• Title/Summary/Keyword: water transmission

Search Result 988, Processing Time 0.026 seconds

The Transmission Power Controllers for the VSAT Having the ALC Functions (ALC 기능을 갖는 VSAT용 송신전력 제어기)

  • Hong, Sung-Taek;Shin, Gang-Wook;Lee, Dong-Keun;Lee, Young-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2495-2497
    • /
    • 2005
  • The satellite communication equipment, which has been installed and operated for the flood forecast and warning system at KOWACO, needs the review of the transmission Power control for keeping the stable operation of the satellite communication equipments. In this study, made the sample hardware for the transmission power control at Mini-Hubs and remote sites, and developed the control algorithm for stable operation of the transmission power controller.

  • PDF

Optimal design and operation of water transmission system (상수도 송·배수시스템의 최적 설계 및 운영 모형 개발)

  • Choi, Jeongwook;Jeong, Gimoon;Kim, Kangmin;Kang, Doosun
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.12
    • /
    • pp.1171-1180
    • /
    • 2018
  • Korea's water transmission system is operated by the nonpressure flow method that flows from highlands to lowlands due to the nature of Korea with many mountainous areas. In order to store water in the highlands, the water pumps are installed and operated. However, In this process, a lot of electrical energy is consumed. therefore, it is necessary to minimize the energy consumption by optimizing the size and operation schedule of the water pumps. The optimal capacity and operation method of the water pump are affected by the size of the tank (distributing reservoir). Therefore, in order to economically design and operate the water transmission system, it is reasonable to consider both the construction cost of the water pump and the tank and the long-term operation cost of the water pump at the step of determining the scale of the initial facilities. In this study, the optimum design model was developed that can optimize both the optimal size of the water pump and the tank and the operation scheduling of the water pump by using the genetic algorithm (GA). The developed model was verified by applying it to the water transmission systems operated in Korea. It is expected that this study will help to estimate the optimal size of the water pump and the tank in the initial design of the water transmission system.

Feasibility Study of Multi-regional Transmission Main Stabilization for Sustainable Water Supply (수돗물 공급 안정화를 위한 광역상수도 관로 안정화 타당성 연구)

  • Lee, Jae Bum;Yi, Choong Sung;Jung, Kwan Sue
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.3
    • /
    • pp.395-404
    • /
    • 2013
  • The risk of pipe-bursting in multi-regional transmission mains consisting of 89 % of singled pipeline is so high that pipeline stabilization project is required such as renewal and replacement, pipe paralleling, emergency ties. Pipeline stabilization projects could be postponed at the step of initial decision-making because effect of this project is intangible benefit like activation of economic, improvement of welfare related to water. This study is to suggest quantified economical feasibility model for intangible benefit presumption to solve above problem. Cost reduction of emergency water supply, leakage, burst restore and energy efficiency improvement was altered and applied. As a result of economic analysis taking into account estimated benefit and cost under discount rate 5.5 %, service life 40 years, sufficient economic feasibility analyzed with B/C 2.45, NPV 317,700 million won, IRR 9.09 %.

Performance Comparison of Thermal Imagers with Uncooled and Cooled Detectors For Fire Fighting Application (비냉각형 적외선 센서를 이용한 열상시스템과 냉각형 적외선 센서를 이용한 열상시스템의 화재 진압 시 성능 비교)

  • Kim, Byung-Hyuk;Jung, Han;Kim, Young-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.2
    • /
    • pp.128-132
    • /
    • 2007
  • Thermal Imaging systems are reported to be crucial for fire fighting and beginning to be used by fire fighters. The performance of thermal imaging system is determined by both the radiation of infrared from the target and the attenuation of infrared signal in the optical path by the absorption, scattering, diffraction and reflection. In the scene of fire, water drops with various sizes such as vaporized water, wafer mist from sprinkler, and wafer to suppress the fire reside with various gas generated by burning. To measure the transmission of infrared radiation in the scene of fire, fire simulating system and thermal imagers with cooled detector which detects $3{\sim}5{\mu}m$ infrared and uncooled detector fabricated by the MEMS technology which detects $8{\sim}12{\mu}m$ infrared. are made. With thermal imagers and Ire simulating system, the change of thermal image with respect to the change of visibility controlled with the burned fas was measured. It was found that the transmission of infrared was not reduced by the burned gas, which could be explained by the long wavelength of infrared ray compared with visible ray. However, the transmission of infrared ray was largely reduced by the combination of burned gas and water mist supplied by sprinkler. This is contrary to the results of calculated transmission through the pure water mist and shows that the transmission of infrared ray is mostly affected by the compounds of water mist and burned gas. In this case, it was found that the uncooled detector which detects $8{\sim}12{\mu}m$ infrared ray is better than cooled detector which detects $3{\sim}5{\mu}m$ infrared ray for fire fighting.

