• Title/Summary/Keyword: water-treatment

Search Result 12,111, Processing Time 0.042 seconds

Water Treatment Characteristics by Const ucted Wetland with Different Vegetation - Open Water Arrangements (식생습지와 개방수역의 배열에 따른 인공습지의 수처리 특성)

  • Jang, Jeong-Ryeol;Choi, Sun-Hwa;Kwun, Soon-Kuk
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.1
    • /
    • pp.122-130
    • /
    • 2007
  • This study was conducted to evaluate water treatment characteristics according to vegetated wetland(V) and open water(O) arrangements in free water surface constructed wetland. Three pilot-scale wetlands, V-V, O-V and V-O, were built and operated. $BOD_5$ was a slightly reduced at all the arrangements because the influent concentration was so low as background concentration of constructed wetlands. While T-N and T-P removal efficiency showed higher than 50% for all cases. The O-V arrangement showed the highest removal efficiency: 20% for $BOD_5$, 56% for SS, 59% for T-N and 72% for T-P. Effluent concentration of the O-V were significantly low compared with those from the V-O. O-V arrangement would be beneficial in the light of pollutant removal efficiency as well as construction cost.

Advanced Lake Water Treatment with Bipolar Packed Bed Electrode Cell(II) (3차원 전극(Bipolar Packed Bed Electrode)을 이용한 호소수 처리(II))

  • 장철현;박상우;최창수
    • Journal of Environmental Science International
    • /
    • v.11 no.4
    • /
    • pp.355-360
    • /
    • 2002
  • This study was to analyze the right of wrong of gray-water treatment by applying BPBE electrode cell to the effluence water in the terminal disposal plant of sewage. The results were as follows : The best result was obtained with applied voltage 40V and detention time 6 minutes for the BPBE electrode cell which has the graphite-plate in main electro-de, packing coconut activated carbon. The elimination rate of COD of Al-plate was higher than that of graphite-plate in main electrode. The result of electrolysis for 3 hour in parallel circuit showed the using possibility of gray-water according to each elimination rate : COD 59%, T-N 69 %, T-P 69%. The BPBE electrode cell with the Al-plate in main electrode made the best effect for the elimination of algae in lake water and algae were not occurred in electrolytic water.

The Effect of Branches on Kumho River's Water Quality (지류의 수질이 금호강 본류의 수질에 미치는 영향에 관한 연구)

  • Yang, Duk Seok;Bae, Hun-Kyun
    • Journal of Environmental Science International
    • /
    • v.21 no.10
    • /
    • pp.1245-1253
    • /
    • 2012
  • In this study, how branches of Kumho River affect to the water quality on Kumho River was investigated. Water samples from six sampling points at Kumho River and three at each branch were taken from Dec. 2009 to Dec. 2011. As results, Namcheon affected BOD and T-P concentrations on Kumho River while Sincheon did only T-P concentrations. However, the water quality of Kumho River was improved because of Sincheon in terms of BOD and COD concentrations. This was the results from management of Sincheon wastewater treatment facility and Jisan wastewater treatment facility which might be the best example for managing wastewater treatment facilities. Dalsecheon would not affect the water quality of Kumho River although it had bad conditions of water quality because of lack of its water quantity comparing to Kumho River's.

Analysis on the effect of harmonics filter applied to water treatment facilities (고조파 저감장치 현장적용 효과 분석)

  • Lee Eun Chun;Byun Il Hwan;Shin Gang Wook;Hong Sung Taek;Lee Eun Woong
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.273-275
    • /
    • 2004
  • Recently, many water treatment facilities are operated by automatic control or by remote control. These high technology control systems require more stable power supply than before Badly most automatic control systems adopted in water treatment facilities are non-linear load which generates electrical harmonics inevitably. This study is intended to measure and analyze the electrical harmonics occurred at the chemicals control device which is inverter application circuit. and to show the effect of the harmonics filter.

