• Title/Summary/Keyword: water vapor absorption

Search Result 159, Processing Time 0.028 seconds

Carrier Gas Assisted Solvent Vapor Treatment for Surface Nanostructuring of Molecular Thin Films

  • Gong, Hye-Jin;Kim, Jin-Hyun;Yim, Sang-Gyu
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.3
    • /
    • pp.825-827
    • /
    • 2012
  • In this study, the variation in surface morphology of copper phthalocyanine (CuPc) thin films treated with a flow of acetone vapor assisted by nitrogen carrier gas was investigated. The CuPc nanorods with similar dimensions were well dispersed throughout the whole film surfaces after ~20 min. of treatment. However, the electronic absorption spectra only changed slightly, which indicates that molecular stacking was not altered during treatment. This treating method is simple and more advantageous compared to other solvent treating technologies such as mixed solvent spray treatment using organic solvents and water since it requires relatively mild treating conditions and does not need the presence of water.

Preparation of Honeycomb Carbon Dioxide Adsorbent Impregnated $K_2CO_3$ and Its Characterization ($K_2CO_3$를 담지시킨 고체 허니컴 이산화탄소 흡수제의 제조 및 이의 특성 평가)

  • Lee, Dong-Chul;Kim, Jin-Bae;You, Yoon-Jong
    • Applied Chemistry for Engineering
    • /
    • v.23 no.6
    • /
    • pp.624-629
    • /
    • 2012
  • To capture and recover carbon dioxide ($CO_2$), we impregnated honeycomb made of ceramic paper with $K_2CO_3$ and its absorption characteristics of $CO_2$ were investigated. The absorption amount of $CO_2$ on the honeycomb absorbent impregnated with $K_2CO_3$ was 13.8 wt% at a constant temperature ($70^{\circ}C$) and relative humidity (66%) condition. Because the absorption amount of $CO_2$ achieved almost the same loading ratio of $K_2CO_3$ (17.6 wt%), the absorption reaction of $CO_2$ by $K_2CO_3$ on the honeycomb absorbent seems to be going smoothly. In addition, $CO_2$ absorption breakthrough characteristics of the honeycomb absorbent were analyzed at the temperature range of $50{\sim}80^{\circ}C$, and the water vapor was fed to an absorption column before the feeding of $CO_2$ or simultaneously with $CO_2$. As a result, the absorption capacity of $CO_2$ was more enhanced using the water vapor supplying before $CO_2$ than that of simultaneous supplying. It was confirmed by temperature programmed desorption analysis that the $KHCO_3$ produced by the absorption reaction of $K_2CO_3$ and $CO_2$ is regenerated by the desorption of $CO_2$ at a temperature of about $128^{\circ}C$.

A Numerical Analysis of a Revised VX Absorption Cooling Cycle (Revised VX흡수식 냉동사이클의수치 해석)

  • 장원영;정은수;김병주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.505-513
    • /
    • 2001
  • A revised VX cycle using ammonia/water as the working fluid is a cycle which is suitable to produce cooling utilizing low temperature hat sources. The cycle was analyzed numerically to investigate the effects of the design and operating conditions on the performance. It was shown that both COP and cooling capacity were significantly influenced by the performance of he rectifier. Insufficient UA of the rectifier reduced both ammonia mass fraction and mass flow rate of the vapor entering the condenser, which produced cooling effect in the evaporator. As the temperature and the mass flow rate of the heat source increased, both COP and exergetic efficiency decreased due to the irreversibilities produced in heat exchangers, but cooling capacity did not vary much. Cooling capacity increased significantly as the coolant temperature decreased, although COP and exergetic efficiency remained nearly constant.