Effects of UV Absorber and HALS(Hindered Amine Light Stabilizer) Addition in Water-soluble Acrylic Resin on Discoloration of Larix leptolepis (S. et Z.) Gordon (수용성(水溶性) 아크릴 수지(樹脂)의 자외선(紫外線) 흡수제(吸收劑)와 HALS 첨가(添加)가 일본잎갈나무의 변색(變色)에 미치는 영향(影響))

  • Kang, Kyoung-Taek;Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.47-55
    • /
    • 1996
  • UV transmission spectra of water-soluble acrylic resin films containing hydroxybenzophenolic, hydroxyphenylbenzotriazolic UV absorber and HALS(hindered amine light stabilizer) were investigated by exposure time(before exposure weathered for 160 and 320hours) in QUV Weather-Ometer. Also the YID(yellowness index difference), LID(lightness index difference) and CD(color difference) of dried water-soluble acrylic resin films and the coated woods of Larix leptolepis were analyzed by addition level of UV absorber(0, 1, 2 and 3%) and HALS(0, 0.5, 1 and 1.5%) and by exposure time in QUV Weather-Ometer. They showed no significant effects on UV transmission spectra of dried water-soluble acrylic resin films in the range of 300 to 400nm irrespective of exposure time. However, UV transmission decreased as increase of exposure time. UV transmission spectra were lower in dried water-soluble acrylic resin films containing hydroxybenzophenolic UV absorber and HALS than in these containing hydroxyphenylbenzotriazolic UV absorber and HALS in the range of 350 to 400nm. The least YID, LID and CD in the coated woods of Larix leptolepis appeared at the addition level of 3%, based on non-volatile content, in hydroxybenzophenolic and hydroxyphenylbenzotriazolic UV absorber, and of 1.5% in HALS to water-soluble acrylic resin.

  • PDF

The Wearing Sensation of Men and Women in Sports Wear with Waterproof and Water Vapor Permeable Fabrics (성인 남녀의 투습방수소재 스포츠 웨어의 소재별 착용감에 관한 연구)

  • Cho, Ji-Hyun;Ryu, Duck-Hwan
    • Korean Journal of Human Ecology
    • /
    • v.9 no.1
    • /
    • pp.47-61
    • /
    • 2000
  • The purpose of this study was to examine the performance and properties of sports wear that have the excellent wearing sensation and are in harmony with the functions of human bodies. With four kind(sample A, B, C, D) of materials which have different water vapor transmission, the physiological responses of human bodies and the changes of subjective sensations were studied through the actual aerobic sports program at $20^{\circ}C$, 60%R.H. The forehead temperature had the minimal variation among the local skin temperatures. The fabrics of low water vapor transmission demonstrated high breast temperature. There are significant differences among materials depending on the humidity in clothes(especially back and breast), which was about 6 % for breast and about 14 % for back. The order of loss in body weight was in the opposite direction to that of water vapor transmission for each material.

  • PDF

Layer-by-layer assembled graphene oxide films and barrier properties of thermally reduced graphene oxide membranes

  • Kim, Seon-Guk;Park, Ok-Kyung;Lee, Joong Hee;Ku, Bon-Cheol
    • Carbon letters
    • /
    • v.14 no.4
    • /
    • pp.247-250
    • /
    • 2013
  • In this study, we present a facile method of fabricating graphene oxide (GO) films on the surface of polyimide (PI) via layer-by-layer (LBL) assembly of charged GO. The positively charged amino-phenyl functionalized GO (APGO) is alternatively complexed with the negatively charged GO through an electrostatic LBL assembly process. Furthermore, we investigated the water vapor transmission rate and oxygen transmission rate of the prepared (reduced GO $[rGO]/rAPGO)_{10}$ deposited PI film (rGO/rAPGO/PI) and pure PI film. The water vapor transmission rate of the GO and APGO-coated PI composite film was increased due to the intrinsically hydrophilic property of the charged composite films. However, the oxygen transmission rate was decreased from 220 to 78 $cm^3/m^2{\cdot}day{\cdot}atm$, due to the barrier effect of the graphene films on the PI surface. Since the proposed method allows for large-scale production of graphene films, it is considered to have potential for utilization in various applications.