  • PDF

Analysis on the Actual Conditions of Wastewater Treatment Facilities in Chungcheongnam-do Province Industrial Complexes (충청남도 산업단지의 오·폐수처리실태 분석)

  • Lim, Bong-Su;Kim, Do-Young;Yi, Sang-Jin;Oh, Hye-Jung
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.850-862
    • /
    • 2007
  • This study was carried out to survey the actual conditions of wastewater treatment facilities to obtain basic data for the management of wastewater from industrial complexes in Chungcheongnam-do province. Wastewater production flow per site area by watersheds was $49.2m^3/km^2/d$ for Sapgyoho, $8.1m^3/km^2/d$ for Anseongcheon, $5.7m^3/km^2/d$ for Seohae, and $2.9m^3/km^2/d$ for Geumgang. Sapgyoho showed 75% of the total production flow, which was the highest value, Geumgang showed 4% of total flow, which was the lowest value. Average total extra rate as production flow/capacity flow in the wastewater treatment facilities for industrial complex is 49%. Considering by watersheds, the extra rates of Seohae, Geumgang, Anseongcheon, and Sapgyoho, are 73%, 65%, 62%, and 33% respectively. This means that the design of capacity flow in wastewater treatment facilities was too large. Effluent concentration of wastewater treatment facilities did not exceed discharge limit mostly. The removal efficiency rate for water quality item was 90% in BOD, 70% in COD, 80% in SS, 30 to 80% in TN, and 20 to 90% in TP, so the organic removal was good, but the nutrient removal was low and interval of variation was high. The removal efficiency rate of the agricultural was industrial complexes is lower than the national and local complexes. The construction cost of the wastewater treatment facilities in Chungcheongnam-do was $1,756Won\;per\;m^3$, treatment cost was $189Won\;per\;m^3$, and they were about two times and 1.2 times higher than the nation-wide cost, respectively. The treatment cost consists of 39% for man power, 21% for chemical, 16% for power, 11% for sludge treatment, and 13% for others.

Water Quality Prediction of the Mankyung Water Shed according to Construction of New Sewage Treatment Facilities (하수처리시설 신설에 따른 QUAL2E모델에 의한 만경수계 수질예측)

  • Chung, Paulgene;Hyun, Mihee;Jung, Jinpil
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.2
    • /
    • pp.200-207
    • /
    • 2010
  • The sewage treatment plants to be built to improve the water quality of the Mankyung River will total 11, of which combined capacity will reach $39,850m^3/day$, and saying in detail, 5 at Gunsan city, 2 at Iksan city, 1 at Kimje city and 3 at Wanju gun, The scenario for water quality improvement was developed, considering the conditions of plant operation ratio and the accomplishment of the water quality target (BOD 4.4 mg/L, T-P 0.356 mg/L) at the end of the watershed of Mankyung B was predicted, making use of QUAL2E model. As a result of prediction using QUAL2E model based on scenarios with 70% and 100% of operation ratio, respectively, at 11 plants in 2010, the water quality at the watershed of Mankyung B was estimated at 4.322 mg/L which was lower than the target of BOD 4.4 mg/L, indicating the target water quality was achieved, when it comes to 70% of operation ratio, But in case of T-P, it was estimated at 0.565 mg/L, which was higher than the target. When it comes to 100% of operation ratio, T-P also was 0.563 mg/L which exceeded the target, 0.356 mg/L. As indicated above, the effect of water quality improvement appeared very insignificant, which was attributable to the limit of small scale sewage treatment plant in total reduction capacity. Hence, the measures for additional reduction in a bid to achieve the target water quality of T-P at the designated location need to be taken, and the measures to build the Sewage treatment facilities at the place where the pollution is significantly caused by T-P appeared to be required as well.

A study on Determination Method of the Compliance Concentration of Effluent Limitation from Public Sewage Treatment Works in the Jinwee-stream Watershed Sewer System (유역하수도 공공하수처리시설의 방류수 수질 준수농도 설정방안 연구: 진위천 수계를 중심으로)

  • Jeong, Dong-Hwan;Cho, Yangseok;Kim, Youngseok;Ahn, Kyunghee;Chung, Hyen-Mi;Kwon, Ohsang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.4
    • /
    • pp.493-502
    • /
    • 2015
  • In accordance with the Watershed Sewer System Maintenance Plan enforced on February 2, 2013, the different compliance concentration of effluent limit be applied to effluent discharged from public sewage treatment works(PSTWs) in each watershed on the basis of water quality thereof. With the introduction of watershed sewer system, it is necessary to set the compliance concentration of effluent limit for PSTWs situated in the watershed, by region and PSTW size, to achieve water quality criteria for regional watersheds or target water quality under TMDL program. Watershed Environmental Agencies establish the Watershed Sewer System Maintenance Plan and set the compliance concentrations of effluent limit for PSTWs under the plan. The agencies plan to apply tougher effluent BOD concentration limits in Class I to IV areas. Effluent BOD concentration limits will be toughened from 5~10 mg/L to 3 mg/L in class II~III areas, from 10mg/L to 5mg/L in class IV areas. Uniform application of effluent BOD concentration limits to PSTWs in the watershed sewer system need to be complemented considering type of sewage treatment technology employed and watershed characteristics. Therefore, this study presents method to determine the compliance concentration of effluent limit from PSTWs in the watershed.