  • PDF

Separation Characteristics of Oxygen Isotopes with Hydrophobic PTFE Membranes (소수성 PTFE 막의 산소동위원소 분리특성)

  • 김재우;박상언;김택수;정도영;고광훈;박경배
    • Membrane Journal
    • /
    • v.13 no.3
    • /
    • pp.154-161
    • /
    • 2003
  • We measured the permeation characteristics of water with the hydrophobic PTFE membranes dependent on water temperature to confirm the separation of oxygen isotopes using Air Gap Membrane Distillation (AGMD) and Vacuum Enhanced Membrane Distillation (VEMD). Isotopic concentrations of $H_2^{16}O$ and $H_2^{18}O$ of the permeated water vapor were measured by Diode Laser Absorption Spectroscopy. Concentrations of the heavy oxygen isotopes in the permeated water vapor were decreased. Isotope separation coefficients for the hydrophobic PTFE membranes were 1.004∼1.01 depending on the experimental conditions. We observed the effects of air in membrane pores on the oxygen isotope separation. Isotope separation coefficients for the hydrophobic PTFE membranes without air in pores are higher than those for the membrane with air in pores.

Evaluation on solubility and vapor pressure of H2O/(LiBr+CaCl2) solution as a working fluid (H2O/(LiBr+CaCl2) 3성분계 흡수용액의 용해도 및 증기압 특성 평가)

  • No, S.Y.;Jang, Y.H.;Koo, K.K.;Jeong, S.;Kim, Y.W.;Kim, S.K.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.163-170
    • /
    • 1997
  • Solubility on $(LiBr+CaCl_2)$ in water has been measured systematically and compared with those of pure LiBr. It has been observed that there exists optimum value of $CaCl_2(LiBr+CaCl_2)$ in solubility when total$(LiBr+CaCl_2)$ concentration is higher than 57wt%. As total concentration increases up to 65wt%, it is found that the optimum value also increases monotonically. From the experimental results, a master plot has been constructed, with which optimum ratio of LiBr to $CaCl_2$ can be found in terms of total concentration. Vapor pressure of $H_2O/(LiBr+CaCl_2)$ solution with optimum contents of $CaCl_2$ has been observed to be changed negligibly at relatiely low temperature. However, as temperature increases, it is found that increasement in vapor pressure is significant.

  • PDF

Bondline Strength Evaluation of Honeycomb Sandwich Panel For Cure Process and Moisture Absorption (경화공정 및 수분흡수에 따른 복합재료 하니콤 샌드위치 판넬의 접합강도특성 연구)

  • Choe, Heung-Seop;Jeon, Heung-Jae;Nam, Jae-Do
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.1
    • /
    • pp.115-126
    • /
    • 2001
  • In this paper, through a series of comparative experiments, effects of two different cure processing methods, cocure and precure, on the mechanical properties of honeycomb core materials for aircraft applications are considered. Mass of moisture accumulated into the closed cells of the sandwich panel specimen from the measured mass of moisture diffused to the full saturation state into the elements(skin, adhesive layer, Nomex honeycomb), consisting the honeycomb sandwich specimen has been calculated. Water reservoir of 70$\^{C}$ was used to have specimens absorb moisture to see the influence of moisture absorbed into sandwich panel on its mechanical properties. For the repair condition holding for 2 hours at 177$\^{C}$(350℉) temperature, a pressure due to the vapor expansion in each cell of the sandwich panel, which may result in the local separation of the interface between laminated skin and the surface of the honeycomb, has been estimated by vapor pressure-temperature relation from the thermodynamic steam table and compared to the pressure from the ideal gas state equation. The bonding strengths of the laminated skins on the flat surface of the Nomex honeycomb have been compared by the flatwise tension test and climbing drum peel test performed at room temperature for dry, wet and wet-repair specimens, respectively.

A study on the wsggm-based spectral modeling of radiation properties of water vapor (회체가스중합법에 의한 수증기의 파장별 복사물성치 모델에 관한 연구)

  • Kim, Uk-Jung;Song, Tae-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.10
    • /
    • pp.3371-3380
    • /
    • 1996
  • Low resolution spectral modeling of water vapor is carried out by applying the weighted-sum-of-gray-gases model (WSGGM) to a narrow band. For a given narrow band, focus is placed on proper modeling of gray gas absorption coefficients vs. temeprature relation used for any solution methods for the Radiative Transfer Equation(RTE). Comparison between the modeled emissivity and the "true" emissivity obtained from a high temperatue statistical narrow band parameters is made ofr the total spectrum as well as for a few typical narrow bands. Application of the model to nonuniform gas layers is also made. Low resolution spectral intensities at the boundary are obtained for uniform, parabolic and boundary layer type temeprature profiles using the obtained for uniform, parabolic and boundary layer type temperature profiles using the obtained WSGGM's with 9 gray gases. The results are compared with the narrow band spectral intensities as obtained by a narrow band model-based code with the Curtis-Godson approximation. Good agreement is found between them. Local heat source strength and total wall heat flux are also compared for the cases of Kim et al, which again gives promising agreement.

