in line with total phosphorus standard enforcement of public sewage treatment facilities. The additional cost for the total phosphorus removal process was calculated to analyze the cost effectiveness of the advanced water purification process. The analysis results showed that the T-P removal by coagulation sedimentation was more efficient than the advanced water purification facilities in terms of facilities investment cost, and if the coagulation filteration was used for T-P removal, the activated carbon process among the advanced water purification techniques was more efficient in terms of facilities investment cost. In this study, the effects of the T-P removal process that will be additionally introduced according to the tightening of the effluent T-P standard were analyzed within a limit. The actual benefits of improved T-P concentration in the water source will provide diverse values, including the leisure water, environment improvement water, eco-system in the water source and industrial water, in addition to the advanced water purification.

  • PDF

A Study on Surface Tension Measurement for the Water through Electro-Magnetic Field (전자장을 통과한 물의 표면장력 측정에 대한 연구)

  • 고영하
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.7
    • /
    • pp.826-831
    • /
    • 2003
  • The purpose of this study was to measure the surface tension of hard water through electro-magnetic field for investigating the effect of electro-magnetic water treatment. The maximum reduction of surface tension was 8% comparing to the no treatment case. When the flow velocity through the permanent magnetic device (PMD) was 6.3 m/s, sample of hard water had the minimum surface tension.

PORE WATER PRESSURE IN SAND BED UNDER OSCILLATING WATER PRESSURE

  • HoWoongShon
    • Journal of the Korean Geophysical Society
    • /
    • v.6 no.2
    • /
    • pp.57-69
    • /
    • 2003
  • In this paper the theoretical method to analyse the pore water pressures in the bed under the oscillating water pressure is developed. In the former researches the validity of the theoretical treatment for the one-dimensional problem has been verified. However, the one-dimensional treatment is not sufficient to obtain the precise information concerning the many practical problems. From this point of view, in this study, we derive the fundamental equations for the general three-dimensional sand layer under the oscillating water pressure. The validity of this theoretical method is verified by experiments for the two-dimensional problems.

  • PDF