• 제목/요약/키워드: water-cooling

검색결과 2,264건 처리시간 0.031초

EVALUATION OF AN ACCIDENT MANAGEMENT STRATEGY OF EMERGENCY WATER INJECTION USING FIRE ENGINES IN A TYPICAL PRESSURIZED WATER REACTOR

  • PARK, SOO-YONG;AHN, KWANG-IL
    • Nuclear Engineering and Technology
    • /
    • 제47권6호
    • /
    • pp.719-728
    • /
    • 2015
  • Following the Fukushima accident, a special safety inspection was conducted in Korea. The inspection results show that Korean nuclear power plants have no imminent risk for expected maximum potential earthquake or coastal flooding. However long- and short-term safety improvements do need to be implemented. One of the measures to increase the mitigation capability during a prolonged station blackout (SBO) accident is installing injection flow paths to provide emergency cooling water of external sources using fire engines to the steam generators or reactor cooling systems. This paper illustrates an evaluation of the effectiveness of external cooling water injection strategies using fire trucks during a potential extended SBO accident in a 1,000 MWe pressurized water reactor. With regard to the effectiveness of external cooling water injection strategies using fire engines, the strategies are judged to be very feasible for a long-term SBO, but are not likely to be effective for a short-term SBO.

수절환 및 냉매절환방식에 따른 지열히트펌프의 냉방특성에 관한 연구 (A Study on Cooling Characteristics of Ground Source Heat Pump with Variation of Water Switching and Refrigerant Switching Methods)

  • 차동안;권오경;박차식
    • 설비공학논문집
    • /
    • 제24권8호
    • /
    • pp.605-611
    • /
    • 2012
  • The objective of this study is to investigate the influence of the cooling performance for a water-to-water 10 RT ground source heat pump by using the water switching and refrigerant switching method. The test of water-to-water ground source heat pump was measured by varying the compressor speed, load side inlet temperature, and ground heat source side temperature. The cooling capacity and refrigerant mass flow rate of the heat pump increased with increasing ground heat source temperature. But COP of the heat pump decreased with increasing ground heat source temperature. As a result, the water switching method with counter flow, compared to a refrigerant switching method, improves the cooling capacity and COP by approximately 6~9% in average, respectively.

고온평판의 분무냉각특성에 관한 연구 (A Study on the Spray Cooling Characteristics of hot Flat Plates)

  • 윤석훈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권6호
    • /
    • pp.880-887
    • /
    • 1998
  • In order to study heat transfer characteristics of spray cooling for the purpose of uniform and soft cooling of high temperature surface a series of experiments for a hot horizontal copper flat plate was performed by downflow spray water using flat spray nozzle. Cooling curves were mea-sured under the various experimental conditions of flow rates and temperatures of cooling water Surface temperature surface heat fluxes and heat transfer coefficients of horizontal upward-facing flat surface were calculated with cooling curves measured at each radial positions near the cooling surface by TDMA method. Generally heat transfer characteristics for spray cooling is simi-lar to boiling phenomenon of pool boiling. The minimum heat flux(MHF) appear at the surface temperature of about ${\Delta}Tsat=250^{\circ}C$ and the critical heat flux(CHF) appear at about ${\Delta}Tsat=250^{\circ}C$.

  • PDF

SMART 원자로용 냉각재 순환펌프의 온도특성에 관한 연구 (A Study on the Temperature Characteristics of Main Coolant Pump for System-integrated Modular Advanced Reactor)

  • 구대현;방덕제;강도현;김종인;조윤현
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권5호
    • /
    • pp.320-326
    • /
    • 2000
  • The canned motor of 3-phase induction is used for main coolant pump(MCP). The type of motor is canned-motor that stator and rotor are welded by sealed can. So, cooling water flows in the air gap of the canned motor as an independent cycling cooling system from the air gap to yoke of the motor to prevent high temperature of stator can and to lubricate bearing. Heat exchange is occurred between cooling water in the air gap and cooling water from the exterior pump to prevent rising of temperature in the motor. I has to analyze the characteristics of can exactly because the loss and the heat in the can are very important to design MCP. Therefore, thermal analysis is studied considering the effect of eddy-current los induced in the can.

  • PDF

냉각계통의 구리 부식 생성물의 화학세정에 관한 연구 (A study on Chemical Cleaning of Copper Corrosion Product in cooling system)

  • 이한철;이창우;현성호
    • 상하수도학회지
    • /
    • 제13권1호
    • /
    • pp.140-145
    • /
    • 1999
  • This study was carried out a investigate the effect of chemical cleaning of corrosion product in cooling system made of copper and copper alloy as basic material and used cooling water as pure water. We studied chemical cleaning condition that minimizes the influence on basic material by means of EDTA solution so as to eliminate the slurry in cooling system. As a result, we found that the main components of sludge in cooling system produced by corrosion of copper were $Cu_2O$, CuO, Cu, and Fe. The optimum condition of chemical cleaning was 400 ppm EDTA solution at $60^{\circ}C$.

