• Title/Summary/Keyword: water-damaged

Search Result 680, Processing Time 0.027 seconds

The remote-sensing based estimation of the evapotranspiration change due to the 2019 April Gangwon-do wildfire (2019년 강원도 산불로 인한 증발산 변화 원격탐사기반 추산)

  • Kim, JiHyun;Sohn, Soyoung;Kim, Yeonjoo
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.11
    • /
    • pp.941-946
    • /
    • 2019
  • A wildfire could significantly alter the local hydrological regime, depending on the area and severity, and thus it is critical to understand its effect and feedback using data and simulation. For the wildfire in Gangwon-do on April 4-5, 2019, South Korea, we retrieved the Normalized-Burned Ratio (NBR) index using remote-sensing data (500-m 8-day MODIS surface reflectance data), and detect the damaged-area based on the difference in the NBR (dNBR) before and after the fire. The damaged area was $29.50km^2$ in total, taking up 1.00-6.19% of five catchments. We then used remote-sensing data (500-m 8-day MODIS evapotranspiration data) and estimated that annual evapotranspiration (AET) would decrease as 0.05-1.56% over the five catchments, as compared to the pre-fire AET (2004-2018). This study highlights the importance of improving our understanding about the impact of wildfire on the local hydrological cycle.

What Can Radiation Protection Experts Contribute to the Issue of the Treated Water Stored in the Damaged Fukushima Daiichi Nuclear Power Plant?

  • Yamaguchi, Ichiro
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.1
    • /
    • pp.24-31
    • /
    • 2021
  • Decommissioning efforts are underway at the reactor where the accident occurred, namely the damaged Tokyo Electric Power Company (TEPCO) Fukushima Daiichi Nuclear Power Plant (FDNPP). However, a large amount of groundwater flowing into the site has become contaminated with radioactive substances and is stored in tanks on site, which has hampered the decommissioning work. Although the inflow of groundwater has been greatly reduced through measures such as the construction of frost walls, approximately 170 ㎥ of water treated by the Advanced Liquid Processing System (ALPS) is being stored in tanks, each day. The tanks used to store this treated water are expected to become full by around the summer of 2022. It is not easy to get people to understand the efforts of all concerned parties, and providing clear information to these concerned parties is also a challenge. Questions have also been raised regarding whether other alternatives have been fully explored in the ALPS subcommittee. Some people have commented that the answers to the questions raised regarding the biological effects of tritium transmutation are inadequate. Some suspect that the answers are too detailed and incomprehensible, and that the respondents may be manipulating the public with some malicious intent. In any case, each possible plan presents both advantages and disadvantages, depending on the people who are involved. That makes it an ethical and vexing issue that can sway decisions, as perspectives change. While the environmental release plan is scientifically safe, it may represent a painful alternative. On the other hand, a more careful and imaginative approach to the idea of continued storage in tanks or other forms of storage may reveal some troublesome hidden disadvantages. Under these circumstances, experts must be prepared to answer people's questions in a comprehensive and robust manner.

Characteristics of Salt Tolerance in Woody Species (III) -Effects of Salt Treatment on Physiological Responses in the Leaves of Several Tree Species- (수종간(樹種間)의 내염력특성(耐鹽力特性)에 관(關)한 연구(硏究)(III) - 몇 수종(樹種)에 대(對)한 염분처리(鹽分處理)가 엽(葉)의 생리적(生理的) 반응(反應)에 미치는 영향(影響) -)

  • Choi, Moon Gil
    • Journal of Korean Society of Forest Science
    • /
    • v.77 no.4
    • /
    • pp.371-381
    • /
    • 1988
  • The purpose of this study was to investigate the physiological response to salt treatments in the leaves of several tree species. The results obtained were as follows : 1. The water potential of tree leaves damaged with various salt concentrations did not change nearly for 10 hours after treatment. As time elapsed after treatment, however, the higher salt concentration in soils, the higher leaf water potential was observed. 2. Leaf water potential of species intolerant to salt was higher than tolerant species due to the severe dehydration from cells. 3. According to the water relation parameters obtained from P-V curves, the values of ${\pi}_{\sigma}$ and ${\pi}_{\rho}$ in the damaged leaves were higher, but those of $V_{\rho}/V_{\sigma}$ and Emax were lower than those of the intact leaves. 4. The photosynthesis rate of tree leaves decreased remarkably with increasing the salt concentrations in soils, and it decreased faster for species intolerant cintolerant to salt.

  • PDF

A Study on the Safety Assessment and Damage Pattern of Water Purifier Compressors (정수기용 압축기의 안전성 평가 및 소손 패턴 분석에 관한 연구)

  • Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.2
    • /
    • pp.21-25
    • /
    • 2013
  • The purpose of this study is to provide basic data for the safety assessment of a water purifier when water leaks due to inappropriate maintenance and the examination of the cause of accidents related to the leak. Due to its inspection and management by non-specialists, if a leak occurs in a water purifier with the water level controller being inclined, it may result in the failure of the compressor, power supply line, PCB, etc. The analysis of the thermal diffusion pattern of water purifier compressors using a thermal image camera shows that its maximum temperature was approximately $80^{\circ}C$. In addition, its operating current was a maximum of 13 A and the system's operating current was approximately 1.7 A after the compressor was charged. It was found that the housing type power cable cover of the compressor had the effect of preventing electric shock but has poor flame resistance. Furthermore, the performance of the overload protector, PTC relays, etc., was excellent but they have potential for problems as metallic terminals were exposed, resulting in the potential of a safety related accident. The terminals and their surface damaged by the tracking showed a trace of carbonization and the resistance between terminals was measured to be approximately $8{\Omega}$. In addition, while the tracking was proceeding, the fuse and circuit breaker installed for system protection did not operate.