An Experimental Study on Flow and Heat / Mass Transfer Characteristics of $LiBr-H_2O$ Solution Flowing over a Cooled Horizontal Tube (수평 냉각관 외부를 흘러내리는 $LiBr-H_2O$ 수용액의 유동 및 열/물질 전달 특성에 관한 실험적 연구)

  • Seal, Sin-Su;Lee, Sang-Yang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.8
    • /
    • pp.1085-1096
    • /
    • 2000
  • An experimental study was performed to examine the heat and mass transfer characteristics of $LiBr-H_2O$ solution flowing over a single horizontal tube with the water vapor absorption. Effects of the flow rate and the temperature of the solution at the top of the tube, the absorber pressure and the drainage pattern were considered. The absorption rate depends highly on the absorber pressure at the low flow rate condition while on the solution inlet temperature at the high flow rate condition. Also, when the flow rate is low, the absorption performance with the sheet flow drainage appeared to be higher than that with the dripping/jet drainage. However, at the high flow rate condition, the case became reversed. The liquid film became wavy with the higher absorption rate. The waves were more probable to form with the lower flow rate and temperature of the solution, and with the higher absorber pressure.

Stability of hydrophobic properties of plasma polymerized tetrakis(trimethylsilyloxy)silane film surface

  • Jang, Jinsub;Woo, Sungmin;Ban, Wonjin;Nam, Jaehyun;Lee, Yeji;Choi, Woo Seok;Jung, Donggeun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.147.1-147.1
    • /
    • 2016
  • Hydrophobic thin films are variously applicable for encapsulation of organic devices and water repulsive glass, etc. In this work, the stability of hydrophobic characteristics of plasma polymerized tetrakis (trimethylsilyloxy) silane (ppTTMSS) thin films were investigated. The films were deposited with plasma enhanced chemical vapor deposition (PECVD) on the glass. The deposition plasma power and deposition pressure was 70 W and 600 mTorr, respectively. Thereafter, deposited films were treated by 248nm KrF excimer laser. Stability of hydrophobic properties of plasma polymerized tetrakis(trimethylsilyloxy)silane film surface was tested by excimer laser irradiation, which is thought to simulate severe outdoor conditions. Excimer laser irradiation cycles changed from 10 to 200 cycles. The chemical structure and hydrophobicity of ppTTMSS films were analyzed by using Fourier transform infrared (FTIR) spectroscopy and water contact angle (WCA) measurement, respectively. Absorption spectra peaks and WCA of excimer laser treated ppTTMSS films did not change notably. These results show that our ppTTMSS films possess stable hydrophobic properties.

  • PDF

Trace Analysis of Water Vapor by Using Diode Laser Absorption Spectroscopy (다이오드레이저 흡수분광 방법을 이용한 수증기 미량 분석)

  • 김택수;김복실;박상언;정의창;정도영
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.176-177
    • /
    • 2003
  • 진공 환경 및 가스에 함유된 미량의 수증기를 정량적으로 분석할 수 있는 계측기는 각종 산업 분야에서 그 필요성이 절실하다. 몇 가지 예를 들면 다음과 같다. 전구 속에 함유된 수증기로 인해 야기되는 텅스텐 필라멘트의 산화현상은 전구의 수명을 현저히 감소시킨다. 밀봉된 금속 전기소자 표면에 흡착된 수증기를 통해 누전 현상이 발생함으로써 소자가 비정상적으로 동작될 우려가 있다. 반도체 산업분야에서는 1 ppb의 수증기가 64 Mb DRAM 제조에 영향을 줄 수 있다는 것이 보고된 바 있다. (중략)

  • PDF