Effects of Germinating Types of Water-soaking & Air-exposure and Chitosan Treatment on Brown Rice Germination (침수 및 대기 발아방식과 키토산 처리가 현미발아에 미치는 영향)

  • Lee J.;Lim K.T.;Hong J.H.;Rhee C.O.;Choi Y.S.;Lee Y.B.;Choi S.M.;Chung J.H.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.4 s.117
    • /
    • pp.363-368
    • /
    • 2006
  • The effects of germinating types and treatments of acetic acid, water-soluble and water-insoluble chitosan on the germination ratio and sprout length of brown rice were investigated in this study. The treatment of 0.001% acetic acid improved the germination ratio and sprout growth of brown rice in the germinating types of a air-exposure method after water-soaking (Type II) and a repetitive method of water-soaking & air-exposure (Type III), not water-soaking method (Type I). The treatment of water-soluble chitosan with higher concentration caused higher germination ratio and faster sprout growth. The treatment of water-insoluble chitosan repressed the germination and the sprout growth of brown rice. The germination ratios of brown rice germinated by the Type III were higher than those by Type I and Type II for all the treatments of acetic acid and water-soluble & water-insoluble chitosan as more than 97% germination ratio. Also, the Type III method accelerated the sprout growth of brown rice compared with Type I and Type II.

Element Technology and Strategy of Digital Twin in the Water Treatment (수처리공정의 디지털 트윈 요소기술과 추진 전략)

  • Young-Man Cho;Yong-Jun Jung
    • Journal of Wetlands Research
    • /
    • v.25 no.4
    • /
    • pp.284-290
    • /
    • 2023
  • Domestic water supply and sewage facilities are rapidly aging and maintenance difficulties such as aging of operation and management personnel are overlapping, so Digital Twin technology is attracting attention as an intelligent means of process management. Digital twin projects for domestic water treatment processes include the smart sewage treatment project promoted by the Ministry of Environment, projects independently promoted by some local governments, and digital twin purification plant projects promoted by K-water. However, the content of digital twin promotion is different for each institution. Therefore, in the water treatment process, technological standardization and step-by-step implementation methods for digital twins must be preceded to reduce trial and error in future business promotion. This study aims to provide an efficient promotion plan by prescribing the digital twin element technology and composition method in the water treatment process and reviewing the contents currently being promoted by the Ministry of Environment, local governments, and K-Water individually.

Study on the alternatives to trace the origin and to diminish the sediments of drinking water (수돗물의 앙금발생규명 및 저감기술방안)

  • 김갑수;임병진;권은미
    • Journal of environmental and Sanitary engineering
    • /
    • v.9 no.1
    • /
    • pp.17-28
    • /
    • 1994
  • There are many possibilities that may lead to low quality of drinking water Recently, some unknown deposits in tap water raised a lot of public concern regarding the safety of drinking water in Seoul. We analyzed the quality of tap water from several areas of Seoul, including the area where public complaints about tap water were high. The results shows that the quality of tap water in Seoul was good, well below the environmental standards. Only the tap water from the area with high public complaints showed turbidity higher than that of other area. Also, result shows that component of deposit in tap water was Al, Fe, Mn, and Zn. Based on the research result we propose several measures that might help to reduce the amount of deposit in tap water as follows : 1 Using coagulant aid when coagulating or adjusting pH when filtering. 2. Replacing old water pipeline with new corrosive- resistant one. 3. Increasing water treatment efficiency by enhancing water treatment system such as automation of water treatment system adjusting production capacity, and improving operational condition of filler basin. 4. Chlorine disinfection at the distribution reservoir would help maintaining the same pH level and chlorine concentration throughout the water pipeline and reduce corrosion of pipe.

  • PDF