Internal Corrosion Control of Drinking Water Pipes by pH and Alkalinity Control and Corrosion Inhibitor (수질제어 및 부식억제제에 의한 상수도관의 내부부식 제어)

  • Kuh, Sungeun;Woo, Dalsik;Lee, Doojin;Kim, Juwhan;Ahn, Hyowon;Moon, Kwangsoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.2
    • /
    • pp.215-223
    • /
    • 2006
  • The internal corrosion of water distribution systems is the main cause for the problem of the public health threat as well as water leakage in the damaged pipeline, red water, and odor and taste of the tap water. This study was examined the effect of chemicals used for pH and alkalinity control and corrosion inhibitors for producing the optimal corrosion control method. Corrosion study at different pH and alkalinity indicated that these control using alkaline chemicals was effective in corrosion rate, Fe release reduction, but examined to be increased in turbidity and corrosion-by-products(TTHMs) problems. The turbidity was slightly increased, requiring caution in controlling corrosion with $Ca(OH)_2$. At pH 9.0, TTHMs concentration is increased two times corn pared with non-control of pH. Using the pipe which had experienced 28 years of exposure, iron release was decreased with the corrosion inhibitor. Consequently, pH, Alkalinity control method using alkaline chemicals must be complemented by corrosion inhibitor application for efficient corrosion control.

Responses of Quercus spp. to $SO_2$ ($SO_2$에 대한 참나무속 식물의 반응)

  • 이창석;배정오
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.7 no.3
    • /
    • pp.219-226
    • /
    • 1991
  • Results from study on physiological responses to $SO_2$ of Quercus spp. selected for restoration of vegetation damaged by air pollution in the field study were as follows. Tolerance of Quercus aliena, Q. acutissima and Q. mongolica used in this study to $SO_2$ was higher in that order and tolerance of these plants to $SO_2$ was high comparatively among trees composing of major forest vegetation of Korea including natural forests and plantations. Stomatal resistance of these plants was increased after exposure to $SO_2$ and range of increase was different among species. From discrepancy between order of tolerance to $SO_2$ and range of increase in stomatal resistance, we were estimated that resistance mechanisms of Quercus spp. were different among species as mechanism originated in avoidance and resistance, respectively. Water potential of plant leaves reduced after exposure to $SO_2$, degree of reduction accorded with order of tolerance to $SO_2$. Reduction of water potential of plants after exposure to $SO_2$ was initiated before appearance of visible damage in plant leaves and water potential of plants exposed to $SO_2$ of low concentration, in which plants were not showed viaible damage was also reduced.

  • PDF

Damage Cause Analysis for GCB of 154kv Power Plant (154kV 전력계통 가스차단기(GCB) 소손원인 조사분석)

  • Lee, Eun-Chun;Shin, Gang-Wook;Hong, Sung-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.425-427
    • /
    • 2000
  • The purpose of this study is to find the cause of the damage to the GCB(Gas Circuit Breaker), since the GCB of the 154kV power plant at the Hap-Cheon Dam has already been damaged twice. We researched the characteristics of this class of circuit breaker and the possible causes for this type of damage to the GCB using the FTA(Fault Tree Analysis) Method. We studied the optimal maintenance method of the GCB, the stability analysis and power serge protection of Hap-Cheon Dam, and the power serge and fault list of the power transmission line to help prevent a reoccurrence of the problem.

  • PDF

Property Analysis for On/off Surge of High-Voltage Motor (고압모터의 개폐써지 특성 분석)

  • Lee, Eun-Chun;Shin, Gang-Wook;Hong, Sung-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.422-424
    • /
    • 2000
  • Whenever the large-capacitor and high-voltage pump motor is opened and closed, the power factor improvement condenser and the low-voltage equipment are often damaged by the sparking and the on-off power serge. In order to find the reason and resolve the problem, we have installed a transition wave recorder for obtaining the transient on-off power serge wave and a power disturbance analyzer for long-time monitoring. In this way we measured and analysed the condition of the high-voltage pump motor whenever it is opened and closed.

  • PDF

Property Analysis for On/Off Surge of High-Voltage Condenser (고압콘덴서 개폐시 발생하는 써지의 특성 분석)

  • Hong, Sung-Taek;Lee, Eun-Chun;Shin, Gang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.235-237
    • /
    • 2002
  • Whenever the large-capacitor and high-voltage pump motor is opened and closed, the power factor improvement condenser and the low-voltage equipment are often damaged by the sparking and the on-off power serge. In order to find the reason and resolve the problem, we have installed a transition wave recorder for obtaining the transient on-off power serge wave and a power disturbance analyzer for long-time monitoring. In this way we measured and analysed the condition of the high-voltage pump motor whenever it is opened and closed.

  • PDF

Hydraulic Model Test and Numerical Analysis of Grass Concrete in River Environment (자연형 호안공법의 그라스콘의 수리모형실험 및 수치해석 연구)

  • Jang, Suk-Hwan;Park, Sung-Bum;Park, Sang-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1244-1248
    • /
    • 2007
  • This study aims at investigating the in situ applying grass concrete system in river environments which widely used nowadays and reviewing the effect and flow resistance for grass concrete structure through the physical experiments by hydraulic model test and developing application method in river bed which has rigid flood resistance. Grass concrete structure has been independently tested under high velocity flow under the super critical condition, as well as sud critical flow measuring velocity and water surface elevation along the cross section. This results shows grass concrete system is also suited to use in aggressive river environments such as repairing a flood damaged embankment that had placed at risk the adjacent drainage channel with vegetation.

  • PDF