  • PDF

폐벤토나이트 분말의 소성 및 냉각조건에 따른 모르터의 압축강도 발현특성에 관한 연구 (The Study on the Compressive Strength Properties of Mortar using Discarded Bentonite Powder by the Cooling Method after Heat Treatment)

  • 김효열
    • 한국건축시공학회지
    • /
    • 제4권4호
    • /
    • pp.87-94
    • /
    • 2004
  • As the bentonite is main material to prevent from collapse of drilling hole at underground excavation works, it is increased using quantity on construction industry day by day. But, the discarded bentonite that is over using at underground excavation works is caused various enviromental trouble as soil and water pollution est. Therefore, this study aims to propose a foundamental report for pozzolan reaction of discarded Bentonite powder by heat-treatment and cooling as concrete mineral admixture. To find out pozzolan reaction ability of discarded Bentonite powder by indirect cooling & cooling using of water after heat-treatment, the experiments are excuted flow test & compressive strength on age of mortar using discarded Bentonite powder. As a result of this study, discarded Bentonite powder can be utilized as concrete mineral admixture by heat-treatment and especially, pozzolan reaction ability of discarded Bentonite powder is superior to the situation of 600℃. 60min & cooling using of water.

경제성 평가를 이용한 프리쿨링시스템의 국내 적용성 연구 (A Study on Application of the Free Cooling System with Dry Cooler Using Economic Evaluation)

  • 윤정인;손창효;김희민;김영민
    • 동력기계공학회지
    • /
    • 제19권4호
    • /
    • pp.50-55
    • /
    • 2015
  • Recently, because of the deterioration of the nuclear generating station and increase of the cooler and heater, energy problem is increasing. To save the energy, the free cooling system is developed. The free cooling system is that cool the water to use cooled air in winter and is used in industrial process or data center. Yoon check the energy of free cooling system with dry cooler in korea. In this study, the value of the free cooling system with dry cooler is confirmed through using the NPV that is economic evaluation. when temperature degree of the cooled water is 10, in Chuncheon and Seoul the value is the most high. When temperature degree of the cooled water is 20, in Ulsan the value is the most high. As the result, because the using the temperature degree of the cooled water is high in the industrial process, the free cooling system is advantageous in korea.

밀폐식 냉각탑용 열교환기의 성능에 관한 연구 (A Study on the Performance of Heat Exchanger for Closed Cooling Tower)

  • 이상식;유성연;김진혁;안영환;박형준;유해성
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.334-339
    • /
    • 2008
  • An closed cooling tower is a device similar to a general cooling tower, but with cooling tower replaced by a heat exchanger. The purpose of this study is to evaluate thermal performance of heat exchanger at various conditions and to provide design datebase. The experimental study regarding heat exchanger for closed cooling tower was conducted. Experimental apparatus consists of constant temperature bath, water pump, spray nozzle, heat exchanger, fan, and date acquisition system. Heat transfer rates at various air velocitys, water flow rates, two different spray modes were measured and heat transfer coefficient were calculated to compare the thermal performances. This study provides that the heat transfer coefficient increases with increasing spray water flow rate and with increasing air velocity. The wet mode was more effective than dry mode for closed cooling tower to this study.

  • PDF

선박용 흡수식 냉동기의 냉매적용 냉각 시스템 성능 분석 (Performance analysis of a cooling system with refrigerant in a marine absorption refrigerator)

  • 윤상국
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권4호
    • /
    • pp.282-287
    • /
    • 2016
  • 최근 조선사들은 선박이 운항되는 연안 환경의 개선과 보호를 위하여 $CO_2$를 절감할 수 있는 친환경 선박과 함께 선박 운항 중 소비하는 에너지의 절감을 위한 고효율화 선박 개발의 노력도 활발하게 수행하고 있다. 본 연구에서는 전기로 구동되는 선박의 증기압축식 냉동기 대신에 선박 엔진 자켓수의 폐열을 이용하여 냉방을 할 수 있는 흡수식 냉동기의 적용 가능성과 냉각시스템에 냉매를 적용하는 시스템의 성능을 분석하였다. 연구결과, 해수와 열교환하여 액화될 수 있는 냉매들 중 R236fa가 가장 적합한 냉매로 분석되었으며, 이를 적용한 흡수식 냉동기의 COP는 0.798로 육상의 냉각탑을 이용한 수랭식보다 15% 그리고 해수 열교환기식 수랭식보다 5% 향상되었다. 냉동능력 1RT를 얻기 위한 LiBr 흡수용액 순환량은 0.013 kg/s로 수랭식 보다 25% 이상 감소하며, 냉각 매체 순환량도 수랭식의 15.7%에 불과한 매우 효과적인 냉동기가 되었다. 해수온도가 $18^{\circ}C$ 이하로 낮으면 발생하게 되는 LiBr의 결정화는 재생기에서 배출되는 엔진 자켓수의 온도를 이용하여 해수 온도를 상승시킴으로써 방지할 수 있다.

물 직접접촉식 공기조화장치의 성능해석 (Performance Analysis of Water Direct Contact Air Conditioning System)

  • 유성연;권화길;송준;김광영;박준택
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.158-163
    • /
    • 2001
  • Performance of the water direct contact air conditioning system, in which heat and mass are transferred directly between air and water droplet, is simulated by semi-empirical method. This system improves transport efficiency compared to conventional indirect contact system and cooling, heating, dehumidification and humidification are attained with one unit. In this study, temperature and flowrate for air and water are measured in the various cooling and heating conditions, and correlations for $h_{c}A/c_{pm}$ are derived from these data. Cooling and heating characteristics of the water direct contact air conditioning system are investigated using correlations.

  • PDF