A research on the design parameters for a double-transmission main system for sustainable water supply (이중송수관로를 이용한 안정적인 송수를 위한 설계인자에 관한 연구)

  • Hyun, Inhwan;Hong, Juneui;Kim, Dooil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.129-138
    • /
    • 2013
  • Water interruption is often caused by a rupture in the branch-like singular pipeline. This will cause critical complaints from household and may decrease public service quality. As an alternative of singular pipeline, additional parallel pipeline could be installed for sustainable water supply. This system is called double pipeline system and able to be utilized for water transmission line between treatment plant and distribution reservoir. Construction of double pipeline was thought to increase capital cost, which can be an issue to waterworks authorities. Reducing capital cost was possible by means of installing connectors between two parallel pipelines because of reduced diameter of each pipe. To obtain optimal design condition for connectors, it was necessary to compare water pressure according to accident location, to investigate flow according to connection pipe spacing, connection pipe diameter, and aging of pipe. Reliable and economical connection layouts were determined based on these results. The cost estimation for each design condition was carried out. Cost was approximately reduced by 20 ~ 30 % compared to the double pipeline without connections. In addition to this, connection between double pipelines could expect extra benefits for maintenance since the pipe could be repaired and rehabilitated without interruption.

Water-Vapor Transfer Characteristics of Carrageenan-Based Edible Film (카라기난 필름의 투습 특성)

  • Rhim, Jong-Whan;Hwang, Keum-Taek;Park, Hyun-Jin;Jung, Soon-Teck
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.545-551
    • /
    • 1996
  • Water-vapor transmission rate and water-vapor permeability of carrageenan-based edible film with three different thicknesses of 0.05, 0.08 and 0.11 mm were measured to investigate the potential applicability of the films to powder foods at five different temperatures (20, 25, 30. 35 and $4^{\circ}C$) and three different relative humidities (50. 70 and 90% RH). Water-vapor transmission rate of the carrageenan-based film was gound to be 2.3 times higher than that of polyethylene (PE) film and water-vapor permeability of the film was 45-230 times higher than that of PE film. Water-ydpor permeability of the film seemed to increase linearly with the film thicknees like other hydrophilic edible films. Water-vapor transmission rate were found to be dependent on the temperature. Activation energies of the water-vapor transmission rate of the film were found to be between 7.898 and 12.8702 kj/mol depending on the film thickness. The water-vapor transmission rate of the film showed the typical kinetic compensation effect between activation energies and preexponential factors. which was proved by the linear increase in the value of logarithms of preecponential factor.

  • PDF

Environmentally Friendly Moisture-proof Paper with Superior Moisture Proof Property (I) -Properties of Moisture Proof Chemicals- (방습 효과가 우수한 환경친화적 방습지(제1보) -방습제의 특성-)

  • 유재국;조욱기;이명구
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.33 no.4
    • /
    • pp.15-20
    • /
    • 2001
  • The function of the moisture-proof paper is to prevent moisture from adsorbing into the packed goods. Water-vapor transmission rate of the moisture-proof paper should be less than 100g/$m^2$.24hr and the optimum rate would be less than 50g/$m^2$.24hr. In general the moisture-proof paper has been made by laminating polyethylene or polypropylene on top of the base paper. However this kind of moisture-proof paper has a problem in recycling so that it brings about environmental pollution. In general the moisture-proof paper has been made by laminating polyethylene or polypropylene on top of the base paper. However this kind of moisture-proof paper has a problem in recycling so that it brings about environmental pollution. The purpose of this paper was to make moisture-proof paper using the mixture of SB latex and wax emulsion which was recyclable and environmentally friendly. Water vapor transmission rate showed less than 50g/$m^2$.24hr in mixture ratio of 85:15, 87:13, 90:10. Especially the mixture ratio of 87:13 showed the most favorable water-vapor transmission rate. However, the moisture-proof layer was destroyed slightly by folding in packing. It has been observed that there was no close relationship between water-vapor transmission rate of the moisture-proof paper and grammage of the base paper, but the density of base paper had influenced on water vapor transmission rate. It was also observed that the moisture-proof paper could be recycled. The moisture-proof paper was similar to base paper in degree of the pulping, and there was no significant difference in dispersion between moisture-proof paper and base paper. Most of wax particles which caused the spots during drying process could be removed by flotation process. Tensile strength and tear strength of both moisture-proof paper and base paper after pulping were measured to examine the fiber bonding, and no significant difference in physical properties was observed.

  • PDF